In the interest of user-safety the oven should be restored to its original
condition and only parts identical to those specified should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens con-
tain circuitry capable of producing very high voltage and
current, contact with following parts may result in a severe,
possibly fatal, electrical shock. (High Voltage Capacitor, High
Voltage Power Transformer, Magnetron, High Voltage Recti-
f
Sharp R-1490 PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE
ENERGY
(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3)
seal and sealing surfaces (arcing, wear, and o
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of pro-
ducing very high voltage and current, contact with
following parts may result in a severe, possibly
fatal, electrical shock.
(Example)
High Voltage Capacitor, High Voltage Power Trans-
former, Magnetron, High Voltage Rectifier Assem-
bly, High Voltage Harness etc..
Read the Service Manual carefully and follow all
instructions.
Before Servicing
1. Disconn
MICROWAVE MEASUREMENT PROCEDURE
A. Requirements:
1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven
should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition
by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external
surface of the oven.
2) Saf
Sharp R-1490 SHARP ELECTRONICS CORPORATION
SHARP PLAZA, MAHWAH,
NEW JERSEY 07430-2135
SERVICE MANUAL
OVER THE RANGE MICROWAVE OVEN
R-1490/ R-1491/1492
FOREWORD
This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information
for the SHARP OVER THE RANGE MICROWAVE OVEN, R-1490/ R-1491/ R1492.
The models R-1490, R-1491 and R-1492 is quite similar to base models R-1480/81/82 (Refer No. is S380
120 Volts / 14.3 Amperes
60 Hertz
Single phase, 3 wire grounded
Power Output
950 watts (IEC-705 TEST PROCEDURE)
Operating frequency of 2450MHz
Convection Power Output
1700 watts
Case Dimensions
Width 29-15/16"
Height 16-3/8"
Depth 15- 1/4" (Not including the door handle)
Cooking Cavity Dimensions
Width 20-1/4"
Height 8-3/16"
1.4 Cubic Feet
Depth 14-1/2"
Hood lamp
2 bulbs, 30W x 2, Incandescent l
The oven is equipped with a 3-prong grounding plug. DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE
GROUNDING PIN FROM THE PLUG.
The power supply cord and plug must be connected to a separate 120 Volt AC, 60 Hz, 15 Amp. or more branch circuit, using
a grounded receptacle. The receptacle should be located inside the cabinet directly above the Microwave Oven/Hood
system mounting location.
CONTROL PANEL
3-Prong
DESCRIPTION OF OPERATING SEQUENCE
SENSOR COOKING CONDITION
Using the INSTANT SENSOR function, the foods are cooked
or defrosted without figuring time, power level or quantity.
When the oven senses enough steam from the food, it
relays the information to its microprocessor which will calcu-
late the remaining cooking time and power level needed for
best results.
When the food is cooked, water vapor is developed. The
sensor �
NOTE: CONDITION OF OVEN
1.
DOOR CLOSED
2.
COOKING TIME PROGRAMMED
3.
VARIABLE COOKING CONTROL "HIGH"
4.
"START" PAD TOUCHED
Figure O-2. Oven Schematic-Cooking Condition
Figure O-1. Oven Schematic-Off Condition
SCHEMATIC
NOTE: CONDITION OF OVEN
1.
DOOR CLOSED
2.
CLOCK APPEARS ON DISPLAY
CAVITY
THERMAL CUT-OUT
MAGNETRON
TEMPERATURE FUSE
FUSE
20A
TURNTABLE
MOTOR
FAN
MOTOR
STIRRER
MOTOR
MAGNETRON
OVEN LAMP
MONITOR
SWITCH
BLK
W
Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected.
When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many
of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which
will be found in the "Test Procedure "section.
IMPORT
Sharp R-1490 KEY UNIT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable
is making good contact, verify that the door sensing switch (stop switch) operates properly; that is the
contacts are closed when
(1) Fill approximately 200 milliliters (7.2 oz) of tap water in a 1000 milliliter measuring cup.
(2) Place the container on the center of tray in the oven cavity.
(3) Close the door.
(4) Touch Reheat pad once and touch the Start pad, Now, the oven is in the sensor cooking condition
and “REHEAT” "SENSOR" and "COOK" will appear in the display.
(5) The oven will operate for the first
Sharp R-1490 Sensor Dummy Resistor Circuit
R1, R2 : 22Ω ± 1% 1/2W
R3 : 4.3kΩ ± 5% 1/4W
R4 : 1MΩ ± 5% 1/4W
Plunger
NC
NO
COM
COM
NO
NC
R3
R4
R1
R2
1
2
3
F-1
F-2
F-3
To connector (F)
on Control Unit.
CONNECTOR
(11) Open the door and block it open.
(12) Discharge high voltage capacitor.
(13) Disconnect the dummy resistor circuit from the sensor connector of control panel.
(14) Carry out neces
ABSOLUTE HUMIDITY SENSOR CIRCUIT
the food is heated to generate moisture by which the
resistance balance of the bridge circuit is deviated to
increase the voltage available at AN6 terminal of the LSI.
Then the LSI observes that voltage at AN6 terminal and
compares it with its initial value, and when the comparison
rate reaches the preset value (fixed for each menu to be
cooked), the LSI causes the unit to stop sensor cooking;
therea
Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts may
result in severe, possibly fatal, electric shock.
(Example)
High Voltage Capacitor, Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness etc..
WARNING: Avoid possible exposure to microwave energy. Please follow the instructions below before
operating the oven.
WARNING AGAINST HIGH VOL
15.Screw the oven lamp off from the lamp socket.
16.Remove the lamp socket from the lamp angle.
17.Pull the wire leads from the oven lamp socket by pushing
the terminal hole of the oven lamp socket with a small flat
type screw driver.
18.Now, the oven lamp socket is free.
19.Release the harness of the AH sensor assembly from
three (3) wire holders of the hood duct.
20.Remove two (2) screws holding the AH sensor assembly
to the hood
Figure S-1. Pictorial Diagram
HIGH
VOLTAGE
RECTIFIER
HIGH VOLTAGE
WIRE A
HIGH VOLTAGE
CAPACITOR
HIGH VOLTAGE COMPONENTS
POWER
TRANSFORMER
Power Supply
cord 120V 60Hz
1
2
3
WHT
GRN
BLK
WHT
GRN
BLK
CAVITY
THERMAL
CUT-OUT
MAGNETRON
TEMPERATURE
FUSE
WHT
RED
BLK
RED
BLK
FAN
MOTOR
TURNTABLE
MOTOR
GRY
ORG
WHT
ORG
ORG
RED
WHT
ORG
BLK
WHT
HOOD LAMPS
& SOCKETS
Blue
Marking
Blue Marking
O
Figure S-2. Control Panel Circuit
+
–
+
–
+
–
+
–
+
–
A 7
VRS1
(J1)
D20
R110
R110 47 1/2w
C110 0.033µ/250v
C110
D25
D26
D27
D28
T1
D1
D1-D4
11ES1
Q20
KRA101M
Q24
KRA101M
R20
1k 1/2w
RY4
RY5
RY1
RY2
NO
NC
RY3
Q25
KRA101M
Q26
KRA101M
Q28
KRA101M
Q30
KRA101M
Q27
KRC243M
Q40
KRA101M
MOTOR RUN
CAPACITOR
TURNTABLE
MOTOR
HOOD LAMP
HOOD THERMO
HOOD MOTOR
COM(H)
FAN MOTOR
OVE