Field Controls 46385600 Manual
Text of Field Controls 46385600 Manual
COMBUSTION AIR SYSTEM
Model: CAS-2A
This product is designed for use on the following burners, for the purpose of routing
combustion air directly to the burner, with the added safety feature of the vacuum relief valve.
NOTE: For burner inputs up to 2.0 GPH at 100 PSI input pressure or equivalent.
“The Air Boot™ model CAS-2A is for use only on the designa
THE PURPOSE OF THE VRV
The Vacuum Relief Valve is a safety device to guard against combustion problems associated with directly
connecting oil burners to the outside. Typical problems can be caused by blockage of the intake termination,
icing up of the duct work and effects of leeward side wind effects on a building.
VRV OPERATION
The VRV gate operate
2. Assemble VRV balance weight onto the gate. Screw the
weight all the way in. Then attach lock nut and knurl
nut. (See Figure 3)
3. Mount the VRV assembly onto the tee and fasten with a
screw and nut in collar tabs. To ensure proper
operation, check the gate for being level across the
pivot points and plumb. (See Figure 4)
4. Refer to Figure 5 for ge
Longer pipe lengths require the use of a larger pipe between the VRV and the intake hood. It also requires the
use of a vent pipe increaser at the VRV and a reducer at the intake hood. (See Table 1)
Table 1
Pipe
Diameter
Maximum Equivalent
Pipe Feet (between Air boot™
and duct termination)
Elbow*
Equivalent
Feet
Reducer or
Increaser
Equivalent Feet