Sharp R1871 - Convection Microwave Installation Manual

Text of Sharp R1871 - Convection Microwave Installation Manual

Sharp R1871 - Convection Microwave 2 WALL CONSTRUCTION

This Microwave Oven/Hood should be mounted against and sup- ported by a flat vertical wall. The wall must be flat for proper installation. If the wall is not flat, use spacers to fill in the gaps. Wall construction should be a minimum of 2" x 4" wood studding and 3/8" or more thick dry wall or plaster/lath. The mounting sur- faces must be capable of supporting weight of 110 pounds—the oven and contents—AND the weight of all items wh

Sharp R1871 - Convection Microwave 3 ELECTRICAL GROUNDING INSTRUCTIONS

This appliance must be grounded. This oven is equipped with a cord having a grounding wire with a ground- ing plug. It must be plugged into a wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local codes and ordinances. In the event of an electrical short circuit, ground- ing reduces risk of electric shock by providing an escape wire for the electric current. WARN

6 INSTALLATION HARDWARE

The INSTALLATION HARDWARE (items 1-7) packed with the oven should contain the following: ITEM NAME QUANTITY PART CODE 1 Wood Screw 5 X 30 mm 6 XTSS750P35000 2 Toggle Bolt #10 - 24 X 50 mm 4 LX-BZ0195WRE0 3 Top Cabinet Screw 5 X 60 mm 2 XBRS750P60000 4 Flat Washer 30 mm diameter 2 XWHS750-16300 5 Grommet 1 LBSHC0040MRE0 6 Tapping Screw 4 x 12 mm 1 XOTS740P12000 7 Exhaust Damper Assembly 1 FFTA-B004MRK0 Figure 5 7 PREPARATION OF THE

8 PREPARATION OF THE OVEN

1. Rest the oven on its side as shown in Figure 7. Place portion (C) of the carton underneath to protect the outercase from being damaged. 2. Remove the two screws which secure the mounting plate to the rear side of the oven. Remove the mounting plate. The two screws can be discarded. NOTE: If the unit you purchased does not have the mounting plate attached to the rear side of the oven, please disregard this section and continue t

C. VERTICAL EXHAUST: Outside Ventilation

1. Remove and save the 4 screws from the Fan Cover Bracket. Remove Fan Cover Bracket by sliding it in the opposite direction of the arrow on the Fan Cover Bracket as shown in Figure 13. 2. Lift the Hood Fan Unit carefully and slip wires out of cavity. See Figure 14. CAUTION: Do not pull or stretch hood fan wiring. 3. Rotate the Hood Fan Unit 180˚ so that the fan blade openings are facing the b

10 OVEN INSTALLATION

THIS OVEN CANNOT BE PROPERLY INSTALLED WITHOUT REFERRING TO THE MOUNTING INSTRUCTIONS FOUND ON BOTH TEMPLATES. READ AND FOLLOW MOUNTING INFORMATION ON BOTH TOP CABINET AND WALL TEMPLATES. MOUNTING PLATE 1. Separate 4 Toggle Bolts 2, packed in the INSTALLATION HARDWARE, from the Toggle Nuts. 2. Use Wood Screws 1 to attach Mounting Plate to the stud or studs. Use Toggle Bolts to attach Mounting Plate through the holes at A, B, C and D;

4. Thread the power supply cord through the hole made in the bot-

tom of the top cabinet. 5. Hang the oven on the lower edge of the mounting plate. Rotate the unit upward. See Figure 22. Take care that the power cord is able to clear the edge of the hole as the oven is rotated upward. (In the case of a non-recessed bottom in the top cabinet, the hole for the cord may need to be enlarged.) Remove the carton portions. 6. Tighten the two unit mounting screws

CHECK LIST FOR INSTALLATION

1. Make sure the unit has been installed according to all of the Installation Instructions, the Top Template and Wall Template. 2. Remove all packing material from the oven. 3. Plug in the power cord. 4. Read the Operation Manual. 5. Keep the Installation Instructions for the local electrical inspector’s use. ACCESSORIES Check with your dealer or order directly from the SHARP Accessories and Supplies Center. Call toll-free 1

Sharp Microwave Oven Owners Instructions: