UNI-T UT39A Operating Manual
Text of UNI-T UT39A Operating Manual
TABLE OF CONTENTS
TITLE
PAGE
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Functional Buttons
Display Symbols
Measurement Operation
A. DC Voltage Measurement
B. AC Voltage Measurement
C. DC Current Measurement
D. AC Current Measurement
E. Measuring Resistance
F. Frequency Measurement (The Model UT39C only)
G. Temperature Measu
UNI-T UT39A I. Diodes and Continuity Test
J. Transistor Test
Maintenance
A. General Service
B. Replacing the Battery
C. Replacing the Fuses
Model UT39A/B/C: OPERATING MANUAL
2
To avoid electric shock or personal injury, read the
“Safety Information” and “Rules for Safety Operation”
carefully before using the Meter.
Digital Multimeters Model UT39A, UT39B and UT39C
(hereafter referred to as “the Meter”) are 3 1/2 digits with
steady operations, fashionable structure and highly
reliable hand-held measuring instrument. The Meter uses
large scale of integrated circuit with double integrated
A/D co
This Meter complies with the standards IEC61010: in
pollution degree 2, overvoltage category (CAT. I 1000V,
CAT. II 600V) and double insulation.
CAT. I: Signal level, special equipment or parts of
equipment, telecommunication, electronic, etc., with
smaller transient overvoltages than overvoltages CAT. II.
CAT. II: Local level, appliance, PORTABLE EQUIPMENT
etc., with smaller transient voltage overvoltages than
CAT. III
Use the Meter onl
Rules For Safe Operation
Warning
To avoid possible electric shock or personal injury,
and to avoid possible damage to the Meter or to the
equipment under test, adhere to the following rules:
l
l
l
l
l
l
l
l
l
Before using the Meter inspect the case. Do not
use the Meter if it is damaged or the case (or part
of the case) is removed. Look for cracks or missing
plastic. Pay attention to the insulation around the
connectors.
Inspect the test leads fo
continuity, diodes, capacitance or current.
Before measuring current, check the Meter’s fuses
and turn off power to the circuit before connecting
the Meter to the circuit.
Replace the battery as soon as the battery indicator
appears. With a low battery, the Meter might
produce false readings that can lead to electric
shock and personal injury.
Remove test leads and temperature probe from
the Meter and turn the Meter power off befo
Deficiency of Built-In Battery
AC (Alternating Current)
AC or DC
Double Insulated
Warning. Refer to the Operating Manual
Conforms to Standards of European Union
Grounding
DC (Direct Current)
Diode
Continuity Test
Fuse
International Electrical Symbols
The Meter Structure (see figure 1)
1. LCD Display
2. Data Hold Button
3. Transistor Jack
4. COM Input Terminal
5. Other Input Terminals
6. mA Input Terminal
7. 20A/10A Input Terminal
8. Capacit
Turn the Meter on and off.
Press down the POWER to turn on the Meter.
Press up the POWER to turn off the Meter.
Press HOLD once to enter hold mode.
Press HOLD again to exit hold mode.
In Hold mode, is displayed and the
present value is shown.
Functional Buttons
Below table indicated for information about the functional
button operations
l
l
l
l
l
Display Symbols
UNI-T UT39A Make sure the Sleep Mode is not on if you found there
is no display on the LCD after turning on the Meter.
Make sure the Low Battery Display is not on,
otherwise false readings may be provided.
Pay extra attention to the symbol which is located
besides the input terminals of the Meter before carrying
out measeurement.
l
l
l
A. DC Voltage Measurement (see figure 3)
Warning
To avoid harms to you or damages to the Meter from
electric shock, pleas
If the value of voltage to be measured is unknown,
use the maximum measurement position (1000V) and
reduce the range step by step until a satisfactory
reading is obtained.
The LCD displays “1” indicating the existing selected
range is overloaded, it is required to select a higher
range in order to obtain a correct reading.
In each range, the Meter has an input impedance of
approx. 10MΩ.This loading effect can
If the value of voltage to be measured is unknown, use the maximum measurement position (750V) and
reduce the range step by step until a satisfactory
reading is obtained.
The LCD displays “1” indicating the existing selected
range is overloaded, it is required to select a higher
range in order to obtain a correct reading.
In each range, the Meter has an input impedance of
approx. 10MΩ. This loading effect can cause
measurement errors
4. Break the current path to be tested. Connect the red
test lead to the more positive side of the break and
the black test lead to the more negative side of the
break.
5. Turn on power to the circuit.
The measured value shows on the display.
To measure current, do the following:
1. Turn off power to the circuit. Discharge all high-voltage
capacitors.
2. Insert the red test lead into the mA or 20A or 10A
terminal and the black tes
UNI-T Multimeter Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | For Device |
|---|---|---|---|---|---|---|---|
UT81B |
#RTZ4AI: UT81B Multimeter Operating manual |
55 | 0.93 Mb | 333 | 77 | 31-07-2026 | view all |
UT51-55 |
#64R55V: UT51-55 Multimeter Operating manual |
20 | 1.46 Mb | 1135 | 239 | 13-04-2026 | view all |
UT151D |
Guide: UNI-T UT151D (HOQRO4, Upd.18-07-2026) |
2 | 1128 | 271 | 18-07-2026 | view all | |
UT531 |
#Q47P95: UT531 Multimeter Manual |
32 | 190 | 35 | 26-09-2026 | view all | |
UT801 |
UT801 Operating manual - I534NV |
2 | 0.53 Mb | 1108 | 266 | 24-08-2026 | view all |
UT58D |
#XL3I42: UT58D Multimeter Operating manual |
2 | 371 | 90 | 03-05-2026 | view all |