COMBUSTION AIR SYSTEM

Model: CAS-2WM WEIL-MCLAIN OUTSIDE AIR KIT FOR USE WITH OIL BURNER MODELS QB-180 & QB-300 The Air Boot™ model CAS-2WM is for use only on the designated burner(s) as described in these instructions only when the specific burner includes this Air Boot™ when shipped from the burner manufacturer or where the burner instructions specifi

THE PURPOSE OF THE VACUUM RELIEF VALVE (VRV)

The vacuum relief valve provides combustion air to the burner if the outside air supply is interrupted for any reason. Typical situations would be blockage of the air intake or duct, or wind effect which cause a negative pressure at the air intake hood. VRV OPERATION With normal air flow through the air in

9. Mount the VRV tee assembly or 90° elbow onto the Air Boot™ intake.

Fasten using three (3) sheet metal screws on all joints (See Figure 5). 10. Assemble the VRV balance weight onto the gate. Screw the weight all the way in. Then attach lock nut and knurl nut (See Figure 6). 11. Mount the VRV assembly onto the tee and fasten with the supplied scr

AIR INTAKE BOOT AIR SETTING

1. Follow the instructions in the Boiler and Burner Installation Manuals for adjusting and setting the burner. WARNING: Failure to properly adjust the burner after installing this kit can result in severe personal injury, death or substantial property damage. 2. Loosen the air band screw on the Air Boot™. Po