Sharp R-350F Service Manual

Text of Sharp R-350F Service Manual

In interests of user-safety the oven should be restored to its

original condition and only parts identical to those specified should be used. TABLE OF CONTENTS Page CAUTION, MICROWAVE RADIATION............................................................................................................. 1 WARNING.............................................................

Sharp R-350F GENERAL IMPORTANT INFORMATION

This Manual has been prepared to provide Sharp Corp. Service engineers with Operation and Service Information. It is recommended that service engineers carefully study the entire text of this manual, so they will be qualified to render satisfactory customer service. CAUTION MICROWAVE RADIATION DO NOT BECOME EXPOSED TO RADIATION FROM THE MICROWAVE GENERATOR OR OTHER PARTS CONDUCTING

230 - 240 Volts

50 Hertz Single phase, 3 wire earthed Power Consumption 1.75kW Power Output 1200 watts nominal of RF microwave energy (IEC Test Procedure) Operating frequency 2450 MHz Case Dimensions Width 520 mm Height 302 mm including foot Depth 436 mm Cooking Cavity Dimensions Width 374 mm Height 227 mm Depth 399 mm Turntable diameter 335 mm Control Complement Touch Control System Clock ( 1:00 - 12:59) Timer

1. Door handle

2. Oven lamp 3. Door hinges 4. Door safety latches 5. See through door 6. Door seals and sealing surfaces 7. Coupling 8. Wave guide cover 9. Touch control panel 10.Digital readout 11.Ventilation openings 12.Power supply cord 13.Turntable tray 14.Turntable support 15.Menu label TOUCH CONTROL PANEL NOTE: Some one-touch cooking features such as "INSTANT COOK" are disabled after three minutes when the oven is not in use.

Closing the door activates all door interlock switches

(1st. latch switch and 2nd. interlock relay control switch). IMPORTANT When the oven door is closed, the monitor switch contacts (COM-NC) must be open. When the microwave oven is plugged in a wall outlet, rated voltage is supplied to the noise filter and the control unit. Figure O-1 on page 25 1. The display shows "SHARP , MICRO-WAVE and OVEN". 2. To set any pr

FUNCTION OF IMPORTANT COMPONENTS

closed. However, when abnormally high temperatures are reached within the oven cavity, the oven thermal cut-out will open at 125˚C, causing the oven to shut down. The defective thermal cut-out must be replaced with new one. MAGNETRON THERMAL CUT-OUT The thermal cut-out located near the magnetron is de- signed to prevent damage to the magnetron if an over heated condition develops in the tube due to cooling fan fa

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts of the high voltage circuit will result in electrocution. High voltage capacitor, Power transformer, Magnetron, High voltage rectifier assembly, High voltage fuse, High voltage harness. REMEMBER TO CHECK 3D 1) Disconnect the supply. 2) Door opened, and wedged open. 3) Discharge the high voltage

Sharp R-350F CK = Check / RE = Replace

MAGNETRON POWER TRANSFORMER H.V. RECTIFIER ASSEMBLY HIGH VOLTAGE CAPACITOR 1ST. LATCH SWITCH 2ND. INTERLOCK RELAY CONTROL SWITCH MONITOR SWITCH THERMAL CUT-OUT 95˚C /125˚C FAN MOTOR TURNTABLE MOTOR FUSE F10A TOUCH CONTROL PANEL KEY UNIT RELAY (RY-1, RY-2) FOIL PATERN ON P.W.B. POWER SUPPLY CORD SHORTED WIRE HARNESS OPENED WIRE HARNESS OVEN LAMP OR SOCKET WALL OUTLET MISADJUSTMENT SWITCH HOME FUSE OR BREAKER BLOCKED COO

NEVER TOUCH ANY PART IN THE CIRCUIT WITH YOUR HAND OR AN INSULATED TOOL

WHILE THE OVEN IS IN OPERATION. CARRY OUT 3D CHECK. Isolate the magnetron from high voltage circuit by removing all leads connected to filament terminal. To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron filament terminals, the meter should show a reading of less than 1 ohm. To test for short filament to anode condition, conne

Room temperature .................. To = 21˚C

Initial temperature ................. T1 = 11°C Temperature after (35 + 3) = 38 sec. ................................................................ T2 = 21°C Temperature difference Cold-Warm .............................................................. ∆T1 = 10°C Measured output power The equation is “P = 120 x ∆T” ........................................... P = 120 x 10°C = 1200 Watts

MOTOR WINDING TEST

TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST D HIGH VOLTAGE CAPACITOR TEST CARRY OUT 3D CHECKS. A. Isolate the high voltage capacitor from the circuit. B. Continuity check must be carried out with measuring instrument which is set to the highest resistance range. C. A normal capacitor shows continuity for a short time (kick) and then a resistance of about 10MΩ after it has been charged. D. A short-circuited capacitor sho

Table: Resistance of Motor

Motors Resistance Fan motor Approximately 405 Ω Turntable motor Approximately 14.8 kΩ If incorrect readings are obtained, replace the motor. CARRY OUT 4R CHECKS CARRY OUT 3D CHECKS. 1. If the fuse F10A is blown, there could be shorts or ground in electrical parts or wire harness. Check them and replace the defective parts or repair the wire harness. 2. If the fuse F10A

KEY UNIT TEST

If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable is making good contact, verify that the 2nd. interlock relay control switch operates properly; that is the contacts are closed when the door is closed and open when the door is open. If the door 2nd. interlock relay control switch is good, disconnect the flat ribbon cab

To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary

on the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide given below for repair. Problem: POWER ON, indicator does not light up. CARRY OUT 3D CHECKS. STEPS OCCURRENCE CAUSE OR CORRECTION The rated AC voltage is not present between 1 Pin No. 1 of the 2-pin connector (A) and the Check supply vol

TOUCH CONTROL PANEL ASSEMBLY

OUTLINE OF TOUCH CONTROL PANEL The touch control section consists of the following units. (1) Key Unit (2) Control Unit (The Control Unit consists of Power Unit and LSI Unit). The principal functions of these units and the signals communicated among them are explained below. Key Unit The key unit is composed of a matrix, signals generated in the LSI are sent to the key unit through P00-P07. When a key pad is touched,

Sharp R-350F Terminal not used.

22-26 P24-P20 IN Terminal not used. 27 P47 IN To input signal which communicates the door open/close information to LSI. Door close "H" level signal (0V). Door open "L" level signal (-5V). 28 P46 OUT Terminal not used. 29 P45 OUT Oven lamp, fan motor and turntable motor driving signal. To turn on and off shut off relay (RY1). The square waveform voltage is delivered to the RY1 d

Signal similar to P17.

When either G12 line on key matrix is touched, a corresponding signal will be input into P14. 47 AIN7 IN Signal similar to P17. When either G13 line on key matrix is touched, a corresponding signal will be input into AIN7. 48 AIN6 IN Input terminal to judge the model. The signal out of P07 will be input into AIN6 through G1 line on key matrix. The LSI will judge the model by this signal. 49-50 AIN5-AIN4 IN Connect

1. Precautions for Handling Electronic Components

This unit uses CMOS LSI in the integral part of the circuits. When handling these parts, the following precautions should be strictly followed. CMOS LSI have extremely high impedance at its input and output terminals. For this reason, it is easily influenced by the surrounding high voltage power source, static electricity charge in clothes, etc. and sometimes it is not fully protected by the built

Sharp R-350F COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE

WARNING: Avoid possible exposure to microwave energy. Please follow the instructions below before operating the oven. 1. Disconnect oven from power supply. 2. Visually check the door and cavity face plate for damage (dents, cracks, signs of arcing etc.). Carry out any remedial work that is necessary before operating the oven. Do not operate the oven if any of the following conditions exist; 1. Door d

Sharp Microwave Oven Owners Instructions: