Sharp R-350F Service Manual
Text of Sharp R-350F Service Manual
In interests of user-safety the oven should be restored to its
original condition and only parts identical to those specified
should be used.
TABLE OF CONTENTS
Page
CAUTION, MICROWAVE RADIATION............................................................................................................. 1
WARNING.............................................................
Sharp R-350F GENERAL IMPORTANT INFORMATION
This Manual has been prepared to provide Sharp Corp. Service
engineers with Operation and Service Information.
It is recommended that service engineers carefully study the
entire text of this manual, so they will be qualified to render
satisfactory customer service.
CAUTION
MICROWAVE RADIATION
DO NOT BECOME EXPOSED TO RADIATION FROM
THE MICROWAVE GENERATOR OR OTHER PARTS
CONDUCTING
230 - 240 Volts
50 Hertz
Single phase, 3 wire earthed
Power Consumption
1.75kW
Power Output
1200 watts nominal of RF microwave energy (IEC Test Procedure)
Operating frequency 2450 MHz
Case Dimensions
Width 520 mm
Height 302 mm including foot
Depth 436 mm
Cooking Cavity Dimensions
Width 374 mm
Height 227 mm
Depth 399 mm
Turntable diameter
335 mm
Control Complement
Touch Control System
Clock ( 1:00 - 12:59)
Timer
1. Door handle
2. Oven lamp
3. Door hinges
4. Door safety latches
5. See through door
6. Door seals and sealing surfaces
7. Coupling
8. Wave guide cover
9. Touch control panel
10.Digital readout
11.Ventilation openings
12.Power supply cord
13.Turntable tray
14.Turntable support
15.Menu label
TOUCH CONTROL PANEL
NOTE:
Some one-touch cooking features such as "INSTANT COOK" are disabled after three minutes when
the oven is not in use.
Closing the door activates all door interlock switches
(1st. latch switch and 2nd. interlock relay control switch).
IMPORTANT
When the oven door is closed, the monitor switch contacts
(COM-NC) must be open.
When the microwave oven is plugged in a wall outlet, rated
voltage is supplied to the noise filter and the control unit.
Figure O-1 on page 25
1. The display shows "SHARP , MICRO-WAVE and
OVEN".
2. To set any pr
FUNCTION OF IMPORTANT COMPONENTS
closed. However, when abnormally high temperatures are
reached within the oven cavity, the oven thermal cut-out
will open at 125˚C, causing the oven to shut down. The
defective thermal cut-out must be replaced with new one.
MAGNETRON THERMAL CUT-OUT
The thermal cut-out located near the magnetron is de-
signed to prevent damage to the magnetron if an over
heated condition develops in the tube due to cooling fan
fa
WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts
of the high voltage circuit will result in electrocution. High voltage capacitor, Power transformer, Magnetron, High
voltage rectifier assembly, High voltage fuse, High voltage harness.
REMEMBER TO CHECK 3D
1) Disconnect the supply.
2) Door opened, and wedged open.
3) Discharge the high voltage
Sharp R-350F CK = Check / RE = Replace
MAGNETRON
POWER TRANSFORMER
H.V. RECTIFIER ASSEMBLY
HIGH VOLTAGE CAPACITOR
1ST. LATCH SWITCH
2ND. INTERLOCK RELAY CONTROL
SWITCH
MONITOR SWITCH
THERMAL CUT-OUT 95˚C /125˚C
FAN MOTOR
TURNTABLE MOTOR
FUSE F10A
TOUCH CONTROL PANEL
KEY UNIT
RELAY (RY-1, RY-2)
FOIL PATERN ON P.W.B.
POWER SUPPLY CORD
SHORTED WIRE HARNESS
OPENED WIRE HARNESS
OVEN LAMP OR SOCKET
WALL OUTLET
MISADJUSTMENT SWITCH
HOME FUSE OR BREAKER
BLOCKED COO
NEVER TOUCH ANY PART IN THE CIRCUIT WITH YOUR HAND OR AN INSULATED TOOL
WHILE THE OVEN IS IN OPERATION.
CARRY OUT 3D CHECK.
Isolate the magnetron from high voltage circuit by removing all leads connected to filament terminal.
To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron
filament terminals, the meter should show a reading of less than 1 ohm.
To test for short filament to anode condition, conne
Room temperature .................. To = 21˚C
Initial temperature ................. T1 = 11°C
Temperature after (35 + 3) = 38 sec. ................................................................ T2 = 21°C
Temperature difference Cold-Warm .............................................................. ∆T1 = 10°C
Measured output power
The equation is “P = 120 x ∆T” ........................................... P = 120 x 10°C = 1200 Watts
MOTOR WINDING TEST
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
D
HIGH VOLTAGE CAPACITOR TEST
CARRY OUT 3D CHECKS.
A. Isolate the high voltage capacitor from the circuit.
B. Continuity check must be carried out with measuring instrument which is set to the highest
resistance range.
C. A normal capacitor shows continuity for a short time (kick) and then a resistance of about 10MΩ
after it has been charged.
D. A short-circuited capacitor sho
Table: Resistance of Motor
Motors
Resistance
Fan motor
Approximately 405 Ω
Turntable motor
Approximately 14.8 kΩ
If incorrect readings are obtained, replace the motor.
CARRY OUT 4R CHECKS
CARRY OUT 3D CHECKS.
1. If the fuse F10A is blown, there could be shorts or ground in electrical parts or wire harness.
Check them and replace the defective parts or repair the wire harness.
2. If the fuse F10A
KEY UNIT TEST
If the display fails to clear when the STOP/CLEAR pad is depressed, first verify the flat ribbon cable
is making good contact, verify that the 2nd. interlock relay control switch operates properly; that is the
contacts are closed when the door is closed and open when the door is open.
If the door 2nd. interlock relay control switch is good, disconnect the flat ribbon cab
To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary
on the PWB, this foil pattern acts as a fuse. If the foil pattern is open, follow the troubleshooting guide
given below for repair.
Problem: POWER ON, indicator does not light up.
CARRY OUT 3D CHECKS.
STEPS
OCCURRENCE
CAUSE OR CORRECTION
The rated AC voltage is not present between
1
Pin No. 1 of the 2-pin connector (A) and the
Check supply vol
TOUCH CONTROL PANEL ASSEMBLY
OUTLINE OF TOUCH CONTROL PANEL
The touch control section consists of the following units.
(1) Key Unit
(2) Control Unit (The Control Unit consists of Power Unit
and LSI Unit).
The principal functions of these units and the signals
communicated among them are explained below.
Key Unit
The key unit is composed of a matrix, signals generated
in the LSI are sent to the key unit through P00-P07.
When a key pad is touched,
Sharp R-350F Terminal not used.
22-26
P24-P20
IN
Terminal not used.
27
P47
IN
To input signal which communicates the door open/close information to LSI.
Door close "H" level signal (0V). Door open "L" level signal (-5V).
28
P46
OUT
Terminal not used.
29
P45
OUT
Oven lamp, fan motor and turntable motor driving signal.
To turn on and off shut off relay (RY1). The
square waveform voltage is delivered to the
RY1 d
Signal similar to P17.
When either G12 line on key matrix is touched, a corresponding signal will be input into P14.
47
AIN7
IN
Signal similar to P17.
When either G13 line on key matrix is touched, a corresponding signal will be input into AIN7.
48
AIN6
IN
Input terminal to judge the model.
The signal out of P07 will be input into AIN6 through G1 line on key matrix. The LSI will
judge the model by this signal.
49-50 AIN5-AIN4
IN
Connect
1. Precautions for Handling Electronic Components
This unit uses CMOS LSI in the integral part of the
circuits. When handling these parts, the following
precautions should be strictly followed. CMOS LSI
have extremely high impedance at its input and output
terminals. For this reason, it is easily influenced by the
surrounding high voltage power source, static electricity
charge in clothes, etc. and sometimes it is not fully
protected by the built
Sharp R-350F COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE
WARNING: Avoid possible exposure to microwave energy. Please follow the instructions below before
operating the oven.
1. Disconnect oven from power supply.
2. Visually check the door and cavity face plate for damage
(dents, cracks, signs of arcing etc.).
Carry out any remedial work that is necessary before
operating the oven.
Do not operate the oven if any of the following conditions
exist;
1. Door d