Sharp R-310BK Service Manual

Text of Sharp R-310BK Service Manual

In the interest of user-safety the oven should be restored to its original

condition and only parts identical to those specified should be used. WARNING TO SERVICE PERSONNEL: Microwave ovens con- tain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Recti- fier A

PRECAUTIONS TO BE OBSERVED BEFORE AND

DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY (a) Do not operate or allow the oven to be operated with the door open. (b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of pro- ducing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (Example) High Voltage Capacitor, High Voltage Power Trans- former, Magnetron, High Voltage Rectifier Assem- bly, High Voltage Harness etc.. Read the Service Manual carefully and follow all instructions. Before Servicing 1. Disconnect t

Sharp R-310BK MICROWAVE MEASUREMENT PROCEDURE

A. Requirements: 1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external surface of the oven. 2) Safety i

SHARP ELECTRONICS CORPORATION

SHARP PLAZA, MAHWAH, NEW JERSEY 07430-2135 SERVICE MANUAL MICROWAVE OVEN R-310BK/ R-310BW FOREWORD This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP MICROWAVE OVEN, R-310BK, R-310BW. It is recommended that service personnel carefully study the entire text of this manual so that they will be qualified to render satisfactory c

120 Volts / 14 Amperes

60 Hertz Single phase, 3 wire grounded Power Output 1100 watts (IEC-705 TEST PROCEDURE) Operating frequency of 2450MHz Case Dimensions Width 20-1/2" Height 11-7/8" Depth 15-7/8" Cooking Cavity Dimensions Width 13-3/4" Height 8-3/8" 1.0 Cubic Feet Depth 14-7/8" Control Complement Touch Control System Clock ( 1:00 - 12:59 ) Timer (0 - 99 min. 99 seconds) Microwave Power for Variab

A short power-supply cord is provided to reduce risks of becoming

entangled in or tripping over a longer cord. Where a two-pronged wall-receptacle is encountered, it is the personal responsibility and obligation of the customer to contact a qualified electrician and have it replaced with a properly grounded three-pronged wall receptacle or have a grounding adapter properly grounded and polarized. If the extension cord must be used, it sh

DESCRIPTION OF OPERATING SEQUENCE

The following is a description of component functions during oven operation. OFF CONDITION Closing the door activates door sensing switch and second- ary interlock switch. (In this condition, the monitor switch contacts are opened.) When oven is plugged in, 120 volts A.C. is supplied to the control unit. (Figure O-1). 1. The display will show flashing "88:88". To set any program or set the clock

Figure O-1. Oven Schematic-Off Condition

SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED 2. CLOCK APPEARS ON DISPLAY SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED 2. COOKING TIME PROGRAMMED 3. VARIABLE COOKING CONTROL "HIGH" 4. "START" PAD TOUCHED Figure O-2. Oven Schematic-Cooking Condition 120V AC 60 Hz OVEN LAMP TURN- TABLE MOTOR FAN MOTOR POWER TRANSFORMER MONITOR SWITCH RECTIFIER MAGNETRON SECONDARY INTERLOCK SWITCH TTM OL FM MON

Sharp R-310BK DESCRIPTION AND FUNCTION OF COMPONENTS

DOOR OPEN MECHANISM The door is opened by pushing the open button on the control panel, refer to the Figure D-1. When the open button is pushed, the open button pushes up the switch lever, and then the switch lever pushes up the latch head. The latch heads are moved upward and re- leased from latch hook. Now the door will open. open, the monitor fuse blows simultaneously with closing of the monitor s

Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected.

When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the "Test Procedure "section. IMPORTANT:

Home fuse or circuit breaker

blows when power cord is plugged into wall receptacle Monitor fuse blows when power cord is plugged into wall recepta- cle. All letters and indicators do not appear in display when power cord is first plugged into wall out- let. Display does not operate prop- erly when STOP/CLEAR key is touched. (Buzzer should sound and ":" or time of day should ap- pear in display.) Oven lamp does not light when door is open

Sharp R-310BK POWER TRANSFORMER TEST

1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Disconnect the primary input terminals and measure the resistance of the transformer with an ohmmeter. Check for continuity of the coils with an ohmmeter. On the R x 1 scale, the resistance of the primary coil should be less than 1 ohm and the resistance of the high voltage

1. Disconnect the power supply cord, and then remove outer case.

2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the capacitor is open, no high voltage will be available to the magnetron. Disconnect input leads and check for short or open between the terminals using an ohmmeter. Checking with a high ohm scale, if the high voltage capacitor is normal, the meter
1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Before performing this test, make sure that the secondary interlock switch and the primary interlock relay are operating properly, according to the above Switch Test Procedure. Disconnect the wire lead from the monitor switch (COM) terminal. Check the

BLOWN MONITOR FUSE TEST

TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the monitor fuse is blown when the door is opened, check the primary interlock relay, secondary interlock switch and monitor switch according to the "TEST PROCEDURE" for those switches before replacing the blown monitor fus

7) Reconnect the power supply cord after the outer case is installed.

8) Run the oven and check all functions. The following symptoms indicate a defective key unit. a) When touching the pads, a certain pad produces no signal at all. b) When touching a number pad, two figures or more are displayed. c) When touching the pads, sometimes a pad produces no signal. If the key unit is defective. 1) Disconnect the power supply cord, and then rem

WARNING : The oven should be fully assembled before following procedure.

(1) Place one cup of water in the center of the turntable tray in the oven cavity. (2) Close the door, touch the " COMPU DEFROST " pad twice and touch the Number pad "5". And then touch the "START" pad. (3) The oven is in Compu Defrost cooking condition. (4) The oven will operate as follows WEIGHT 1ST STAGE 2ND STAGE 3RD STAGE LEVEL TIME LEVEL TIME LEVEL TIME 0.5lb

To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on

the PWB, this foil pattern acts as a fuse. 1. Foil pattern check and repairs. 1) Disconnect the power supply cord, and then remove outer case. 2) Open the door and block it open. 3) Discharge high voltage capacitor. 4) Follow the troubleshooting guide given below for repair. STEPS OCCURRENCE CAUSE OR CORRECTION 1 Only pattern at "a

Sharp R-310BK TOUCH CONTROL PANEL ASSEMBLY

OUTLINE OF TOUCH CONTROL PANEL The touch control section consists of the following units. (1) Key Unit (2) Control Unit (The Control Unit consists of Power Unit and CPU Unit). The principal functions of these units and the signals com- municated among them are explained below. Key Unit The key unit is composed of a matrix, signals generated in the LSI are sent to the key unit through P73, P81, P82, P83, P90 a

Sharp Microwave Oven Owners Instructions: