Sharp KB-6024MS Service Manual
Text of Sharp KB-6024MS Service Manual
In the interest of user-safety the unit should be restored to its original condition and only parts identical to those specified should
be used.
WARNING TO SERVICE PERSONNEL:
This service manual is intended for use by persons having electrical and mechanical training and a level of
knowledge of these subjects generally considered acceptable in the appliance repair trade. Sharp Electronics
Corporation cannot be responsible,
PRECAUTIONS TO BE OBSERVED BEFORE AND DUR-
ING SERVICING TO AVOID POSSIBLE EXPOSURE TO
EXCESSIVE MICROWAVE ENERGY
(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave
source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing
surfaces (arci
WARNING TO SERVICE PERSONNEL
Microwave Oven units contain circuitry capable of producing very high voltage and current,
contact with following parts may result in a severe, possibly fatal, electrical shock.
(Example)
High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Rectifier
Assembly, High Voltage Harness, Heating Elements, etc..
Read the Service Manual carefully and follow all instruc
Sharp KB-6024MS MICROWAVE MEASUREMENT PROCEDURE
A. Requirements:
1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave
oven should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to
acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more
from the external surface of the o
SHARP ELECTRONICS CORPORATION
SHARP PLAZA, MAHWAH,
NEW JERSEY 07430-2135
SERVICE MANUAL
MICROWAVE DRAWERS
KB-6024MS / KB-6024MK / KB-6024MW
KB-6025MS / KB-6025MK / KB-6025MW
FOREWORD
This Manual has been prepared to provide Sharp Electronics Corp.
Service Personnel and Service Information for the MICROWAVE
DRAWERS, KB-6024MS, KB-6024MK, KB-6024MW and KB-6025MS,
KB-6025MK, KB-6025MW.
It is recommended that service personnel c
14.5 Amperes, 1000 watts
60 Hz
Single phase, 3 wire grounded
Power Output
1000 watts (IEC TEST PROCEDURE)
Operating frequency of 2450MHz
Cooking Cavity Dimensions
KB6024 Width 17-11/32
KB6025 Width 17-11/32
Height 5-7/8"
Height 5-7/8"
1.0 Cubic Feet
Depth 17-1/8"
Depth 17-1/8"
Outside Dimensions
KB6024 Width 23-7/8"
This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed
and grounded in accordance with the National Electrical Code and local codes and ordinances.
In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the
electric current.
WARNING:
Improper use
DESCRIPTION OF OPERATING SEQUENCE
The following is a description of component functions dur-
ing oven operation.
OFF CONDITION
Closing the drawer activates the door sensing switch and
secondary interlock switch. (In this condition, the monitor
switch contacts are opened.)
When oven is plugged in, 120 volts A.C. is supplied to the
control unit. (Page 10).
1. The display will show flashing "Enjoy Your Drawer Touch
C
Sharp KB-6024MS SENSOR COOKING CONDITION
Using the SENSOR function, food is cooked without figur-
ing time, power level or quantity. When the oven senses
enough steam from the food, it relays the information to its
microprocessor which will calculate the remaining cooking
time and power level needed for best results. When the food
is cooked, water vapor is developed. the sensor "senses"
the vapor and its resistance increase gradually.
NOISE SUPRESSION COIL
RESISTOR 470 k?
1/2W
LINE CROSS CAPACITOR 1.0 ? F 275V
LINE BYPASS CAPACITOR
0.0033 ? F 250V
FUSE
20A
FAN MOTOR
OVEN LAMP
MONITOR SWITCH
PRIMARY INTERLOCK RELAY
H.V. RECTIFIER
MAGNETRON
POWER TRANSFORMER
CAPACITOR
1.00 ? F
AC 2300V
STIRRER
MOTOR
CONTR OL UNIT
MICROWAVE DRAWER
S WITCHING R E GULATOR
OVEN
THERMAL
CUT-OUT
MG
THERMAL
CUT-OUT
SECONDARY INTELOCK SWITCH
MICROWAVE DRAWER
DOOR O
unlike conventional microwave ovens, proper maintenance cannot be performed with only a voltmeter
and ohmmeter.
