Sharp R-231F Service Manual

Text of Sharp R-231F Service Manual

In interests of user-safety the oven should be restored to its original

condition and only parts identical to those specified should be used. MODEL R-231F S1201R231FPJ/ MICROWAVE OVEN TABLE OF CONTENTS Page CAUTION, MICROWAVE RADIATION............................................................................................................. 1 WARNING................................................................................................

GENERAL IMPORTANT INFORMATION

This Manual has been prepared to provide Sharp Corp. Service engineers with Operation and Service Information. It is recommended that service engineers carefully study the entire text of this manual, so they will be qualified to render satisfactory customer service. CAUTION MICROWAVE RADIATION DO NOT BECOME EXPOSED TO RADIATION FROM THE MICROWAVE GENE

THIS APPLIANCE MUST BE EARTHED

IMPORTANT THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE: GREEN-AND-YELLOW : EARTH BLUE : NEUTRAL BROWN : LIVE ITEM DESCRIPTION Power Requirements 230 - 240 Volts 50 Hertz Single phase, 3 wire earthed Power Consumption 1.21 kW Power Output 800 watts nominal of RF microwave energy (IEC Test Procedure) Operating frequency 2450 MHz Case Dimensions Width 460 m

TOUCH CONTROL PANEL

OVEN 6. Door seals sealing surfaces 7. Coupling 8. Control panel 9. Liquid crystal display 10. Waveguide cover 1. Door open button 2. Oven lamp 3. Door hinges 4. Door safety latches 5. See through door 11. Power supply cord 12. Ventilation openings 13. Turntable 14. Roller stay 1. INSTANT ACTION PADS Press to cook or reheat 6 popular menus. 2. EXPRESS DEFROST PAD Press to select the Express Defrost menu. 3. EASY

Sharp R-231F Closing the door activates all door interlock switches

(1st. latch switch, 2nd. interlock relay control switch). IMPORTANT When the oven door is closed, the monitor switch contacts (COM-NC) must be open. When the microwave oven is plugged in a wall outlet, rated voltage is supplied to the noise filter and the control unit. Figure O-1 on page 25 1. The display flashes "88:88". 2. To set any programmes or set the clo

FUNCTION OF IMPORTANT COMPONENTS

TEMPERATURE FUSE The temperature fuse, located on the top of the oven cavity, is designed to prevent damage to the oven by fire. If the food load is overcooked, by either error in cook time or defect in the control unit, the temperature fuse will open. Under normal operation, the temperature fuse remains closed. However, when abnormally high temperatures are reached within the oven cavity, the temperature fuse will

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of producing very high voltage and current, contact with any part of the high voltage circuit will result in electrocution. High voltage capacitor, Power transformer, Magnetron, High voltage rectifier assembly, High voltage fuse, High voltage harness. REMEMBER TO CHECK 3D 1) Disconnect the supply. 2) Door opened, and wedged open. 3) Discharge the high voltage capaci

CK = Check / RE = Replace

MAGNETRON POWER TRANSFORMER H.V. RECTIFIER ASSEMBLY HIGH VOLTAGE WIRE HIGH VOLTAGE CAPACITOR 1ST. LATCH SWITCH 2ND. INTERLOCK RELAY CONTROL SWITCH MONITOR SWITCH TEMPERATURE FUSE (OVEN) FAN MOTOR TURNTABLE MOTOR FUSE T6.3A TOUCH CONTROL PANEL RELAY (RY-1, RY-2) FOIL PATERN ON P.W.B. POWER SUPPLY CORD SHORTED WIRE HARNESS OPENED WIRE HARNESS OVEN LAMP WALL OUTLET MISADJUSTMENT SWITCH HOME FUSE OR BREAKER BLOCKED COOLING FA

CARRY OUT 3D CHECKS.

Isolate the magnetron from the high voltage circuit by removing all leads connected to the filament terminal. To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron filament terminals, the meter should show a reading of less than 1 ohm. To test for a short circuit filament to anode condition, connect ohmmeter between one of the filament terminals and the case of the magnetron (grou

Heat up for 55 sec.

B POWER TRANSFORMER TEST CARRY OUT 3D CHECKS. Disconnect the leads to the primary winding of the power transformer. Disconnect the filament and secondary winding connections from the rest of the HV circuitry. Using an ohmmeter, set on a low range, it is possible to check the continuity of all three windings. The following readings should be obtained: WARNING: High voltages and large currents are present at the secondary windin

Sharp R-231F HIGH VOLTAGE CAPACITOR TEST

CARRY OUT 3D CHECKS. A. Isolate the high voltage capacitor from the circuit. B. Continuity check must be carried out with measuring instrument which is set to the highest resistance range. C. A normal capacitor shows continuity for a short time (kick) and then a resistance of about 10MΩ after it has been charged. D. A short-circuited capacitor shows continuity all the
CARRY OUT 3D CHECKS. If the fuse T6.3A is blown when the door is opened, check the 1st latch switch, 2nd. interlock relay control switch, monitor switch and 2nd. interlock relay RY2. If the fuse T6.3A is blown by incorrect door switching, replace the defective switch(es) and the fuse T6.3A. If the fuse T6.3A is blown, there is a shorts or grounds in electrical parts or wire harness. Che

2-1 Programming problems.

a) When touching the pads, a certain group of pads do not produce a signal. b) When touching the pads, no pads produce a signal. 2-2 Display problems. a) For a certain digit, all or some segments do not light up. b) For a certain digit, brightness is low. c) Only one indicator does not light up. d) The corresponding segments of all digits do not light up; or they continue

To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary

on the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide given below for repair. Problem: POWER ON, indicator does not light up. CARRY OUT 3D CHECKS. STEPS OCCURRENCE CAUSE OR CORRECTION The rated voltage is not applied between Pin 1 No. 3 of the 2 pin connector (A) and the Check supply voltag

Sharp R-231F The touch control section consists of the following units as

shown in the touch control panel circuit. (1) Key Unit (2) Control Unit The principal functions of these units and their related signals are explained below. Key Unit The key unit is composed of a matrix, signals generated in the LSI are sent to the key unit through R00, R01, R02, R03, R20 and R21. When a key pad is touched, a signal is completed through the key unit and passed back to

DESCRIPTION OF LSI

The I/O signal of the LSI are detailed in the following table. Pin No. Signal I/O Description 1 RESET IN Auto clear terminal. Signal is input to reset the LSI to the initial state when power is supplied. Temporarily set to “L” level the moment power is supplied, at this time the LSI is reset. Thereafter set at “H” level. 2 TEST IN Connected to GND. 3 VSS IN Power source voltage: -5V. VSS voltage of power source circuit

Sharp Microwave Oven Owners Instructions: