DigiTech CONTROL 2 - Brochure
Text of DigiTech CONTROL 2 - Brochure
We at DigiTech are very proud of our products and back up each one we sell
with the following warranty:
1. The warranty registration card must be mailed within ten days after
purchase date to validate this warranty.
2. DigiTech warrants this product, when used solely within the U.S., to be
free from defects in materials and workmanship under normal use and
service.
3. DigiTech liability under this warranty is limited to repairing or replacing
defe
DigiTech CONTROL 2 - 8760 S. Sandy Pkwy.
Sandy, UT 84070, USA
Declares that the product:
Product name:
Control 2
Note: Product name may be suffixed by the letters-EU.
Product option:
None
Conforms to the following Product Specifications:
Safety:
IEC 60065 (7th ed. 2001)
EMC:
EN 55013 (2001 + A1)
EN 55020 (1998)
Supplementary Information:
The product herewith complies with the requirements of
Checking your GSP1101 Software Version................................... 1
Top Panel.................................................................................. 2
Using the Control 2 Remote Foot Controller...................... 5
Modes................................................................................................ 5
5 Patch Mode.....
Congratulations and thank you for purchasing the Control 2 Remote Foot
Controller! The Control 2 will help you get the most out of your GSP, giving
you hands-free access to all the tones and effects your GSP has to offer.
Please take a moment to make sure you have everything that’s included with
your Control 2 Remote Foot Controller purchase:
Control 2 Remote Foot Controller
Controller Cable
The Control 2 Remote Foot Controller is extremely
Bank Down / Bank Up
Press either of these footswitches to scroll through banks (groups) of Factory and
User presets. When either of these footswitches are pressed, the Display shows
the presets contained in each bank, and the preset footswitches will flash (1-5
in 5 Patch mode and 1-10 in 10 Patch mode). Press a footswitch with a flashing
LED to select a preset in the bank. If no preset is selected after 5 seconds (or if a
foot
The Expression Pedal can alternatively turn on and control the Wah effect by
pressing down firmly on the toe switch (this disables control of other parameters
assigned to the Expression Pedal). Press down firmly on the toe switch again
to turn off the Wah effect and switch the pedal back to controlling the saved
expression parameters.
NOTE: Rock the Expression Pedal all the way forward and all the way back each
time you power up the Control 2.
Tuner
The T
Attach one end of the included Controller cable here. Connect the other
end to your GSP unit’s Foot Controller port.
WARNING: Only connect the Control 2 Remote Foot Controller to
the GSP1101 or other DigiTech products which specify a connection to
the Control 2. Do not connect the Control 2 Remote Foot Controller
to Ethernet connections as damage will occur.
Expression 2 Input
Connect an optional expression pedal here using
Using the Control 2 Remote Foot Controller
Modes
The Control 2 operates in one of two modes: 5 Patch Mode or 10 Patch
Mode.
5 Patch Mode
In 5 Patch Mode, the footswitches numbered 1-5 each select a preset (also
known as a “patch”) in the selected bank. There are 20 banks to select from
(you can change banks using the Bank Down/Bank Up footswitches). The
lit footswitch (1-5) indicates the current preset selected in the bank; only one
of the 1-5 footswi
The Control 2 assigns groups of presets (called banks) to the numbered
footswitches. Each bank is a group of 5 presets (5 Patch Mode) or 10 presets
(10 Patch Mode) depending on the foot controller mode selected by the GSP.
Hence, there are 20 banks in 5 Patch Mode and 10 banks is 10 Patch Mode.
To select a new bank and a new preset, follow these steps:
Press either the Bank Down or Bank Up footswitch. The name of
the newly cued bank appea
DigiTech CONTROL 2 - To select a preset in 5 Patch or 10 Patch Mode, follow these steps:
Press one of the footswitches numbered 1-5 (footswitches numbered 1-
10 in 10 Patch Mode). The associated footswitch LED will light and the
preset name and number will appear in the Display.
To select another preset, press another of the footswitches numbered
1-5 (footswitches numbered 1-10 in 10 Patch Mode). The previous
footswitch LED will turn off and the newly press
When you load a preset, some effects may already be on. Those effects will
have a lit LED next to their footswitch(es).
To turn effects on or off using Footswitches 6-10, follow these steps:
Make sure the Control 2 is in 5 Patch Mode (see page 5 for instructions
on how to switch modes).
Press one of the footswitches numbered 6-10. The footswitch’s LED
turns on to indicate the effect is active, or turns off to indicate the effect
is bypassed.
Bounce Back
Volume Update lets you maintain relative volume levels between presets
when using the Control 2’s expression pedal as a volume controller. Using
this feature requires that presets have the Control 2’s built-in expression
pedal, an external expression pedal connected to the GSP or Control 2, or a
MIDI expression pedal linked to the Volume Pre or Volume Post parameters
in the GSP’s presets. With Volume Update set to ON, the pedal’s po
knob to select it.
To enable CC send and assign a MIDI CC that the CONTROL
Footswitch will transmit, highlight FC FSW and press the Edit/Select
knob.
Turn the Edit/Select knob to select a MIDI CC and press the knob to
select it.
Expression Pedal Calibration
In order to smoothly control parameters using the Control 2’s expression
pedal, the pedal needs to be calibrated the first time it is connected to the
GSP. This is done using the FC Pedal Calibrate m
DigiTech CONTROL 2 - The Control 2 provides access to the host GSP’s tuner and provides tuner
feedback via the Control 2’s Display.
To tune your guitar, follow these steps:
Press the TUNER footswitch. The Control 2’s Display will briefly show
TUNER and the Tuner footswitch LED will now be lit. The guitar
signal is normally muted when the tuner is accessed. You can rock the
Expression Pedal forward to hear the note while it is being tuned.
Begin playing a note o
Turn the Edit/Select knob until appears.
Press the Edit/Select knob. The Linking menu appears.
Scroll down and highlight LINKED TO NO LINK. Press the Edit/Select
knob.
Turn the Edit/Select knob to select a parameter to assign to the
Control footswitch and press the Edit/Select knob.
Pressing the CONTROL footswitch now toggles between the selected
parameter’s Min and Max values. The Min and Max values are automatically
updated with the selected p
The Min and Max values are automatically updated with the selected
parameter’s defaults. You can also edit the Min and Max values to customize
the parameter range for your needs using the Edit/Select knob.
Changes must be stored using the GSP’s Store procedure. Consult your GSP
documentation for more information about storing changes to presets.
13
Control 2 Owner’s Manual
Using the Control 2 Remote Foot Controller
8760 South Sandy Parkway
Sandy, Utah 84070
PH (801) 566-8800
FAX (801) 566-7005
http://www.digitech.com
Printed 12/2007
Control 2 Remote Foot Controller Owner’s Manual
18-0632-A
© 2007 Harman International Industries, Incorporated. All Rights Reserved.