Sharp R-1211F Supplemental Manual
Text of Sharp R-1211F Supplemental Manual
In the interest of user-safety the oven should be restored to its original condition and only parts identical to those specified
should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens contain circuitry capable of producing very high voltage and
current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor,
High Voltage Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Volta
1.CIRCUITS / WIRE COLORS SUBJECT TO CHANGE WITHOUT NOTICE.
2. TERMINAL WITH PROJECTION OR OPPOSITE BLUE MARK ON LAMP SOCKET
MUST BE CONNECTED TO NEUTRAL WIRE.
3. ONLY CERTAIN MODELS USE THE ABSOLUTE HUMIDITY SENSOR.
4. POWER TRANSFORMER LEFT (FINISH LEAD) TERMINAL MUST BE CONNECTED TO THE NEUTRAL (WHITE) WIRE.
H
CAVITY
TEMPERATURE
FUSE
120VAC
60Hz
N
COM.
RED
WHT
WHT
WHT
GRY
BLK
WHT
WHT
WHT
RED
RED
WHT
WHT
WHT
BLK
GRN
N.O.
B1
B2
C