Sharp R-231F Service Manual
Text of Sharp R-231F Service Manual
In interests of user-safety the oven should be restored to its original
condition and only parts identical to those specified should be used.
MODEL
R-231F
S1201R231FPJ/
MICROWAVE OVEN
TABLE OF CONTENTS
Page
CAUTION, MICROWAVE RADIATION............................................................................................................. 1
WARNING................................................................................................
GENERAL IMPORTANT INFORMATION
This Manual has been prepared to provide Sharp Corp. Service
engineers with Operation and Service Information.
It is recommended that service engineers carefully study the
entire text of this manual, so they will be qualified to render
satisfactory customer service.
CAUTION
MICROWAVE RADIATION
DO NOT BECOME EXPOSED TO RADIATION FROM
THE MICROWAVE GENE
THIS APPLIANCE MUST BE EARTHED
IMPORTANT
THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
GREEN-AND-YELLOW
: EARTH
BLUE
: NEUTRAL
BROWN
: LIVE
ITEM
DESCRIPTION
Power Requirements
230 - 240 Volts
50 Hertz
Single phase, 3 wire earthed
Power Consumption
1.21 kW
Power Output
800 watts nominal of RF microwave energy (IEC Test Procedure)
Operating frequency 2450 MHz
Case Dimensions
Width 460 m
TOUCH CONTROL PANEL
OVEN
6. Door seals sealing surfaces
7. Coupling
8. Control panel
9. Liquid crystal display
10. Waveguide cover
1. Door open button
2. Oven lamp
3. Door hinges
4. Door safety latches
5. See through door
11. Power supply cord
12. Ventilation openings
13. Turntable
14. Roller stay
1. INSTANT ACTION PADS
Press to cook or reheat 6 popular menus.
2. EXPRESS DEFROST PAD
Press to select the Express Defrost menu.
3. EASY
Sharp R-231F Closing the door activates all door interlock switches
(1st. latch switch, 2nd. interlock relay control switch).
IMPORTANT
When the oven door is closed, the monitor switch contacts
(COM-NC) must be open.
When the microwave oven is plugged in a wall outlet, rated
voltage is supplied to the noise filter and the control unit.
Figure O-1 on page 25
1. The display flashes "88:88".
2. To set any programmes or set the clo
FUNCTION OF IMPORTANT COMPONENTS
TEMPERATURE FUSE
The temperature fuse, located on the top of the oven
cavity, is designed to prevent damage to the oven by fire.
If the food load is overcooked, by either error in cook time
or defect in the control unit, the temperature fuse will open.
Under normal operation, the temperature fuse remains
closed. However, when abnormally high temperatures are
reached within the oven cavity, the temperature fuse will
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of producing very high voltage and current, contact with any part of the
high voltage circuit will result in electrocution. High voltage capacitor, Power transformer, Magnetron, High voltage
rectifier assembly, High voltage fuse, High voltage harness.
REMEMBER TO CHECK 3D
1) Disconnect the supply.
2) Door opened, and wedged open.
3) Discharge the high voltage capaci
CK = Check / RE = Replace
MAGNETRON
POWER TRANSFORMER
H.V. RECTIFIER ASSEMBLY
HIGH VOLTAGE WIRE
HIGH VOLTAGE CAPACITOR
1ST. LATCH SWITCH
2ND. INTERLOCK RELAY CONTROL
SWITCH
MONITOR SWITCH
TEMPERATURE FUSE (OVEN)
FAN MOTOR
TURNTABLE MOTOR
FUSE T6.3A
TOUCH CONTROL PANEL
RELAY (RY-1, RY-2)
FOIL PATERN ON P.W.B.
POWER SUPPLY CORD
SHORTED WIRE HARNESS
OPENED WIRE HARNESS
OVEN LAMP
WALL OUTLET
MISADJUSTMENT SWITCH
HOME FUSE OR BREAKER
BLOCKED COOLING FA
CARRY OUT 3D CHECKS.
Isolate the magnetron from the high voltage circuit by removing all leads connected to the filament
terminal.
To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron
filament terminals, the meter should show a reading of less than 1 ohm.
To test for a short circuit filament to anode condition, connect ohmmeter between one of the filament
terminals and the case of the magnetron (grou
Heat up for 55 sec.
B
POWER TRANSFORMER TEST
CARRY OUT 3D CHECKS.
Disconnect the leads to the primary winding of the power transformer. Disconnect the filament and
secondary winding connections from the rest of the HV circuitry. Using an ohmmeter, set on a low
range, it is possible to check the continuity of all three windings. The following readings should be
obtained:
WARNING: High voltages and large currents are present at the secondary windin
Sharp R-231F HIGH VOLTAGE CAPACITOR TEST
CARRY OUT 3D CHECKS.
A. Isolate the high voltage capacitor from the circuit.
B. Continuity check must be carried out with measuring instrument which is set to the highest
resistance range.
C. A normal capacitor shows continuity for a short time (kick) and then a resistance of about 10MΩ
after it has been charged.
D. A short-circuited capacitor shows continuity all the
CARRY OUT 3D CHECKS. If the fuse T6.3A is blown when the door is opened, check the 1st latch switch, 2nd. interlock relay
control switch, monitor switch and 2nd. interlock relay RY2.
If the fuse T6.3A is blown by incorrect door switching, replace the defective switch(es) and the fuse T6.3A.
If the fuse T6.3A is blown, there is a shorts or grounds in electrical parts or wire harness.
Che
2-1 Programming problems.
a) When touching the pads, a certain group of pads do not produce a signal.
b) When touching the pads, no pads produce a signal.
2-2 Display problems.
a) For a certain digit, all or some segments do not light up.
b) For a certain digit, brightness is low.
c) Only one indicator does not light up.
d) The corresponding segments of all digits do not light up; or they continue
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary
on the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide
given below for repair.
Problem: POWER ON, indicator does not light up.
CARRY OUT 3D CHECKS.
STEPS
OCCURRENCE
CAUSE OR CORRECTION
The rated voltage is not applied between Pin
1
No. 3 of the 2 pin connector (A) and the
Check supply voltag
Sharp R-231F The touch control section consists of the following units as
shown in the touch control panel circuit.
(1) Key Unit
(2) Control Unit
The principal functions of these units and their related
signals are explained below.
Key Unit
The key unit is composed of a matrix, signals generated in
the LSI are sent to the key unit through R00, R01, R02,
R03, R20 and R21.
When a key pad is touched, a signal is completed through
the key unit and passed back to
DESCRIPTION OF LSI
The I/O signal of the LSI are detailed in the following table.
Pin No.
Signal
I/O
Description
1
RESET
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is supplied.
Temporarily set to “L” level the moment power is supplied, at this time the LSI is
reset. Thereafter set at “H” level.
2
TEST
IN
Connected to GND.
3
VSS
IN
Power source voltage: -5V.
VSS voltage of power source circuit