Sharp R-314FS Service Manual
Text of Sharp R-314FS Service Manual
In the interest of user-safety the oven should be restored to its original
condition and only parts identical to those specified should be used.
WARNING TO SERVICE PERSONNEL: Microwave ovens con-
tain circuitry capable of producing very high voltage and
current, contact with following parts may result in a severe,
possibly fatal, electrical shock. (High Voltage Capacitor, High
Voltage Power Transformer, Magnetron, High Voltage Recti-
fie
PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE
ENERGY
(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3)
seal and sealing surfaces (arcing, wear, and oth
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of pro-
ducing very high voltage and current, contact with
following parts may result in a severe, possibly
fatal, electrical shock.
(Example)
High Voltage Capacitor, High Voltage Power Trans-
former, Magnetron, High Voltage Rectifier Assem-
bly, High Voltage Harness etc..
Read the Service Manual carefully and follow all
instructions.
Before Servicing
1. Disconnect t
Sharp R-314FS MICROWAVE MEASUREMENT PROCEDURE
A. Requirements:
1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven
should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition
by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external
surface of the oven.
2) Safety i
Sharp R-314FS SHARP ELECTRONICS CORPORATION
SHARP PLAZA, MAHWAH,
NEW JERSEY 07430-2135
SERVICE MANUAL
MICROWAVE OVEN
R-314FS/ R-316FS
FOREWORD
This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service
Information for the SHARP MICROWAVE OVENS, R-314FS and R-316FS.
The models R-314FS and R-316FS are quite similar to base model R-301FW (Refer No. is S2204R301FPW/).
It is recommended that service personn
120 Volts / 13 Amperes
60 Hertz
Single phase, 3 wire grounded
Power Output
1000 watts (IEC TEST PROCEDURE)
Operating frequency of 2450MHz
Case Dimensions
Width 20-1/2"
Height 11-7/8"
Depth 16-3/4"
Cooking Cavity Dimensions
Width 14-3/4"
Height 8-3/4"
1.2 Cubic Feet
Depth 15-3/4"
Control Complement
Touch Control System
Clock ( 1:00 - 12:59 )
Timer (0 - 99 min. 99 seconds)
Microwave Power for Variable C
contact a qualified electrician and have it replaced with a properly
grounded three-pronged wall receptacle or have a grounding adapter
properly grounded and polarized. If the extension cord must be used, it
should be a 3-wire, 15 amp. or higher rated cord. Do not drape over a
countertop or table where it can be pulled on by children or tripped over
accidentally.
CAUTION: DO NOT UNDER ANY CIRCUMSTANCES CUT OR RE-
MOVE THE ROUND GROUNDING
GRAPHIC SHEET AND MEMBRANE SWITCH REPLACEMENT
Figure O-1. Oven Schematic-Off Condition
SCHEMATIC
NOTE: CONDITION OF OVEN
1. DOOR CLOSED
2. CLOCK APPEARS ON DISPLAY
120V AC
60 Hz
OVEN
LAMP
OVEN LAMP
RELAY
TURN-
TABLE
MOTOR
FAN
MOTOR
POWER
TRANSFORMER
MONITOR
SWITCH
RECTIFIER
MAGNETRON
SECONDARY
INTERLOCK
SWITCH
TTM
OL
FM
MONITOR
FUSE 20A
N.O.
N.O.
COM.
COM.
DOOR
SENSING
SWITCH
(RY1)
(RY2)
CONTROL UNIT
PRIMARY
INTERLOCK
RELAY
OVEN THERMAL
1. Disconnect the power supply cord.
2. Open the door slightly.
3. Insert a putty knife (thickness of about 0.5mm) into the
gap between the choke cover and door frame as shown
in Figure C-4 to free engaging parts.
4. Pry the choke cover by inserting a putty knife as shown
Figure C-4.
5. Release choke cover from door panel.
6. Now choke cover is free.
NOTE: When carrying out any repair to the door, do not
bend or
CORD 120V 60Hz
HIGH VOLTAGE COMPONENTS
MAGNETRON
COM.
MONITOR
SWITCH
COM.
N.O.
N.C.
DOOR
SENSING
SWITCH
SECONDARY
INTERLOCK
SWITCH
TURNTABLE
MOTOR
POWER
TRANSFORMER
COM.
NO
NOTE:
The neutral (WHT) wire must be
connected to the terminal with "N"
mark on the power supply cord.
WHT
RED
GRY
WHT
RED
GRY
YLW
WHT
BLK
R
E
D
Y
L
W
B
L
K
R
E
D
Note: The parts marked “∆” may cause undue microwave exposure.
The parts marked “*” are used in voltage more than 250V.
REF. NO.
PART NO.
DESCRIPTION
Q'TY
CODE
ELECTRIC PARTS
1- 1
QSW-MA147WRZZ
Secondary interlock switch/door sensing switch
2
AG
1- 1
QSW-MA137WRE0
Secondary interlock switch/door sensing switch (Interchangeable)
2
AH
1- 2
QFSHDA009WRE0
Fuse holder
1
AG
1- 3
FFS-BA023WRK0
Mon
Sharp R-314FS HOW TO ORDER REPLACEMENT PARTS
To have your order filled promptly and correctly, please furnish the following information.
1. MODEL NUMBER
2. REF. NO.
3. PART NO.
4. DESCRIPTION
Order Parts from the authorized SHARP parts Distributor for your area.
Defective parts requiring return should be returned as indicated in the Service Policy.
∆
∆
∆
∆
∆
REF. NO.
PART NO.
DESCRIPTION
Q'TY
CODE
4-19
PCUSUA474WRP0
Cushion
2
AC
4-20
PCUSGA5
OVEN AND CABINET PARTS
7-6
7-8
7-6
7-8
6-7
2-1
4-13
4-17
4-14
4-2
1-12
7-1
7-5
1-7
4-11
4-11
1-8
4-22
4-9
4-20
4-21
1-6
1-1
7-1
2-3
7-6
7-6
7-6
1-9
4-6
1-11
7-1
7-6
4-16
4-18
7-3
7-2
4-8
7-4
4-4
4-15
4-19
7-6
7-6
1-4
4-7
7-7
7-10
4-12
6-2
6-1
4-1
7-6
1-3
1-2
1-1
4-3
4-5
2-2
1-13
7-3
7-6
7-1
1-10
4-10
1-5
6-6
7-9
4-19
CONTROL PANEL PARTS
MISCELLANEOUS
3-1-1
3-1
3-9
3-8
3-10
3-6
3-4
3-3
3-1-2
Before attaching Control unit to Control
panel, foil side of Control unit must be
cleaned by ethyl-alcohol.
3-2
3-2-1
3-2-2
Actual wire harness may be different from illustration.
6-3
6-5
5-1
5-3
5-6
5-2
5-5
5-8
5-4
5-7
5-3-2
5-3-1
5-3-3
PACKING AND ACCESSORIES
6
4
5
1
2
3
6
4
5
1
2
3
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
DOOR PROTECTION SHEET
SPADPA204WRE0
TOP PAD ASSEMBLY
FPADBA492WRKZ
PLASTIC BAG
SSAKHA034WRE0
Not replaceable items.
PACKING CASE
FPAK-A435WRKZ [R-314FS]
FPAK-A436WRKZ [R-316FS]
BOTTOM PAD ASSEMBLY
FPADBA493WRKZ
6- 2 TURNTABLE TRAY
6- 4 INSTRUCTION BOOK
& PRINTING MATTER
6- 1 TURNTABLE SUPPORT
TRAY PACK
SPADFA527WREZ
INTO THE
OVEN CAVITY
2002 SHARP CORP. (2S1.700E) Printed in U.S.A
COPYRIGHT © 2002 BY SHARP CORPORATION
ALL RIGHTS RESERVED.
No part of this publication may be reproduced,
stored in retrieval systems, or transmitted in any
form or by any means, electronic, mechanical,
photocopying, recording, or otherwise, without
prior written permission of the publisher.