In this service manual, the touch control panel assembly is divided into three units, Control Unit,
Keyboard Unit and Power Unit, and troubleshooting by unit replacement is described according to the
symptoms indicated.
Before testing,
1) Disconnect the power supply
4) Reconnect all leads removed from components during testing.
5) Re-install the covers.
6) Reconnect the power supply cord after the covers are installed.
7) Run the oven and check all functions.
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
B
KEY UNIT TEST
1. Disconnect the power supply cord, and then remove outer case.
1. Disconnect the power supply cord, and then remove
Sharp KB-6024MS WARNING : The oven should be fully assembled before following procedure.
(1) Place one cup of water in the center of the tray in the oven cavity.
(2) Close the drawer, touch the Defrost pad. Then select Steaks/Chops by touching the number pad
2. And touch the number pad 5. (Now, weight 0.5lb is set.) And then touch the start pad.
(3) The oven is in Defrost cooking condition.
(4) The oven will operate as follows
WEIGHT
1
WARNING : The oven should be fully assembled before following procedure. (1) The oven should be plugged in at least two minutes before sensor cooking.
(2) Room temperature should not exceed 95
οF (35
οC).
(3) The unit should not be installed in any area where heat and steam are generated. The unit should not be
installed, for example, next to a conventional surface unit. Refer to the “INSTALLATION INSTRUCTIONS”
of
9-2. Place the container on the center of tray in the oven cavity.
9-3. Close the drawer.
9-4. Touch the TIMER/CLOCK pad once, the POWER LEVEL pad twice and the START pad once. And
touch the number pads 1 once and the number pad 4 once.
9-5. The control panel is in automatic Sensor operation.
9-6. The oven turns off automatically, and the time for detecting moisture will be di
2. Open the drawer and keep it open.
3. To discharge high voltage capacitor, wait for 60 seconds.
4. To test for an open filament, isolate the magnetron from the high voltage circuit. A continuity check across
the magnetron filament leads should indicate less than 1 ohm.
5. To test for a shorted magnetron, connect the ohmmeter leads between the magnetron filament leads
and chassis ground. This test should indicate an in
Sharp KB-6024MS SECONDARY INTERLOCK SWITCH TEST
STOP SWITCH
1. Disconnect the power supply cord.
2. Open the drawer and keep it open.
3. To discharge high voltage capacitor, wait for 60 seconds.
4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO)
terminal of the switch. The meter should indicate an open circuit with the drawer open and a closed
circuit with the drawer closed. If improper operati
POWER TRANSFORMER TEST
1. Disconnect the power supply cord.
2. Open the drawer and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the primary input terminals and measure the resistance of the transformer with an
ohmmeter. Check for continuity of the coils with an ohmmeter. On the R x 1 scale, the resistance
of the primary coil should be less than 1 ohm
TOUCH CONTROL PANEL ASSEMBLY
OUTLINE OF TOUCH CONTROL PANEL
The touch control section consists of the following units.
(1) Key unit
(2) Control Unit
(3) Power unit
The principal functions of these units and the signals com-
municated among them are explained below.
Key unit
The key unit is composed of a matrix, signals generated in
the LSI are sent to the key unit from P10 - P17.
When a key pad is touched, a signal is compl
1 - 3
AN5- AN3
IN
Terminal to change cooking input according to the Model.
By using A/D converter contained in the LSI, DC voltage in accordance with the Model
in operation is applied to set up its cooking constant.
4
AN2
IN
Input signal which inform the drawer door is in the middle position between the opened
position and the closed position, to LSI from the door position switch rear.
5
AN1
IN
Terminal not used.
6
AN0
IN
T