Trane 4YCY4060A Product Data
File Specifications
| Brand: | Trane |
| Category: | Air Conditioner |
| Model: | 4YCY4060A (Product Data), prtSAyiHFF.N2 |
| File Type: | |
| File Size: | 3.08 Mb |
| Pages: | 29 pages |
Download PDF
Download Trane 4YCY4060A Manual (29 pages)Read Online:
Read the Trane 4YCY4060A Product Data online using the built-in PDF viewer.
Key Pages of Document
Pub. No. 22-1797-03 Product Data 4YCY4024A through 4YCY4060A Single Packaged Convertible Gas/Electric 14 SEER 2 - 5 Ton, 40 - 120 KBTU R-410A 22-1797-03 ...
Single Packaged Convertible Gas/Electric System Trane offers a complete family of packaged gas/electric heating and cooling sys- tems, designed to give you the unbeatable combination of energy efficiency and lower operating costs. In warm weather, the packaged gas/electric system functions as an all-electric, high efficiency air ...
4 General Data 5 Performance Data Cooling 9 Indoor Fan 11 Typical Wiring 15 Optional Equipment 18 Dimensional Data 23 Mechanical Specifications 29 ...
OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [✓✓✓✓✓] indicates accessories included) Hinged Filter Access Door (4YCY4024-036) 8 ................................................................ BAYACCDOR1A[ ] Hinged Filter Access Door (4YCY4042-060) 8 .............................................................. ...
Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr.)n Sound Power Rating [dB(A)]8 Performance Heatingk Input BTUH - 1st Stage (Natural Gas)p Input BTUH - 2nd Stage (Natural Gas)p AFUE Temp. Rise — Min/Max (°F) Orifice Qty / Drill Size (Natural Gas)l POWER CONN.—V/PH/HZ Min. Brch. Cir. Ampacitym ...
Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr.)n Sound Power Rating [dB(A)]8 Performance Heatingk Input BTUH - 1st Stage (Natural Gas)p Input BTUH - 2nd Stage (Natural Gas)p AFUE Temp. Rise — Min/Max (°F) Orifice Qty / Drill Size (Natural Gas)l POWER CONN.—V/PH/HZ Min. Brch. C ...
Standard 270. 2 2 2 2 2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ...
Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr.)n Sound Power Rating [dB(A)]8 Performance Heatingk Input BTUH - 1st Stage (Natural Gas)p Input BTUH - 2nd Stage (Natural Gas)p AFUE Temp. Rise — Min/Max (°F) Orifice Qty / Drill Size (Natural Gas)l POWER CONN.—V/PH/HZ Min. Brch. C ...
4YCY4036A1/3 AT 1200 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL AMB WB CAP 72 75 78 80 KW 85 59 34.5 28.8 32.4 34.5 34.5 2.7 63 36.0 23.4 27.0 30.5 32.9 2.7 67 38.8 18.5 22.0 25.6 27.9 2.8 71 41.9 13.5 17.1 20.6 23.0 2.8 95 59 32.0 27.6 31.2 32.0 32.0 3.0 63 33.4 22.3 ...
4YCY4048A1/3 AT 1600 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL AMB WB CAP 72 75 78 80 KW 85 59 45.3 38.2 42.9 45.3 45.3 3.6 63 47.2 31.0 35.7 40.5 43.7 3.6 67 50.9 24.4 29.1 33.9 37.1 3.7 71 55.0 17.7 22.5 27.3 30.4 3.7 95 59 42.7 37.0 41.7 42.7 42.7 3.9 63 44.5 29.8 ...
⚠️ Download Safety
The Air Conditioner Product data (29 pages) is completely safe to download (last scan date: 11/04/2026).
Related PDF Instructions for Trane 4YCY4060A:
-
Trane BAYEVAC05LG1A Electric Heater Installer's manual, 16 pages
-
Trane CGAD020C Chiller Manual , 33 pages
-
Trane TR-SCS Series Cooling boxes Installation, operation and maintenance manual, 32 pages
-
Trane Precedent TSC060 Chiller Installation operation & maintenance, 44 pages
-
Trane 4TTM3018 Industrial Equipment Installer's manual, 28 pages
-
Trane 4YCA4024A1060A Chiller Installer's manual, 28 pages