Sharp R-1482 Service Manual

Text of Sharp R-1482 Service Manual

In the interest of user-safety the oven should be restored to its original

condition and only parts identical to those specified should be used. WARNING TO SERVICE PERSONNEL: Microwave ovens con- tain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Recti- f

PRECAUTIONS TO BE OBSERVED BEFORE AND

DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY (a) Do not operate or allow the oven to be operated with the door open. (b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and o

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of pro- ducing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (Example) High Voltage Capacitor, High Voltage Power Trans- former, Magnetron, High Voltage Rectifier Assem- bly, High Voltage Harness etc.. Read the Service Manual carefully and follow all instructions. Before Servicing 1. Disconn

MICROWAVE MEASUREMENT PROCEDURE

A. Requirements: 1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external surface of the oven. 2) Saf

SHARP ELECTRONICS CORPORATION

SHARP PLAZA, MAHWAH, NEW JERSEY 07430-2135 SERVICE MANUAL OVER THE RANGE MICROWAVE OVEN R-1480 / R-1481 / R-1482 FOREWORD This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP OVER THE RANGE MICROWAVE OVEN, R-1480, R-1481, R-1482. It is recommended that service personnel carefully study the entire text of this manual so th

Sharp R-1482 120 Volts / 14.3 Amperes

60 Hertz Single phase, 3 wire grounded Power Output 950 watts (IEC-705 TEST PROCEDURE) Operating frequency of 2450MHz Convection Power Output 1700 watts Case Dimensions Width 29-15/16" Height 16-3/8" Depth 15- 1/4" (Not including the door handle) Cooking Cavity Dimensions Width 20-1/4" Height 8-3/16" 1.4 Cubic Feet Depth 14-1/2" Hood lamp 2 bulbs, 30W x 2, Incandescent l

The oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE

GROUNDING PIN FROM THE PLUG. The power supply cord and plug must be connected to a separate 120 Volt AC, 60 Hz, 15 Amp. or more branch circuit, using a grounded receptacle. The receptacle should be located inside the cabinet directly above the Microwave Oven/Hood system mounting location. OVEN DIAGRAM 1. Oven d

Sharp R-1482 MIX CONV COOK LBS KG TURNTABLE OFF HELP

CONTROL PANEL OPERATION DESCRIPTION OF OPERATING SEQUENCE The following is a description of component functions during oven operation. OFF CONDITION Closing the door activates the door sensing switch and secondary interlock switch. (In this condition, the monitor switch contacts are opened.) When oven is plugged in, 120 volts A.C. is supplied to the control unit. (Figure O-1). 1. The display w

Sharp R-1482 Oven lamp / Fan motor / Stirrer motor

RY2 Power transformer RY3 Turntable motor RY4 Hood fan motor 2. 120 volts A.C. is supplied to the primary winding of the power transformer and is converted to about 3.3 volts A.C. output on the filament winding, and approximately 2000 volts A.C. on the high voltage winding. 3. The filament winding voltage heats the magnetron filament and the H.V. winding voltage is

2. HORIZONTAL VENTING

The air handing is the same as VERTICAL VENTING except that the final air discharge is directed horizontally out from the top rear of the oven into the customer's vent system. _: AIR FLOW 3. RE-CIRCULATION (INSIDE VENTING) The air handing is the same as VERTICAL VENTING except that the final air discharge is directed horizontally through the upper front of the oven into the kitchen. IN this case, the accessory

NOTE: CONDITION OF OVEN

1. DOOR CLOSED 2. COOKING TIME PROGRAMMED 3. VARIABLE COOKING CONTROL "HIGH" 4. "START" PAD TOUCHED Figure O-2. Oven Schematic-Cooking Condition Figure O-1. Oven Schematic-Off Condition SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED 2. CLOCK APPEARS ON DISPLAY MAGNETRON TEMPERATURE FUSE FUSE 20A TURNTABLE MOTOR FAN MOTOR STIRRER MOTOR MAGNETRON OVEN LAMP MONITOR SWITCH BLK WHT POWER TRANSFORMER HI

DESCRIPTION AND FUNCTION OF COMPONENTS

DOOR OPEN MECHANISM The door is opened by pulling the door handle, refer to the Figure D-1. CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE TEST THE DOOR SENSING SWITCH, PRIMARY INTERLOCK RELAY (RY2), SEC- ONDARY INTERLOCK SWITCH AND MONI- TOR SWITCH FOR PROPER OPERATION. (REFER TO CHAPTER "TEST PROCEDURE"). NOTE: MONITOR FUSE AND SWITCH ARE REPLACED AS AN ASSEMBLY TEMPERATURE FUSE (MG) The temp

Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected.

When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the "Test Procedure "section. IMPOR

CK = Check / RE = Replace

POSSIBLE CASE AND DEFECTIVE PARTS PROBLEM TEST PROCEDURE CONDITION OFF CONDITION IDLE CONDITION MICROWAVE COOKING CONDITION Home fuse blows when power cord is plugged into wall receptacle. Monitor fuse blows when power cord is plugged into wall receptacle. Display does not illuminate when power cord is first plugged into wall receptacle. Display does not operate properly when STOP/CLEAR key is touched. (The

POWER TRANSFORMER TEST

TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. To test for an open filament, isolate the magnetron from the high voltage circuit. A continuity check across the magnetron filament leads should indicate less than 1 ohm. 5. To test for a shorted magnetron, connect the ohm

1. Disconnect the power supply cord, and then remove outer case.

2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the capacitor is open, no high voltage will be available to the magnetron. Disconnect input leads and check for short or open between the terminals using an ohmmeter. Checking with a high ohm scale, if the high voltage capacitor is normal, the
1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Before performing this test, make sure that the secondary interlock switch and the primary interlock relay are operating properly, according to the above Switch Test Procedure. Disconnect the wire lead from the monitor switch (COM) terminal. Check

Sharp Microwave Oven Owners Instructions: