Sharp R-1482 Service Manual
Text of Sharp R-1482 Service Manual
In the interest of user-safety the oven should be restored to its original
condition and only parts identical to those specified should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens con-
tain circuitry capable of producing very high voltage and
current, contact with following parts may result in a severe,
possibly fatal, electrical shock. (High Voltage Capacitor, High
Voltage Power Transformer, Magnetron, High Voltage Recti-
f
PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE
ENERGY
(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3)
seal and sealing surfaces (arcing, wear, and o
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of pro-
ducing very high voltage and current, contact with
following parts may result in a severe, possibly
fatal, electrical shock.
(Example)
High Voltage Capacitor, High Voltage Power Trans-
former, Magnetron, High Voltage Rectifier Assem-
bly, High Voltage Harness etc..
Read the Service Manual carefully and follow all
instructions.
Before Servicing
1. Disconn
MICROWAVE MEASUREMENT PROCEDURE
A. Requirements:
1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven
should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition
by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external
surface of the oven.
2) Saf
SHARP ELECTRONICS CORPORATION
SHARP PLAZA, MAHWAH,
NEW JERSEY 07430-2135
SERVICE MANUAL
OVER THE RANGE
MICROWAVE OVEN
R-1480 / R-1481 / R-1482
FOREWORD
This Manual has been prepared to provide Sharp Electronics Corp.
Service Personnel with Operation and Service Information for the
SHARP OVER THE RANGE MICROWAVE OVEN, R-1480, R-1481,
R-1482.
It is recommended that service personnel carefully study the entire
text of this manual so th
Sharp R-1482 120 Volts / 14.3 Amperes
60 Hertz
Single phase, 3 wire grounded
Power Output
950 watts (IEC-705 TEST PROCEDURE)
Operating frequency of 2450MHz
Convection Power Output
1700 watts
Case Dimensions
Width 29-15/16"
Height 16-3/8"
Depth 15- 1/4" (Not including the door handle)
Cooking Cavity Dimensions
Width 20-1/4"
Height 8-3/16"
1.4 Cubic Feet
Depth 14-1/2"
Hood lamp
2 bulbs, 30W x 2, Incandescent l
The oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE
GROUNDING PIN FROM THE PLUG.
The power supply cord and plug must be connected to a separate 120 Volt AC, 60 Hz, 15 Amp. or more branch circuit, using
a grounded receptacle. The receptacle should be located inside the cabinet directly above the Microwave Oven/Hood
system mounting location.
OVEN DIAGRAM
1. Oven d
Sharp R-1482 MIX CONV COOK LBS KG TURNTABLE OFF HELP
CONTROL PANEL
OPERATION
DESCRIPTION OF OPERATING SEQUENCE
The following is a description of component functions during
oven operation.
OFF CONDITION
Closing the door activates the door sensing switch and
secondary interlock switch. (In this condition, the monitor
switch contacts are opened.)
When oven is plugged in, 120 volts A.C. is supplied to the
control unit. (Figure O-1).
1. The display w
Sharp R-1482 Oven lamp / Fan motor / Stirrer motor
RY2
Power transformer
RY3
Turntable motor
RY4
Hood fan motor
2. 120 volts A.C. is supplied to the primary winding of the
power transformer and is converted to about 3.3 volts
A.C. output on the filament winding, and approximately
2000 volts A.C. on the high voltage winding.
3. The filament winding voltage heats the magnetron
filament and the H.V. winding voltage is
2. HORIZONTAL VENTING
The air handing is the same as VERTICAL VENTING
except that the final air discharge is directed horizontally
out from the top rear of the oven into the customer's vent
system.
_: AIR FLOW
3. RE-CIRCULATION (INSIDE VENTING)
The air handing is the same as VERTICAL VENTING
except that the final air discharge is directed horizontally
through the upper front of the oven into the kitchen. IN
this case, the accessory
NOTE: CONDITION OF OVEN
1.
DOOR CLOSED
2.
COOKING TIME PROGRAMMED
3.
VARIABLE COOKING CONTROL "HIGH"
4.
"START" PAD TOUCHED
Figure O-2. Oven Schematic-Cooking Condition
Figure O-1. Oven Schematic-Off Condition
SCHEMATIC
NOTE: CONDITION OF OVEN
1.
DOOR CLOSED
2.
CLOCK APPEARS ON DISPLAY
MAGNETRON
TEMPERATURE FUSE
FUSE
20A
TURNTABLE
MOTOR
FAN
MOTOR
STIRRER
MOTOR
MAGNETRON
OVEN LAMP
MONITOR
SWITCH
BLK
WHT
POWER
TRANSFORMER
HI
DESCRIPTION AND FUNCTION OF COMPONENTS
DOOR OPEN MECHANISM
The door is opened by pulling the door handle, refer to the
Figure D-1.
CAUTION: BEFORE REPLACING A BLOWN MONITOR
FUSE TEST THE DOOR SENSING SWITCH,
PRIMARY INTERLOCK RELAY (RY2), SEC-
ONDARY INTERLOCK SWITCH AND MONI-
TOR SWITCH FOR PROPER OPERATION.
(REFER TO CHAPTER "TEST PROCEDURE").
NOTE: MONITOR FUSE AND SWITCH ARE REPLACED
AS AN ASSEMBLY
TEMPERATURE FUSE (MG)
The temp
Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected.
When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many
of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which
will be found in the "Test Procedure "section.
IMPOR
CK = Check / RE = Replace
POSSIBLE CASE AND
DEFECTIVE PARTS
PROBLEM
TEST PROCEDURE
CONDITION
OFF
CONDITION
IDLE
CONDITION
MICROWAVE
COOKING
CONDITION
Home fuse blows when power cord is plugged into wall receptacle.
Monitor fuse blows when power cord is plugged into wall receptacle.
Display does not illuminate when power cord is first plugged into wall
receptacle.
Display does not operate properly when STOP/CLEAR key is touched.
(The
POWER TRANSFORMER TEST
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. To test for an open filament, isolate the magnetron from the high voltage circuit. A continuity check
across the magnetron filament leads should indicate less than 1 ohm.
5. To test for a shorted magnetron, connect the ohm
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. If the capacitor is open, no high voltage will be available to the magnetron. Disconnect input leads
and check for short or open between the terminals using an ohmmeter.
Checking with a high ohm scale, if the high voltage capacitor is normal, the
1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Before performing this test, make sure that the secondary interlock switch and the primary interlock
relay are operating properly, according to the above Switch Test Procedure. Disconnect the wire lead
from the monitor switch (COM) terminal. Check