PRECAUTIONS TO BE OBSERVED BEFORE AND

DURING SERVICING TO AVOID POSSIBLE EXPO- SURE TO EXCESSIVE MICROWAVE ENERGY CHAPTER 1. WARNING TO SERVICE PERSONNEL CHAPTER 2. MICROWAVE MEASUREMENT PRO- CEDURE CHAPTER 3. FOREWORD AND WARNING CHAPTER 4. PRODUCT DESCRIPTION CHAPTER 5. GENERAL INFORMATION CHAPTER 6. OPERATION CHAPTER 7. TROUBLESHOOTING GUIDE CHAPTER 8. TEST PROCEDURES CHAPTER 9. TOUCH CONTROL PANEL ASSEMBLY CHAPTER 10. PRECAUTIONS FOR USING LEAD- FREE S

PRECAUTIONS TO BE OBSERVED BEFORE

AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENER- GY CHAPTER 1. WARNING TO SERVICE PERSON- NEL [1] Before Servicing.......................................... 1-1 [2] When the testing is completed,................... 1-1 [3] After repairing.............................................. 1-1 CHAPTER 2. MICROWAVE MEASUREMENT PROCEDURE [1] Requirements:........................................

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID

POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY BEFORE SERVICING PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY (a) Do not operate or allow the oven to be operated with the door open. (b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave

1 – 1

R305MR Service Manual CHAPTER 1. WARNING TO SERVICE PERSONNEL Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (Example) High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness etc.. Read the Service Manual carefully and follow all instructions. [1] Befor

Sharp R-305MR 2 – 1

R305MR Service Manual CHAPTER 2. MICROWAVE MEASUREMENT PROCEDURE [1] Requirements: 1. Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/ cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the use- ful life of the oven), 5 mW/cm2 at any point 5cm or more from the extern

3 – 1

R305MR Service Manual CHAPTER 3. FOREWORD AND WARNING [1] FOREWORD This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP MICROWAVE OVEN, R-305MR. It is recommended that service personnel carefully study the entire text of this manual so that they will be qualified to render satisfactory customer service. Check the interlock switches and the door seal carefully

4 – 1

R305MR Service Manual CHAPTER 4. PRODUCT DESCRIPTION [1] SPECIFICATIONS ITEM DESCRIPTION Power Requirements 120 Volts 60 Hertz Single phase, 3 wire grounded Power Consumption 1530W / Approx. 13 Amperes Power Output 1100 W nominal of RF microwave energy (IEC Test procedure) Operating frequency 2450 MHz Case Dimensions Width 20-1/2" (520mm) Height 12-1/4" (310mm) Depth 17" (431mm) Cooking Cavity Dimensions (1.0 Cubic feet) Width 14-3

5 – 1

R305MR Service Manual CHAPTER 5. GENERAL INFORMATION [1] GROUNDING INSTRUCTIONS This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed and grounded in accor- dance with the National Electrical Code and local codes and ordinances. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current.

Sharp R-305MR 5 – 2

2. TOUCH CONTROL PANEL NOTE: Some one-touch cooking features such as “MINUTE PLUS” are disabled after three minutes when the oven is not in use. These fea- tures are automatically enabled when the door is opened and closed or the STOP/ CLEAR pad is pressed.

6 – 1

R305MR Service Manual CHAPTER 6. OPERATION [1] DESCRIPTION OF OPERATING SEQUENCE The following is a description of component functions during oven operation. 1. OFF CONDITION Closing the door activates door sensing switch and secondary inter- lock switch. (In this condition, the monitor switch contacts are opened.) When oven is plugged in, 120 volts A.C. is supplied to the noise filter and the control unit. (Figure O-1). 1) The display will

6 – 2

[2] OVEN SCHENATIC 1. Off Condition Figure O-1. Oven Schematic-Off Condition 2. Cooking Condition Figure O-2. Oven Schematic-Cooking Condition SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED 2. CLOCK APPEARS ON DISPLAY SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED. 2. COOKING TIME PROGR

Sharp R-305MR 6 – 3

[3] DESCRIPTION AND FUNCTION OF COMPONENTS 1. DOOR OPEN MECHANISM The door is opened by pushing the open button on the control panel, refer to the Figure D-1. When the open button is pushed, the open button pushes up the switch lever, and then the switch lever pushes up the latch head. The latch heads are moved upward and released from latch hook. Now the door will open. Figure D-1. Door Open Mechanism. 2.

7 – 1

R305MR Service Manual CHAPTER 7. TROUBLESHOOTING GUIDE Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected. When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in th

8 – 1

R305MR Service Manual CHAPTER 8. TEST PROCEDURES [1] A: MAGNETRON ASSEMBLY TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. To test for an open filament, isolate the magnetron from the high voltage circuit. A continuity check across the magnetron filament leads should indicate less than 1 ohm. 5. To test for a shorted magnetron, connect the ohmm

Sharp R-305MR 8 – 2

6. Reinstall the outer case (cabinet). 7. Reconnect the power supply cord after the outer case is installed. 8. Run the oven and check all functions. NOTE: Be sure to use an ohmmeter that will supply a forward bias voltage of more than 6.3 volts. [4] D: HIGH VOLTAGE CAPACITOR TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the capacitor is op

8 – 3

2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Isolate the switch and connect the ohmmeter to the common (COM.) and normally open (NO) terminal of the switch. The meter should indicate an open circuit with the door open and a closed circuit with the door closed. If improper operation is indicated, replace the door sensing switch. 5. Reconnect all leads removed from components during testing. 6. Reinstall the oute

8 – 4

If the monitor fuse is blown by improper switch operation, the monitor fuse and monitor switch must be replaced with “monitor fuse and monitor switch assembly” part number FFS-BA033WRKZ or FFS-BA037WRKZ, even if the monitor switch operates normally. The monitor fuse and moni- tor switch assembly is comprised of a 20 ampere fuse and switch. 5. Reconnect all leads removed from components during testing. 6. Reinstall the outer case (cabinet

8 – 5

d) The corresponding segments of all digits do not light up; or they continue to light up. e) Wrong figure appears. f) A certain group of indicators do not light up. g) The figure of all digits flicker. 3) Other possible problems caused by defective control unit. a) Buzzer does not sound or continues to sound. b) Clock does not operate properly. c) Cooking is not possible. 3. If the Key unit or control unit is defective. 1) Disconnect the po

8 – 6

[13] L: RELAY TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Disconnect the leads to the primary of the power transformer. 5. Ensure that these leads remain isolated from other components and oven chassis by using insulation tape. 6. After that procedure, re-connect the power supply cord. 7. Remove the outer case and check voltage between the c

Sharp Microwave Oven Owners Instructions: