Frigidaire FEQBB30DS0 Installation Instructions Manual
Text of Frigidaire FEQBB30DS0 Installation Instructions Manual
P/N 134306200A (0312)
Save These Instructions
Before beginning installation, carefully read these instructions. This will simplify the installation and ensure
the dryer is installed correctly and safely. Leave these instructions near the Dryer after installation for future
reference.
NOTE: The electrical service to the Dryer must conform with local codes and ordinances and the latest edition of the
National Electrical Code, ANSI/NFPA 70.
NOTE: The ga
Tools and Materials Required for Installation:
1. Phillips head screwdriver.
2. Channel-lock adjustable pliers.
3. Carpenter's level.
4. Flat or straight blade screwdriver.
5. Duct tape.
6. Rigid or flexible metal 4 inch (10.2 cm) duct.
7. Vent hood.
8. Pipe thread sealer (Gas).
9. Plastic knife.
ELECTRICAL REQUIREMENTS
ELECTRIC Dryer
CIRCUIT - Individual 30 amp. branch circuit fused
VENTILATION SYSTEM REQUIREMENTS
Air flow (ventilation) through the dryer is critical in the ability of
the dryer to function properly. Heat and air are required to dry
clothes. Heat provides energy to evaporate the moisture in the
clothes. Air is used to carry the heat to the clothes load and
exhaust the evaporated moisture outside. Without adequate air
flow, the heated air can not get to the clothes and they won’t
dry. There are two major components i
Although vertical orientation of the exhaust system is accept-
able, certain extenuating circumstances could affect the perfor-
mance of the dryer:
•
Only the rigid metal duct work should be used.
•
Venting vertical through a roof may expose the exhaust
system to down drafts causing an increase in vent
restriction.
•
Running the exhaust system through an uninsulated
area may cause condensation and faster accumulation
of lint.
•
Compression or cri
60 sq. inches
(387.1 sq. cm)
15" (38.1 cm)
0" (0 cm)
60 sq. inches
(387.1 sq. cm)
1" (2.54 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
0" (0 cm)
1" (2.54 cm)
LOCATION OF YOUR DRYER
DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside weather
conditions.
2. In an area where it will come in contact with curtains, drapes,
or anything that will obstruct the flow of combustion and
ventilation air.
3. On carpet. Floor MUST be solid
UNDER COUNTER & STACK MODELS
(2.54 cm)
REAR VIEW
36"
(89.5 cm)
(6.5 cm)
(9.5 cm)
ELECTRIC CONNECTION
13 1/2"
(34.4 cm)
(68.3 cm)
3/8" (0.96 cm) Dia. GAS
PIPE
(68.6 cm)
3/4"
(1.9 cm)
SIDE VIEW
4 3/8"
(11.1 cm)
47 1/2"
(120.7 cm)
OPTIONAL
VENT KNOCKOUT
3 3/4"
(9.5 cm)
UNDER
COUNTER
34 5/8"
(87.9 cm)
MOBILE HOME INSTALLATION
1. Dryer MUST be exhausted outside (outdoors, not beneath
the mobile home) using metal ducting that will not suppo
TOP CONSOLE MODELS
(68.6 cm)
SIDE VIEW
OPTIONAL
VENT KNOCKOUT
4 3/8"
(11.1 cm)
47 1/2"
(120.7 cm)
REAR VIEW
(68.3 cm)
(2.54 cm)
(110.7 cm)
(6.5 cm)
(9.5 cm)
3/8" (0.96 cm) Dia.
GAS PIPE
ELECTRIC CONNECTION
13 1/2"
(34.4 cm)
3 3/4"
(9.5 cm)
36"
(91.5 cm)
REVERSING DOOR SWING
Your dryer is designed so the door swing may be reversed at
any time without additional parts. Conversion is accomplished
by transferring hinges to the opposite si
This dryer is equipped with a three-prong (grounding) plug
for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong
receptacle. Do not cut or remove the grounding prong from
this plug.
ELECTRICAL INSTALLATION
ELECTRIC Dryer
The following are specific requirements
for proper and safe electrical installation of your dryer.
Failure to follow these instructions can create electrical
shock and/or
FOR 4-WIRE SYSTEM
ELECTRIC Dryer
1. Remove the screws securing the terminal block access
cover and the strain relief mounting bracket located on
the back of the dryer upper corner.
2. Install a U.L. approved strain relief in the entry hole of
the mounting bracket. Finger tighten the nut only at this
time.
3. Remove the green neutral ground wire from the green
ground screw located above the terminal block.
4. Thread a U.L. approved