Sharp R-1900M Operation Manual
Text of Sharp R-1900M Operation Manual
Sharp R-1900M COMMERCIAL MICROWAVE OVEN
OPERATION MANUAL
OPERATION MANUAL
This operation manual contains important information which you should read carefully
before using your microwave oven.
IMPORTANT:There may be a serious risk to health if this operation manual is not
followed or if the oven is modifi ed so that it operates with the door open.
R-1900M [EN].indd 1
R-1900M [EN].indd 1
9/29/08 1:36:29 PM
9/29/08 1:36:29 PM
Important Safety Instructions
2
Installation
2
Troubleshooting
4
Oven & Control Panel
6
Before Operation
7
How to Operate the Oven
7
Memory Operation
7
Memory Cooking
7
Cooking double/triple quantity with
memory
8
Express Defrost with Memory
9
Manual Operation
9
Time Cooking
9
Single Stage Cooking
9
Multi Stage Cooking
9
Repeat Cooking
10
Express Defrost
10
Program & Customize
11
Custom Setting
11
Saving Memories
17
Other Convenient Features
2
MPORTANT SAFETY INSTRUCTIONS
I
IMPORTANT: PLEASE READ CAREFULLY AND KEEP FOR FUTURE REFERENCE.
• The oven is for food preparation only.
Never operate when empty.
• Do not leave or store anything inside the oven when not in use.
• Never attempt to use the oven with the door open.
It is important not to tamper with the door safety latches.
This may result in exposure to microwave energy.
• Never operate the oven with any object caught in the door
s
1. Remove all packing materials. Remove the protective fi lm
(blue fi lm) from the outer case cabinet (if covered). Do not
remove the plastic fi lm from the inside of the oven window
as this protects it from dirt.
2. Place oven on a secure, level surface, strong enough to take
the oven weight, plus the heaviest item likely to be cooked in
the oven.
3. Ensure there is a minimum free space above the oven of
25 cm.
4. Do not place the oven
Should any of the error indicators appear in the display, follow the instructions:
EE Mode
Reason
Action Required
EE 1, EE 2
Failure of single magnetron
Call for service.★
EE 3
Both magnetrons failed
Call for service.
EE 4
Voltage too high
Call for service.
EE 5
Voltage too low
Call for service.
EE 7
Oven cavity or component
temperature too high
Check that nothing is blocking air intake openings on oven back or that
oven exterior is very hot
Should any of maintenance indicators appear in the display, follow the instruction:
CC Mode
Reason
Action required
CC1
CC2
Operation time of magnetrons exceeds
1,250 hours.
Call for service to replace the parts promptly. Failure to replace
parts that have exceeded recommended operation time may
cause failure of the microwave oven.
CC4
Operation time of the control unit, relays,
switches exceeds 200,000 times.
CC3
Operation time of exhaus
Sharp R-1900M 1. Touch control panels
2. Door latch openings
3. Ceramic shelf
4. Oven light
5. Air intake openings
6. Air intake fi lter
7. Door seals and sealing surfaces
8. Door hinges
9. Oven door with see-through window
10. Door latches
11. Door handle
12. Service window for replacing the oven light bulb
13. Ventilation openings
14. Power supply cord
15. Mounting plate
16. Screw for mounting plate
17. Splash cover
1. MANUAL/REPEAT pad
2. POWER
* Before operating your new oven, make sure you read and
understand this operation manual completely.
1) Plug in the oven.
* The digital display will show “ . “
2) Control panels can only be operated when the door is
closed.
3) Oven light will go on for 1 minute whenever the door is
opened or after cooking.
Cancellation:
1. Cooking data is canceled when keys are not pressed for
more than three minutes when setting programming.
2. Co
* Memory Cooking can be set in 6 operating ways.
There are multiple methods of selecting memories
depending on the input method selected and whether
or not Auto Start is turned on or off. To avoid mistakenly
selecting the incorrect memory, please confi rm your
settings by checking Custom Setting (see Custom Setting
1 and 2 on page 11).
<6 operating ways>
1. Dual Digit Input/Auto Start OFF (memory 00 - 99)
2. Dual Digit Input/Auto Start ON (memory 00 - 9
Sharp R-1900M Express Defrost with
Memory
* Suppose you want to cook with memory 0, which was
programmed for 10 minutes Express Defrost sequence,
Single Digit Input/Auto Start ON.
0
Procedure
1 Place food in oven.
Enter memory number.
Midway through the defrosting cycle, the CHECK
indicator will light in the display and an audible signal
will be heard unless signal volume has been set to Mute.
You may open the door, turn food over and shield any
warm portions. Clos
4 Press the POWER LEVEL pad.
Enter power level for 2nd stage.
5 Press the MANUAL/REPEAT pad.
Enter cooking time for 3rd
stage.
5
6 Press the START pad.
NOTES:
1. It is not necessary to press the POWER LEVEL pad for
100% at the last stage in Multi Stage Cooking.
2. If the Total Cooking Time is over the maximum time
allowed, error message, EE9 will be displayed. Press the
STOP/CLEAR pad to clear the error message pad and
reduce Total Cooking T
Sharp R-1900M You can check your oven settings and customize your oven
by changing Custom Setting settings.
The CUSTOM SETTING pad has 11 operations.
1. Selecting Memory Input Method
2. Selecting Auto Start Operation
3. Program Lock Setting
4. Audible Signal Sound Volume Setting
5. Cooking Completion Signal Setting
6. Memory Check
7. Counter Check/Clear
8. Air Intake Filter Counter
9. Selecting Operation in case of Magnetron Failure
10. Multi
* Suppose you want to set Program Lock ON.
x 2
Procedure
1 Press the Custom Setting pad
twice within 2 seconds.
2 Enter 3, 2 for Program Lock ON.
3 Press the START pad to save the
setting.
4 Press the STOP/CLEAR pad to
exit from the Custom Setting
Function.
NOTE : If you select Program Lock OFF, the LOCK indicator in
the display will disappear when you press the START pad.
Operation when Program Lock ON is set
KEY
Operation
Custom Setting Title
When Pro
2 Enter memory number.
(After entering the memory
number, the memory setting
of each content is shown for
1.5 seconds at 0.3 second
intervals until the STOP/
CLEAR pad is pressed.)
3 Press the STOP/CLEAR pad to
exit from the Custom Setting
Function.
NOTES:
1. If
CHECK
is displayed at step 2 the memory has not been
programmed.
2. Multiple memories can be checked until the STOP/
CLEAR pad is pressed to exit from the Custom Setting
Func
1. Only Dual Digit Input method can be used when inputting
memory numbers in Counter Check/Clear.
2. To clear total manual cooking usage, press the MANUAL/
REPEAT pad in Step 2 instead of the number pad.
3. To clear total Express Defrost usage, press the EXPRESS
DEFROST pad in Step 2 instead of the number pad.
4. To clear total usage, skip Step 2.
8. Air Intake Filter Counter
Use Custom Setting Function for Air Intake Filter Counter to
check tota
Air Filter Cycle
Air Filter Cycle can be changed from the factory setting of
100 hours to 001-999 hours
* Suppose you want to set the cycle to 250 hours.
2 Press the MANUAL/REPEAT pad.
3 Enter desired time.
(Ex : Enter 2, 5, 0 for 250 hours).
After about 1 sec.
CHECK
4 Press the START pad to save settings.
Procedure
Display
5 Press the STOP/CLEAR pad to exit from the
Custom Setting Function.
9. Selecting Operation in case of Magnetron Failure
Your oven
1. Only Dual Digit Input method can be used when inputting memory numbers in Multiplication Factor for Double/Triple
Quantity.
2. The multiplication factors can be set from 0.01 to 9.99 for
double quantity and triple quantity.
3. When you want to know the multiplication factor for triple
quantity, press the DOUBLE/TRIPLE QUANTITY twice at
step 1 after pressing the CUSTOM SETTING pad twice.
4. Multiplication Factors for Double/Triple Quantity ca
5 Press the MANUAL/
REPEAT pad and enter
desired multiplication
for A2 at Stage 2.
(Ex: Enter 1, 5 for 0.15.)
1
5
DEF.
DEF.
DEF.
6 Press the MANUAL/
REPEAT pad and enter
desired time for B2 at
Stage 2.
(Ex: Press 2 for
20 seconds.)
DEF.
DEF.
8 Press the MANUAL/
REPEAT pad and enter
the pause timing.
(Ex: Enter 7 for when 70%
of total defrosting time
has passed.)
7
DEF.
7 Press the POWER LEVEL
pad and enter desired
power level for PL2 at
Stage 2.