Sharp R-24AT Service Manual
Text of Sharp R-24AT Service Manual
TABLE OF CONTENTS
Page
SERVICING ................................................................................................................. INSIDE FRONT COVER
CAUTION, MICROWAVE RADIATION............................................................................................................ 1
WARNING.....................................................................................................................................
REMEMBER TO CHECK 3D
1) Disconnect the supply.
2) Door opened, and wedged open.
3) Discharge high two voltage capacitors.
WARNING: AGAINST THE CHARGE OF THE TWO
HIGH-VOLTAGE CAPACITORS.
The two high-voltage capacitors remain charged
about 60 seconds after the oven has been switched
off. Wait for 60 seconds and then short-circuit the
connection of the two high-voltage capacitors (that
is, of the connecting lead of the high-voltage recti-
fier)
GENERAL IMPORTANT INFORMATION
This Manual has been prepared to provide Sharp Corp. Service
engineers with Operation and Service Information.
It is recommended that service engineers carefully study the
entire text of this manual, so they will be qualified to render
satisfactory customer service.
CAUTION
MICROWAVE RADIATION
DO NOT BECOME EXPOSED TO RADIATION FROM
THE MICROWAVE GENERATOR
THIS APPLIANCE MUST BE EARTHED
IMPORTANT
THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
GREEN-AND-YELLOW
: EARTH
BLUE
: NEUTRAL
BROWN
: LIVE
PRODUCT DESCRIPTION
SPECIFICATION
ITEM
DESCRIPTION
Power Requirements
230 - 240 Volts
50 Hertz
Single phase, 3 wire earthed
Power Comsumption
2.4 kW Approx. 11 A [R-22AT] / 2.9 kW Approx. 13 A [R-24AT]
Power Output
1500 W [R-22AT]/ 1900 W [R
Hole for safety door latches
3.
Ceramic floor
4.
Splash cover
5.
Oven light
6.
Air intake filter
7.
Air intake openings
8.
Oven cavity
9.
Door seals and sealing surfaces
10. Door hinges
11. Oven door with see-through window
12. Door safety latches
13. Door handle.
14. Outer cabinet
15. Removable cover over oven light bulb
16. Air vent openings
17. Power supply cord
18 Mounting plate
19 Screw for mou
Sharp R-24AT to negative voltage of approximately 4000 volts D.C..
3. The 2450 MHz microwave energy produced in the
magnetron generates a wave length of 12.24 cm. This
energy is channelled through the waveguide (transport
channel) into the oven cavity, where the food is placed
to be cooked.
4. When the cooking time is up, a signal tone is heard and
the relays RY3+RY4 go back to their home position.
The circuits to the high voltage tra
Sharp R-24AT NOTE: The ON/OFF time ratio does not exactly corre-
spond to the percentage of microwave power,
because approx. 3 seconds are needed for heat-
ing up the magnetron filament.
TWO MAGNETRON OPERATION SYSTEM
Two magnetrons MG1+MG2 are equipped in order to get
higher microwave power output. The primary windings of
the high voltage transformers T1+T2 are connected so
that each magnetron can be oscillated alternatively ac-
cording to the frequenc
Sharp R-24AT DOOR OPEN MECHANISM
1. The door release lever is pulled.
2. The upper latch head is lifted up by the linked door
release lever.
3. The head lever is lifted up by the door release lever.
4. The joint lever is lifted up by the head lever.
5. The lower latch head is lifted up by the joint lever.
6. Now both latch heads are lifted up, so they can be
released from the latch hook.
7. Now the door can be opened.
Figure D-1. Door Open Mechanism
INT
EXHAUST OVEN THERMISTOR TH3
The thermistor is a negative temperature coefficient type.
The temperature in the exhaust duct is detected through
the resistance of the thermistor.
If the temperature is high, the control panel will display
“EE7” and the oven will stop to avoid overheating and
catching fire.
If the thermistor is open, the control panel will display
"EE6" and the oven will stop.
MAGNETRON THERMISTORS TH1, TH2
The thermistor i
“ . “ does not appear on display when power cord is plugged into
wall outlet.
Control panel can not accept key in.
Fuse F1 or F2 blows when the door is opened.
Home fuse blows when power cord is plugged into wall outlet.
Weak point F3 blows when power cord is plugged into wall outlet.
Oven lamp, fan motor and antenna motors do not work for 1
minute when the door is opened or after cooking.
Fuse F1 or F2 blows when power cord is plugge
CARRY OUT 3D CHECKS.
Isolate the magnetron from high voltage circuit by removing all leads connected to filament terminal.
To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron
filament terminals, the meter should show a reading of less than 1 ohm.
To test for short circuit filament to anode condition, connect ohmmeter between one
Room temperature ................................................................................................. T0 = 21°C
Initial temperature .................................................................................................. T1 = 11°C
Temperature after (28 + 3) = 31 sec [for R-22AT].................................................. T2 = 21°C
Temperature after (22 + 3) = 25 sec [for R-24AT].............................
HIGH VOLTAGE TRANSFORMER TEST
WARNING:
High voltage and large currents are present at the secondary winding and
filament winding of the high voltage transformer. It is very dangerous to work
near this part when the oven is on. NEVER make any voltage measurements
of the high-voltage circuits, including the magnetron filament.
CARRY OUT 3D CHECKS.
Disconnect the leads to the primary winding
3. CARRY OUT 4R CHECKS.
CAUTION: IF THE temperature fuse INDICATES AN OPEN CIRCUIT AT ROOM TEMPERATURE,
REPLACE temperature fuse.
I
THERMISTOR TH1, TH2, TH3 TEST
Open
Close
Display or
temperature
temperature
Condition
Check point
Magnetron tem-
perature fuse (Up-
per) TF1
Magnetron tem-
p e r a t u r e f u s e
(Lower) TF2
Exhaust tempera-
ture fuse TF3
150˚C
120˚C
Non resetable
type
Non resetable
type
EE1
EE3
EE2
Oven shut
off
Magnetron
If the meter does not indicate above resistance, replace the thermistor.
3. CARRY OUT 4R CHECKS.
J
MOTOR WINDING TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the motor. Using an ohmmeter, check the resistance between the two
terminals.
Resistance of Blower motor should be approximately 60Ω.
Resistance of Antenna motor should be approximately 8.8 kΩ.
If incorrect readings are obtain
PROCEDURES TO BE TAKEN WHEN THE FUSE ON THE PRINTED WIRING BOARD(PWB) IS
OPEN
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
f) A certain group of indicators do not light up.
g) The figure of all digits flicker.
2-3 Other possible problems caused by defective control unit.
a) Buzzer does not sound or continues to sound.
b) Cooking is not possible.
CARRY OUT 3D CHECKS.
If the display fails to clear when the STOP/CLEAR pad is depressed, f