Furman ITReference20 Owner's Manual

Brand: Furman
Category: Other
Model: ITReference20 (Owner's Manual)
File Type: PDF
File Size: 2.4 Mb
Pages: 12
Text of Furman ITReference20 Owner's Manual

IT-REFERENCE 20 OWNER’S MANUAL

1 The IT-Reference 20 Features • Symmetrical balanced power cancels hum inducing noise from audio and video • Five discrete power banks eliminate inter-component interference and noise • Power Factor correction provides surplus current for power-starved amplifiers • Linear Filtering Technology for unequaled audio / video clarity • Virtually maintenance-free AC surge suppression �
IT-REFERENCE 20 OWNER’S MANUAL Introduction For over 30 years, Furman has pioneered the development of AC power products for the most demanding audio, video, and broadcast professionals. Though the need for pristine AC power is nothing new, the IT-Reference 20’s technology and its unique implementation are revolutionary and without peer. The extreme AC demands encountered in the professional audio/video arena have required technological developments f
IT-REFERENCE 20 OWNER’S MANUAL fast with bass fundamentals that shake foundations with their weight and visceral impact. Mid and high frequencies will bloom with sweet, non-glaring ease while imaging improves dramatically, all the while remaining true to your system’s inherent virtues. Installation: Unpacking Before unpacking your unit, inspect the carton for any obvious severe damage to the box and internal protective materials. If internal damage is
IT-REFERENCE 20 OWNER’S MANUAL 20 is connected should be adequate for use at 20 Amps. Though the system may function with a 15 Amp panel circuit breaker, nuisance circuit breaker tripping could result at your service panel. If your system includes multi- channel audio power amplifi ers that require more than modest power demands, a circuit breaker with a rating of at least 20 Amps is essential for optimum performance. If other electrical loads are used
IT-REFERENCE 20 OWNER’S MANUAL (4) “High Current - Amplifi er Power” outlets. It should be noted that as each AC bank’s outlets are in parallel, component power supply noise could potentially “back-wash” between these units. For this reason it is recommended that systems with minimal componentry (four units or less, excluding the power amplifi ers) utilize one “Discrete” bank per component. This will maximize performance by eliminating i
IT-REFERENCE 20 OWNER’S MANUAL Soft Start - Continuous Use and Break-In Time When power is fi rst applied to the IT-Reference 20, (the front panel breaker- power toggle must be switched to the “on” position) the Soft Start feature is activated. There is an audible “clack” when the IT-Reference is fi rst turned on or off. This sound is produced by the Soft Start circuit’s 30 Amp relay engaging or disengaging. There is nothing in the IT-Refer
IT-REFERENCE 20 OWNER’S MANUAL voltage, so there are no parts to fi x or replace after a transient voltage surge incident. It should be noted, however, that there is no continuous over-under voltage circuitry or regulation within the design. For the IT- Reference 20’s intended user, these features are typically not necessary. If your specifi c application requires AC regulation, over-under voltage power shut-down, or sequenced power distribution,
IT-REFERENCE 20 OWNER’S MANUAL the Warranty Registration was completed either by mailing in the completed warranty card or by registering on-line at the Furman website. Shipping charges to the Furman factory or to an authorized repair location must be prepaid by the purchaser of the product. Furman shall, at its own expense, furnish a replacement product or, at Furman’s option, repair the defective product. Return shipping charges back to purchaser wil
IT-REFERENCE 20 OWNER’S MANUAL 9 claim form (call Furman at (707) 763-1010 to obtain the form). Furman reserves the right to review the damaged Furman product, the damaged connected equipment, and the site where the damage occurred. All cost of shipping damaged equipment to Furman for inspection shall be borne solely by the Purchaser. Damaged equipment must remain available for inspection until the claim is fi nalized. The Connected Equipment Warranty i
IT-REFERENCE 20 OWNER’S MANUAL 10 IT-REFERENCE 20 SPECIFICATIONS AC Current Capacity: Input - 20 Amp capacity required Output - 12 - 20 Amp RMS * (maximum, all outlets combined - continuous) * (Due to the Power Factor Correction circuit, available RMS power varies with the reactance of the load (vector). However, this only affects the circuit breaker for continuous RMS current draw. Since power amplifi ers will require high transient current demands,
IT-REFERENCE 20 OWNER’S MANUAL Furman Sound, Inc. 1997 South McDowell Blvd. Petaluma, California 94954-6919 USA Phone: 707-763-1010 Fax: 707-763-1310 Web: www.furmansound.com E-mail: [email protected] 12/18/04_A

Furman Other Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated
ELITE-15 DM i

PDF Guide (@67O66L), Furman ELITE-15 DM i Other (08-07-2026)

8 1.8 Mb 191 39 08-07-2026
ELITE-15 PF i

User Guide: Furman ELITE-15 PF i (D98F32, Upd.04-07-2026)

12 2.6 Mb 1400 252 04-07-2026
ITReference7

Other #ON9TP7

12 0.26 Mb 1364 260 20-04-2026
ARPRO

Other #3ABNA1

12 2.11 Mb 1443 231 04-08-2026
ITReference20

Furman Other Owner's manual (File: PDF, 12-07-2026)

12 2.4 Mb 167 34 12-07-2026
PST-8

PST-8 (Other ePDF Guide, #V6EC49)

34 0.37 Mb 377 68 29-09-2026
PST10D

Furman PST10D Manual (Owner's manual), @411YJ2

40 0.35 Mb 1221 220 02-06-2026

Other: Similar Manuals