TOTALINE Easy Stat Owner's Manual
Read Online
Read the TOTALINE Easy Stat Owner's Manual online using the built-in PDF viewer.
Easy Stat Owner's Manual: Key Pages of Document
Easy To Read Display Thermoglow Backlight Remote Sensor Ready Multi-Stage, One for All Use with most Air Conditioning & Heating Systems including: 1 or 2 Stage Electric Cooling & Gas Heating, Heat Pump, Electric or Hydronic Heat. * TOTALINE TOTALINE 7:00 68 72 Am WAKE HEAT Easy STAT OWNER'S MANUAL P374-1100EZ ...
Page 1 CAUTION Follow Installation Instructions before proceeding. SET THERMOSTAT TO MODE “OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS. Carrier Corporation 10/01 FRONT PANEL DISPLAY QUICK START Set the clock and go BASIC OPERATION PROGRAMMING 2 Time Periods ADVANCED SETUP ABOUT ADVANCED OPERATION WARRANTY 2 3 4 5 7 9 12 16 P374-1100EZ ...
Warmer or + Button Cooler or - Button Mode/ Next Button Heat or Cool Indicator Red = Heat, Green = Cool TOTALINE 12:00 74 72 Pm : WAKE HEAT PROGRAM ON/OFF SET PROGRAM FAN PROGRAM ON/OFF SET CLOCK SET PROGRAM FAN SET CLOCK MODE/NEXT OUTSIDE o OUTSIDE 12:00 74 Pm : WAKE HEAT 72 Easy STAT RESIDENTIAL Page 2 This Big Letter label is also available for easy identification of the thermostat buttons. OUTSIDE FAN SET PROGRAM PROGRAM ON/OFF SET CLOCK MODE/ NEXT o MODE/ NEXT ...
WAKE/SLEEP - indicates the stored program is running. HEAT - indicates the heat mode. COOL - indicates the air conditioning mode. OFF - indicates the entire system is turned off. Clock Display Indicates the current time of day. Page 4. Room Temperature Display Indicates the current room temperature. Desired Set Temperature Indicates desired room temperature. Page 7. Outside Indication Indicates the temperature displayed is from the optional outside sensor. Fan Operation Indication Fan On - indic ...
. (Represented in dark black) Pressing the Up and Down buttons will modify the flashing selection. Press the SET CLOCK button. Press the SET CLOCK button as above to return to normal operation, after setting the clock. Quick Start Set the Clock and Go Page 4 This thermostat is preprogrammed from the factory to operate 1 or 2 Stage equipment without the need for further programming. To optimize the installation of this thermostat follow the instructions in the Advanced Setup section. buttons. To adjust the clock use Am 12:00 : SET CLOCK SET CLOCK To adjust just the Hours; hold the Fan button in pres ...
desired Set Temperature with Pressing the up/down buttons in Heat or Cool modes will adjust only the heat or cool set temperature. Select Desired Temperature Page 5 Basic Operation Press FAN Fan Operation Fan On indicates constant fan operation. This feature is active even if the thermostat is set to Off. 12:00 70 69 Am : HEAT 12:00 65 OFF Am : ON FAN ...
temperature the room has to reach before the furnace will turn on to heat the room. The COOL setting indicates the temperature the room has to reach before the air conditioner will turn on to cool the room. Select Mode OFF indicates both heating and air conditioning systems are turned off. Press Press MODE/NEXT 12:00 72 74 Am : COOL 12:00 72 72 Am : HEAT 12:00 72 OFF Am : MODE/NEXT NOTE: WHEN THE THERMOSTAT IS IN THE OFF MODE, YOU MAY TURN THE THERMOSTAT BACK ON BY PRESSING THE MODE/NEXT, UP, OR DOWN BUTTONS. ...
setup and return to normal operation after 60 seconds. Programming Heat Schedule Adjust the heating setpoint for Wake. Select the start time for Wake. Select the start time for Sleep. (35 - 99 ) Adjust the heating setpoint for Sleep. (35 - 99 ) Press the Set Program button. SET PROGRAM 72 74 HEAT COOL OCCUPIED 1 AUTO o o Am 6:03 68 TOTALINE The thermostat must be in the Heat mode to access these setup steps. 7:00 Am WAKE 7:00 68 Am WAKE HEAT I0:00 Pm : SLEEP I0:00 65 Pm : SLEEP HEAT Press Press Press Press MODE/NEXT MODE/NEXT MODE/NEXT Press th ...
setpoint for Wake. Select the start time for Wake. Select the start time for Sleep. (35 - 99 ) Adjust the cooling setpoint for Sleep. (35 - 99 ) 72 74 HEAT COOL OCCUPIED 1 AUTO o o Am 6:03 68 TOTALINE The thermostat must be in the Cool mode to access these setup steps. 7:00 Am WAKE 7:00 74 Am WAKE COOL I0:00 Pm : SLEEP I0:00 78 Pm : SLEEP COOL MODE/NEXT MODE/NEXT MODE/NEXT NOTE: If no buttons are pressed the thermostat will leave setup and return to normal operation after 60 seconds. Press the Program Set or Mode/Next ...
the bottom right corner of the display for easy reference. Select whether the thermostat will be straight heat, or straight cool, or both heat and cool. Press the Mode/Next button. While holding the Mode/Next, press the Program On / Off button to enter Setup screens. PROGRAM ON / OFF MODE/NEXT Yes 2 L I 3 COOL No 4 HP Select Yes to have the backlight always on, No to have the backlight turn off after 8 seconds after a key press. Yes No Select Yes if the thermostat is controlling a heatpump, No for all other types of equipment. Yes No O 5 Select the r ...
hour limit. d=cycles per hour limit defeated. d1=d + defeat 5 min. Compressor lockout. (d, d1, 2 - 6) NO 6 EH 2 7 6 8Cy Select thermostat operation in degrees Fahrenheit or Centigrade. F C F 9 Select Electric Heat Yes if the strip heater is your First Stage of heat. (Step 6 only appears if step 4 is Yes for heat pump). Yes No 88 Adjust the deadband from 1 - 6 degrees. To Exit Press PROGRAM ON / OFF MODE/NEXT MODE/NEXT MODE/NEXT ...
1 Time of day clock set 24 hour 12:00 Am 2 3 Heat Cool Heat/Cool Heat/Cool 4 5 6 7 Thermoglow backlight Yes/No Yes Configure for Heat Pump Yes/No No Reversing Valve polarity O / B O Electric Heat Yes/No ...
Page 12 MEMORY BACKUP - In the event of a power loss, the thermostat will retain the stored program settings without external power or batteries. EMERGENCY HEAT - Is a feature available to Heat Pump installations. To turn on Emergency Heat press in the Fan button. While holding the Fan button press Up button. You must be in HEAT mode to activate emergency heat. During Emergency Heat the thermostat will not attempt to energize the 1st stage compressor. When there is a heat demand, the thermostat engages the 2nd stage of heat along with the fan. ...
Page 13 ELECTRIC HEAT - Selecting Electric Heat on, page 9, step 6, will cause the thermostat to turn on the fan any time there is a heat demand. Since all control the fan, this feature should be off is only electric. immediately gas furnaces unless the heater FACTORY DEFAULTS - If, for any reason it is desirable to return all stored settings back to the factory default settings, press the Mode/Next button. While holding the Mode/Next button in, press the Fan button for 5 sec. All icons will appear. Press and hold in the Fan button until Fd appears. This resets all facto ...
Page 14 Page 14 The most common way to program the EasyStat thermostat is to program it just as you would an alarm clock. You program the stat in the HEATING MODE, normal winter operation, and you can also program it in the COOLING MODE, normal summer operation. It will keep these set points stored and use them any time that the program is on, (WAKE/SLEEP -shown on display). It will only use the COOLING set points when the mode is in cooling and only use the HEATING set points when the mode is heating. To program the thermostat, just put it in the HEATING or COOLING MODE, press the SET PROGRAM button, and then the ...
and then you wake up to a comfortable temperature. Turn the thermostat down when you leave for work and you will return to a comfortable temperature when you get home, at the same time receive the large energy savings, up to 30%, of not having your house heated or cooled when you are not there. On Saturdays and Sundays, since you are there all day long, you do not set the temperature back so the house is maintained at a comfortable temperature all day. This thermostat is so easy to set, you can easily change the SLEEP/RETURN temperature. Let’s say you were going to the mall for two ro thre ...
workmanship. If it appears within one year from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactured part, at the manufacturer’s sole option, to replace any defective part will be provided without charge for the part itself; PROVIDED the defective part is returned to the distributor through a qualified servicing dealer. THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS incurred for diagnosing, repairing, removing, installing, shipping, servicing or ...
Thermostat PDF Instructions
Operation guide for the Bryant TSTATBBP250-LA Thermostat. The manual includes instructions for service contacts, maintenance guidelines, system parameters, testing procedures.
cadetheat.com 855.CADET.US Vancouver, Washington tested to UL standards MORE COMFORT, LESS ENERGY OWNER’S GUIDE COM-PAK http://cadetheat.com/install/energyplus For how-to videos or more information, please visit: ESPAÑOL ver la guía del propietario en cade Technical setup manual for the Cadet Energy Plus CEC163TW Thermostat. It offers guidance on firmware updates, maintenance procedures, installation support, device safety checks.
Download the Smart Life app from the IOS or Android Store. And create a unique account and password. In the home screen of smart life. Press on the area highlighted to add a thermostat to the App. On the next screen please select small home appliances and th Practical user guide for the Living Heat SmartLife CT1000 Thermostat. This documentation highlights features and regulatory notices, product safety, safety information.
Operating Manual Totaline ® Easy 1H/1C and 2H/1C Programmable P320 Series Thermostat 570-210 69-2261EFS-01 ® Product instruction handbook for the TOTALINE Basic 2H/1C Thermostat. The document explains device features, operational safety, performance guidelines.