Quadra-Fire QFP44 Owner's Manual
Read Online
Read the Quadra-Fire QFP44 Owner's Manual online using the built-in PDF viewer.
Text of the manual
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
1
Model(s):
QFP44
Owner’s Manual
Installation and Operation
R
Installation and service of this appliance should be performed
by qualified personnel. Hearth & Home Technologies
suggests NFI certifi ed or factory-trained professionals, or
technicians supervised by an NFI certifi ed professional.
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas:
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or
the gas supplier.
WARNING
DO NOT DISCARD THIS MANUAL
CAUTION
• Important operating and
maintenance instructions
included.
• Leave this manual with
party responsible for
use and operation.
• Read, understand and follow
these instructions for safe
installation and operation.
DO NOT
DISCARD
In the Commonwealth of Massachusetts installation
must be performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
HOT SURFACES!
Glass and other surfaces are hot during
operation and cool down.
WARNING
• CAREFULLY SUPERVISE children in same room as
appliance.
• Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
• Keep clothing, furniture, draperies and other combustibles
away.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
This appliance requires installation of a decorative front
with an integral barrier to prevent direct contact with
the fi xed glass panel. Do NOT operate the appliance
with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
2
Listing Label Information/Location
Model Name: ___________________________________________ Date purchased/installed: __________________
Serial Number: __________________________________________ Location on fi replace: _____________________
Dealership purchased from: _______________________________ Dealer Phone: __________________________
Notes: _______________________________________________________________________________________
_____________________________________________________________________________________________
A. Congratulations
Congratulations on selecting a Quadra-Fire gas fi replace, an
elegant and clean alternative to wood burning fi replaces. The
Quadra-Fire gas fi replace you have selected is designed to
provide the utmost in safety, reliability, and effi ciency.
As the owner of a new fi replace, you’ll want to read and
carefully follow all of the instructions contained in this
owner’s manual. Pay special attention to all cautions and
warnings.
This owner’s manual should be retained for future reference.
We suggest that you keep it with your other important
documents and product manuals.
The information contained in this owner’s manual, unless
noted otherwise, applies to all models and gas control
systems.
Your new Quadra-Fire gas fi replace will give you years of
durable use and trouble-free enjoyment. Welcome to the
Quadra-Fire family of fi replace products!
We recommend that you record the following pertinent
information about your fi replace.
The model information regarding your specifi c fi replace can be found on
the rating plate usually located in the control area of the fi replace.
Homeowner Reference Information
Read this manual before installing or operating this appliance.
Please retain this owner’s manual for future reference.
Quadra-Fire, a brand of Hearth & Home Technologies Inc.
7571 215th Street West, Lakeville, MN 55044
Not
Not for
for use
use with
with solid
solid fuel.
fuel.
(Ne
Ne doit
doit pas
pas entre
entre utilise
utilise avec
avec un
un combustible
combustible solide).
solide).
This
This appliance
appliance must
must be
be installed
installed in
in accordance
accordance with
with local
local codes,
codes, if if any;
any; if if not,
not, follow
follow ANSI
ANSI Z223.1
Z223.1
in
in the
the USA
USA or
or CAN/CGA
CAN/CGA B149
B149 installation
installation codes.
codes. (Installer
(Installer l’appareil
l’appareil selon
selon les
les codes
codes ou
ou reglements
reglements
locaux
locaux ou,
ou, en
en l’absence
l’absence de
de tels
tels reglements,
reglements, selon
selon les
les codes
codes d’installation
d’installation CAN/CGA-B149.)
CAN/CGA-B149.)
Type
Type of
of Gas
Gas (Sorte
(Sorte De
De Gaz)
Gaz):
NATURAL
TURAL GAS
GAS
MADE
MADE IN
IN USA
USA
Minimum
Minimum Permissible
Permissible Gas
Gas Supply
Supply for
for Purposes
Purposes of
of Input
Input Adjustment.
Adjustment.
Approved
Approved Minimum
Minimum (De
(De Gaz)
Gaz) Acceptable
Acceptable
0.0
0.0 in
in w.c.
w.c.
(Po.
(Po. Col.
Col. d’eau)
d’eau)
Maximum
Maximum Pressure
Pressure (Pression)
(Pression)
0.0
0.0 in
in w.c.
w.c.
(Po.
(Po. Col.
Col. d’eau)
d’eau)
Maximum
Maximum Manifold
Manifold Pressure
Pressure (Pression)
(Pression)
0.0
0.0 in
in w.c.
w.c.
(Po.
(Po. Col.
Col. d’eau)
d’eau)
Minimum
Minimum Manifold
Manifold Pressure
Pressure (Pression)
(Pression)
0.0
0.0 in
in w.c.
w.c.
(Po.
(Po. Col.
Col. d’eau)
d’eau)
Model:
Model:
(Modele):
(Modele):
Serial
Serial
(Serie):
(Serie):
ANSI
ANSI Z21XX-XXXX
Z21XX-XXXX · · CSA
CSA 2.XX-MXX
2.XX-MXX · · UL307B
UL307B
XXXXXXXX
XXXXXXXX
IN
IN CANADA
CANADA
ALTITUDE:
ALTITUDE:
0-0000
0-0000 FT.
FT.
0000-0000FT.
0000-0000FT.
MAX.
MAX. INPUT
INPUT BTUH:
BTUH:
00,000
00,000
00,000
00,000
MIN.
MIN. INPUT
INPUT BTUH:
BTUH:
00,000
00,000
00,000
00,000
ORIFICE
ORIFICE SIZE:
SIZE:
#XXXXX
#XXXXX
#XXXXX
#XXXXX
XXXXXXXX
XXXXXXXX
Total
Total Electrical
Electrical Requirements:
Requirements: 000Vac,
000Vac, 00Hz.,
00Hz., less
less than
than 00
00 Amperes
Amperes
R
Gas and Electric
Information
Serial Number
Type of Gas
Model Number
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
3
Safety Alert Key:
• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
• WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
• CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
• NOTICE: Used to address practices not related to personal injury.
Table of Contents
A. Congratulations
2
B. Limited Lifetime Warranty
5
1 Listing and Code Approvals
A. Appliance Certifi cation
7
B. Ceramic Glass Specifi cations
7
C. BTU Specifi cations
7
D. High Altitude Installations
7
E. Non-Combustible Materials Specifi cation
7
F.
Combustible Materials Specifi cation
7
G. Electrical Codes
7
H. Requirements for the Commonwealth
of Massachusetts
8
User Guide
2 Operating Instructions
A. Gas Fireplace Safety
9
B. Your Fireplace
9
C. Clear Space
10
D. Decorative Doors and Fronts
10
E. Fixed Glass Assembly
10
F.
Dashboard Control
10
G. Remote Operation
11
H. Before Lighting Fireplace
16
I.
Lighting Instructions (SP)
17
J.
After Fireplace is Lit
18
K. Frequently Asked Questions
18
3 Maintenance and Service
A. Maintenance Tasks-Homeowner
19
B. Maintenance Tasks-Qualifi ed Service Technician 20
Installer Guide
4 Getting Started
A. Typical Appliance System
21
B. Design and Installation Considerations
22
C. Tools and Supplies Needed
22
D. Inspect Appliance and Components
22
5 Framing and Clearances
A. Select Appliance Location
23
B. Construct the Appliance Chase
24
C. Clearances
24
D. Mantel and Wall Projections
25
6 Termination Locations
A. Vent Termination Minimum Clearances
26
7 Vent Information and Diagrams
A. Approved Pipe
28
B. Vent Table Key
28
C. Use of Elbows
28
D. Measuring Standards
28
E. Vent Diagrams
29
8 Vent Clearances and Framing
A. Pipe Clearances to Combustibles
33
B. Wall Penetration Framing
33
C. Install the Ceiling Firestop
34
D. Install Attic Insulation Shield
35
9 Appliance Preparation
A. Secure and Level the Appliance
36
10 Install Vent Pipe
A. Assemble Vent Sections
37
B. Assemble Slip Sections
38
C. Secure the Vent Sections
39
D. Disassemble Vent Sections
39
E. Install Metal Roof Flashing
40
F.
Assemble and Install Storm Collar
41
G. Install Vertical Termination Cap
42
H. Heat Shield Requirements for Horizontal
Termination
42
I.
Install Horizontal Termination Cap
43
11 Shrouds
A. HHT Shrouds
44
B. Field Constructed Shrouds
44
12 Gas Information
A. Fuel Conversion
46
B. Gas Pressure
48
C. Gas Connection
48
D. High Altitude Installations
48
13 Electrical Information
A. Wiring Requirements
49
B. Standing Pilot Ignition System Wiring
49
C. Optional Accessories Requirements
49
D. Electrical Service and Repair
50
E. Junction Box Installation
50
14 Finishing
A. Mantel and Wall Projections
51
B. Facing Material
52
C. Facing Template Removal
52
D. Mantel
52
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
4
= Contains updated information.
15 Appliance Setup
A. Remove Glass Assembly
53
B. Clean the Appliance
53
C. Install the Refractory
53
D. Adjust the Air Shutter
54
E. Adjust the Vertical Baffl e
55
F.
Install Logs, Ember Bed & Rockwool
55
G. Install Andirons
57
H. Place Lava Rock and Vermiculite
57
I.
Reinstall Glass
57
16 Troubleshooting
A. Standing Pilot Ignition System
58
17 Reference Materials
A. Appliance Dimension Diagram
60
B. Vent Components Diagrams
61
C. Service Parts
65
D. Optional Components
69
E. Contact Information
70
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
5
B. Limited Lifetime Warranty
4021-645C 12-29-10
Page 1 of 2
Hearth & Home Technologies Inc.
LIMITED LIFETIME WARRANTY
Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for
HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
WARRANTY COVERAGE:
HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership
of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance
will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered compo-
nents manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period,
HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its
obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product
itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty
is subject to conditions, exclusions and limitations as described below.
WARRANTY PERIOD:
Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage
begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent,
authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months
following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for
parts and labor for covered components is produced in the following table.
The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for
gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These
time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.
See conditions, exclusions, and limitations on next page.
Parts
Labor
Gas
Wood
Pellet
EPA
Wood
Coal
Electric Venting
X
X
X
X
X
X
X
All parts and material except as
covered by Conditions,
Exclusions, and Limitations
listed
X
X
X
Igniters, electronic components,
and glass
X
X
X
X
X
Factory-installed blowers
X
Molded refractory panels
X
Firepots and burnpots
5 years
1 year
X
X
Castings and baffles
7 years
3 years
X
X
X
Manifold tubes,
HHT chimney and termination
10
years
1 year
X
Burners, logs and refractory
Limited
Lifetime
3 years
X
X
X
X
X
Firebox and heat exchanger
X
X
X
X
X
X
X
All replacement parts
beyond warranty period
Warranty Period
HHT Manufactured Appliances and Venting
1 Year
Components Covered
3 years
2 years
90 Days
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
6
B. Limited Lifetime Warranty (continued)
4021-645C 12-29-10
Page 2 of 2
WARRANTY CONDITIONS:
7KLVZDUUDQW\RQO\FRYHUV++7DSSOLDQFHVWKDWDUHSXUFKDVHGWKURXJKDQ++7DXWKRUL]HGGHDOHURUGLVWULEXWRU$OLVWRI
++7DXWKRUL]HGGHDOHUVLVDYDLODEOHRQWKH++7EUDQGHGZHEVLWHV
7KLVZDUUDQW\LVRQO\YDOLGZKLOHWKH++7DSSOLDQFHUHPDLQVDWWKHVLWHRIRULJLQDOLQVWDOODWLRQ
&RQWDFW\RXULQVWDOOLQJGHDOHUIRUZDUUDQW\VHUYLFH,IWKHLQVWDOOLQJGHDOHULVXQDEOHWRSURYLGHQHFHVVDU\SDUWVFRQWDFW
WKHQHDUHVW++7DXWKRUL]HGGHDOHURUVXSSOLHU$GGLWLRQDOVHUYLFHIHHVPD\DSSO\LI\RXDUHVHHNLQJZDUUDQW\VHUYLFH
IURPDGHDOHURWKHUWKDQWKHGHDOHUIURPZKRP\RXRULJLQDOO\SXUFKDVHGWKHSURGXFW
&KHFNZLWK\RXUGHDOHULQDGYDQFHIRUDQ\FRVWVWR\RXZKHQDUUDQJLQJDZDUUDQW\FDOO7UDYHODQGVKLSSLQJFKDUJHV
IRUSDUWVDUHQRWFRYHUHGE\WKLVZDUUDQW\
This warranty is void if:
7KHDSSOLDQFHKDVEHHQRYHUILUHGRURSHUDWHGLQDWPRVSKHUHVFRQWDPLQDWHGE\FKORULQHIOXRULQHRURWKHUGDPDJLQJ
FKHPLFDOV2YHUILULQJFDQEHLGHQWLILHGE\EXWQRWOLPLWHGWRZDUSHGSODWHVRUWXEHVUXVWFRORUHGFDVWLURQEXEEOLQJ
FUDFNLQJDQGGLVFRORUDWLRQRIVWHHORUHQDPHOILQLVKHV
7KHDSSOLDQFHLVVXEMHFWHGWRSURORQJHGSHULRGVRIGDPSQHVVRUFRQGHQVDWLRQ
7KHUHLVDQ\GDPDJHWRWKHDSSOLDQFHRURWKHUFRPSRQHQWVGXHWRZDWHURUZHDWKHUGDPDJHZKLFKLVWKHUHVXOWRIEXW
QRWOLPLWHGWRLPSURSHUFKLPQH\RUYHQWLQJLQVWDOODWLRQ
LIMITATIONS OF LIABILITY:
7KHRZQHU¶VH[FOXVLYHUHPHG\DQG++7¶VVROHREOLJDWLRQXQGHUWKLVZDUUDQW\XQGHUDQ\RWKHUZDUUDQW\H[SUHVVRU
LPSOLHGRULQFRQWUDFWWRUWRURWKHUZLVHVKDOOEHOLPLWHGWRUHSODFHPHQWUHSDLURUUHIXQGDVVSHFLILHGDERYH,QQR
HYHQWZLOO++7EHOLDEOHIRUDQ\LQFLGHQWDORUFRQVHTXHQWLDOGDPDJHVFDXVHGE\GHIHFWVLQWKHDSSOLDQFH6RPHVWDWHV
GRQRWDOORZH[FOXVLRQVRUOLPLWDWLRQRILQFLGHQWDORUFRQVHTXHQWLDOGDPDJHVVRWKHVHOLPLWDWLRQVPD\QRWDSSO\WR\RX
7KLVZDUUDQW\JLYHV\RXVSHFLILFULJKWV\RXPD\DOVRKDYHRWKHUULJKWVZKLFKYDU\IURPVWDWHWRVWDWH(;&(3772
7+((;7(173529,'('%</$:++70$.(612(;35(66:$55$17,(627+(57+$17+(:$55$17<
63(&,),('+(5(,17+('85$7,212)$1<,03/,(':$55$17<,6/,0,7('72'85$7,212)7+(
(;35(66(':$55$17<63(&,),('$%29(
WARRANTY EXCLUSIONS:
7KLVZDUUDQW\GRHVQRWFRYHUWKHIROORZLQJ
&KDQJHVLQVXUIDFHILQLVKHVDVDUHVXOWRIQRUPDOXVH$VDKHDWLQJDSSOLDQFHVRPHFKDQJHVLQFRORURILQWHULRUDQG
H[WHULRUVXUIDFHILQLVKHVPD\RFFXU7KLVLVQRWDIODZDQGLVQRWFRYHUHGXQGHUZDUUDQW\
'DPDJHWRSULQWHGSODWHGRUHQDPHOHGVXUIDFHVFDXVHGE\ILQJHUSULQWVDFFLGHQWVPLVXVHVFUDWFKHVPHOWHGLWHPV
RURWKHUH[WHUQDOVRXUFHVDQGUHVLGXHVOHIWRQWKHSODWHGVXUIDFHVIURPWKHXVHRIDEUDVLYHFOHDQHUVRUSROLVKHV
5HSDLURUUHSODFHPHQWRISDUWVWKDWDUHVXEMHFWWRQRUPDOZHDUDQGWHDUGXULQJWKHZDUUDQW\SHULRG7KHVHSDUWV
LQFOXGHSDLQWZRRGSHOOHWDQGFRDOJDVNHWVILUHEULFNVJUDWHVIODPHJXLGHVOLJKWEXOEVEDWWHULHVDQGWKHGLVFRORU-
DWLRQRIJODVV
0LQRUH[SDQVLRQFRQWUDFWLRQRUPRYHPHQWRIFHUWDLQSDUWVFDXVLQJQRLVH7KHVHFRQGLWLRQVDUHQRUPDODQGFRP-
SODLQWVUHODWHGWRWKLVQRLVHDUHQRWFRYHUHGE\WKLVZDUUDQW\
'DPDJHVUHVXOWLQJIURPIDLOXUHWRLQVWDOORSHUDWHRUPDLQWDLQWKHDSSOLDQFHLQDFFRUGDQFHZLWKWKHLQVWDOODWLRQ
LQVWUXFWLRQVRSHUDWLQJLQVWUXFWLRQVDQGOLVWLQJDJHQWLGHQWLILFDWLRQODEHOIXUQLVKHGZLWKWKHDSSOLDQFHIDLOXUHWR
LQVWDOOWKHDSSOLDQFHLQDFFRUGDQFHZLWKORFDOEXLOGLQJFRGHVVKLSSLQJRULPSURSHUKDQGOLQJLPSURSHURSHUD-
WLRQDEXVHPLVXVHFRQWLQXHGRSHUDWLRQZLWKGDPDJHGFRUURGHGRUIDLOHGFRPSRQHQWVDFFLGHQWRULPSURSHUO\
LQFRUUHFWO\SHUIRUPHGUHSDLUVHQYLURQPHQWDOFRQGLWLRQVLQDGHTXDWHYHQWLODWLRQQHJDWLYHSUHVVXUHRUGUDIWLQJ
FDXVHGE\WLJKWO\VHDOHGFRQVWUXFWLRQVLQVXIILFLHQWPDNHXSDLUVXSSO\RUKDQGOLQJGHYLFHVVXFKDVH[KDXVWIDQVRU
IRUFHGDLUIXUQDFHVRURWKHUVXFKFDXVHVXVHRIIXHOVRWKHUWKDQWKRVHVSHFLILHGLQWKHRSHUDWLQJLQVWUXFWLRQV
LQVWDOODWLRQRUXVHRIFRPSRQHQWVQRWVXSSOLHGZLWKWKHDSSOLDQFHRUDQ\RWKHUFRPSRQHQWVQRWH[SUHVVO\DXWKRUL]HG
DQGDSSURYHGE\++7PRGLILFDWLRQRIWKHDSSOLDQFHQRWH[SUHVVO\DXWKRUL]HGDQGDSSURYHGE\++7LQZULWLQJ
DQGRULQWHUUXSWLRQVRUIOXFWXDWLRQVRIHOHFWULFDOSRZHUVXSSO\WRWKHDSSOLDQFH
1RQ++7YHQWLQJFRPSRQHQWVKHDUWKFRPSRQHQWVRURWKHUDFFHVVRULHVXVHGLQFRQMXQFWLRQZLWKWKHDSSOLDQFH
$Q\SDUWRIDSUHH[LVWLQJILUHSODFHV\VWHPLQZKLFKDQLQVHUWRUDGHFRUDWLYHJDVDSSOLDQFHLVLQVWDOOHG
++7¶VREOLJDWLRQXQGHUWKLVZDUUDQW\GRHVQRWH[WHQGWRWKHDSSOLDQFH¶VFDSDELOLW\WRKHDWWKHGHVLUHGVSDFH,QIRUPD-
WLRQLVSURYLGHGWRDVVLVWWKHFRQVXPHUDQGWKHGHDOHULQVHOHFWLQJWKHSURSHUDSSOLDQFHIRUWKHDSSOLFDWLRQ&RQVLGHU-
DWLRQPXVWEHJLYHQWRDSSOLDQFHORFDWLRQDQGFRQILJXUDWLRQHQYLURQPHQWDOFRQGLWLRQVLQVXODWLRQDQGDLUWLJKWQHVVRI
WKHVWUXFWXUH
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
7
C. BTU Specifi cations
MODELS: QFP44
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Vented Gas Fireplace Heater
STANDARD: ANSI Z21.88b-2008 • CSA 2.33b-2008
E. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750 ºC and UL763 shall be
considered non-combustible materials.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental
room heat or as a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility or
authorities having jurisdiction.
When installing above 2000 feet elevation:
•
In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
•
In CANADA: Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
Check with your local gas utility to determine proper
orifi ce size.
1
1 Listing and Code Approvals
A. Appliance Certifi cation
G. Electrical Codes
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
•
A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
B. Ceramic Glass Specifi cations
This appliance is equipped with 5 mm ceramic glass. Re-
place glass with 5 mm ceramic glass. Please contact your
dealer for replacement glass.
F. Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed
paper, plant fi bers, plastics, or other material that can ig-
nite and burn, whether fl ame proofed or not, or plastered
or unplastered shall be considered combustible materials.
QFP44 Series
IPI
Max/Min Input Rate (NG) Both Burners
70,000 / 47,000
Max/Min Input Rate (NG) Front Burner
19,000 / 13,500
Max/Min Input Rate (LP) Both Burners
67,000 / 51,000
Max/Min Input Rate (LP) Front Burner
21,000 / 14,500
Orifi ce Size (NG) Front
#46/.084 in./2.13 mm
Orifi ce Size (NG) Rear
#18/.169 in./4.29 mm
Orifi ce Size (LP) Front
#56/.046 in./1.17 mm
Orifi ce Size (LP) Rear
#46/.084 in./2.13 mm
NOTICE: This installation must conform with local codes
or, in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and
Propane Installation Code, CSA B149.1.
•
A manufactured home (USA only) or mobile home OEM
installation must conform with the (U.S.) Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280 or, when such a standard is not applicable, the
Standard for Fire Safety Criteria for Manufactured Home
Installation Sites and Communities, ANSI/NFPA 501A,
in the United States, or the Mobile Homes Standard,
CAN/CSA Z240 MH Series in Canada.
•
This appliance complies with the installation requirements
for HUD.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
8
H. Requirements for the Commonwealth of
Massachusetts
For all side wall horizontally vented gas fueled equipment
installed in every dwelling, building or structure used in
whole or in part for residential purposes, including those
owned or operated by the Commonwealth and where the
side wall exhaust vent termination is less than seven (7)
feet above fi nished grade in the area of the venting, in-
cluding but not limited to decks and porches, the following
requirements shall be satisfi ed:
Installation of Carbon Monoxide Detectors
At the time of installation of the side wall horizontal
vented gas fueled equipment, the installing plumber or
gas fi tter shall observe that a hard wired carbon mon-
oxide detector with an alarm and battery back-up is
installed on the fl oor level where the gas equipment is
to be installed. In addition, the installing plumber or gas
fi tter shall observe that a battery operated or hard wired
carbon monoxide detector with an alarm is installed on
each additional level of the dwelling, building or struc-
ture served by the side wall horizontal vented gas fueled
equipment. It shall be the responsibility of the property
owner to secure the services of qualifi ed licensed profes-
sionals for the installation of hard wired carbon monoxide
detectors.
In the event that the side wall horizontally vented gas
fueled equipment is installed in a crawl space or an attic,
the hard wired carbon monoxide detector with alarm and
battery back-up may be installed on the next adjacent
fl oor level.
In the event that the requirements of this subdivision can
not be met at the time of completion of installation, the
owner shall have a period of thirty (30) days to comply
with the above requirements; provided, however, that dur-
ing said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
Approved Carbon Monoxide Detectors
Each carbon monoxide detector as required in accor-
dance with the above provisions shall comply with NFPA
720 and be ANSI/UL 2034 listed and IAS certifi ed.
Signage
A metal or plastic identifi cation plate shall be permanently
mounted to the exterior of the building at a minimum
height of eight (8) feet above grade directly in line with
the exhaust vent terminal for the horizontally vented gas
fueled heating appliance or equipment. The sign shall
read, in print size no less than one-half (1/2) in. in size,
“GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS”.
Inspection
The state or local gas inspector of the side wall horizon-
tally vented gas fueled equipment shall not approve the
installation unless, upon inspection, the inspector ob-
serves carbon monoxide detectors and signage installed
in accordance with the provisions of 248 CMR 5.08(2)(a)1
through 4.
Exemptions
The following equipment is exempt from 248 CMR
5.08(2)(a)1 through 4:
•
The equipment listed in Chapter 10 entitled “Equipment
Not Required To Be Vented” in the most current edition
of NFPA 54 as adopted by the Board; and
•
Product Approved side wall horizontally vented gas
fueled equipment installed in a room or structure
separate from the dwelling, building or structure used
in whole or in part for residential purposes.
MANUFACTURER REQUIREMENTS
Gas Equipment Venting System Provided
When the manufacturer of Product Approved side wall
horizontally vented gas equipment provides a venting
system design or venting system components with the
equipment, the instructions provided by the manufacturer
for installation of the equipment and the venting system
shall include:
•
Detailed instructions for the installation of the venting
system design or the venting system components;
and
•
A complete parts list for the venting system design or
venting system.
Gas Equipment Venting System NOT Provided
When the manufacturer of a Product Approved side
wall horizontally vented gas fueled equipment does not
provide the parts for venting the fl ue gases, but identi-
fi es “special venting systems”, the following requirements
shall be satisfi ed by the manufacturer:
•
The referenced “special venting system” instructions
shall be included with the appliance or equipment
installation instructions; and
•
The “special venting systems” shall be Product
Approved by the Board, and the instructions for that
system shall include a parts list and detailed installation
instructions.
A copy of all installation instructions for all Product Ap-
proved side wall horizontally vented gas fueled equip-
ment, all venting instructions, all parts lists for venting
instructions, and/or all venting design instructions shall
remain with the appliance or equipment at the completion
of the installation.
See Gas Connection section for additional Common-
wealth of Massachusetts requirements.
Note: The following requirements reference various
Massachusetts and national codes not contained in this
document.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
9
Decorative Doors
(not shown)
Section 2.E.
Fixed Glass Assembly
Section 2.F.
Mantel
Hearth
(not required)
Dashboard
Control
Section 2.G.
Clear Space
Section 2.D.
Figure 2.1 General Operating Parts
B. Your Fireplace
WARNING! DO NOT operate fi replace before reading and
understanding operating instructions. Failure to operate
fi replace according to operating instructions could cause
fi re or injury.
If you expect that small children or vulnerable adults may
come into contact with this fi replace, the following precau-
tions are recommended:
A. Gas Fireplace Safety
•
Install a physical barrier such as:
-
A decorative fi rescreen.
-
Adjustable safety gate.
•
Install a switch lock or a wall/remote control with child
protection lockout feature.
•
Keep remote controls out of reach of children.
•
Never leave children alone near a hot fi replace, whether
operating or cooling down.
•
Teach children to NEVER touch the fi replace.
•
Consider not using the fi replace when children will be
present.
Contact your dealer for more information, or visit: www.
hpba.org/safety-information.
To prevent unintended operation when not using your
fi replace for an extended period of time (summer months,
vacations, trips, etc):
•
Remove batteries from remote controls.
•
Turn off wall controls.
•
Unplug 3 volt adapter plug and remove batteries on IPI
models.
•
Turn off gas controls valve on standing pilot models.
When lighting the pilot light on fi replaces with a standing
pilot, remove the fi xed glass assembly so you can detect
presence of residual gas build-up. See Standing Pilot
Lighting instructions and Maintenance Tasks.
2
2 Operating Instructions
User Guide
HOT SURFACES!
Glass and other surfaces are hot
during operation and cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in
WARNING
same room as appliance.
• Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
• Keep clothing, furniture, draperies and other
combustibles away.
This appliance requires the installation of a
decorative front with an integral barrier to prevent
direct contact with the fi xed glass panel. Do NOT
operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
10
Clear Space
3 ft (0.91 m)
in front of
appliance
C. Clear Space
WARNING! DO NOT place combustible objects in front of
the fi replace or block louvers. High temperatures may start
a fi re. See Figure 2.2.
Avoid placing candles and other heat-sensitive objects on
mantel or hearth. Heat may damage these objects.
Figure 2.2
Clear Space
E. Fixed Glass Assembly
See Section 15.A.
D. Decorative Doors and Fronts
WARNING! Risk of Fire! Install ONLY doors or fronts
approved by Hearth & Home Technologies. Unapproved
doors or fronts may cause fi replace to overheat.
This appliance requires the installation of a decorative front
with an integral barrier to prevent direct contact with the
fi xed glass panel. Do NOT operate the appliance with the
barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install
one.
For more information refer to the instructions supplied
with your decorative door or front.
F. Dashboard Control
Figure 2.3
Dashboard Control
Valve Control
This knob is used to control the gas to the appliance and
for starting the pilot. There are three positions, ON, OFF,
PILOT. The indicator on the valve indicates the position of
the knob.
Pilot Ignitor
This unit is equipped with an electronic ignitor for the
pilot. When the valve control knob is turned to the PILOT
position and fully depressed, the ignitor will begin spark-
ing and light the pilot. After the pilot is lit, release the
knob slightly to stop the ignitor from sparking but continue
holding the knob in for 30 seconds to establish the pilot.
Release the knob and the pilot should stay lit.
Rear Burner Switch
The rear burner can be shut off completely with the
switch, allowing the front burner to operate in either high
or low mode for limited heat output.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
11
Ignitor Battery Box
By pulling the drawer forward, the ignitor battery box can
be accessed to replace the AA battery as necessary. See
Figure 2.4.
Ignitor Battery Box
Figure 2.4
Accessing the Ignitor Battery Box.
G. Remote Operation
This remote control kit has a hand held transmitter that
can be used as a remote on/off or as a thermostat. The
transmitter display shows the current room temperature,
target temperature, timer setting, on/off status, low battery
indicator, current time, burner/valve operation and fan
operation. Electrical ratings for the receiver are: 110 VAC,
60 Hz, 6 W.
Warning! CHANGES OR MODIFICATIONS TO THIS
UNIT NOT EXPRESSLY APPROVED BY THE PARTY
RESPONSIBLE FOR COMPLIANCE COULD VOID THE
USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
Note: This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference
in a residential installation. This equipment generates,
uses , and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference
by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and
receiver.
•
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
•
Contact the dealer or an experienced radio TV
technician for help.
Canadian Equipment Requirements
This digital apparatus does not exceed the (Class A/
Class B) limits for radio noise emissions from digital ap-
paratus set out in the Radio Interference Regulations of
the Canadian Department of Communications. Le present
appareil numerique n’emet pas de bruits radioelectriques
depassant les limites applicables aux appareils nume-
riques (de la class A/de la class B) prescrites dans le
Reglement sur le brouillage radioelectrique edicte par le
ministere des Communications du Canada.
This device complies with RSS-210 of Industry and Sci-
ence Canada. Operation is subject to the following two
conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, includ-
ing interference that may cause undesired operation of
the device.
FCC REQUIREMENTS
Ignitor Battery Box
By pulling the drawer forward, the ignitor battery box can
be accessed to replace the AA battery as necessary. See
Figure 13.2.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
12
Remote Receiver
The remote receiver has a 3-position slide switch:
OFF/REMOTE/ON (see Figure 2.5).
NOTE: The remote receiver will only respond to the
transmitter when the 3-position slide button on the remote
receiver is in the Remote position. If the system does
not respond to the transmitter on initial use, see section
Matching Security Codes.
OFF-REMOTE-ON
GROUND
VALVE
FLAME
CONTROL
LEARN
Receptacle on back
3-position switch
Figure 2.5
Remote Receiver
•
With the slide switch in the ON position, the system is
on.
•
With the slide switch in the REMOTE position, the system
only operates if the remote receiver receives commands
from the transmitter.
•
With the slide switch in the OFF position, the system is
off.
NOTE: The slide switch should be placed in the OFF
position if you will be away from your home for an extended
period of time. Placing the switch in the OFF position also
functions as a safety “lock out” by turning the system off
and rendering the remote receiver inoperative.
Transmitter
Important: Before operating remote control, transmitter
and receiver must have matching security codes. See
section ‘Matching Security Codes’.
Important: Review ‘Thermo-Updating/Communication-
Safety Features’ under ‘Transmitter Safety Features’
section. Communication Safety features shut down the
fireplace system when a potentially unsafe condition
exists.
Important: Review ‘Auto Shutdown’ section. This safety
feature shuts down the fi replace after 9 hours of continuous
operation, in ON mode only. Important: New or fully charged
batteries are essential for proper operation of the multi-
function transmitter. The transmitter operates on 2 AAA-size
1.5V batteries. Use Alkaline batteries for longer battery life
and maximum operational performance.
Insert 2 AAA-size 1.5V batteries into the battery compart-
ment on the back of the transmitter. When the batteries
are correctly inserted, the screen will display numbers
(see Figure 2.6 for LCD Display Screen).
NOTE: If the transmitter is activated from a very cold
condition it may be necessary to allow the transmitter to
stabilize to room temperature (could take up to 15 minutes)
before accurate room temperatures are displayed on the
screen.
NOTE: LCD screen is equipped with a “backlite” for
easier viewing of LCD screen. Backlite illuminates when
a function button is depressed. After 5 seconds elapses,
LCD screen will return to its normal state.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
13
1. LOW - Battery power low. Replace batteries within two weeks.
2. TIMER - Indicates time remaining before system shuts off, when timer-
programmed, 9 - hour maximum setting.
3. MODE - Indicates operation MODE of system. ON indicates the system is
on, either manually or thermostatically. THERMO indicates the system will
automatically cycle ON/OFF, depending on programmed SET temperature.
OFF indicates the entire system is turned off.
4. SET - Indicates desired SET room temperature for THERMO operation.
5. FLAME - Single or double Flame/Hi icon indicates burner/valve operational.
6. CLOCK - Indicates the current time in AM/PM.
7. ROOM - Indicates CURRENT room temperature.
8. °F - Indicates degrees Fahrenheit (°C indicates degrees
Celsius).
9. FAN - Indicates fan is on or programmed to come on.
Three speed settings are available.
Figure 2.6
Transmitter LCD Display Screen
Matching Security Codes
It may be necessary to program the remote receiver to
the security code of the transmitter upon initial use, if bat-
teries are replaced, or if a replacement transmitter is pur-
chased from your dealer. To program the remote receiver:
•
Set the slide button on the receiver to the REMOTE
position.
•
Push the LEARN button (one beep will be heard) on the
top of the remote receiver.
•
Then press the MODE button on the transmitter.
Several beeps indicate the transmitter’s code has been
programmed into the receiver. When an existing receiver
is matched to a new transmitter, the new security code
will overwrite the old one.
If you are unsuccessful in matching the security code on
the fi rst attempt, wait 1-2 minutes before trying again.
NOTE: When the LEARN button is depressed, “beeping”
sounds should be heard. If no “beeping” is heard check to
see that the receiver has 110-120VAC power to it.
Operating Instructions
To operate the system, press the MODE button (Figure
13.4) on the transmitter to select the operational MODE
desired.
•
ON indicates the system is on, either manually, timed
or thermostatically.
•
THERMO indicates the system will automatically cycle
ON/OFF, depending on programmed set temperature.
•
OFF indicates the entire system is turned off.
Transmitter Settings
Flip open the plastic cover on the front of the transmitter
to expose the “SET” buttons.
NOTE: Flashing numbers on the display indicate the
system is waiting for input, such as using the UP and
DOWN buttons to program a new setting. If no change is
made to fl ashing digits within 15 seconds, the system will
complete the procedure last programmed and reset the
display to its normal state.
Setting the Clock
•
Press and hold the TIMER/TIME button on the transmitter
for more than two seconds. The hour digit(s) will begin
fl ashing (see Figure 13.4, Location #6).
•
Press the UP or DOWN button until the desired hour is
displayed in AM or PM.
•
After setting the desired hour, press and release the
TIMER/TIME button again to set the minutes; the minute
digits will begin fl ashing.
•
Press the UP or DOWN button until the desired minutes
are displayed.
•
Press and hold the TIMER/TIME button again for more
than two seconds. The time digits will cease fl ashing,
indicating the clock has been successfully set. You may
also press the SET button on the transmitter to stop the
time digits from fl ashing and set the time.
MODE
SET
UP
TIMER
DOWN
FAN
FLAME
TIME
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
14
Setting °F/°C Scale
The factory setting for temperature is degrees Fahrenheit
°F). To change this setting to degrees Centigrade (°C):
•
Remove the battery cover on the back of the transmitter
and locate the “setting button” at the top center of battery
compartment (see Figure 2.7).
•
Push setting button and °F will begin fl ashing on the
LCD screen (see Figure 13.4, Location #8).
•
Push the DOWN button on the transmitter to change °F
to °C.
•
Push “setting button” on transmitter and Centigrade (°C)
degree readings will display on LCD screen.
•
Repeat this process to change back to Fahrenheit (°F)
reading, this time pushing the UP button.
NOTE: LCD screen will return to normal state if setting
button is not pushed within 15 seconds.
Setting Desired Room Temperature - Ther-
mo Operations
This remote control system can be thermostatically
controlled when the transmitter is in the THERMO
mode. (THERMO must be displayed on the screen). The
transmitter will “sense” the room temperature every two
minutes automatically turning the fi replace ON or OFF
thermostatically.
To set the desired room temperature:
•
Press the MODE button to place the transmitter into
THERMO mode. THERMO ON or OFF will display.
•
Press the UP or DOWN button to select the desired
room temperature. The highest SET temperature is 99° F
(32° C). The lowest SET temperature is 45° F (6° C).
When the transmitter is in the THERMO mode, it should
be kept away from direct sources of heat such as fi replac-
es, incandescent lighting and direct sunlight. Leaving the
transmitter in direct sunlight, for example, will cause it to
read the room temperature higher than it actually is.
NOTE: To prevent repeated thermo-cycling of the gas
appliance, the sensing unit in the transmitter will only
activate the remote receiver when the temperature change
exceeds 2° F (1° C) above or below the SET (desired)
temperature.
Setting the Countdown Timer
This remote control system can operate with a built-in
countdown timer when the transmitter is in the ON or
THERMO modes (THERMO or ON must be displayed on
the LCD screen).
•
Press and release the TIMER/TIME button on the
transmitter. The word TIMER and 0:15 fl ash on the
screen (see Figure 2.6, Location #2).
•
Press the UP and DOWN button to begin advancing
through each of the countdown time options. Available
countdown times are 15 min, 30 min, 45 min, 1 hour, 1 hr
30 min, and each additional half hour up to nine hours.
•
To set the TIMER, press the SET button on the
transmitter. If the system is ON, it will remain on until
the “time” has expired. If the system is in the THERMO
mode, it will cycle on and off as the room temperature
requires until the “time” has expired.
NOTE: When the timer is used in the THERMO mode,
the THERMO operation will discontinue when the “time”
has expired.
Operating the Fan - Operates in ON or THER-
MO mode
This remote control system has the capability of operat-
ing a 110 VAC fan or blower system that may be included
with your gas fi replace. The fan will only operate when the
transmitter is in the ON or THERMO mode. (THERMO or
ON must be displayed on LCD screen).
•
To turn fan ON, press and release the FAN button on
the transmitter (see Figure 2.6, Location #9). The fan
will operate at HI speed, and fan blade icon will appear
on LCD screen.
•
To change fan speed to MED, press and release FAN
button again. To change fan speed to LO, press and
release FAN button again.
•
To turn fan OFF, press and release FAN button again.
Fan blade icon will disappear from LCD screen.
Figure 2.7
Setting Button/Childproof Lockout
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
15
Adjusting the Flame Height -
Operates in ON or THERMO mode
This remote control system allows the user to control
the height of the FLAME when the gas valve is factory
equipped with a FLAME CONTROLLER.
•
Press and release FLAME button to change fl ame height
to HI (see Figure 2.6, Location #5), a second fl ame icon
appears.
•
Press again to return fl ame to normal state.
Low/Battery Indicator
An “X” outlined by a battery on the right side of the LCD
screen will appear when battery power has dropped sig-
nifi cantly. At this time, approximately two weeks of battery
power remains.
Child Proof Lockout (CP)
The transmitter contains a “Child Proof” lockout feature
that prevents unauthorized use of the remote control. To
access the “Child Proof” activation button, remove cover
on BACK of transmitter. To activate LOCKOUT:
•
Press and hold in the “setting button” for 5 seconds
(see Figure 2.7). The letters CP will display on the LCD
screen). This prevents the activation of fi replace. When
any function button is pressed ON/OFF etc. the letter
CP will display on the LCD screen.
To deactivate LOCKOUT:
•
Press and hold in the “setting button” for 5 seconds. The
LCD will display CP until 5 seconds have elapsed, and
then the LCD screen will return to its normal state.
Transmitter Safety Features
It is recommended that the TRANSMITTERS always be
located within a 20 foot operating range of the fi replace,
preferably in the same room in which the fi replace system
is located. The TRANSMITTER features several safety
features that alert the user when the TRANSMITTER is
placed outside the 20 foot normal operating range.
Thermo-Updating and Communication-Safety
Features
This remote control has a COMMUNICATION-SAFETY
function built into its software. It provides an extra margin
of safety when the TRANSMITTER is out of the normal
20 foot operating range of the receiver. It is also activated
when the batteries become weak or are removed from
the transmitter.
In the THERMO-UPDATING feature (only in the THER-
MO or TIMER modes) the transmitter normally reads the
ROOM temperature every 2 minutes. In addition to check-
ing the temperature, the transmitter sends a signal to the
receiver indicating that the transmitter and its batteries
are still active.
In the COMMUNICATION-SAFETY feature, at all times
and in all OPERATING MODES the transmitter sends a
signal every 15 minutes to the receiver, indicating that the
transmitter is within the normal operating range of 20 feet.
Should the receiver NOT receive a transmitter signal
every 15 minutes (COMMUNICATION-SAFETY feature),
the RECEIVER will begin a 2 HOUR (120 minute) count-
down timing function. If during this 2 hour period, the re-
ceiver does not receive a signal from the transmitter, the
RECEIVER will shut down the fi replace being controlled
by the receiver. The RECEIVER will then emit a series of
rapid “beeps”. Then, after 10 rapid “beeps”, the RECEIV-
ER will continue to emit a single “beep” every 4 seconds
until a transmitter signal is again received. The intermit-
tent 4 second beeping will go on indefi nitely until reset.
To “reset” the RECEIVER and operate the fi replace sys-
tem:
•
Press the MODE button on the transmitter. The word ON
must display on the LCD screen. The COMMUNICATION
-SAFETY operation is overridden and the system will
return to normal operation depending on the MODE
selected at the transmitter. We recommend the user
check the batteries in the TRANSMITTER to make sure
the voltage is no less than 2.7 volts.
Auto Shutdown
This remote control has an Auto Shutdown feature incor-
porated into its system. When the transmitter MODE is
in the ON position the fi replace will continuously operate
for 9 hours. After 9 hours, the fi replace will shut down. To
relight the fi replace:
•
Press the MODE button. The fi replace will operate
continuously for up to 9 hours before Auto Shutdown
repeats cycle. The Auto Shutdown signal comes from
the transmitter. The transmitter must be positioned within
a 20 ft operating range for the Auto Shutdown feature to
operate.
System Check
Light the appliance following the lighting instructions that
came with the fi replace. Confi rm that the pilot fl ame is on.
It must be in operation for the main gas valve to operate.
•
Slide the 3-position button on the remote receiver to the
ON position. The main gas fl ame (i.e., the fi re) should
ignite.
•
Slide the button to OFF. The fl ame should extinguish
(the pilot fl ame will remain on).
•
Slide the button to REMOTE (the center position), then
press the MODE button on the transmitter to change the
system to ON. The main gas fl ame should ignite.
•
Press the MODE button on the transmitter to change the
system to OFF. The fl ame should extinguish (the pilot
fl ame will remain on).
•
Press the MODE button on the transmitter to change
the system to THERMO.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
16
H. Before Lighting Fireplace
Before operating this fi replace for the fi rst time, have a
qualifi ed service technician:
•
Verify all shipping materials have been removed from
inside and/or underneath the fi rebox.
•
Review proper placement of logs, rockwool and/or other
decorative materials.
•
Check the wiring.
•
Check the air shutter adjustment.
•
Ensure that there are no gas leaks.
•
Ensure that the glass is sealed and in the proper position
and that the integral barrier is in place.
WARNING! Risk of Fire or Asphyxiation! DO NOT oper-
ate fi replace with fi xed glass assembly removed.
•
Advance the SET temperature on the transmitter to a
temperature of at least 2° F (1° C) above the ROOM
temperature displayed on the LCD screen and the
system fl ame will ignite.
•
Set the SET temperature to at least 2° F (1° C)
below the room temperature and the system fl ame
will extinguish. Thereafter, it should continue to cycle
on and off thermostatically approximately every two
minutes as the ROOM temperature changes, but only
when the temperature differential between ROOM and
SET temperatures differs at least 2° F (1° C). The 2° F
differential is the factory setting.
Timer Operation
The countdown timer will operate in either the manual ON
or THERMO mode. Once the fi replace system is in an
operating mode, set the countdown timer to turn off in 15
minutes. The timer function will allow operation to contin-
ue until the “countdown time” on the LCD screen expires.
After 15 minutes elapse, the system should turn off.
General Information
Transmitter Wall Bracket
The transmitter can be hung on a wall using the bracket
provided. Locate the bracket on an inside wall suffi ciently
far away from direct sources of heat such as a fi replace,
incandescent lighting, or sunlight so it detects ambi-
ent room temperatures, not a single heat source. If the
bracket is installed on a solid wood wall, drill 1/8” pilot
holes and install with the screws provided. If it is installed
on a plaster/wallboard wall, fi rst drill two 1/4” holes into
the wall, then use a hammer to tap in the two plastic
wall anchors fl ush with the wall, then install the screws
provided.
Battery Life
Life expectancy of the batteries in the transmitter should
be at least 12 months. Check batteries annually. When
the transmitter no longer operates the remote receiver
from a distance it did previously (i.e., the transmitter’s
range has decreased) the batteries should be checked.
Specifi cations
Batteries: Transmitter - 3V 2 ea.; AAA 1.5V, Alkaline
Remote - 110-120 VAC; 60Hz
Operating Frequency: 303.8 MHZ
FCC ID No.’s: Transmitter - K9L300ITX
Receiver - K9L3003RX
Canadian ISC ID No.’s: Transmitter - 2439 102 760
Receiver - 2439 102 760A
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
17
1. Turn unit off with remote.
2. Turn off all electric power to the appliance if service is to be performed.
3. Push in gas control knob slightly and turn clockwise to "OFF" position.
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
A. This appliance has a pilot that must be lit manually. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier
than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electric switch, do not use any phone in your building.
* Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
* If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try
to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control which has been under water.
1. STOP! Read the safety information above on this label.
2. Set the thermostat to the lowest setting (if applicable) and turn off
the switch at the control panel.
3. Disconnect the power from the appliance.
4. Open the door of the appliance. May need to remove face/front first.
5. Push in gas control knob slightly and turn clockwise to the "OFF"
position. Do not force.
6. Wait five (5) minutes to clear out any gas. Smell for gas, including near the floor. If you smell gas, STOP! Follow "B" of the
safety information above. If you don't smell gas go to the next step.
7. Push gas control knob in and turn counterclockwise to the pilot position. NOTE: Knob cannot be turned unless knob is
pushed in slightly. Do not force.
8. PIEZO IGNITER: Press down on the gas control knob in pilot position and simultaneously press the piezo igniter.
(This may take many repetitions for lighting.)
ELECTRONIC IGNITER: If the unit is equipped with an electronic igniter it should begin sparking right away.
9. The pilot should be visible through the door opening.
10. After the pilot is lit, continue holding control knob down for approximately
30 seconds. Release the knob and it will pop back up. Pilot should remain lit.
If it goes out, repeat steps 7 through 9.
* If the knob does not pop up when released, stop and immediately call your
service technician or gas supplier.
* If the pilot will not stay lit after several tries, turn the gas control knob
clockwise to "OFF" and call your service technician or gas supplier.
11. Reinstall door and face. Wait five minutes to allow pilot flame to stabilize and
establish proper draft.
12. Push down and turn gas control knob counterclockwise to "ON".
13. Use remote transmitter to operate the unit. If thermostat is to be used, leave switch in "OFF" position and set the thermostat to
desired setting.
14. Reconnect electrical power to appliance.
MILLIVOLT
GENERATOR
PILOT HOOD
THERMOCOUPLE
WARNING: If you do not follow these instructions exactly, a fire or explosion may
result causing property damage, personal injury or loss of life
I. Lighting Instructions (SP)
•
For normal use, activate/deactivate your fi replace with the wall switch or remote control.
•
If your fi replace must be deactivated for serviced or an extended period of time, follow the instructions below.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
18
Initial Break-in Procedure
•
The fireplace should be run three to four hours
continuously on high.
•
Turn the fi replace off and allow it to completely cool.
•
Remove fi xed glass assembly. See Section 15.A.
•
Clean fi xed glass assembly. See Section 3.A.
•
Replace the fi xed glass assembly and run continuously
on high an additional 12 hours.
This cures the materials used to manufacture the fi re-
place.
NOTICE! Open windows for air circulation during fi replace
break-in.
• Some people may be sensitive to smoke and
odors.
• Smoke detectors may activate.
J. After Fireplace is Lit
K. Frequently Asked Questions
ISSUE
SOLUTIONS
Condensation on the glass
This is a result of gas combustion and temperature variations. As the appliance warms, this
condensation will disappear.
Blue fl ames
This is a result of normal operation and the fl ames will begin to yellow as the appliance is allowed
to burn for 20 to 40 minutes.
Odor from appliance
When fi rst operated, this appliance may release an odor for the fi rst several hours. This is caused
by the curing of materials from manufacturing. Odor may also be released from fi nishing materials
and adhesives used near the appliance. These circumstances may require additional curing
related to the installation environment.
Film on the glass
This is a normal result of the curing process of the paint and logs. Glass should be cleaned within
3 to 4 hours of initial burning. A non-abrasive cleaner such as gas appliance glass cleaner may be
necessary. See your dealer.
Metallic noise
Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the
sound produced by a furnace or heating duct. This noise does not affect the operation or longevity
of the appliance.
Is it normal to see the pilot
fl ame burn continually?
In an IntelliFire ignition system (IPI), the pilot fl ame should turn off when appliance is turned off.
Some optional control systems available with IPI models may allow pilot fl ame to remain lit. In a
standing pilot system the pilot will always stay on.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
19
Glass Cleaning
Frequency: Seasonally
By: Homeowner
Tools Needed: Protective gloves, glass cleaner, drop
cloth and a stable work surface.
CAUTION! Handle fi xed glass assembly with care.
Glass is breakable.
•
Avoid striking, scratching or slamming glass
•
Avoid abrasive cleaners
•
DO NOT clean glass while it is hot
•
Prepare a work area large enough to accommodate fi xed
glass assembly and door frame by placing a drop cloth
on a fl at, stable surface.
Note: Fixed glass assembly and gasketing may have
residue that can stain carpeting or fl oor surfaces.
•
Remove door or decorative front from fi replace and set
aside on work surface.
•
See Section 15.A for instructions to remove fi xed glass
assembly.
•
Clean glass with a non-abrasive commercially available
cleaner.
- Light deposits: Use a soft cloth with soap and water
- Heavy deposits: Use commercial fi replace glass cleaner
(consult with your dealer)
•
Carefully set fi xed glass assembly in place on fi replace.
Hold glass in place with one hand and secure glass
latches with the other hand.
•
Reinstall door or decorative front.
3
3 Maintenance and Service
A. Maintenance Tasks-Homeowner
The following tasks may be performed annually by the
homeowner. If you are uncomfortable performing any of
the listed tasks, please call your dealer for a service ap-
pointment.
More frequent cleaning may be required due to lint from
carpeting or other factors. Control compartment, burner
and circulating air passageway of the fi replace must be
kept clean.
CAUTION! Risk of Burns! The fi replace should be
turned off and cooled before servicing.
When properly maintained, your fi replace will give you
many years of trouble-free service. We recommend an-
nual service by a qualifi ed service technician.
Doors, Surrounds, Fronts
Frequency: Annually
By: Homeowner
Tools needed: Protective gloves, stable work surface
•
Assess condition of screen and replace as necessary.
•
Inspect for scratches, dents or other damage and repair
as necessary.
•
Check that louvers are not blocked.
•
Vacuum and dust surfaces.
Any safety screen or guard removed for servicing must be
replaced prior to operating the fi replace.
Installation and repair should be done by a qualifi ed
service technician only. The fi replace should be inspect-
ed before use and at least annually by a professional
service person.
Remote Control
Frequency: Seasonally
By: Homeowner
Tools needed: Replacement batteries and remote control
instructions.
•
Locate remote control transmitter and receiver.
•
Verify operation of remote. Refer to remote control
operation instructions for proper calibration and setup
procedure.
•
Place batteries as needed in remote transmitters and
battery-powered receivers.
•
Place remote control out of reach of children.
If not using your fi replace for an extended period of time
(summer months, vacations/trips, etc), to prevent unin-
tended operation:
•
Remove batteries from remote controls.
•
Unplug 3 volt adapter plug on IPI models.
Venting
Frequency: Seasonally
By: Homeowner
Tools needed: Protective gloves and safety glasses.
•
Inspect venting and termination cap for blockage or
obstruction such plants, bird nests, leaves, snow, debris,
etc.
•
Verify termination cap clearance to subsequent
construction (building additions, decks, fences, or
sheds). See Section 6.
•
Inspect for corrosion or separation.
•
Verify weather stripping, sealing and fl ashing remains
intact.
•
Inspect draft shield to verify it is not damaged or
missing.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
20
Control Compartment and Firebox Top
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves, vacuum cleaner, dust
cloths
•
Vacuum and wipe out dust, cobwebs, debris or pet hair.
Use caution when cleaning these areas. Screw tips that
have penetrated the sheet metal are sharp and should
be avoided.
•
Remove all foreign objects.
•
Verify unobstructed air circulation.
B. Maintenance Tasks-Qualifi ed Service
Technician
The following tasks must be performed by a qualifi ed
service technician.
Logs
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves.
•
Inspect for damaged or missing logs. Replace as
necessary. Refer to Section 15.F. for log placement
instructions.
•
Verify correct log placement and no fl ame impingement
causing sooting. Correct as necessary.
Firebox
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves, sandpaper, steel wool,
cloths, mineral spirits, primer and touch-up paint.
•
Inspect for paint condition, warped surfaces, corrosion
or perforation. Sand and repaint as necessary.
•
Replace fi replace if fi rebox has been perforated.
Gasket Seal and Glass Assembly Inspection
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves, drop cloth and a stable
work surface.
•
Inspect gasket seal and its condition.
•
Inspect fi xed glass assembly for scratches and nicks
that can lead to breakage when exposed to heat.
•
Confi rm there is no damage to glass or glass frame.
Replace as necessary.
•
Verify that fi xed glass assembly is properly retained and
attachment components are intact and not damaged.
Replace as necessary.
Burner Ignition and Operation
Frequency: Annually
By: Qualifi ed Service Technician
Tools needed: Protective gloves, vacuum cleaner, whisk
broom, fl ashlight, voltmeter, indexed drill bit set, and a
manometer.
•
Verify burner is properly secured and aligned with pilot
or igniter.
•
Clean off burner top, inspect for plugged ports, corrosion
or deterioration. Replace burner if necessary.
•
Replace rockwool with new dime-size pieces. DO NOT
block ports or obstruct lighting paths. Refer to Section
15.F. for proper rockwool placement.
•
Verify batteries have been removed from battery back-
up IPI systems to prevent premature battery failure or
leaking.
•
Check for smooth lighting and ignition carryover to all
ports. Verify that there is no ignition delay.
•
Inspect for lifting or other fl ame problems.
•
Verify air shutter setting is correct. See Section 14.D.
for required air shutter setting. Verify air shutter is clear
of dust and debris.
•
Inspect orifi ce for soot, dirt and corrosion. Verify orifi ce
size is correct. See Service Parts List for proper orifi ce
sizing.
•
Verify manifold and inlet pressures. Adjust regulator as
required.
•
Inspect pilot fl ame pattern and strength. See Figure 3.1
for proper pilot fl ame pattern. Clean or replace orifi ce
spud as necessary.
•
Inspect thermocouple/thermopile or IPI fl ame sensing
rod for soot, corrosion and deterioration. Clean with
emery cloth or replace as required.
•
Verify thermocouple/thermopile or IPI millivolt output.
Replace as necessary.
Figure 3.1 Standing Pilot Flame Patterns
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
21
Noncombustible roof
flashing maintains minimum
clearance around pipe
(SECTION 10)
Ceiling Firestop
on floor of attic
(SECTION 8)
Vent Pipe
(SECTIONS 7, 8, 10)
Framing/Header
(SECTION 5)
Gas Line
(SECTION 11)
Framing Headed off
in Ceiling Joists
(SECTION 8)
Mantel & Mantel Leg
(SECTION 13)
Surround
Hearth Extension
(not required)
Optional
Wall Switch
Vertical Termination Cap
(SECTION 10)
Storm Collar
(SECTION 10)
Attic insulation shield (not shown) must be used here to
keep insulation away from vent pipe if attic is insulated.
(SECTION 8)
Vent pipe penetrates roof,
preferably without affecting
roof rafters
(SECTION 8)
A. Typical Appliance System
NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not
drawn to scale. Actual product may vary from pictures in manual
Figure 4.1
Typical System
4
4 Getting Started
Installer Guide
Note: Dual venting confi gurations
ARE NOT allowed. Appliance
MUST be vented EITHER vertically
OR horizontally.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
22
B. Design and Installation Considerations
Quadra-Fire direct vent gas appliances are designed to
operate with all combustion air siphoned from outside of
the building and all exhaust gases expelled to the out-
side. No additional outside air source is required.
Installation MUST comply with local, regional, state and
national codes and regulations. Consult insurance carrier,
local building inspector, fi re offi cials or authorities having
jurisdiction over restrictions, installation inspection and
permits.
Before installing, determine the following:
• Where the appliance is to be installed.
• The vent system confi guration to be used.
• Gas supply piping.
• Electrical wiring requirements.
• Framing and fi nishing details.
• Whether optional accessories—devices such as a fan,
wall switch, or remote control—are desired.
D. Inspect Appliance and Components
•
Carefully remove the appliance and components from
the packaging (refer to Figure 4.2).
-
Remove refractory from back of unit by removing the
screws from shipping bracket.
-
Remove screws from shipping brackets before trying
to remove unit from pallet.
-
Remove and save screws from andirons for later
installation.
-
Remove screw from top of each carrying handle.
Handles have been provided to assist in moving the
unit.
•
The vent system components and decorative doors and
fronts are shipped in separate packages.
•
Report to your dealer any parts damaged in shipment,
particularly the condition of the glass.
•
Read all of the instructions before starting the installation.
Follow these instructions carefully during the installation
to ensure maximum safety and benefi t.
WARNING! Risk of Fire or Explosion! Damaged parts
could impair safe operation. DO NOT install damaged,
incomplete or substitute components. Keep appliance dry.
C. Tools and Supplies Needed
Before beginning the installation be sure that the following
tools and building supplies are available.
Tape measure
Framing material
Pliers
Non-corrosive leak check solution
Hammer
Phillips screwdriver
Gloves
Framing square
Voltmeter
Electric drill and bits (1/4 in.)
Plumb line
Safety glasses
Level
Reciprocating saw
Manometer
Flat blade screwdriver
1/2 - 3/4 in. length, #6 or #8 Self-drilling screws
Caulking material (300ºF minimum continuous exposure
rating)
One 1/4 in. female connection (for optional fan).
Hearth & Home Technologies disclaims any responsibility for,
and the warranty will be voided by, the following actions:
• Installation and use of any damaged appliance or vent system
component.
• Modifi cation of the appliance or vent system.
• Installation other than as instructed by Hearth & Home
Technologies.
• Improper positioning of the gas logs or the glass door.
• Installation and/or use of any component part not approved
by Hearth & Home Technologies.
Any such action may cause a fi re hazard.
WARNING! Risk of Fire, Explosion or Electric Shock!
DO NOT use this appliance if any part has been under wa-
ter. Call a qualifi ed service technician to inspect the appli-
ance and to replace any part of the control system and/or
gas control which has been under water.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. For
assistance or additional information, consult a qualifi ed
service technician, service agency or your dealer.
Refractory
Shipping Brackets
Andirons
Figure 4.2
Refractory Shipping Location, Brackets
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
23
5
5 Framing and Clearances
A. Select Appliance Location
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access. Due
to high temperatures, the appliance should be located out
of traffi c and away from furniture and draperies.
NOTICE: Illustrations refl ect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
52 in.
(1321 mm)
1.5 in. (114 mm)
1.5 in.
(114 mm)
31 in.
(787 mm)
69-3/4 in.
(1772 mm)
69-3/4 in.
(1772 mm)
1.5 in.
(114 mm)
1.5 in.
(114 mm)
1.5 in.
(114 mm)
Top Vent
One 90° elbow
Horiz Term
In addition to these framing dimensions, also
reference the following sections:
• Clearances and Mantel Projections
(Sections 3.C. and 3.D.)
• Vent Clearances and Framing
(Section 6)
52 in.
(1321 mm)
98-5/8 in.
(2505 mm)
12 in.
(305 mm)
Figure 5.1
Appliance Locations
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
24
Combustible flooring may be installed
next to the front of the appliance.
ALL SURFACES MUST BE FLUSH
WITH THE BOTTOM OF THE UNIT.
C
B
A
Drywall
1-1/2 in.
(38 mm)
0 in.
1-1/2 in.
(38 mm)
0 in.
D
40-7/8 in.
(1038 mm)
to ceiling
0 in. to level
of standoffs
36 in.
(914 mm)
Combustible Object
1-1/2 in.
(38 mm)
A
Rough Opening
(Width)
B
Rough Opening
(Height)
C
Rough Opening
(Depth)
D
Rough Opening
(DVP Pipe)
in.
52
66 5/8
31
10
mm
1321
1692
787
254
B. Construct the Appliance Chase
A chase is a vertical box-like structure built to enclose the
gas appliance and/or its vent system. In cooler climates
the vent should enclosed inside the chase.
NOTICE: Treatment of ceiling fi restops and wall shield
fi restops and construction of the chase may vary with the
type of building. These instructions are not substitutes for the
requirements of local building codes. Therefore, you MUST
check local building codes to determine the requirements
to these steps.
Chases should be constructed in the manner of all outside
walls of the home to prevent cold air drafting problems.
The chase should not break the outside building envelope
in any manner.
Walls, ceiling, base plate and cantilever fl oor of the chase
should be insulated. Vapor and air infi ltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air infi ltration may be an issue, the inside surfaces may be
sheetrocked and taped for maximum air tightness.
To further prevent drafts, the wall shield and ceiling fi re-
stops should be caulked with caulk with a minimum of 300ºF
Figure 5.2
Clearances to Combustibles
C. Clearances
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly on
carpeting, vinyl, tile or any combustible material other than
wood.
WARNING! Risk of Fire! Maintain specifi ed air space
clearances to appliance and vent pipe:
•
Insulation and other materials must be secured to
prevent accidental contact.
•
The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with fi replace or chimney.
•
Failure to maintain airspace may cause overheating and
a fi re.
continuous exposure rating to seal gaps. Gas line holes
and other openings should be caulked with caulk with a
minimum of 300ºF continuous exposure rating or stuffed with
unfaced insulation. If the appliance is being installed on
a cement slab, a layer of plywood may be placed under-
neath to prevent conducting cold up into the room.
Note: If the inside of the framed cavity is to be fi nished,
the framing dimensions must include the fi nished surface.
If drywall is to be attached to the rear wall, the depth must
be measured from the drywall surface.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
25
Mantel
Non-combustible
Face
A
A = 53 in. (1346 mm) min.
Non-combustible Mantel
12 in. (308 mm)
maximum depth
A = 66 in. (1676 mm) min.
Combustible Mantel
D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of non-combustible materials (i.e., steel studs,
concrete board, etc).
Figure 5.3
Minimum Vertical and Maximum Horizontal Dimensions
11 in. (279 mm) Min.
to perpendicular wall
A
12 in. (305 mm) Min.
from fireplace opening
to perpendicular wall
B
Mantel Leg or
Perpendicular Wall
Top of
Appliance
Drywall
A
B
Figure 5.4
Mantel Leg or Wall Projections (Acceptable on both sides of opening)
Mantels
Mantel Legs or Wall Projections
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
26
A. Vent Termination Minimum Clearances
Figure 6.1
Minimum Height From Roof To Lowest Discharge
Opening
Horizontal
overhang
12
X
20 in.
(508 mm)
Lowest
Discharge
Opening
Termination
Cap
Roof Pitch
is X / 12
Vertical
wall
H (min.) - Minimum height
from roof to lowest
discharge opening.
24 in. min.
(610 mm)
Roof Pitch
H (Min.) Ft.
Roof Pitch
H (Min.) Ft.
Flat to 6/12
1.0*
Over 11/12 to 12/12
4.0
Over 6/12 to 7/12
1.25*
Over 12/12 to 14/12
5.0
Over 7/12 to 8/12
1.5*
Over 14/12 to 16/12
6.0
Over 8/12 to 9/12
2.0*
Over 16/12 to 18/12
7.0
Over 9/12 to 10/12
2.5
Over 18/12 to 20/12
7.5
Over 10/12 to 11/12
3.25
Over 20/12 to 21/12
8.0
* 3 ft. minimum in snow regions
Storm Collar
Roof
Flashing
6
6 Termination Locations
Fire Risk.
Maintain vent clearance to combustibles as
specifi ed.
• DO NOT pack air space with insulation or other
materials.
Failure to keep insulation or other materials away
from vent pipe may cause overheating and fi re.
WARNING
Gas, Wood or Fuel Oil
Termination Cap
B
Gas
Termination
Cap **
A *
*
If using decorative cap cover(s), this distance may need to be
increased. Refer to the installation instructions supplied with the
decorative cap cover.
**
A
B
6 in. (minimum) up to 20 in.
152 mm/508 mm
18 in. minimum
457 mm
20 in. and over
0 in. minimum
In a staggered installation with both gas and wood or fuel oil
terminations, the wood or fuel oil termination cap must be
higher than the gas termination cap.
Figure 6.2
Multiple Termination Caps
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
27
Dimension Descriptions
A Clearance above the ground, a veranda, porch, deck or balcony - 12 in.
(30 cm) minimum. *
B Clearance to window or door that may be opened – 10,000 BTUs or less,
6 in. (15 cm) minimum; 10,000-50,000 BTUs, 9 in. (23 cm) minimum; over
50,000 BTUs, 12 in. (30 cm) minimum. *
C Clearance to permanently closed window – 12 in. (30 cm) minimum -
recommended to prevent condensation on window.
D Vertical clearance to ventilated soffi t located above the termination within
a horizontal distance of 2 ft (60 cm) from the centerline of the termination
– 18 in. (46 cm) minimum. **
E Vertical clearance to unventilated soffi t - 12 in. (30 cm) minimum. **
F Clearance to outside corner - 6 in. (15 cm) minimum.
G Clearance to inside corner - 6 in. (15 cm) minimum.
H Not to be installed above a meter/regulator assembly within 3 ft (90 cm)
horizontally* from the center line of the regulator (Canada only)
I Clearance to service regulator vent outlet – 3 ft (.91 m) U.S. minimum and
3 ft (.91 m) Canada minimum. *
J Clearance to non-mechanical air supply inlet into building or the combustion
air inlet to any other appliance – 9” (23 cm) U.S. minimum and 12 in. (30
cm) Canada minimum. *
K Clearance to mechanical air supply inlet - 3 ft (.91 m) U.S. minimum and
6 ft (1.8 m) Canada minimum. *
L Clearance above a paved sidewalk or paved driveway located on public
property - 7 ft (2.1 m) minimum.
A vent may not terminate directly above a sidewalk or paved driveway
which is located between two single family dwellings and serves both
dwellings.
M Clearance under veranda, porch, deck or balcony - 12 in. (30 cm) minimum.
* Recommended 30 in. (76 cm) for vinyl or plastic.
Only permitted if veranda, porch, deck or balcony is fully open on a
minimum of 2 sides beneath the fl oor. *
N Vertical clearance between two horizontal termination caps – 12 in. (30
cm) minimum.
O Horizontal clearance between two horizontal termination caps – 12 in. (30
cm) minimum.
P 6” - Non-vinyl sidewalls
12” – Vinyl sidewalls
Q 18” – Non-vinyl soffi t and overhang
42” – Vinyl soffi t and overhang
R 8 ft.
D
E
B
L
C
V
V
B
F
V
B
V
V
B
X
A
J
Fixed
Closed
M
V
K
X
RESTRICTION ZONE
(TERMINATION NOT
ALLOWED)
AIR SUPPLY INLET
X
GAS METER
V TERMINATION CAP
H
B
Openable Fixed
Closed
V
I
V
O
N
Q
P
R
T
S
Electrical
Service
V
U
V
U
V
W
D*
V
V
Covered Alcove
Applications
Clearances to Electrical Service
A
V
V
G
Measure horizontal clearances
from this surface.
Measure vertical clearances
from this surface
S min
T max
1 cap
3 ft
2 x S actual
2 caps
6 ft
1 x S actual
3 caps
9 ft
2/3 x S actual
4 caps
12 ft
1/2 x S actual
S min = # term caps x 3
T max = (2/# term caps) x S (actual)
U 6” min. – Clearance from sides of electrical service.
W 12” min. – Clearance above electrical service.
* As specifi ed in CGA B149 Installation Codes
Note: Local codes or regulations may require different clearances.
** Clearance required to vinyl soffi t material – 30 in. (76 cm) minimum.
Note: Location of the vent termination must not interfere with access to
the electrical service.
Figure 6.3
Minimum Clearances for Termination
CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.
WARNING!
In the U.S.: Vent system termination is NOT permitted in screened
porches. You must follow side wall, overhang and ground clearances
as stated in the instructions.
In Canada: Vent system termination is NOT permitted in screened
porches. Vent system termination is permitted in porch areas with
two or more sides open. You must follow all side wall, overhang and
ground clearances as stated in the instructions.
Hearth & Home Technologies assumes no responsibility for the
improper performance of the appliance when the venting system does
not meet these requirements.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
28
Horizontal
Vertical
8-1/2 in.
8-1/2 in.
12 in.
On 45° runs, 1 ft (.3 m) of diagonal is equal to 8-1/2 in. (216
mm) horizontal run and 8-1/2 in. (216 mm) vertical run.
A. Approved Pipe
This appliance is approved for use with Hearth & Home
Technologies DVP venting systems. Refer to Section
17.B. for vent component information.
DO NOT mix pipe, fi ttings or joining methods from differ-
ent manufacturers.
The pipe is tested to be run inside an enclosed wall.
There is no requirement for inspection openings at each
joint within the wall.
WARNING! Risk of Fire or Asphyxiation. This appliance
requires a separate vent. DO NOT vent to a pipe serving a
separate solid fuel burning appliance.
C. Use of Elbows
Diagonal runs have both vertical and horizontal vent aspects
when calculating the effects. Use the rise for the vertical
aspect and the run for the horizontal aspect (see Figure
7.1).
Two 45º elbows may be used in place of one 90º elbow.
On 45º runs, one foot of diagonal is equal to 8-1/2 in. (216
mm) horizontal run and 8-1/2 in. (216 mm) vertical run. A
length of straight pipe is allowed between two 45º elbows
(see Figure 7.1).
Figure 7.1
Using Two 45° Elbows
7
7 Vent Information and Diagrams
B. Vent Table Key
The abbreviations listed in this vent table key are used in
the vent diagrams.
D. Measuring Standards
Vertical and horizontal measurements listed in the vent
diagrams were made using the following standards.
•
Pipe measurements are shown using the effective length
of pipe (see Figure 7.2).
•
Horizontal terminations are measured to the outside
mounting surface (fl ange of termination cap) (see
Figure 6.4).
•
Vertical terminations are measured to bottom of
termination cap.
•
Horizontal pipe installed level with no rise.
Figure 7.2
Pipe Effective Length
Symbol
Description
V1
First section (closest to appliance) of vertical length
V2
Second section of vertical length
H1
First section (closest to appliance) of horizontal length
H2
Subsequent sections of horizontal length
Effective
Height/Length
DVP Pipe
(see chart)
Pipe
inches
mm
DVP4
4
102
DVP6
6
152
DVP12
12
305
DVP24
24
610
DVP36
36
914
DVP48
48
1219
DVP6A
3 - 6
76 - 152
DVP12A
3 - 12
76 - 305
Effective Height/Length
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
29
H1
V1
To replace the fi rst starter elbow with two 45° elbows,
refer to Figure 7.4. All other 90° elbows can be replaced
with two 45° elbows.
General Rules:
•
SUBTRACT 3 ft. from the total H measurement for each
90° elbow installed horizontally.
•
SUBTRACT 1-1/2 ft. from the total H measurement for
each 45° elbow installed horizontally.
•
A maximum of three 90° elbows (or six 45° elbows)
may be used in any vent confi guration. Some elbows
may be installed horizontally. See Figure 7.9.
•
Elbows may be placed back to back anywhere in the
system as long as the fi rst 90° elbow is a starter elbow
except as shown in Figure 7.4.
•
When penetrating a combustible wall, a wall shield
fi restop must be installed.
•
When penetrating a combustible ceiling, a ceiling
fi restop must be installed.
•
Horizontal runs of vent do not require vertical rise;
horizontal runs may be level.
E. Vent Diagrams
Figure 7.3
One Elbow
1. Top Vent - Horizontal Termination
V1 Min.
V1 Max.
H1 Max.
3 ft (.91 m)
-
1.5 ft (.46 m)
4 ft (1.22 m)
-
6 ft (1.83 m)
5 ft (1.52)
-
11 ft (3.35 m)
6 ft (1.83 m)
-
13 ft (3.96 m)
7 ft (2.13 m)
-
15 ft (4.57 m)
10 ft (3.05 m)
25 ft (7.62 m)
20 ft (6.10 m)
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
30
4 ft min.
(1.22 m)
17 ft max.
(5.18 m)
3 ft min.
(.91 m)
1. Top Vent - Horizontal Termination - (continued)
Figure 7.4
Two 45° Elbows replacing One 90° Elbow
Figure 7.5
Three Elbows
H1
V1
V2
H2
Installed
Vertically
V1
H1
V2
H2
3 ft (.91 m)
3 ft (.91 m)
4 ft (1.22 m)
4 ft (1.22 m)
6 ft (1.83 m)
8 ft (2.45 m)
8 ft (2.45 m)
12 ft (3.66 m)
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
31
2. Top Vent - Vertical Termination
No Elbow
Figure 7.7
Figure 7.8
Two Elbows
Note: If installing a vertical vent/ter-
mination off the top of the appliance,
the fl ue restrictor should be used.
See Section 15.E. for necessary
damper adjustment.
12 ft (3.66 m) min.
60 ft (18.29 m) max.
12 ft (3.66 m) min.
60 ft (18.29 m) max.
Maximum horizontal
run is 100% of
vertical, but cannot
exceed 18 ft (5.49 m)
3 ft m (.91
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
32
Figure 7.9
2. Top Vent - Vertical Termination - (continued)
Three Elbows
12 ft (3.66 m) min.
60 ft (18.29 m) max.
Maximum horizontal run is
100% of vertical, but cannot
exceed 26 ft (7.92 m)
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
33
No combustible
framing to be
located within
shaded area.
1-1/2 in. (13 mm)
minimum to
perpendicular
wall.
WALL
2 x 4 or
2 x 6
header
Drywall
3 in.
(76 mm)
1 in. (25 mm)
minimum
Air space clearance to
bottom and sides of
horizontal pipe must be
at least 1 in. (25 mm)
Framing should be
constructed of 2 X 4
lumber or heavier.
The center of the
framing hole is
1 in. [25 mm] above
the center of the
horizontal vent pipe.
Vent
framing
hole.
102-1/2 in.
(2604 mm)*
* Center of pipe
10 in.
(254 mm)
12 in.
(305 mm)
A. Pipe Clearances to Combustibles
WARNING! Risk of Fire! Maintain air space clearance to
vent. DO NOT pack insulation or other combustibles:
•
Between ceiling fi restops
•
Between wall shield fi restops
•
Around vent system
Failure to keep insulation or other material away from
vent pipe may cause over heating and fi re.
8
8 Vent Clearances and Framing
B. Wall Penetration Framing
Combustible Wall Penetration
Whenever a combustible wall is penetrated, you must
frame a hole for the wall shield fi restop(s). The wall shield
fi restop maintains minimum clearances and prevents cold
air infi ltration.
•
The opening must be framed on all four sides using the
same size framing materials as those used in the wall
construction.
•
A wall shield fi restop is required on one side only on
interior walls. If your local inspector requires a wall shield
fi restop on both sides, then both wall shield fi restops
must have a heat shield attached to them.
•
See Section 10.I. for information for regarding the
installation of a horizontal termination cap.
Figure 8.2 Wall Penetration
Figure 8.1 Horizontal Venting Clearances To Combustible Materi-
als
Non-Combustible Wall Penetration
If the hole being penetrated is surrounded by non-combus-
tible materials such as concrete, a hole with diameter one
inch greater than the pipe is acceptable.
Whenever a non-combustible wall is penetrated, the wall
shield fi restop is only required on one side and no heat
shield is necessary.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
34
C. Install the Ceiling Firestop
A ceiling fi restop MUST be used between fl oors and at-
tics.
•
Frame an opening 10 in. by 10 in. (254 mm by 254
mm) whenever the vent penetrates a ceiling/fl oor (see
Figure 8.3).
•
Frame the area with the same sized lumber as used in
ceiling/fl oor joist.
•
The ceiling fi restop may be installed above or below
the ceiling joists when installed with a attic insulation
shield. It must be under joists between fl oors that are
not insulated. Refer to Figure 8.4.
•
Secure with three fasteners on each side.
WARNING! Risk of Fire! DO NOT pack insulation around
the vent. Insulation must be kept back from the pipe to pre-
vent overheating.
Figure 8.3
Installing Ceiling Firestop
Figure 8.4 Installing the Attic Shield
Attic Above
10 in. (254 mm)
Hole should measure
10 in. x 10 in.
(254 mm x 254 mm)
inside to inside
10 in.
(254 mm)
3 fasteners
per side
Ceiling firestop
installed below ceiling.
Ceiling firestop
installed above ceiling.
Install attic insula-
tion shields before
or after installation
of vent system.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
35
Bend all tabs inward
90° to maintain
clearance and
prevent insulation
from falling inside
Insert 3
screws
Bend 4 tabs
inward 90°
to maintain
clearance
D. Install Attic Insulation Shield
WARNING! Fire Risk. DO NOT allow loose materials or
insulation to touch vent. Hearth & Home Technologies Inc.
requires the use of an attic shield.
The National Fuel Gas Code ANSI Z223.1 and NFPA 54
requires an attic shield constructed of 26 gauge minimum
metal that extends at least 2 in. (51 mm) above insulation.
Attic shields must meet specifi ed clearance and be se-
cured in place.
Flat Ceiling Installation
•
Remove one shield from box.
NOTICE: Cut previously installed batt insulation to make
room for the attic insulation shield.
•
Wrap shield around pipe if pipe is already installed in
area to be insulated.
•
Match the three holes in each side and fasten with three
screws to form a tube.
•
Bend three tabs on the bottom of the shield outward to
allow attachment to the ceiling fi restop.
•
Bend the remaining bottom tabs inward 90° to maintain
the air space between the pipe and the shield. Set the
shield on the ceiling fi restop and attach to the fi restop.
•
Bend all tabs inward 90° around the top of the shield.
These tabs must be used to prevent blown insulation
from getting between the shield and vent pipe, and to
maintain air space clearance.
Figure 8.5 Attic Insulation Shield
Vaulted Ceiling Installation
•
Remove one shield from box.
NOTICE: Cut previously installed batt insulation to make
room for the attic insulation shield.
•
Cut the attic insulation shield (if application is for vaulted
ceiling), to fi t your ceiling pitch. Snip cut edge to recreate
1 in. bend tabs all the way around the bottom.
•
Wrap shield around pipe if pipe is already installed in
area to be insulated.
•
Match the three holes in each side and fasten with three
screws to form a tube.
•
Bend three tabs on the bottom of the shield outward to
allow attachment to the ceiling fi restop.
•
Bend the remaining bottom tabs inward 90° to maintain
the air space between the pipe and the shield. Set
the shield on the ceiling fi restop and attach to the
fi restop.
•
Bend all tabs inward 90° around the top of the shield.
These tabs must be used to prevent blown insulation
from getting between the shield and vent pipe, and to
maintain air space clearance.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
36
A. Secure and Level the Appliance
WARNING! Risk of Fire! Prevent contact with:
•
Sagging or loose insulation
•
Insulation backing or plastic
•
Framing and other combustible materials
Block openings into the chase to prevent entry of
blown-in insulation. Make sure insulation and other
materials are secured.
DO NOT notch the framing around the appliance
standoffs.
Failure to maintain air space clearance may cause
overheating and fi re.
The diagram shows how to properly position and secure
the appliance (see Figure 9.1). Nailing tabs are provided to
secure the appliance to the framing members.
•
Bend out nailing tabs on each side.
•
Place the appliance into position.
•
Keep nailing tabs fl ush with the framing.
•
Level the appliance from side to side and front to
back.
•
Shim the appliance as necessary. It is acceptable to use
wood shims underneath the appliance.
•
Secure the appliance to the framing by using nails or
screws through the nailing tabs.
•
Secure the appliance to the fl oor by inserting two screws
through the pilot holes at the bottom of the appliance.
Figure 9.1
Proper Positioning and Securing of an Appliance
9
9 Appliance Preparation
NOTICE: The bottom of the door frame at time of
installation will be fl ush with the bottom of the unit. Keep
fl oor or hearth covering fl ush with the bottom of the unit
or the door will not fi t on the unit.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
37
Lances
10
10 Install Vent Pipe
A. Assemble Vent Sections
Attach Pipe to the Firebox Assembly
Note: The end of the pipe sections with the lanced tabs will
face towards the appliance.
Attach the fi rst pipe section to the starting collar:
•
Lanced pipe end to the starting collar
•
Inner pipe over inner collar
•
Push the pipe section until all lanced tabs snap in
place
•
Lightly tug on pipe to confi rm it has locked.
Figure 10.1 High Temperature Silicone Sealant
Figure 10.2
Figure 10.3
Assemble Pipe Sections
Per Figure 10.2:
•
Start the inner pipe on the lanced end of section A into
the fl ared end of section B.
•
Start the outer pipe of section A over the outer pipe of
section B.
•
Once both vents sections are started, push fi rmly until
all lanced tabs lock into place.
•
Lightly tug on the pipe to confirm the tabs have
locked.
It is acceptable to use screws no longer than 1/2 in. (13
mm) to hold outer pipe sections together. If predrilling
holes, DO NOT penetrate inner pipe.
For 90° and 45° elbows that are changing the vent
direction from horizontal to vertical, one screw minimum
should be put in the outer fl ue at the horizontal elbow joint
to prevent the elbow from rotating. Use screws no longer
than 1/2 in. (13 mm). If predrilling screw holes, DO NOT
penetrate inner pipe.
Commercial, Multi-family (Multi-level exceeding
two stories), or High-Rise Applications
All outer pipe joints must be sealed with high temperature
silicone (300º F minimum continuous exposure rating),
including the slip section that connects directly to the
horizontal termination cap.
• Apply a bead of silicone sealant inside the female outer
pipe joint prior to joining sections. See Figure 10.1
• Only outer pipes need to be sealed. All unit collar, pipe,
slip section, elbow and cap outer fl ues shall be sealed in
this manner, unless otherwise stated.
WARNING! Risk of Fire or Explosion! DO NOT break
silicone seals on slip sections. Use care when removing
termination cap from slip pipe. If slip section seals are bro-
ken during removal of the termination cap, vent may leak.
Figure 10.4 Seams
Note: Make sure that the seams are not aligned to prevent
unintentional disconnection.
A
B
INCORRECT
CORRECT
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
38
B. Assemble Slip Sections
WARNING! Risk of Fire or Asphyxiation! Overlap pipe
sections at least 1 1/2 in. (38 mm). Secure slip sections
with two screws which must not exceed 1/2 in. (13 mm)
in length. Use the pilot holes. Pipe could separate if not
properly joined.
•
Slide the inner fl ue of the slip section into the inner fl ue of
the pipe section and the outer fl ue of the slip section over
the outer fl ue of the pipe section. See Figure 10.5.
•
Slide together to the desired length.
Figure 10.5 Slip Section Pilot Holes
Figure 10.6 Screws into Slip Section
NOTICE: When installing a vent system with an HRC
termination cap, all pipe system joints shall be sealed
using a high temperature silicone sealant (300º F minimum
continuous exposure rating).
• Apply a bead of silicone sealant inside the female outer
pipe joint prior to joining sections.
• Only outer pipes are sealed, sealing the inner fl ue is not
required.
• All unit collar, pipe, slip section, elbow and cap outer fl ues
shall be sealed.
•
Continue adding pipe as necessary following instructions
in “Assemble Pipe Sections.”
NOTICE: If slip section is too long, the inner and outer fl ues
of the slip section can be cut to the desired length.
•
Maintain a 1-1/2 in. (38 mm) overlap between the slip
section and the pipe section.
•
Secure the pipe and slip section with two screws no
longer than 1/2 in. (13 mm), using the pilot holes in the
slip section. See Figure 10.6.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
39
Figure 10.7 Securing Vertical Pipe Sections
Figure 10.8 Securing Horizontal Pipe Sections
D. Disassemble Vent Sections
•
Rotate either section (see Figure 10.9) so the seams
on both pipe sections are aligned as shown in Figure
10.10.
•
Pull carefully to separate the pieces of pipe.
C. Secure the Vent Sections
•
Vertical runs of pipe must be supported every 8 ft. (2.44
m) after the 25 ft. (7.62 m) maximum unsupported
rise.
•
Horizontal sections of vent must be supported every 5
ft. (1.52 m) with a vent support or plumber’s strap.
•
Wall shield fi restops may be used to provide horizontal
support.
•
Vent support or plumber’s strap (spaced 120° apart)
may be used for support. See Figures 10.7 and 10.8.
WARNING! Risk of Fire, Explosion or Asphyxi-
ation! Improper support may allow vent to sag and
separate. Use vent run supports and connect vent
sections per installation instructions. DO NOT allow
vent to sag below connection point to appliance.
Figure 10.10 Align and Disassemble Vent Sections
Figure 10.9 Rotate Seams for Disassembly
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
40
E. Install Metal Roof Flashing
•
See minimum vent heights for various pitched roofs
(Figure 10.11) to determine the length of pipe to extend
through the roof.
•
Slide the roof fl ashing over the pipe sections extending
through the roof as shown in Figure 10.12.
Horizontal
overhang
12
X
20 in.
(508 mm)
Lowest
Discharge
Opening
Termination
Cap
Roof Pitch
is X / 12
Vertical
wall
H (min.) - Minimum height
from roof to lowest
discharge opening.
24 in. min.
(610 mm)
Roof Pitch
H (Min.) Ft.
Roof Pitch
H (Min.) Ft.
Flat to 6/12
1.0*
Over 11/12 to 12/12
4.0
Over 6/12 to 7/12
1.25*
Over 12/12 to 14/12
5.0
Over 7/12 to 8/12
1.5*
Over 14/12 to 16/12
6.0
Over 8/12 to 9/12
2.0*
Over 16/12 to 18/12
7.0
Over 9/12 to 10/12
2.5
Over 18/12 to 20/12
7.5
Over 10/12 to 11/12
3.25
Over 20/12 to 21/12
8.0
* 3 ft. minimum in snow regions
Storm Collar
Roof
Flashing
Figure 10.11 Minimum Height From Roof To Lowest Discharge
Opening
Figure 10.12 Caulking
CAULK
NOTICE: Failure to properly caulk the roof fl ashing and
pipe seams may permit entry of water.
• Caulk the gap between the roof fl ashing and the outside
diameter of the pipe.
• Caulk the perimeter of the fl ashing where it contacts the
roof surface. See Figure 10.15.
• Caulk the overlap seam of any exposed pipe sections
that are located above the roof line.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
41
F. Assemble and Install Storm Collar
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during installa-
tion. Sheet metal edges are sharp.
•
Connect both halves of the storm collar with two screws
(see Figure 10.13).
•
Wrap the storm collar around the exposed pipe section
closest to the roof and align brackets. Insert a bolt
(provided) through the brackets and tighten the nut to
complete the storm collar assembly (Figure 10.14). Make
sure the collar is tight against the pipe section.
•
Slide the assembled storm collar down the pipe section
until it rests on the roof fl ashing.
•
Caulk around the top of the storm collar (see Figure
10.20).
Figure 10.13 Assembling the Storm Collar
Figure 10.14 Assembling the Storm Collar Around the Pipe
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
42
Important Notice: Heat shields may not be fi eld constructed.
H. Heat Shield Requirements for Horizontal
Termination
WARNING! Risk of Fire! To prevent overheating and fi re,
heat shields must extend through the entire wall thick-
ness.
• DO NOT remove the heat shields attached to the
wall shield fi restop and the horizontal termination
cap.
• Heat shields must overlap 1-1/2 in. (38 mm) mini-
mum.
There are two sections of the heat shield. One section
is factory-attached to the wall shield fi restop. The other
section is factory-attached to the cap. See Figure 10.16.
If the wall thickness does not allow the required 1-1/2 in.
(38 mm) heat shield overlap when installed, an extended
heat shield must be used.
•
If the wall thickness is less than 4 in./102 mm the heat
shields on the cap and wall shield fi restop must to be
trimmed. A minimum 1-1/2 in. (38 mm) overlap MUST
be maintained.
•
Use an extended heat shield if the fi nished wall thickness
is greater than 7-1/4 in. (184 mm).
•
The extended heat shield may need to be cut to length
maintaining suffi cient length for a 1-1/2 in. (38 mm)
overlap between heat shields.
•
Attach the extended heat shield to either of the existing
heat shields using the screws supplied with the extended
heat shield. Refer to “Vent Components Diagrams” in
the back of this manual.
•
Rest the small leg on the extended heat shield on top
of the pipe section to properly space it from the pipe
section.
G. Install Vertical Termination Cap
•
Attach the vertical termination cap by sliding the inner
collar of the cap into the inner fl ue of the pipe section
while placing the outer collar of the cap over the outer
fl ue of the pipe section.
•
Secure the cap by driving three self-tapping screws
(supplied) through the pilot holes in the outer collar of the
cap into the outer fl ue of the pipe (see Figure 10.15).
Figure 10.15 Install Vertical Termination Cap
Storm
Collar
Termination Cap
(1 of three)
Caulk
Screws
Brackets/
Bolts
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
43
INTERIOR
Heat Shield or
Extended
Heat Shield
Wall Shield
Firestop
Heat Shield
1-1/2 in. (38 mm) min.
overlap
SHEATHING
Slip Section
can be extended
Inner Vent
Outer Vent
EXTERIOR
Figure 10.16 Venting through the wall
Note: When using termination caps with factory-supplied
heat shield attached, no additional wall shield fi restop is
required on the exterior side of a combustible wall.
I. Install Horizontal Termination Cap
WARNING! Risk of Fire! The telescoping fl ue section
of the termination cap MUST be used when connecting
vent.
• 1-1/2 (38 mm) minimum overlap of fl ue telescoping
section is required.
Failure to maintain overlap may cause overheating and
fi re.
•
Vent termination must not be recessed in the wall. Siding
may be brought to the edge of the cap base.
•
Flash and seal as appropriate for siding material at
outside edges of cap.
•
When installing a horizontal termination cap, follow
the cap location guidelines as prescribed by current
ANSI Z223.1 and CAN/CGA-B149 installation codes
and refer to Section 6 of this manual.
CAUTION! Risk of Burns! Local codes may require
installation of a cap shield to prevent anything or anyone
from touching the hot cap.
NOTICE: For certain exposures which require superior
resistance to wind-driven rain penetration, a fl ashing kit and
HPC caps are available. When penetrating a brick wall, a
brick extension kit is available for framing the brick.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
44
11
11 Shrouds
•
Chase top shrouds may be fi eld constructed where permitted by regional building codes.
WARNING! Risk of Fire! Shrouds must be constructed
as specifi ed. Improper construction may overheat chase
top.
NOTICE: Some regional codes require an agency-Listed
shroud. Consult your local building offi cials.
•
The following fi eld constructed shroud designs have been tested for Hearth Technologies fi replace systems and termination
caps.
•
The shrouds must be constructed from a minimum .018 in. (26 ga) thick aluminized steel.
•
The wire mesh is optional but recommended and must be .018 in. thick minimum, 1/2 in. mesh.
A. HHT Shrouds
•
You may install a shroud with this fi replace. See Section 17.D. for a list of UL Listed shrouds. Follow the instructions
included with these optional components
Min.
Base Dim.
Min.
Base Dim.
Min.
Top Dim.
Min.
Top Dim.
Figure 11.1 Open Top Shroud Dimensions
B. Field Constructed Shrouds
Open Top Shroud (may be used with DVP-TV, DVP-TVHW, SLP-TVHW)
Min. Base Dims.
in
19 x 19
mm
483 x 483
Min. Top Dims.
in
16 x 16
mm
406 x 406
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
45
Min. Base Dim
Min. Height
Min.
Base Dim
Figure 11.2 Mailbox Style Shroud Dimensions
Minimum
Opening
Height
Minimum
Base Dimension
Min. Opening
Width
Min. Base Dimension
Minimum
Height
Figure 11.2 Roofed Style Shroud Dimensions
Roofed Style Shroud (may be used with DVP-TV, DVP-TVHW, SLP-TVHW)
Mailbox Style Shroud (may be used with DVP-TV, DVP-TVHW, SLP-TVHW)
Min. Base Dims.
in
20 x 20
mm
508 x 508
Min. Height
in
18
mm
457
Min. Base Dims.
in
20 x 20
mm
508 x 508
Min. Height
in
18
mm
458
Min. Opening Width
in
14
mm
356
Min. Opening Height
in
10
mm
254
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
46
A. Fuel Conversion
•
Make sure the appliance is compatible with available
gas types.
•
Conversions must be made by a qualified service
technician using Hearth & Home Technologies specifi ed
and approved parts.
12
12 Gas Information
•
Turn control knob on the valve to OFF position.
•
Remove glass assembly (see Figure 15.A)
•
(Remove logs, grate, and ember bed if already
installed.)
•
Remove 2 screws holding pilot bracket to burner. See
Figure 11.1.
Kit contents:
Pilot injector #35
Burner orifi ce
Red pin
Conversion Label
Tools Required:
#2 phillips screwdriver
Straight screwdriver
5/32 allen wrench
3/8 & 11/16 wrenches
Figure 12.1 Remove Pilot Screws
•
Remove 4 screws holding Burner in place and remove
burner. See Figure 12.2.
Figure 12.2 Remove Burner Screws
•
Using a 3/8 wrench, unscrew and remove rear orifi ce
and discard. See Figure 12.3.
Figure 12.3 Remove Burner Orifi ce
•
Unscrew and remove front orifi ce #46 and install in
rear.
•
Install new orifi ce #56 in front.
•
Open air shutters to fully open. See Figure 12.4.
•
Replace burner and screws holding it in place.
Figure 12.4 Adjusting Air Shutter
Note: Gas conversions should only be performed by a
qualifi ed service person, and/or where required by state
and local codes, licensed installer/service technician. In
the Commonwealth of Massachusetts, installation must
be performed by a licensed plumber or gas fi tter.
Converting to LP Gas
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
47
Control Knob
Screw (pressure adjustment)
Pin (blue-NG, red-LP)
Solenoid
Lock Nut
Figure 12.7 Valve Components
•
Replace 2 screws holding pilot bracket to burner.
•
Pull hood keeper from pilot and lift hood off pilot
assembly. See Figure 12.5.
Figure 12.5 Remove Pilot Hood
•
Remove #62 pilot injector using 5/32 allen wrench and
replace with #35 LP orifi ce.
Figure 12.6 Remove Pilot Injector
•
Replace hood and keeper.
•
Loosen locknut on the Hi-Lo Solenoid using 11/16
wrench.
•
Remove solenoid from the valve by turning
counterclockwise.
•
Use a screwdriver and turn pressure screw clockwise
¾ turn.
•
Attach manometer to outlet side of the valve.
•
Light unit.
•
Fine tune pressure with screwdriver.
•
Replace the blue pin with the red pin and screw solenoid
onto the valve.
•
Continue turning solenoid until pressure is 10.
•
Tighten locknut on the Solenoid so it will not loosen.
•
Install identification label near the valve. See
Figure 12.8.
44CKP
44CKN
THIS PLATE MUST BE AFFIXED AS CLOSE AS POSSIBLE TO THE EXISTING RATING
PLATE.
THE FOLLOWING MUST BE COMPLETED BY THE INDIVIDUAL CONVERTING THIS
APPLIANCE:
THIS APPLIANCE HAS BEEN CONVERTED TO __________FUEL,
FRONT ORIFICE __________, REAR ORIFICE ___________,
MANIFOLD PRESSURE _________, AND INPUT ___________, ON ____________ (date),
WITH KIT # 44CKP, 44CKN (circle one), BY (name & address of organization making this
conversion)
WHO ACCEPTS THE RESPONSIBILITY FOR THE CORRECTNESS OF THIS CONVERSION.
4051-304A
Figure 12.8 Identifi cation Label
Note: Do not remove retaining clip from the hood.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
48
C. Gas Connection
•
Refer to Reference Section 17.A. for location of gas line
access in appliance.
•
Gas line may be run through knockout provided on the
left side only.
•
The gap between supply piping and gas access hole
may be caulked with caulk with a minimum of 300º
F continuous exposure rating or stuffed with non-
combustible, unfaced insulation to prevent cold air
infi ltration.
•
Ensure that gas line does not come in contact with outer
wrap of the appliance. Follow local codes.
•
Pipe incoming gas line into valve compartment.
•
Connect incoming gas line to the 1/2 in. (13 mm)
connection on manual shutoff valve.
WARNING! Risk of Fire or Explosion! Support control
when attaching pipe to prevent bending gas line.
•
A small amount of air will be in the gas supply lines.
WARNING! Risk of Fire or Explosion! Gas build-up dur-
ing line purge could ignite.
•
Purge should be performed by qualified service
technician.
•
Ensure adequate ventilation.
•
Ensure there are no ignition sources such as sparks or
WARNING! Risk of Fire or Explosion! High pressure
will damage valve. Low pressure may cause explosion.
•
Verify inlet pressures. Verify minimum pressures when
other household gas appliances are operating.
•
Install regulator upstream of valve if line pressure is
greater than 1/2 psig.
Gas Pressure
Natural Gas
Propane
Minimum inlet pressure
5.0 in. w.c.
11.0 in. w.c.
Maximum inlet pressure
10.0 in. w.c.
13.0 in. w.c.
Manifold pressure
3.5 in. w.c.
10.0 in. w.c.
Note: Have the gas supply line installed in accordance with
local codes, if any. If not, follow ANSI 223.1. Installation
should be done by a qualifi ed installer approved and/or
licensed as required by the locality. (In the Commonwealth
of Massachusetts installation must be performed by a
licensed plumber or gas fi tter).
Note: A listed (and Commonwealth of Massachusetts
approved) 1/2 in. (13 mm) T-handle manual shut-off valve
and fl exible gas connector are connected to the 1/2 in. (13
mm) control valve inlet.
• If substituting for these components, please consult
local codes for compliance.
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility or
authorities having jurisdiction.
When installing above 2000 feet elevation:
•
In the USA: Reduce burner orifi ce 4% for each 1000 feet
above 2000 feet.
•
In CANADA: Reduce burner orifi ce 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
Fire Risk.
Explosion Hazard.
High pressure will damage valve.
• Disconnect gas supply piping BEFORE
pressure testing gas line at test pressures
above 1/2 psig.
• Close the manual shutoff valve BEFORE
pressure testing gas line at test pressures
equal to or less than 1/2 psig.
WARNING
open fl ames.
Light the appliance. It will take a short time for air to purge
from lines. When purging is complete the appliance will
light and operate normally.
WARNING! Risk of Fire, Explosion or Asphyxiation!
Check all fi ttings and connections with a non-corrosive
commercially available leak-check solution. DO NOT use
open fl ame. Fittings and connections could have loos-
ened during shipping and handling.
WARNING! Risk of Fire! DO NOT change valve settings.
This valve has been preset at the factory.
B. Gas Pressure
•
Optimum appliance performance requires proper input
pressures.
•
Gas line sizing requirements will be determined in ANSI
Z221.3 National Fuel Gas Code in the USA and CAN/
CGA B149 in Canada.
•
Pressure requirements are:
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
49
B. Standing Pilot Ignition System Wiring
•
The standing pilot ignition system wiring does not require
a 110 VAC supply to operate.
•
A 110 VAC junction box MUST be installed for use with
a fan or remote control. See Figure 13.2 for junction box
wiring. Keep wire lengths short as possible.
NOTICE: DO NOT wire 110 VAC to the millivolt valve! This
will damage the valve.
•
If using a thermostat use one compatible with a millivolt
gas valve system:
-
Install the thermostat in the location as indicated
in the thermostat instructions to ensure proper
operation of appliance.
-
Use low resistance thermostat wire for wiring from
ignition system to the wall switch and thermostat.
-
Keep wire lengths short as possible.
A. Wiring Requirements
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
•
Wire the appliance junction box to 110-120 VAC. This is
required for use of optional accessories.
•
A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
•
Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
C. Optional Accessories Requirements
•
This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
13
13 Electrical Information
Wiring for optional Hearth & Home Technologies ap-
proved accessories should be done now to avoid re-
construction. Follow instructions that come with those
accessories.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
50
D. Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to
disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
Figure 13.1 Wiring Diagram
WARNING! Risk of Shock! Replace damaged wire with
type 105° C rated wire. Wire must have high temperature
insulation.
E. Junction Box Installation
If the box is being wired from the OUTSIDE of the appli-
ance:
•
Remove the cover plate located on the outer shell - right
side (see Figure 13.2).
•
Install the supplied Romex™ connector in the cover
plate.
•
Feed the necessary length of wire through the
connector.
•
Make all necessary wire connections and reattach the
cover plate to the outer shell.
WHT
WHT
BLK
BLK
GRN wire
inside box
Copper
ground attached
to GRN screw with
GRN wire
14/2WG
Cover Plate
outside firebox
Romex
Connector
Figure 13.2 Junction Box Detail
If the box is being wired from the INSIDE of the appli-
ance:
•
Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to
disengage it from the outer shell.
•
Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
•
Feed the necessary length of wire through the
connector.
•
Make all necessary wire connections to the junction box/
receptacle and reassemble the junction box/receptacle
to the outer shell.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
51
Mantel
Non-combustible
Face
A
A = 53 in. (1346 mm) min.
Non-combustible Mantel
12 in. (308 mm)
maximum depth
A = 66 in. (1676 mm) min.
Combustible Mantel
Figure 14.1 Minimum Vertical and Maximum Horizontal Dimensions
11 in. (279 mm) Min.
to perpendicular wall
A
12 in. (305 mm) Min.
from fireplace opening
to perpendicular wall
B
Mantel Leg or
Perpendicular Wall
Top of
Appliance
Drywall
A
B
14
14 Finishing
A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be construct-
ed entirely of non-combustible materials (i.e., steel studs,
concrete board, etc).
Figure 14.2 Mantel Leg or Wall Projections (Acceptable on both
sides of opening)
Mantels
Mantel Legs or Wall Projections
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
52
0 in.
0 in.
0 in.
Finish wall material may
be combustible - Top and
Sides
High Temperature Sealant (300° F/149° C min.)
Non-Combustible Zone
These joints
may be taped
and covered
with joint
compound.
B. Facing Material
•
The QFP44 is shipped with non-combustible material
in place. Do not cover or replace this non-combustible
material with combustible materials.
-
The non-combustible front upper can be removed
if replaced with non-combustible materials. See
Section 1.E. for materials that may be used.
•
Combustible fi nish wall material may be butted up to the
unit and the supplied non-combustible material of the
upper front.
-
The unit is shipped with door templates attached.
The wall material should go behind the templates
and butt up to the edge of the unit. Refer to Figure
14.4.
•
The joints at the non-combustible material may be taped
and covered with normal joint compound.
•
Seal joints between the fi nished wall and appliance top
and sides using a 300 °F minimum sealant. Refer to
Figure 14.3.
WARNING! Risk of Fire! DO NOT apply combustible ma-
terials beyond the minimum clearances. Comply with all
minimum clearances to combustibles as specifi ed in this
manual. Overlapping materials could ignite and will inter-
fere with proper operation of doors and louvers.
Figure 14.3 Non-combustible Facing Diagram
Mantel
Non-combustible
Face
A
A = 53 in. (1346 mm) min.
Non-combustible Mantel
12 in. (308 mm)
maximum depth
A = 66 in. (1676 mm) min.
Combustible Mantel
Figure 14.5 Minimum Mantel Heights
Template
Pieces
Figure 14.4 Facing Template
C. Facing Template Removal
There is a metal template on each side and across the
top of the door opening. See Figure 14.4. If using an
inside fi t for the doors, do not remove the templates until
the facing material is installed. If you choose to use an
outside fi t, the templates may be removed before install-
ing the facing material.
•
Side Templates – Remove the screws from the sides of
the door opening and set aside. Remove and discard
the template pieces.
•
Top Template – Loosen the screws across the top of the
opening. Slide the top template out, discard the template
and tighten the screws.
D. Mantel
The mantel may be constructed with combustible or non-
combustible materials as indicated in Figure 14.5
•
Sheetrock/wall material will have been installed (see
Figure 14.3) and the joints fi lled..
•
If installing doors with an outside surface fi t, the facing
templates should be removed (retain the screws for
door installation) and non-combustible facing material
less than one inch thick may be brought to the edge of
the fi replace opening. Doors will be mounted over the
facing material. The door frame is slotted to allow the
door to be mounted up to one inch from the surface of
the unit.
•
If installing doors with a recessed fi t, facing material
must be butted to the fl anges of the facing templates
to allow doors to fi t within the facing material. Once the
facing material is in place, the template must be removed
(retain the screws for door installation).
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
53
15
15 Appliance Setup
C. Install the Refractory
•
Remove the refractory retainer from each side of the
fi rebox.
•
Put the left side refractory in place and reinstall the left
side refractory retainer.
Glass
Latches
Figure 15.1 Glass Assembly Removal
Refractory Retainer
Figure 15.2 Install Left Side Refractory
A. Remove Glass Assembly
WARNING! Risk of Asphyxiation! Handle fi xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.
•
DO NOT strike, slam or scratch glass.
•
DO NOT operate fi replace with glass removed, cracked,
broken or scratched.
•
Replace as a complete assembly.
B. Clean the Appliance
Clean/vacuum any sawdust that may have accumulated
inside the fi rebox or underneath in the control cavity.
WARNING! Risk of Fire and Electric Shock! Use ONLY
Hearth & Home Technologies-approved optional acces-
sories with this appliance. Using non-listed accessories
could result in a safety hazard and will void the warranty.
The glass assembly can be removed from the unit by
pulling and releasing the glass latches. There are three
across the top, three across the bottom, and one in the
center of each side.
The glass assembly is heavy. Use caution when remov-
ing.
•
Install the lower back refractory.
Figure 15.3 Install Lower Back Refractory
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
54
•
Install the upper back refractory.
Figure 15.4 Install Upper Back Refractory
•
Install the right side refractory.
•
Slide the back refractory slightly from side to side as
necessary to close up any gaps in the corners.
•
Install the right side refractory retainer.
Figure 15.5 Install Right Side Refractory
Note: As you use the appliance, expansion and contraction
will cause minor cracking of the refractory. This is normal,
unavoidable, and will not affect the performance of the
appliance. If the cracks become large enough that the
metal behind the refractory is exposed or large pieces
fall out, the panels should be replaced.
IMPORTANT! This appliance should be run
three to four hours on low on the initial start-up.
Turn it off and let it cool completely. Remove and
clean the glass. Reinstall the glass and run the
appliance for an additional 12 hours. This will help
cure the products used in the paint and logs.
Figure 15.6 Adjusting the Air Shutter
D. Adjust the Air Shutter
This appliance has adjustable air shutters (which control
the primary air) factory set in the closed position (approxi-
mately 1/8 in. open). See Figure 15.6.
NOTICE: If sooting occurs, provide more air by opening
the air shutter.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
55
Figure 15.7 Adjust the Vertical Baffl e
Figure 15.8 Positioning Rear Log
F. Install Logs, Ember Bed & Rockwool
•
Remove the grate from the hearth by removing the
screws.
•
Position rear log over the locating tabs at the rear of the
hearth pan. See Figure 15.8.
E. Adjust the Vertical Baffl e
If the vertical run height is more than 12 feet, it may be
necessary to install the vertical baffl es that are included
with the unit to improve the fl ame appearance. Install
each baffl e to cover the outside two slots in the lower
fi rebox top. See Figure 15.7.
Figure 15.9 Positioning Ember Bed
•
Position ember bed over the burner locating the corners
inside the brackets. See Figure 15.9.
•
Position the grate in the recess of the ember bed
and attach to the hearth with the screws. See Figure
14.10.
Figure 15.10 Positioning Grate
•
Position the cut out on the left front log over the grate
bar. See Figure 15.11.
Figure 15.11 Positioning Left Front Log
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
56
•
Position the right front log over the grate bars, aligning
the cut outs on the bottom of the log with the bars. See
Figure 15.12
Figure 15.12 Positioning Right Front Leg
•
Position the cutout on the bottom of the left log over the
locating bracket on the grate. Push the top of the rear
log back against the back refractory and position the left
log on the fl at area of the rear log. See Figure 15.13.
Figure 15.13 Positioning Left Log
•
Position the right log over the locating bracket on the
grate and position the end on the fl at area of the rear
log. See Figure 15.14.
Figure 15.14 Positioning Right Log
•
Place the end of the right middle log on the fl at area
on the ember bed and position the hole in the log over
the exposed locator pin on the front log. See Figure
15.15.
Figure 15.15 Positioning Right Middle Log
•
Place the end of the left middle log on the fl at area of
the ember bed and position the hole in the log over
the exposed locator pin on the front log. See Figure
15.16.
Figure 15.16 Positioning Left Middle Log
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
57
WARNING! Risk of Explosion! Follow rockwool placement
instructions. DO NOT place rockwool directly over burner
ports. Replace rockwool material annually. Improperly placed
rockwool interferes with proper burner operation.
•
Rockwool is shipped with this gas appliance.
•
Place individual pieces of wool loosely in the ember bed
slots. Do not block the burner ports by packing tightly.
Figure 15.17 Placing Rockwool
G. Install Andirons
Install andirons with the screws provided. See Fig-
ure 15.18.
Figure 15.18 Installing Andirons
H. Place Lava Rock and Vermiculite
•
Cover the visible area of the metal hearth pan around
the ember bed with a layer of lava rock.
•
Lightly sprinkle vermicuite over the lava rock.
Figure 15.19 Placing Lava Rock
J. Install Door Fronts
The doors should be lifted off the frame at the hinges to
make installation easier.
•
Make sure the templates have been removed, retain the
screws.
•
Fit the frame inside the unit opening and use the screws
from the facing template to attach the door frame to the
unit.
•
Install the doors by hanging on the hinges.
•
Install the door handles if necessary.
I. Reinstall Glass
•
Reinstall glass by reversing steps in Section 15.A.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
58
A. Standing Pilot Ignition System
16
16 Troubleshooting
With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you
do experience a problem, this troubleshooting guide will assist a qualifi ed service technician in the diagnosis of a problem
and the corrective action to be taken. This troubleshooting guide can only be used by a qualifi ed service technician. Con-
tact your dealer to arrange a service call by a qualifi ed service technician.
Symptom
Possible Causes
Corrective Actions
1
After repeated triggering of
the electronic spark igniter
the pilot will not light.
a.
Defective igniter.
Check the spark at the electrode and pilot. If no spark and electrode wire
is properly connected, replace the igniter AA battery.
b.
Defective pilot or misaligned elec-
trode (spark at electrode).
Use a match to light the pilot. If the pilot lights, turn off the pilot and
trigger the button again. If the pilot lights, an improper gas/air mixture
caused the bad lighting and a longer purge period is recommended. If the
pilot will not light, ensure the gap at the electrode and pilot is 1/8 in. to
have a strong spark. If the gap is OK, replace the pilot.
c.
No gas or low gas pressure.
Check the remote shut-off valves from the fi replace. Usually, there is a
valve near the gas main. There can be more than one valve between the
fi replace and the main.
d.
No LP in the tank.
Check the LP (propane) tank. You may be out of fuel.
2.
The pilot will not stay lit
after carefully following the
lighting instructions.
a.
Defective thermocouple.
Check that the pilot fl ame impinges on the thermocouple. Clean and/or
adjust the pilot for maximum fl ame impingement.
Ensure that the thermocouple connection at the gas valve is fully inserted
and tight (hand tighten plus 1/4 turn).
Disconnect the thermocouple from thh valve, place one millivolt meter
lead wire on the tip of the thermocouple and the other meter lead wire on
the thermocouple copper lead. Start the pilot and hold the valve knob in.
If the millivolt reading is less than 15mV, replace the thermocouple.
b.
Defective valve.
If the thermocouple is producing more than 15 millivolt, replace faulty
valve.
3.
The pilot is burning, there
is no burner fl ame, the
valve knob is in the ON
position, and the MLT OFF/
REMOTE/ON switch is in
the REMOTE position.
a.
Power failure.
Verify that 120 VAC is present at the unit. If power if OFF, the MLT switch
must be placed in the ON position unless an optional wall thermostat
or switch is installed. The optional thermostat or switch will control the
burner operation. The burner defaults to high when power if OFF.
b.
Remote receiver or wires defec-
tive.
Check the RED wires for proper connections. Place a jumper wire across
the TH-TP and TH terminals at the gas valve. If the burner comes on,
remove the jumper and place the MLT switch in the ON position. If the
burner comes ON, refer to the troubleshooting documents for the MLT
remote control.
c.
Thermopile may not be generat-
ing suffi cient millivolt signal.
If the pilot fl ame is not physically close enough to the thermopile, adjust
the pilot fl ame.
Be sure the wire connections from the thermopile at the gas valve
terminals are tight and that the thermopile is fully inserted into the pilot
bracket.
Check the thermopile with a millivolt meter. With the pilot lit, disconnect
the thermopile leads from the valve. Take a reading at the thermopile
leads. The reading should be 325 millivolt minimum. Replace the ther-
mopile if the reading is below the minimum. Reconnect the thermopile
leads. Be sure the wire connections from the thermopile at the gas valve
terminals are tight.
d.
Defective valve.
Turn on the valve knob to the ON position. Place the MLT switch in the
ON position. Check the millivolt meter reading at the thermopile termi-
nals. The millivolt meter should read greater than 125mV. If the reading is
acceptable, and if the burner does not come on, replace the gas valve.
e.
Plugged burner orifi ce.
Check the burner orifi ce for stoppage. Remove stoppage.
f.
Optional wall thermostat wires are
defective.
Disconnect the red MLT wires. Jumper the leads at the wall thermostat
or wall switch. Check the thermostat, switch and wiring. Replace where
defective.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
59
Troubleshooting (continued)
Symptom
Possible Causes
Corrective Actions
4.
Rear burner switch does
not turn OFF the back
burner.
a. Power failure.
Verify that 120 VAC is present at the unit. If power if OFF, the MLT
switch must be placed in the ON position unless an optional wall
thermostat or switch is installed. The optional thermostat or switch will
control the burner operation. The burner defaults to high when power
is OFF.
b. Rear burner switch is defective.
Ensure that the interface is securely attached to the switch.
Jumper the terminals of the switch. If the back burner goes OFF,
replace the switch.
c. 9vdc power supply defective.
Disconnect the power supply from the interface. Use a dc volt meter
on the plug the tip is positive. If the voltage is less than 9vdc, replace
the power supply.
d. Defective interface module.
Disconnect the front solenoid red and black wires. Momentarily touch
to a 9 volt battery. Reverse the battery and momentarily touch to the
battery again. If you hear the solenoid snap when it toggles, replace
the interface module.
Reverse the battery again. If the solenoid does not snap, replace the
solenoid block.
5.
Frequent pilot outage
problem.
a. Pilot fl ame may be too high or low,
or blowing (high), causing pilot
safety to drop out.
Clean and adjust the pilot fl ame for maximum fl ame impingement on
thermocouple. Follow lighting instructions carefully.
6.
The pilot and main
burner extinguish while in
operation.
a. No LP in tank.
Check the LP (propane) tank. Refi ll the fuel tank.
b. Inner vent pipe leaking exhaust
gases back into the system.
Check for gas leaks.
c. Horizontal vent improperly pitched.
The horizontal vent cap should slope down only enough to prevent
any water from entering the unit. The maximum downwards slope is
1/4 in.
d. Glass too loose and air tight packet
leaks in corners after usage.
Tighten the corner.
e. Bad thermopile or thermocouple.
Replace if necessary.
f. Improper vent cap installation.
Check for proper installation and freedom from debris or blockage.
7.
Glass soots.
a. Flame impingement.
Adjust the log set so that the fl ame does not excessively impinge on it.
b. Improper venturi setting.
Adjust the air shutter at the base of the burner.
c. Debris around venturi.
Inspect the opening at the base of the burner. NO MATERIAL
SHOULD BE PLACED IN THIS OPENING.
8.
Flame burns blue and lifts
off burner.
a. Insuffi cient oxygen being supplied.
Ensure that the vent cap is installed properly and free of debris, and
that the vent system joints are tight and have no leaks.
Ensure that no debris has been placed at the base of, or in the area of
the air holes in the center of the base pan beneath the burner.
Ensure that the glass is tightened properly on the unit, particularly on
top corners.
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
60
17
17 Reference Materials
49 in.
1245 mm
40 in.
1016 mm
35-1/2 in.
902 mm
A. Appliance Dimension Diagram
Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5.
Figure 17.1 Appliance Dimensions
10-1/8 in.
257 mm
2-1/4 in.
57 mm
Gas
Line
Electrical
Hookup
2-7/8 in.
73 mm
66-3/8 in.
1686 mm
57-3/4 in.
1467 mm
7-1/4 in.
184 mm
35-5/8 in.
905 mm
15-1/8 in.
384 mm
19-1/5 in.
495 mm
29-1/2 in.
749 mm
25° TYP
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
61
B. Vent Components Diagrams
Figure 17.2 DVP Vent Components
Effective
Height/Length
DVP Pipe
(see chart)
Pipe
inches
mm
DVP4
4
102
DVP6
6
152
DVP12
12
305
DVP24
24
610
DVP36
36
914
DVP48
48
1219
DVP6A
3 - 6
76 - 152
DVP12A
3 - 12
76 - 305
Effective Height/Length
10-1/2 in.
(267 mm)
10-7/8 in.
(276 mm)
DVP45
45° Elbow
45°
4-7/8 in.
(124 mm)
Assembled
Height: 24 in./610 mm
Diameter: 10 in./254 mm
DVP-AS2
10 in.
(254 mm)
1 in.
(25 mm)
DVP-FS
Ceiling Firestop
7-3/8 in.
(187 mm)
11-3/8 in.
(289 mm)
1-1/4 in.
(32 mm)
9-1/4 in.
(235 mm)
13-1/4 in.
(337 mm)
1/2 in.
(13 mm) TYP
DVP90ST
90° Elbow
10 in.
(254 mm)
1-1/2 in.
(38 mm)
5 in.
(127 mm)
12 in.
(305 mm)
DVP-HVS
Vent Support
UP
DVP-WS
Wall Shield Firestop
14 in.
(356 mm)
1 in.
(25 mm)
8 in.
(203 mm)
6 in.
(152 mm)
12 in.
(305 mm)
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
62
B. Vent Components Diagrams (continued)
Figure 17.3 DVP Vent Components
13-1/4 in.
(367 mm)
24-5/8 in.
(625 mm)
27-1/2 in.
(698 mm)
RF6M
Roof Flashing Multi-pak
31 in.
(787 mm)
24-5/8 in.
(625 mm)
13-1/4 in.
(367 mm)
RF12M
Roof Flashing Multi-pak
BEK
Trap Cap Brick Extension
13-3/4 in.
(349 mm)
5 in.
(127 mm)
13-3/4 in.
(349 mm)
DVP-BEK2
DVP-HPC Cap Brick Extension
13-7/8 in.
(352 mm)
5 in.
(127 mm)
11-7/8 in.
(302 mm)
COOL-ADD
Cap Shield
11-5/8 in.
(295 mm)
5-3/4 in.
(146 mm)
7-1/8 in.
(181 mm)
12-1/8 in.
(308 mm)
DRC-RADIUS
Cap Shield
13-7/8 in.
(352 mm)
9-1/2 in.
(241 mm)
14 in.
(356 mm)
DVP-TRAPFL
Flashing
26 in.
(660 mm)
DVP-HSM-B
Extended Heat Shield
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
63
B. Vent Components Diagrams (continued)
Figure 17.4 DVP Vent Components
7-1/4 in.
(184 mm)
5-1/4 in.
(133 mm)
12-1/2 in.
(318 mm)
DVP-TVHW
Vertical Termination Cap (High wind)
14 in.
(356 mm)
12 in.
(305 mm)
12-1/8 in.
(314 mm)
7-1/8 in.
(181 mm)
8-3/4 in.
(222 mm)
1-5/8 in.
(41 mm)
16-7/8 in.
(429 mm)
DVP-HPC
High Performance Cap
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
64
B. Vent Components Diagrams (continued)
Figure 17.5 DVP Vent Components
DVP-TRAP1
DVP-TRAP2
DVP-HPC1
DVP-HPC2
DVP-TRAP
Horizontal Termination Cap
15-1/8 in.
(384 mm)
12 in.
(305 mm)
8 in.
(203 mm)
Max
Effective
Length
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the
existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B
will be required.
Heat
Shield
Term Cap
Minimum
Effective Length
Maximum
Effective Length
Trap1
3-1/8 in.
4-5/8 in.
79 mm
117 mm
Trap2
5-3/8 in.
9-3/8 in.
137 mm
238 mm
Fillers
DVP-TRAP to DVP-HPC Side Filler Kit
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
65
C. Service Parts
QFP44-NG
44 in. Gas Appliance - DV
Beginning Manufacturing Date: Aug 2006
Ending Manufacturing Date: ______
R
13
14
17
18
20
16
19
15
28
29
26
24
22
21
27
23
25
6
3
1
7
4
2
5
Log Set Assembly
Refractory Assembly
Part number list on following page.
8
9
10
11
12
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
66
QFP44-NG
C. Service Parts
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
1
Back Log
SRV4051-134
2
Front Right Log
SRV4051-135
3
Middle Left Log
SRV4051-138
4
Middle Right Log
SRV4051-139
5
Front Left Log
SRV4051-142
6
Top Left Log
SRV4051-136
7
Top Right Log
SRV4051-137
8
Left Refractory
4051-146
9
Upper Back Refractory
4051-149
10
Lower Back Refractory
4051-148
11
Right Refractory
4051-147
12
Refractory Retainer
4013-090
13
Intake Collar Assembly
4002-002
14
Heat Zone Cover Plate
Qty 2 req
4051-122
15
Front Shield
4051-114
16
Glass Clip Assembly
Pkg of 2
33858/2
Y
17
Side Glass Latch assembly
4051-003
Y
18
Burner Assembly
Qty 2 req
4051-008
Y
19
Retainer
4051-124
20
Grate Assembly
4051-012
21
Glass Frame Assembly
SRV4051-005
Y
22
Andiron
4051-311
23
Hearth Pan Support
4051-160
24
Hearth Sheet
4051-125
25
Fan Assembly
4051-007
26
Burner Cover
SRV4051-024
27
Junction Box (plastic)
4021-013
Y
28
Junction Box Cover Plate
4031-222
29
Junction Box Radiation Shield
4047-128
Flue Gasket
4000-225
Vertical Baffl e
Qty 2 req
4051-185
Lava Rock Bag Assembly
4040-094
Lava Rock
4021-296
Mineral Wool
14333B
Vermiculite
28746
Installation Instructions & Owner's Manual
4051-300
Additional service part numbers on following page
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
67
QFP44-NG
QFP44-NG
R
Beginning Manufacturing Date: Aug 2006
Ending Manufacturing Date: ______
30.1
30.2
30.3
30.3
30.5
30.6
30.7
30.8
30.9
30.10
30.11
30.12
30.13
30.14
30.15
30.16
30.17
30.18
30.19
30.20
30.21
30.22
30.23
30.24
30.25
30.26
30.27
30.28
Part number list on following page.
#34 Valve Assembly
C. Service Parts
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
68
QFP44-NG
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement
parts for your appliance please provide model number and serial number. All parts listed
in this manual may be ordered from an authorized dealer.
Stocked
at Depot
ITEM
DESCRIPTION
COMMENTS
PART NUMBER
30.1
Front Orifi ce - NG (#46C)
582-846
Y
Front Orifi ce - LP (#56C)
582-856
Y
30.2
Rear Orifi ce - NG (#18)
4021-376
Y
Rear Orifi ce - LP (#46C)
582-846
Y
30.3
Solenoid Block Assembly
4051-010
Y
30.4
Cover Plate Gasket
4042-306
30.5
Pilot Assembly
230-1781
Y
Thermocouple
200-2950
Y
30.6
Pilot Shield
4051-184
30.7
Valve Bracket
4051-120
30.8
MLT Interface
4021-375
Y
30.9
ON/OFF Rocker Switch
4021-377
Y
30.10
Valve
230-0710
Y
30.11
Male Connector
Pkg of 5
303-315/5
Y
30.12
10” Flex Gas Line
15696B
Y
30.13
On/Off Valve
15697
Y
30.14
Ignition Cable/Switch Assembly
230-1900
Y
30.15
Extension Knob
230-1250
Y
30.16
HI/LO Solenoid
4021-379
Y
30.17
Valve Shield
4051-193
30.18
Dashboard
4051-121
30.19
Conversion Pin - NG
4021-367
Y
Conversion Pin - LP
4021-368
Y
30.20
Solenoid Regulator
4021-378
Y
30.21
1/2 in. to 3/8 in. NPT Flare - Male
4021-373
30.22
10 in., 1/2 in. dia. Flex Gas Line
4021-374
30.23
12V Transformer
2101-290
Y
30.24
Remote Tray
4051-169
30.25
MLT Receiver
HTI-13-006
Y
30.26
Ignition Module
230-1880
Y
30.27
Pilot Support
4051-179
30.28
Pilot Bracket
4051-161
Remote Transmitter
4021-381
Y
Remote Transmitter Wall Holder
HTI-16-006
Y
Conversion Kit - NG
44CKN
Y
Conversion Kit - LP
44CKP
Y
Pilot Injector - 51 - NG
200-2420
Y
Pilot Injector - 35 - LP
200-2630
Y
C. Service Parts
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
69
D. Optional Components
Door (iron full view)
DF-QFP44-IFV
Door (iron operable)
DF-QFP44-IOP
Door (Craftsman operable, black)
DF-QFP44-COP-BK
Door (Craftsman operable, sienna bronz)
DF-QFP44-COP-SB
Wall Thermostat - Manual
812-3760
Wall Thermostat - Programmable
811-0520
Heat Zone Kit
QFP-HEAT-ZONE
Conversion Kit, LP
44CKP
Conversion Kit, NG
44CKN
A
B
C
D
LDS33/LDS46 Decorative Shroud
E
D
A
C
B
LDS-BV Decorative Shroud
20 in.
[508 mm]
17 in.
[432 mm]
9-3/8 in.
[238 mm]
TCG375 Terra Cotta Cap
LDSCP-M Shroud Leg Multipack
(not shown)
See your QuadraFire dealer for a complete listing of optional components.
Catalog #
A
B
C
D
in.
mm
in.
mm
in.
mm
in.
mm
LDS33
36
914
36
914
8.5
216
11
279
LDS46
48
1219
72
1829
8.5
216
11
279
Catalog #
A
B
C
E
E
LDS-BV
in.
26
12.5
15.5
22
23
mm
660
318
394
533
584
Quadra-Fire • QFP44 • 4051-300 • Rev. U • 4/11
70
E. Contact Information
Please contact your Quadra-Fire dealer with any questions or concerns.
For the location of your nearest Quadra-Fire dealer,
please visit www.Quadra-Fire.com.
- NOTES -
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
________________________________________________________________________________
Printed in U.S.A. - Copyright 2011
DO NOT DISCARD THIS MANUAL
NOTICE
• Leave this manual with
party responsible for use
and operation.
• Important operating
and maintenance
instructions included.
• Read, understand and follow
these instructions for safe
installation and operation.
Quadra-Fire, a brand of Hearth & Home Technologies Inc.
7571 215th Street West, Lakeville, MN 55044
www.quadrafi re.com
R
This product may be covered by one or more of the following patents: (United States) 5328356, 5601073, 5613487,
5647340, 5890485, 5941237, 5947112, 5996575, 6006743, 6019099, 6053165, 6145502, 6170481, 6374822, 6484712,
6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729 or other U.S. and foreign patents pending.
2000-945