Sharp R-220DW Service Manual

Text of Sharp R-220DW Service Manual

Sharp R-220DW In the interest of user-safety the oven should be restored to its original

condition and only parts identical to those specified should be used. WARNING TO SERVICE PERSONNEL: Microwave ovens con- tain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor, High Voltage Power Transformer, Magnetron, Hig

PRECAUTIONS TO BE OBSERVED BEFORE AND

DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY (a) Do not operate or allow the oven to be operated with the door open. (b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, an

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of pro- ducing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (Example) High Voltage Capacitor, High Voltage Power Trans- former, Magnetron, High Voltage Rectifier Assem- bly, High Voltage Harness etc.. Read the Service Manual carefully and follow all instructions. Before Servicing 1. Disc

MICROWAVE MEASUREMENT PROCEDURE

A. Requirements: 1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external surface of the oven. 2)

SHARP ELECTRONICS CORPORATION

SHARP PLAZA, MAHWAH, NEW JERSEY 07430-2135 SERVICE MANUAL MICROWAVE OVEN R-220DW/ R-230DK/ R-230DW FOREWORD This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP MICROWAVE OVEN, R-220DW, R-230DK, R-230DW. It is recommended that service personnel carefully study the entire text of this manual so that they will be qualifi

This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed

and grounded in accordance with the National Electrical Code and local codes and ordinances. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. WARNING: Improper use of the

The electrical requirements are a 115 -120 volt 60 Hz, AC only,

15 or 20 amp. fused electrical supply. It is recommended that a separate circuit serving only this appliance be provided. When installing this appliance, observe all applicable codes and ordinances. A short power-supply cord is provided to reduce risks of becoming entangled in or tripping over a longer cord. Where a two-pronged wall-receptacle

Sharp R-220DW DESCRIPTION OF OPERATING SEQUENCE

The following is a description of component functions during oven operation. OFF CONDITION Closing the door activates door sensing switch and second- ary interlock switch. (In this condition, the monitor switch contacts are opened.) When oven is plugged in, 120 volts A.C. is supplied to the control unit. (Figure O-1). 1. The display will show flashing "88:88". To set any program or set t

Figure O-1. Oven Schematic-Off Condition

SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED 2. CLOCK APPEARS ON DISPLAY SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED 2. COOKING TIME PROGRAMMED 3. VARIABLE COOKING CONTROL "HIGH" 4. "START" PAD TOUCHED Figure O-2. Oven Schematic-Cooking Condition POWER TRANSFORMER RECTIFIER MAGNETRON CAPACITOR 0.86µF C/T FUSE 120V AC 60 Hz OVEN LAMP TURN- TABLE MOTOR FAN MOTOR MONITOR SWITCH SECON

DESCRIPTION AND FUNCTION OF COMPONENTS

DOOR OPEN MECHANISM The door is opened by pulling the door, refer to the Figure D-1. Figure D-1. Door Open Mechanism DOOR SENSING AND SECONDARY INTERLOCK SWITCHES The secondary interlock switch is mounted in the lower position of the latch hook and the door sensing switch in the primary interlock system is mounted in the upper position of the latch hook. They are activated by the latch heads

Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected.

When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the "Test Procedure "section. IMP

MAGNETRON ASSEMBLY TEST

1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. To test for an open filament, isolate the magnetron from the high voltage circuit. A continuity check across the magnetron filament leads should indicate less than 1 ohm. CK = Check / RE = Replace TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST RE CK A B C D E F F G

POWER TRANSFORMER TEST

1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Disconnect the primary input terminals and measure the resistance of the transformer with an ohmmeter. Check for continuity of the coils with an ohmmeter. On the R x 1 scale, the resistance of the primary coil should be less than 1 ohm and the resistance of the high

Sharp R-220DW 1. Disconnect the power supply cord, and then remove outer case.

2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the capacitor is open, no high voltage will be available to the magnetron. Disconnect input leads and check for short or open between the terminals using an ohmmeter. Checking with a high ohm scale, if the high voltage capacitor is normal, t
1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Before performing this test, make sure that the secondary interlock switch and the primary interlock relay are operating properly, according to the above Switch Test Procedure. Disconnect the wire lead from the monitor switch (COM) terminal. Ch

BLOWN C/T FUSE TEST

TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the C/T fuse is blown when the door is opened, check the primary interlock relay, secondary interlock switch and monitor switch according to the "TEST PROCEDURE" for those switches before replacing the blown C/T fuse. C

2) Open the door and block it open.

3) Discharge high voltage capacitor. 4) Replace the key unit. 5) Reconnect all leads removed from components during testing. 6) Re-install the outer case (cabinet). 7) Reconnect the power supply cord after the outer case is installed. 8) Run the oven and check all functions. 2. Control Unit. The following symptoms indicate a defective control unit. Before replacing the control unit, perform t

(1) Place one cup of water in the center of the turntable tray in the oven cavity.

(2) Close the door, touch the " EXPRESS DEFROST " pad once. (3) The oven is in Express Defrost cooking condition. (4) The oven will operate as follows. WEIGHT 1ST STAGE 2ND STAGE 3RD STAGE 4TH STAGE LEVEL TIME LEVEL TIME LEVEL TIME LEVEL TIME 0.5lb 70% 57sec. 0% 57sec. 50% 32sec. 30% 45sec. (5) If improper operation is indicated, the control unit i

To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on

the PWB, this foil pattern acts as a fuse. 1. Foil pattern check and repairs. 1) Disconnect the power supply cord and then remove outer case. 2) Open the door and block it open. 3) Discharge high voltage capacitor. 4) Follow the troubleshooting guide given below for repair. ST

Sharp R-220DW The touch control section consists of the following units as

shown in the touch control panel circuit. (1) Key Unit (2) Control Unit The principal functions of these units and their related signals are explained below. Key Unit The key unit is composed of a matrix, signals generated in the LSI are sent to the key unit through R00, R01, R03, R20 and R21. When a key pad is touched, a signal is completed through the key unit and pas

Sharp Microwave Oven Owners Instructions: