Sharp R-1900M Operation Manual

Text of Sharp R-1900M Operation Manual

Sharp R-1900M COMMERCIAL MICROWAVE OVEN

OPERATION MANUAL OPERATION MANUAL This operation manual contains important information which you should read carefully before using your microwave oven. IMPORTANT:There may be a serious risk to health if this operation manual is not followed or if the oven is modifi ed so that it operates with the door open. R-1900M [EN].indd 1 R-1900M [EN].indd 1 9/29/08 1:36:29 PM 9/29/08 1:36:29 PM

Important Safety Instructions

2 Installation 2 Troubleshooting 4 Oven & Control Panel 6 Before Operation 7 How to Operate the Oven 7 Memory Operation 7 Memory Cooking 7 Cooking double/triple quantity with memory 8 Express Defrost with Memory 9 Manual Operation 9 Time Cooking 9 Single Stage Cooking 9 Multi Stage Cooking 9 Repeat Cooking 10 Express Defrost 10 Program & Customize 11 Custom Setting 11 Saving Memories 17 Other Convenient Features 2

MPORTANT SAFETY INSTRUCTIONS

I IMPORTANT: PLEASE READ CAREFULLY AND KEEP FOR FUTURE REFERENCE. • The oven is for food preparation only. Never operate when empty. • Do not leave or store anything inside the oven when not in use. • Never attempt to use the oven with the door open. It is important not to tamper with the door safety latches. This may result in exposure to microwave energy. • Never operate the oven with any object caught in the door s

1. Remove all packing materials. Remove the protective fi lm

(blue fi lm) from the outer case cabinet (if covered). Do not remove the plastic fi lm from the inside of the oven window as this protects it from dirt. 2. Place oven on a secure, level surface, strong enough to take the oven weight, plus the heaviest item likely to be cooked in the oven. 3. Ensure there is a minimum free space above the oven of 25 cm. 4. Do not place the oven

Should any of the error indicators appear in the display, follow the instructions:

EE Mode Reason Action Required EE 1, EE 2 Failure of single magnetron Call for service.★ EE 3 Both magnetrons failed Call for service. EE 4 Voltage too high Call for service. EE 5 Voltage too low Call for service. EE 7 Oven cavity or component temperature too high Check that nothing is blocking air intake openings on oven back or that oven exterior is very hot

Should any of maintenance indicators appear in the display, follow the instruction:

CC Mode Reason Action required CC1 CC2 Operation time of magnetrons exceeds 1,250 hours. Call for service to replace the parts promptly. Failure to replace parts that have exceeded recommended operation time may cause failure of the microwave oven. CC4 Operation time of the control unit, relays, switches exceeds 200,000 times. CC3 Operation time of exhaus

Sharp R-1900M 1. Touch control panels

2. Door latch openings 3. Ceramic shelf 4. Oven light 5. Air intake openings 6. Air intake fi lter 7. Door seals and sealing surfaces 8. Door hinges 9. Oven door with see-through window 10. Door latches 11. Door handle 12. Service window for replacing the oven light bulb 13. Ventilation openings 14. Power supply cord 15. Mounting plate 16. Screw for mounting plate 17. Splash cover 1. MANUAL/REPEAT pad 2. POWER

* Before operating your new oven, make sure you read and

understand this operation manual completely. 1) Plug in the oven. * The digital display will show “ . “ 2) Control panels can only be operated when the door is closed. 3) Oven light will go on for 1 minute whenever the door is opened or after cooking. Cancellation: 1. Cooking data is canceled when keys are not pressed for more than three minutes when setting programming. 2. Co

* Memory Cooking can be set in 6 operating ways.

There are multiple methods of selecting memories depending on the input method selected and whether or not Auto Start is turned on or off. To avoid mistakenly selecting the incorrect memory, please confi rm your settings by checking Custom Setting (see Custom Setting 1 and 2 on page 11). <6 operating ways> 1. Dual Digit Input/Auto Start OFF (memory 00 - 99) 2. Dual Digit Input/Auto Start ON (memory 00 - 9

Sharp R-1900M Express Defrost with

Memory * Suppose you want to cook with memory 0, which was programmed for 10 minutes Express Defrost sequence, Single Digit Input/Auto Start ON. 0 Procedure 1 Place food in oven. Enter memory number. Midway through the defrosting cycle, the CHECK indicator will light in the display and an audible signal will be heard unless signal volume has been set to Mute. You may open the door, turn food over and shield any warm portions. Clos

4 Press the POWER LEVEL pad.

Enter power level for 2nd stage. 5 Press the MANUAL/REPEAT pad. Enter cooking time for 3rd stage. 5 6 Press the START pad. NOTES: 1. It is not necessary to press the POWER LEVEL pad for 100% at the last stage in Multi Stage Cooking. 2. If the Total Cooking Time is over the maximum time allowed, error message, EE9 will be displayed. Press the STOP/CLEAR pad to clear the error message pad and reduce Total Cooking T

Sharp R-1900M You can check your oven settings and customize your oven

by changing Custom Setting settings. The CUSTOM SETTING pad has 11 operations. 1. Selecting Memory Input Method 2. Selecting Auto Start Operation 3. Program Lock Setting 4. Audible Signal Sound Volume Setting 5. Cooking Completion Signal Setting 6. Memory Check 7. Counter Check/Clear 8. Air Intake Filter Counter 9. Selecting Operation in case of Magnetron Failure 10. Multi

* Suppose you want to set Program Lock ON.

x 2 Procedure 1 Press the Custom Setting pad twice within 2 seconds. 2 Enter 3, 2 for Program Lock ON. 3 Press the START pad to save the setting. 4 Press the STOP/CLEAR pad to exit from the Custom Setting Function. NOTE : If you select Program Lock OFF, the LOCK indicator in the display will disappear when you press the START pad. Operation when Program Lock ON is set KEY Operation Custom Setting Title When Pro

2 Enter memory number.

(After entering the memory number, the memory setting of each content is shown for 1.5 seconds at 0.3 second intervals until the STOP/ CLEAR pad is pressed.) 3 Press the STOP/CLEAR pad to exit from the Custom Setting Function. NOTES: 1. If CHECK is displayed at step 2 the memory has not been programmed. 2. Multiple memories can be checked until the STOP/ CLEAR pad is pressed to exit from the Custom Setting Func

1. Only Dual Digit Input method can be used when inputting

memory numbers in Counter Check/Clear. 2. To clear total manual cooking usage, press the MANUAL/ REPEAT pad in Step 2 instead of the number pad. 3. To clear total Express Defrost usage, press the EXPRESS DEFROST pad in Step 2 instead of the number pad. 4. To clear total usage, skip Step 2. 8. Air Intake Filter Counter Use Custom Setting Function for Air Intake Filter Counter to check tota

Air Filter Cycle

Air Filter Cycle can be changed from the factory setting of 100 hours to 001-999 hours * Suppose you want to set the cycle to 250 hours. 2 Press the MANUAL/REPEAT pad. 3 Enter desired time. (Ex : Enter 2, 5, 0 for 250 hours). After about 1 sec. CHECK 4 Press the START pad to save settings. Procedure Display 5 Press the STOP/CLEAR pad to exit from the Custom Setting Function. 9. Selecting Operation in case of Magnetron Failure Your oven
1. Only Dual Digit Input method can be used when inputting memory numbers in Multiplication Factor for Double/Triple Quantity. 2. The multiplication factors can be set from 0.01 to 9.99 for double quantity and triple quantity. 3. When you want to know the multiplication factor for triple quantity, press the DOUBLE/TRIPLE QUANTITY twice at step 1 after pressing the CUSTOM SETTING pad twice. 4. Multiplication Factors for Double/Triple Quantity ca

5 Press the MANUAL/

REPEAT pad and enter desired multiplication for A2 at Stage 2. (Ex: Enter 1, 5 for 0.15.) 1 5 DEF. DEF. DEF. 6 Press the MANUAL/ REPEAT pad and enter desired time for B2 at Stage 2. (Ex: Press 2 for 20 seconds.) DEF. DEF. 8 Press the MANUAL/ REPEAT pad and enter the pause timing. (Ex: Enter 7 for when 70% of total defrosting time has passed.) 7 DEF. 7 Press the POWER LEVEL pad and enter desired power level for PL2 at Stage 2.

Sharp Microwave Oven Owners Instructions: