Sharp R-1490 Service Manual

Text of Sharp R-1490 Service Manual

In the interest of user-safety the oven should be restored to its original

condition and only parts identical to those specified should be used. WARNING TO SERVICE PERSONNEL: Microwave ovens con- tain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Recti- f

Sharp R-1490 PRECAUTIONS TO BE OBSERVED BEFORE AND

DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY (a) Do not operate or allow the oven to be operated with the door open. (b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and o

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of pro- ducing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (Example) High Voltage Capacitor, High Voltage Power Trans- former, Magnetron, High Voltage Rectifier Assem- bly, High Voltage Harness etc.. Read the Service Manual carefully and follow all instructions. Before Servicing 1. Disconn

MICROWAVE MEASUREMENT PROCEDURE

A. Requirements: 1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external surface of the oven. 2) Saf

Sharp R-1490 SHARP ELECTRONICS CORPORATION

SHARP PLAZA, MAHWAH, NEW JERSEY 07430-2135 SERVICE MANUAL OVER THE RANGE MICROWAVE OVEN R-1490/ R-1491/1492 FOREWORD This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP OVER THE RANGE MICROWAVE OVEN, R-1490/ R-1491/ R1492. The models R-1490, R-1491 and R-1492 is quite similar to base models R-1480/81/82 (Refer No. is S380

120 Volts / 14.3 Amperes

60 Hertz Single phase, 3 wire grounded Power Output 950 watts (IEC-705 TEST PROCEDURE) Operating frequency of 2450MHz Convection Power Output 1700 watts Case Dimensions Width 29-15/16" Height 16-3/8" Depth 15- 1/4" (Not including the door handle) Cooking Cavity Dimensions Width 20-1/4" Height 8-3/16" 1.4 Cubic Feet Depth 14-1/2" Hood lamp 2 bulbs, 30W x 2, Incandescent l

The oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE

GROUNDING PIN FROM THE PLUG. The power supply cord and plug must be connected to a separate 120 Volt AC, 60 Hz, 15 Amp. or more branch circuit, using a grounded receptacle. The receptacle should be located inside the cabinet directly above the Microwave Oven/Hood system mounting location. CONTROL PANEL 3-Prong

DESCRIPTION OF OPERATING SEQUENCE

SENSOR COOKING CONDITION Using the INSTANT SENSOR function, the foods are cooked or defrosted without figuring time, power level or quantity. When the oven senses enough steam from the food, it relays the information to its microprocessor which will calcu- late the remaining cooking time and power level needed for best results. When the food is cooked, water vapor is developed. The sensor �

NOTE: CONDITION OF OVEN

1. DOOR CLOSED 2. COOKING TIME PROGRAMMED 3. VARIABLE COOKING CONTROL "HIGH" 4. "START" PAD TOUCHED Figure O-2. Oven Schematic-Cooking Condition Figure O-1. Oven Schematic-Off Condition SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED 2. CLOCK APPEARS ON DISPLAY CAVITY THERMAL CUT-OUT MAGNETRON TEMPERATURE FUSE FUSE 20A TURNTABLE MOTOR FAN MOTOR STIRRER MOTOR MAGNETRON OVEN LAMP MONITOR SWITCH BLK W

Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected.

When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the "Test Procedure "section. IMPORT

Sharp R-1490 KEY UNIT TEST

1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable is making good contact, verify that the door sensing switch (stop switch) operates properly; that is the contacts are closed when

(1) Fill approximately 200 milliliters (7.2 oz) of tap water in a 1000 milliliter measuring cup.

(2) Place the container on the center of tray in the oven cavity. (3) Close the door. (4) Touch Reheat pad once and touch the Start pad, Now, the oven is in the sensor cooking condition and “REHEAT” "SENSOR" and "COOK" will appear in the display. (5) The oven will operate for the first

Sharp R-1490 Sensor Dummy Resistor Circuit

R1, R2 : 22Ω ± 1% 1/2W R3 : 4.3kΩ ± 5% 1/4W R4 : 1MΩ ± 5% 1/4W Plunger NC NO COM COM NO NC R3 R4 R1 R2 1 2 3 F-1 F-2 F-3 To connector (F) on Control Unit. CONNECTOR (11) Open the door and block it open. (12) Discharge high voltage capacitor. (13) Disconnect the dummy resistor circuit from the sensor connector of control panel. (14) Carry out neces

ABSOLUTE HUMIDITY SENSOR CIRCUIT

the food is heated to generate moisture by which the resistance balance of the bridge circuit is deviated to increase the voltage available at AN6 terminal of the LSI. Then the LSI observes that voltage at AN6 terminal and compares it with its initial value, and when the comparison rate reaches the preset value (fixed for each menu to be cooked), the LSI causes the unit to stop sensor cooking; therea

Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts may

result in severe, possibly fatal, electric shock. (Example) High Voltage Capacitor, Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness etc.. WARNING: Avoid possible exposure to microwave energy. Please follow the instructions below before operating the oven. WARNING AGAINST HIGH VOL

15.Screw the oven lamp off from the lamp socket.

16.Remove the lamp socket from the lamp angle. 17.Pull the wire leads from the oven lamp socket by pushing the terminal hole of the oven lamp socket with a small flat type screw driver. 18.Now, the oven lamp socket is free. 19.Release the harness of the AH sensor assembly from three (3) wire holders of the hood duct. 20.Remove two (2) screws holding the AH sensor assembly to the hood

Figure S-1. Pictorial Diagram

HIGH VOLTAGE RECTIFIER HIGH VOLTAGE WIRE A HIGH VOLTAGE CAPACITOR HIGH VOLTAGE COMPONENTS POWER TRANSFORMER Power Supply cord 120V 60Hz 1 2 3 WHT GRN BLK WHT GRN BLK CAVITY THERMAL CUT-OUT MAGNETRON TEMPERATURE FUSE WHT RED BLK RED BLK FAN MOTOR TURNTABLE MOTOR GRY ORG WHT ORG ORG RED WHT ORG BLK WHT HOOD LAMPS & SOCKETS Blue Marking Blue Marking O

Figure S-2. Control Panel Circuit

+ – + – + – + – + – A 7 VRS1 (J1) D20 R110 R110 47 1/2w C110 0.033µ/250v C110 D25 D26 D27 D28 T1 D1 D1-D4 11ES1 Q20 KRA101M Q24 KRA101M R20 1k 1/2w RY4 RY5 RY1 RY2 NO NC RY3 Q25 KRA101M Q26 KRA101M Q28 KRA101M Q30 KRA101M Q27 KRC243M Q40 KRA101M MOTOR RUN CAPACITOR TURNTABLE MOTOR HOOD LAMP HOOD THERMO HOOD MOTOR COM(H) FAN MOTOR OVE

Sharp Microwave Oven Owners Instructions: