UNI-T UT39A Operating Manual

Text of UNI-T UT39A Operating Manual

TABLE OF CONTENTS

TITLE PAGE Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Display Symbols Measurement Operation A. DC Voltage Measurement B. AC Voltage Measurement C. DC Current Measurement D. AC Current Measurement E. Measuring Resistance F. Frequency Measurement (The Model UT39C only) G. Temperature Measu

UNI-T UT39A I. Diodes and Continuity Test

J. Transistor Test Maintenance A. General Service B. Replacing the Battery C. Replacing the Fuses Model UT39A/B/C: OPERATING MANUAL 2

To avoid electric shock or personal injury, read the

“Safety Information” and “Rules for Safety Operation” carefully before using the Meter. Digital Multimeters Model UT39A, UT39B and UT39C (hereafter referred to as “the Meter”) are 3 1/2 digits with steady operations, fashionable structure and highly reliable hand-held measuring instrument. The Meter uses large scale of integrated circuit with double integrated A/D co

This Meter complies with the standards IEC61010: in

pollution degree 2, overvoltage category (CAT. I 1000V, CAT. II 600V) and double insulation. CAT. I: Signal level, special equipment or parts of equipment, telecommunication, electronic, etc., with smaller transient overvoltages than overvoltages CAT. II. CAT. II: Local level, appliance, PORTABLE EQUIPMENT etc., with smaller transient voltage overvoltages than CAT. III Use the Meter onl

Rules For Safe Operation

Warning To avoid possible electric shock or personal injury, and to avoid possible damage to the Meter or to the equipment under test, adhere to the following rules: l l l l l l l l l Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. Pay attention to the insulation around the connectors. Inspect the test leads fo

continuity, diodes, capacitance or current.

Before measuring current, check the Meter’s fuses and turn off power to the circuit before connecting the Meter to the circuit. Replace the battery as soon as the battery indicator appears. With a low battery, the Meter might produce false readings that can lead to electric shock and personal injury. Remove test leads and temperature probe from the Meter and turn the Meter power off befo

Deficiency of Built-In Battery

AC (Alternating Current) AC or DC Double Insulated Warning. Refer to the Operating Manual Conforms to Standards of European Union Grounding DC (Direct Current) Diode Continuity Test Fuse International Electrical Symbols The Meter Structure (see figure 1) 1. LCD Display 2. Data Hold Button 3. Transistor Jack 4. COM Input Terminal 5. Other Input Terminals 6. mA Input Terminal 7. 20A/10A Input Terminal 8. Capacit

Turn the Meter on and off.

Press down the POWER to turn on the Meter. Press up the POWER to turn off the Meter. Press HOLD once to enter hold mode. Press HOLD again to exit hold mode. In Hold mode, is displayed and the present value is shown. Functional Buttons Below table indicated for information about the functional button operations l l l l l Display Symbols

UNI-T UT39A Make sure the Sleep Mode is not on if you found there

is no display on the LCD after turning on the Meter. Make sure the Low Battery Display is not on, otherwise false readings may be provided. Pay extra attention to the symbol which is located besides the input terminals of the Meter before carrying out measeurement. l l l A. DC Voltage Measurement (see figure 3) Warning To avoid harms to you or damages to the Meter from electric shock, pleas

If the value of voltage to be measured is unknown,

use the maximum measurement position (1000V) and reduce the range step by step until a satisfactory reading is obtained. The LCD displays “1” indicating the existing selected range is overloaded, it is required to select a higher range in order to obtain a correct reading. In each range, the Meter has an input impedance of approx. 10MΩ.This loading effect can
If the value of voltage to be measured is unknown, use the maximum measurement position (750V) and reduce the range step by step until a satisfactory reading is obtained. The LCD displays “1” indicating the existing selected range is overloaded, it is required to select a higher range in order to obtain a correct reading. In each range, the Meter has an input impedance of approx. 10MΩ. This loading effect can cause measurement errors

4. Break the current path to be tested. Connect the red

test lead to the more positive side of the break and the black test lead to the more negative side of the break. 5. Turn on power to the circuit. The measured value shows on the display. To measure current, do the following: 1. Turn off power to the circuit. Discharge all high-voltage capacitors. 2. Insert the red test lead into the mA or 20A or 10A terminal and the black tes

UNI-T Multimeter Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated For Device
UT81B

#RTZ4AI: UT81B Multimeter Operating manual

55 0.93 Mb 333 77 31-07-2026 view all
UT51-55

#64R55V: UT51-55 Multimeter Operating manual

20 1.46 Mb 1135 239 13-04-2026 view all
UT151D

Guide: UNI-T UT151D (HOQRO4, Upd.18-07-2026)

2 1128 271 18-07-2026 view all
UT531

#Q47P95: UT531 Multimeter Manual 

32 190 35 26-09-2026 view all
UT801

UT801 Operating manual - I534NV

2 0.53 Mb 1108 266 24-08-2026 view all
UT58D

#XL3I42: UT58D Multimeter Operating manual

2 371 90 03-05-2026 view all