Sharp R-314FS Service Manual

Text of Sharp R-314FS Service Manual

In the interest of user-safety the oven should be restored to its original

condition and only parts identical to those specified should be used. WARNING TO SERVICE PERSONNEL: Microwave ovens con- tain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Recti- fie

PRECAUTIONS TO BE OBSERVED BEFORE AND

DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY (a) Do not operate or allow the oven to be operated with the door open. (b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and oth

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of pro- ducing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (Example) High Voltage Capacitor, High Voltage Power Trans- former, Magnetron, High Voltage Rectifier Assem- bly, High Voltage Harness etc.. Read the Service Manual carefully and follow all instructions. Before Servicing 1. Disconnect t

Sharp R-314FS MICROWAVE MEASUREMENT PROCEDURE

A. Requirements: 1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external surface of the oven. 2) Safety i

Sharp R-314FS SHARP ELECTRONICS CORPORATION

SHARP PLAZA, MAHWAH, NEW JERSEY 07430-2135 SERVICE MANUAL MICROWAVE OVEN R-314FS/ R-316FS FOREWORD This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP MICROWAVE OVENS, R-314FS and R-316FS. The models R-314FS and R-316FS are quite similar to base model R-301FW (Refer No. is S2204R301FPW/). It is recommended that service personn

120 Volts / 13 Amperes

60 Hertz Single phase, 3 wire grounded Power Output 1000 watts (IEC TEST PROCEDURE) Operating frequency of 2450MHz Case Dimensions Width 20-1/2" Height 11-7/8" Depth 16-3/4" Cooking Cavity Dimensions Width 14-3/4" Height 8-3/4" 1.2 Cubic Feet Depth 15-3/4" Control Complement Touch Control System Clock ( 1:00 - 12:59 ) Timer (0 - 99 min. 99 seconds) Microwave Power for Variable C

contact a qualified electrician and have it replaced with a properly

grounded three-pronged wall receptacle or have a grounding adapter properly grounded and polarized. If the extension cord must be used, it should be a 3-wire, 15 amp. or higher rated cord. Do not drape over a countertop or table where it can be pulled on by children or tripped over accidentally. CAUTION: DO NOT UNDER ANY CIRCUMSTANCES CUT OR RE- MOVE THE ROUND GROUNDING

GRAPHIC SHEET AND MEMBRANE SWITCH REPLACEMENT

Figure O-1. Oven Schematic-Off Condition SCHEMATIC NOTE: CONDITION OF OVEN 1. DOOR CLOSED 2. CLOCK APPEARS ON DISPLAY 120V AC 60 Hz OVEN LAMP OVEN LAMP RELAY TURN- TABLE MOTOR FAN MOTOR POWER TRANSFORMER MONITOR SWITCH RECTIFIER MAGNETRON SECONDARY INTERLOCK SWITCH TTM OL FM MONITOR FUSE 20A N.O. N.O. COM. COM. DOOR SENSING SWITCH (RY1) (RY2) CONTROL UNIT PRIMARY INTERLOCK RELAY OVEN THERMAL

1. Disconnect the power supply cord.

2. Open the door slightly. 3. Insert a putty knife (thickness of about 0.5mm) into the gap between the choke cover and door frame as shown in Figure C-4 to free engaging parts. 4. Pry the choke cover by inserting a putty knife as shown Figure C-4. 5. Release choke cover from door panel. 6. Now choke cover is free. NOTE: When carrying out any repair to the door, do not bend or

CORD 120V 60Hz

HIGH VOLTAGE COMPONENTS MAGNETRON COM. MONITOR SWITCH COM. N.O. N.C. DOOR SENSING SWITCH SECONDARY INTERLOCK SWITCH TURNTABLE MOTOR POWER TRANSFORMER COM. NO NOTE: The neutral (WHT) wire must be connected to the terminal with "N" mark on the power supply cord. WHT RED GRY WHT RED GRY YLW WHT BLK R E D Y L W B L K R E D

Note: The parts marked “∆” may cause undue microwave exposure.

The parts marked “*” are used in voltage more than 250V. REF. NO. PART NO. DESCRIPTION Q'TY CODE ELECTRIC PARTS 1- 1 QSW-MA147WRZZ Secondary interlock switch/door sensing switch 2 AG 1- 1 QSW-MA137WRE0 Secondary interlock switch/door sensing switch (Interchangeable) 2 AH 1- 2 QFSHDA009WRE0 Fuse holder 1 AG 1- 3 FFS-BA023WRK0 Mon

Sharp R-314FS HOW TO ORDER REPLACEMENT PARTS

To have your order filled promptly and correctly, please furnish the following information. 1. MODEL NUMBER 2. REF. NO. 3. PART NO. 4. DESCRIPTION Order Parts from the authorized SHARP parts Distributor for your area. Defective parts requiring return should be returned as indicated in the Service Policy. ∆ ∆ ∆ ∆ ∆ REF. NO. PART NO. DESCRIPTION Q'TY CODE 4-19 PCUSUA474WRP0 Cushion 2 AC 4-20 PCUSGA5

OVEN AND CABINET PARTS

7-6 7-8 7-6 7-8 6-7 2-1 4-13 4-17 4-14 4-2 1-12 7-1 7-5 1-7 4-11 4-11 1-8 4-22 4-9 4-20 4-21 1-6 1-1 7-1 2-3 7-6 7-6 7-6 1-9 4-6 1-11 7-1 7-6 4-16 4-18 7-3 7-2 4-8 7-4 4-4 4-15 4-19 7-6 7-6 1-4 4-7 7-7 7-10 4-12 6-2 6-1 4-1 7-6 1-3 1-2 1-1 4-3 4-5 2-2 1-13 7-3 7-6 7-1 1-10 4-10 1-5 6-6 7-9 4-19

CONTROL PANEL PARTS

MISCELLANEOUS 3-1-1 3-1 3-9 3-8 3-10 3-6 3-4 3-3 3-1-2 Before attaching Control unit to Control panel, foil side of Control unit must be cleaned by ethyl-alcohol. 3-2 3-2-1 3-2-2 Actual wire harness may be different from illustration. 6-3 6-5 5-1 5-3 5-6 5-2 5-5 5-8 5-4 5-7 5-3-2 5-3-1 5-3-3

PACKING AND ACCESSORIES

6 4 5 1 2 3 6 4 5 1 2 3 A B C D E F G H A B C D E F G H DOOR PROTECTION SHEET SPADPA204WRE0 TOP PAD ASSEMBLY FPADBA492WRKZ PLASTIC BAG SSAKHA034WRE0 Not replaceable items. PACKING CASE FPAK-A435WRKZ [R-314FS] FPAK-A436WRKZ [R-316FS] BOTTOM PAD ASSEMBLY FPADBA493WRKZ 6- 2 TURNTABLE TRAY 6- 4 INSTRUCTION BOOK & PRINTING MATTER 6- 1 TURNTABLE SUPPORT TRAY PACK SPADFA527WREZ INTO THE OVEN CAVITY

2002 SHARP CORP. (2S1.700E) Printed in U.S.A

COPYRIGHT © 2002 BY SHARP CORPORATION ALL RIGHTS RESERVED. No part of this publication may be reproduced, stored in retrieval systems, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of the publisher.

Sharp Microwave Oven Owners Instructions: