Sharp R-210D Service Manual
Text of Sharp R-210D Service Manual
In interests of user-safety the oven should be restored to its original
condition and only parts identical to those specified should be used.
MODEL
R-210D
S5001R210DPJ/
MICROWAVE OVEN
TABLE OF CONTENTS
CAUTION, MICROWAVE RADIATION................................................................................................................. 1
WARNING ..................................................................................................
GENERAL IMPORTANT INFORMATION
This Manual has been prepared to provide Sharp Corp. Service
engineers with Operation and Service Information.
It is recommended that service engineers carefully study the
entire text of this manual, so they will be qualified to render
satisfactory customer service.
CAUTION
MICROWAVE RADIATION
DO NOT BECOME EXPOSED TO RADIATION FROM
THE MICROWAVE GENE
THIS APPLIANCE MUST BE EARTHED
IMPORTANT
THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
GREEN-AND-YELLOW
: EARTH
BLUE
: NEUTRAL
BROWN
: LIVE
ITEM
DESCRIPTION
Power Requirements
230 - 240 Volts
50 Hertz
Single phase, 3 wire earthed
Power Consumption
1.16 kW
Power Output
800 watts nominal of RF microwave energy (IEC Test Procedure)
Operating frequency 2450 MHz
Case Dimensions
Width 460 m
8. Control panel
9. Waveguide cover
10. Power supply cord
11. Turntable
12. Roller stay
1. Ventilation openings
2. Oven lamp
3. Door hinges
4. Door safety latches
5. See through door
6. Door seals sealing surfaces
MED
MED LOW
DEFROST
LOW
MED HIGH
HIGH
0
1
2
3
456
7
8
9
10
11
12
13
14
15
20
25
30
1.0
0.5
DEFROST(kg)
DINNER PLATE
REHEAT 1 SERVE (400g)
SOUP
DEFROST
FRESH VEGETABLES
MED
7-8min.
REHEAT 1 c
Closing the door activates all door interlock switches
(1st. latch switch, 2nd. latch switch and stop switch).
IMPORTANT
When the oven door is closed, the monitor switch contacts
(COM-NC) must be open.
When the microwave oven is plugged in a wall outlet, rated
voltage is supplied to the noise filter and the control unit.
Figure O-1 on page 25
MICROWAVE COOKING CONDITION
HIGH COOKING
Select the power level HIGH by p
Sharp R-210D FUNCTION OF IMPORTANT COMPONENTS
Figure D-1. Door Open Mechanism
1ST. LATCH SWITCH, 2ND. LATCH SWITCH AND
STOP SWITCH
1. When the oven door is closed, the contacts (COM-NO)
must be closed.
2. When the oven door is opened, the contacts (COM-
NO) must be opened.
MONITOR SWITCH
1. When the oven door is closed, the contacts (COM-NC)
must be opened.
2. When the oven door is opened, the contacts (COM-
NC) must be closed.
3. If the oven door is opened a
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of producing very high voltage and current, contact with any part of the
high voltage circuit will result in electrocution. High voltage capacitor, Power transformer, Magnetron, High voltage
rectifier assembly, High voltage harness.
REMEMBER TO CHECK 3D
1) Disconnect the supply.
2) Door opened, and wedged open.
3) Discharge the high voltage capacitor.
WARNING: AGAIN
Sharp R-210D H.V. RECTIFIER ASSEMBLY
HIGH VOLTAGE WIRE
HIGH VOLTAGE CAPACITOR
1ST. LATCH SWITCH
2ND. LATCH SWITCH
STOP SWITCH
MONITOR SWITCH
MONITOR RESISTOR
THERMAL CUT-OUT 125˚C (OVEN)
THERMAL CUT-OUT 95˚C (MG)
FAN MOTOR
TURNTABLE MOTOR
FUSE M8A
CONTROL PANEL
RELAY (RY-1, RY-2)
FOIL PATERN ON P.W.B.
POWER SUPPLY CORD
SHORTED WIRE HARNESS
OPENED WIRE HARNESS
OVEN LAMP OR SOCKET
WALL OUTLET
MISADJUSTMENT SWITCH
HOME FUSE OR BREAKE
CARRY OUT 3D CHECKS.
Isolate the magnetron from the high voltage circuit by removing all leads connected to the filament
terminal.
To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron
filament terminals, the meter should show a reading of less than 1 ohm.
To test for a short circuit filament to anode condition, connect ohmmeter between one of the filament
terminals and the case of the magnetron (grou
Heat up for 54 sec.
B
POWER TRANSFORMER TEST
CARRY OUT 3D CHECKS.
Disconnect the leads to the primary winding of the power transformer. Disconnect the filament and
secondary winding connections from the rest of the HV circuitry. Using an ohmmeter, set on a low
range, it is possible to check the continuity of all three windings. The following readings should be
obtained:
WARNING: High voltages and large currents are p
Sharp R-210D HIGH VOLTAGE CAPACITOR TEST
CARRY OUT 3D CHECKS.
A. Isolate the high voltage capacitor from the circuit.
B. Continuity check must be carried out with measuring instrument which is set to the highest
resistance range.
C. A normal capacitor shows continuity for a short time (kick) and then a resistance of about 10MΩ
after it has been charged.
D. A short-circuited capacitor shows continuity all the
to resistricted ventilation, cooling fan failure or a fault condition within the magnetron or HV circuit.
An open circuit temperature fuse (OVEN) indicates that the food in the oven cavity may catch fire, this
may be due to overheating produced by improper setting of the cooking time or failure of the control
panel.
H
MOTOR WINDING TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the motor. Using
CONTROL PANEL ASSEMBLY TEST
The control panel consists of circuits including semiconductors such as LSI, ICs, etc. Therefore,
unlike conventional microwave ovens, proper maintenance can not be performed with only a
voltmeter and ohmmeter.
In this service manual, troubleshooting by replacement is described according to the symptoms
indicated.
1. Control Panel
The following symptoms indicate a defec
PROCEDURES TO BE TAKEN WHEN THE FOIL PATTERN ON THE PRINTED WIRING
BOARD(PWB) IS OPEN
To protect the electronic circuits, this model is provided with a fine foil pattern added to the input circuit
on the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide
given below for repair.
Problem: POWER ON, indicator does not light up.
CARRY OUT 3D CHECKS.
ST
CONTROL PANEL ASSEMBLY
OUTLINE OF CONTROL PANEL
5) Buzzer Circuit
The buzzer is responsive to signals from the LSI to emit
audible sounds (tact switch touch sound and comple-
tion sound).
6) Door Sensing Switch (Stop Switch)
A switch to "tell" the LSI if the door is open or closed.
7) Relay Circuit
To drive the magnetron, fan motor, turntable motor and
light the oven lamp.
8) Encoder
The encoder generates the pulse signal, and the pulse
signal is
Sharp R-210D DESCRIPTION OF LSI
LSI(IXA023DR)
The I/O signal of the LSI(IXA023DR) are detailed in the following table.
Pin No.
Signal
I/O
Description
1
D3
OUT
Segment data signal.
Signal is input to the cathodes of the light-emitting diodes (LD8, LD16 and LD24).
2
D4
OUT
Signal to sound buzzer.
A: Tact switch touch sound.
B: Completion sound.
3
D5
OUT
Oven lamp, turntable motor and fan motor driving signal(Square Waveform
: 50Hz).
To turn on and off shut-off
Signal to synchronize LSI with commercial power source frequency.
This is basic timing for all real time process-
ing of LSI.
18-19
AIN0-AIN1
IN
Terminal to change functions according to the model.
Signal in accordance with the model in operation is applied to set up its function.
20
AIN2
IN
Input signal which communicates the door open/close information to LSI.
Door closed; "H" level signal.
Door opened;
1. Precautions for Handling Electronic Components
This unit uses CMOS LSI in the integral part of the
circuits. When handling these parts, the following pre-
cautions should be strictly followed. CMOS LSI have
extremely high impedance at its input and output
terminals. For this reason, it is easily influenced by the
surrounding high voltage power source, static electric-
ity charge in clothes, etc., and sometimes it is not fully
protected by the
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE
WARNING:
Avoid possible exposure to microwave energy. Please follow the instructions
below before operating the oven.
1. Disconnect oven from power supply.
2. Visually check the door and cavity face plate for dam-
age (dents, cracks, signs of arcing etc.).
Carry out any remedial work that is necessary before
operating the oven.
Do not operate the oven if any of the following conditions
exist;
1. Door