055B Operating And Installation Manual: Key Pages of Document

Part No. 240428

CATALOG NO. 6100.52-K Effective: 3-01-00 Replaces: 3-15-99 ® OPERATING AND INSTALLATION INSTRUCTIONS Models 055B VERSA SPA and HOT TUB HEATER This manual should be maintained in legible condition and kept adjacent to the heater or kept in a safe place for future reference. WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or death. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's pho ...

PART ONE - Owner's Operating Instructions

2 SECTION 1 / START-UP PROCEDURES 2 Before Start-Up 3 Lighting Instructions & Shut-Off Procedures (manually lighted pilot MV) 4 Operating Instructions & Shut-Off Procedures (automatically lighted pilot IID) 5 After Start-Up 5 SECTION 2 / CAUTION 5 SECTION 3 / MAINTENANCE & CARE PROCEDURES 6 Pool & Spa Water Chemistry 6 Winterizing the Pool and Spa Heater 7 PART TWO - Installation / Service Instructions 7 SECTION 1 / RECEIVING EQUIPMENT 7 SECTION 2/GENERAL SPECIFICATIONS 7 SECTION 3 / INSTALLATION INSTRUCTIONS 7 Code Requirements 7 Base Installation 7 Clearances 9 Combustion Air 9 Venting Connections ...

PART ONE - OWNER'S OPERATING INSTRUCTIONS

SECTION 1 / START-UP PROCEDURES BEFORE START-UP BURNERS Clean main burners and air louvers of dust, lint and debris. Keep heater area clear and free from com- bustibles, flammable liquids and chemicals. Do not obstruct the flow of combustion and ventilating air. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLO- SION MAY RESULT, CAUSING PROPERTY DAM- AGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY - READ BEFORE OPERATING 2 WATER First thing, insure that system is filled with water and have pump operating. Water must be flowing through the heater during operation. Fig. #8139s ...

STOP! Read the safety information above.

2. Set the thermostat on the lowest setting. 3. Turn On/Off switch to the "Off" position. 4. Remove heater door panel. 5. Push in gas control knob slightly and turn clock- wise to "Off". NOTE: Knob cannot be turned from "Pilot" to "Off" unless knob is pushed in slightly. Do not force. 6. Wait 5 minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step . 7. Locate pilot mounted on the left side of the burner drawer. For burner drawer location, see location of control section, page 18. HONEYWEL ...

TO TURN OFF GAS TO APPLIANCE

4 1. STOP! Read the safety information above. 2. Set the thermostat to the lowest setting. 3. Turn off all electric power to the appliance. 4. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. 5. Remove heater door panel. 6. Push in gas control knob slightly and turn clock- wise to "Off". Knob cannot be turned to "Off" unless it is pushed in slightly. Do not force. 7. Wait 5 minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety infor- mation previously stated. If you don't smell gas, go to the next step ...

Feel the inlet and outlet pipes. Outlet pipe should be

only slightly warmer than the inlet. It should not be hot. WARNING: Should overheating occur or the gas sup- ply fail to shut off, turn off the manual gas control valve to the appliance. VISUAL INSPECTION With the heater on, remove the door and make a visual check of the pilot and burner. The flame should be blue with a well-defined pattern. 5 SECTION 2 / CAUTION Elevated water temperature can be hazardous, and the U.S. Consumer Product Safety Commission recommends the following guidelines: 1. Spa or hot tub water temperatures should never exceed 104°F (40°C). A temperature of 10 ...

Make visual check of the burner and pilot flame.

Flame pattern on the main burner and pilot is indicated in the previous illustration. Yellow flame means restriction of the air openings. Lifting or blowing flame indicates high gas pressure. Low flame means low gas pressure. Should this occur, shut the heater off and contact your gas supplier or qualified service agency. 5. On indoor heaters, clean room intake openings to assure adequate flow of combustion and ventilation air. CAUTION: Combustion air must not be contaminated by corrosive chemical fumes which can damage the heater and void the warranty. 6. Keep area around heater clear and free from c ...

PART 2 - INSTALLATION / SERVICE INSTRUCTIONS

SECTION 1 / RECEIVING EQUIPMENT On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, a note should be made on the Bill of Lading when signing for equipment. Remove the heater from the carton and if it is damaged, report the damage to the carrier immediately. On occasion, we ship some items loose. Be sure that you receive the number of packages indicated on the Bill of Lading. When ordering parts, you must specify model and serial number of heater. When ordering under warranty conditions, you must also specify date of installation. ...

For clearances from combustible surfaces, see

chart below. Clearances from Combustible construction. Indoor Installation: Top* (Drafthood) - 35"; Vent - 6"; Back - 2"; Right Side - 6"; Left Side - 6"; Floor - 0. Outdoor Installation: Top* (Stackless Top) - unobstructed; Back - 2"; Sides - 6". * Clearance from Top of Vent Terminal For servicing, provide at least 24" in front of the heater for burner tray removal, and at least 18" on the left side of the heater to inspect and delime the heat exchanger. OUTDOOR HEATERS These heaters are design certified for outdoor installation, when equipped with the approved top des- ignated for outdoor u ...

HIGH WIND CONDITIONS (OUTDOOR UNITS ONLY)

In areas where high winds are frequent, it may be necessary to locate the heater a minimum of 3' from high vertical walls, or install a wind break so the heater is not in direct wind current. INDOOR HEATERS The design is also certified for indoor installation when equipped with the approved draft hood. For Canada, indoor installation is restricted to an enclosure that is not occupied and does not directly communicate with occupied area. Refer to the latest edition of CAN/ CGA-B149.1 and B149.2 for specific requirements.Locate heater as close as practical to a chimney or gas vent. Heater must always be vent ...

WARNING: Indoor boilers require a draft hood that

must be connected to a vent pipe and properly vented to the outside. Failure to follow this procedure can cause fire or fatal carbon monoxide poisoning. Vent piping the same size or larger than the draft hood outlet is recommended, however, when the total vent height is at least ten (10) feet (draft hood relief opening to vent terminal), the vent pipe size may be reduced as specified in Chapter 10 of the latest edition of the National Fuel Gas Code, ANSI Z 223. (Canada-CAN/CGA- B149.1 and B149.2). As much as possible avoid long horizontal runs of vent pipe and too many elbows. If instal ...

GAS SUPPLY CONNECTIONS

Gas piping must have a sediment trap ahead of the heater gas controls, and a manual shut-off valve located outside the heater jacket. All gas piping should be tested after installation in accordance with local codes. CAUTION: The heater and its manual shut off valve must be disconnected from the gas supply during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45 KPA). Dissipate test pressure in the gas supply line before reconnecting the heater and its manual shut off valve to gas supply line. FAILURE TO FOLLOW THIS PROCEDURE MAY DAMAGE THE GAS VALVE. OVER PRES- SURED GAS VALVES ARE NOT COVERED B ...

PLUMBING FOR WATER CONNECTIONS

LOCATION The VERSA heater requires water flow and posi- tive pressure to fire and operate properly. It must therefore be installed downstream of the discharge side of the filter pump. A typical installation is plumbed as follows: 1. The inlet side of the filter is plumbed directly to the discharge side of the filter pump: 2. The outlet side of the filter is then plumbed to the inlet of the heater; and 3. The outlet of the heater is plumbed to the return line to the spa. The pump, filter and heater are thus plumbed in series. Plumbing from the heater back to the spa must not have any valves or restriction that could ...

throughout its entire length and must pitch downward

from the valve. No shut-off valve shall be installed between the relief valve and the drain line. Valve lever should be tripped at least once a year to ensure that waterways are clear. ELECTRICAL WIRING NOTE: If it is necessary to replace any of the original wiring, it must be replaced with 105 °C wire or its equivalent, except all black wire must be replaced with 150 °C wire or its equivalent. MILLIVOLT SYSTEM The Millivolt System Residential Heater is equipped with a self-generating electrical system in which the electric current is provided by means of a pilot generator. No external electrical ...

WIRING DIAGRAM KEY

Fig. # 8096 Fig. # S86/S8600 S86 S8600 PINK CONNECTOR BLUE CONNECTOR For 120 V input power to the unit, connect the black wire to the “L1” or hot leg of the power supply. Connect the white wire to the “L2” or neutral leg of the power supply. Attach the wire nut to the red wire. There should be no connection to the red wire for 120V operation. Fig. #9240 For 240 V input power to the unit, connect the black wire to the “L1” or hot leg of the power supply. Connect the red wire to the “L2” or second hot leg of the power supply. Attach the wire nut to the white wire. There should be no connection ...

WIRING DIAGRAM MILLIVOLT UNITS

WITH MECHANICAL THERMOSTAT WIRING DIAGRAM MILLIVOLT UNITS WITH SOLID STATE THERMOSTAT Fig. # 2246e Fig. # 1934e 15 ...

SECTION 4 / SERVICING INSTRUCTIONS

GENERAL LOCATION OF CONTROLS Drain Valve Solid State Thermostat & Ignition Control Pressure Switch Burner & Pilot Thermal Fuse CONTROLS/ADJUSTMENTS/REPLACEMENTS CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. DANGER - SHOCK HAZARD -make sure electrical power to the heater is disconnected to avoid potential serious injury of damage to components. TEMPERATURE CONTROLS The water temperature is controlled by the heater thermostat on the upper front panel of the heater. The control center ...

PRESSURE SWITCH ADJUSTMENT:

1. With pump and heater on, turn adjustment knob (clockwise) until a click is heard from the gas valve. 2. Turn adjustment knob (counter clockwise) 1/4 turn. 3. Turn pump off and on several times. Heater should shut off immediately. If it does not, repeat steps above until proper adjustment is made. Adjustment Knob Fig. # 8069.1 Heat Exchanger Height Heat Exchanger Height Pool or Spa Fig. # 8152.0s NOTE: If heater is installed outside of the limits shown, a flow switch must be used in place of the pressure switch when mounted and wired adjacent to the heater. TWO SPEED PUMPS In some cases, the flow on the low-speed is insu ...

BURNER DRAWER REMOVAL

1. Shut off main electrical power switch to heater. 2. Shut off gas upstream of heater. 3. Remove front door. 4. Disconnect gas line from gas valve. 5. Remove (2) screws that mount burner tray to unit. 6. Disconnect wires that terminate at gas valve, and thermal fuse. 7. Slide out burner tray. 8. Reverse above procedure to reinstall. GAS VALVE REMOVAL 1. Remove burner tray. (See burner tray removal procedure). 2. Disconnect pilot tubing from gas valve. 3. Remove gas valve with manifold from burner tray. 4. Remove manifold from gas valve. 5. Reverse above procedure to re-install. MAIN BURNER AND ORIFICE REMOVAL 1. Remove burner dr ...

Electric Heater PDF Instructions

IA receiver
STIEBEL ELTRON IA receiver
06.08.2026 18 pages

BEDIENUNG UND INSTALLATION OPERATION AND INSTALLATION UTILISATION ET INSTALLATION BEDIENING EN INSTALLATIE OBSLUHA A INSTALACE Funkdimmer für Infrarot-Kurzwellen-Heizstrahler | Radio dimmer for short-wave infrared radiant heaters | Gradateur radio pour radiat Setup instructions for the STIEBEL ELTRON IA receiver Electric Heater. It covers technical specifications, system setup, reset instructions.

111
Chemin'Arte 111
13.07.2026 6 pages

www.cheminarte.com Vertical Glass Panel Heater Instruction Manuel (111 / 112 / 113 / 141) Official user manual for the Chemin'Arte 111 Electric Heater. It provides instructions for setup tips, technical overview, backup procedures.

EasyFire B Model
Sierra Products EasyFire B Model
01.05.2026 2 pages

5061 Brooks St. Ste B Montclair, CA 91763 800-527-4790 Fax 1-909-399-3357 www.sierraproductsinc.net P/N Fan Motor Brush Service 08 10/08 B Model Fan Motor Brush Service Instruction Figure 1 Figure 3 Figure 2 Figure 4 OVERVIEW The EasyFire heater is equipped wi Step-by-step user manual for the Sierra Products EasyFire B Model Electric Heater. The documentation includes details on hardware setup, safety features, installation, service contacts.

NWHO(F)-27
Chromalox NWHO(F)-27
12.04.2026 2 pages

Chromalox ® DIVISION 4 SECTION NWHO SALES REFERENCE DATE SERVICE REFERENCE Installation and RENEWAL PARTS IDENTIFICATION PE437-1 APRIL, 1999 (Supersedes PE437) 161-303184-001 GENERAL INSTALLATION © 2010 Chromalox, Inc. User guidebook for the Chromalox NWHO(F)-27 Electric Heater. The document explains interface navigation, warranty information, user settings, product handling.