Sharp R-380LS Service Manual
Text of Sharp R-380LS Service Manual
CHAPTER 1. BEFORE SERVICING
CHAPTER 2. WARNING TO SERVICE PERSONNEL
CHAPTER 3. PRODUCT SPECIFICATIONS
CHAPTER 4. APPEARANCE VIEW
CHAPTER 5. OPERATION SEQUENCE
CHAPTER 6. FUNCTION OF IMPORTANT COMPO-
NENTS
CHAPTER 7. TROUBLESHOOTING GUIDE
CHAPTER 8. TEST PROCEDURES
CHAPTER 9. TOUCH CONTROL PANEL ASSEMBLY
CHAPTER 10. PRECAUTIONS FOR USING LEAD-
FREE SOLDER
CHAPTER 11. COMPONENT REPLACEMENT AND
ADJUSTMENT PROCEDURE
CHAPTER 12. MICROWAVE MEASUREMENT
CHAPTER 13
CHAPTER 1. BEFORE SERVICING CHAPTER 2. WARNING TO SERVICE PERSON-
NEL
CHAPTER 3. PRODUCT SPECIFICATIONS
CHAPTER 4. APPEARANCE VIEW
CHAPTER 5. OPERATION SEQUENCE
[1]
OFF CONDITION........................................ 5-1
[2]
MICROWAVE COOKING CONDITION....... 5-1
[3]
POWER OUTPUT REDUCTION ................ 5-1
[4]
SENSOR COOKING CONDITION.............. 5-1
CHAPTER 6. FUNCTION OF IMPORTANT COM-
PONENTS
[1]
DOOR OPEN MECHANISM.....................
Sharp R-380LS 1 – 1
R380L(W)
Service Manual
CHAPTER 1. BEFORE SERVICING
GENERAL IMPORTANT INFORMATION
This Manual has been prepared to provide Sharp Corp. Service engineers with Operation and Service Information.
It is recommended that service engineers carefully study the entire text of this manual, so they will be qualified to render satisfactory customer ser-
vice.
CAUTION MICROWAVE RADIATION
DO NOT BECOME EXPOSED TO RADIATION FROM THE MICROWAVE GENERATOR
2 – 1
R380L(W)
Service Manual
CHAPTER 2. WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of producing very high voltage and current, contact with any part of the high voltage circuit will result in
electrocution. High voltage capacitor, Power transformer, Magnetron, High voltage rectifier assembly, High voltage harness and High voltage fuse.
REMEMBER TO CHECK 3D
1) Disconnect the supply.
2) Door opened, and wedged open.
3
3 – 1
R380L(W)
Service Manual
CHAPTER 3. PRODUCT SPECIFICATIONS
ITEM
DESCRIPTION
Power Requirements
230 - 240 Volts
50 Hertz
Single phase, 3 wire earthed
Power Consumption
1.67 k W
Power Output
1200 watts nominal of RF microwave energy (IEC Test Procedure)
Operating frequency 2450 MHz
Case Dimensions
Width 520 mm
Height 310 mmincluding foot
Depth 440 mm
Turntable Diameter
320 mm
Control Complement
Touch Control System
Clock (1:00 - 12:59)
Tim
4 – 1
R380L(W)
Service Manual
CHAPTER 4. APPEARANCE VIEW
OVEN
1. Door open button
2. Door safety latches
3. Removable turntable support
4. Removable turntable tray
5. Oven lamp
6. See through door
7. Ventilation openings
8. Touch control panel
9. Liquid crystal display
10. Coupling
11. Wave guide cover
12. Power supply cord
13. Door hinges
14. Door seal and sealing surfaces
TOUCH CONTROL PANEL
1. HEALTHY MENUS PADS
Press to select “Healthy Me
5 – 1
R380L(W)
Service Manual
CHAPTER 5. OPERATION SEQUENCE
[1] OFF CONDITION
Closing the door activates all door interlock switches (1st. latch switch
and 2nd. interlock relay control switch).
MPORTANT
When the oven door is closed, the monitor switch contacts (COM-NC)
must be open. When the microwave oven is plugged in a wall outlet,
rated voltage is supplied to the noise filter and the control unit.
5 – 2
2. Heat potatoes. Moisture and humidity is emitted rapidly. You can
smell the aroma as it cooks.;
3. Sensor detects moisture and humidity and calculates cooking time
and variable power.
1. Cooking Sequence.
1. 1.Operate the oven in sensor cooking mode by referring to the
operation manual.
NOTE: The oven should not be operated on SENSOR immediately
after plugging in the unit. Wait two minutes before cooking on
SENSOR.
2. The coil of shut-of
6 – 1
R380L(W)
Service Manual
CHAPTER 6. FUNCTION OF IMPORTANT COMPONENTS
[1] DOOR OPEN MECHANISM
The door is opened by pushing the open button on the control panel,
refer to the Figure D-1.When the open button is pushed, the open but-
ton pushes up the switch lever, and then the switch lever pushes up
the latch head. The latch heads are moved upward and released from
latch hook. Now the door will open.
Figure D-1. D
7 – 1
R380L(W)
Service Manual
CHAPTER 7. TROUBLESHOOTING GUIDE
When troubleshooting the microwave oven, it is helpful to follow the
Sequence of Operation in performing the checks. Many of the possible
causes of trouble will require that a specific test be performed. These
tests are given a procedure letter which will be found in the “Test Pro-
cedure”section.
IMPORTANT:
If the oven becomes inoperative because of a blown fuse F10A in the
1st
8 – 1
R380L(W)
Service Manual
CHAPTER 8. TEST PROCEDURES
[1] A: MAGNETRON (MG) TEST
NEVER TOUCH ANY PART IN THE CIRCUIT WITH YOUR HAND OR AN INSULATED TOOL WHILE THE OVEN IS IN OPERATION.
CARRY OUT 3D CHECKS.
Isolate the magnetron from the high voltage circuit by removing all leads connected to the filament terminal.
To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron filament terminals, the m
8 – 2
[2] B: POWER TRANSFORMER TEST
CARRY OUT 3D CHECKS.
Disconnect the leads to the primary winding of the power transformer. Disconnect the filament and secondary winding connections from the rest of the
HV circuitry. Using an ohmmeter, set on a low range, it is possible to check the continuity of all three windings. The following readings should be
obtained:
If the reading obtained are not stated as above, then the power transformer is probab
8 – 3
[5] E: SWITCH TEST
CARRY OUT 3D CHECKS.
Isolate the switch to be tested and using an ohmmeter check between the terminals as described in the following table.
If incorrect readings are obtained, make the necessary switch adjustment or replace the switch.
CARRY OUT 4R CHECKS.
[6] F: TEMPERATURE FUSE TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of the temperature fuse. Then using an ohmmeter, make a continuity test acros
Sharp R-380LS 8 – 4
[10] J: HIGH VOLTAGE FUSE TEST
CARRY OUT 3D CHECKS.
If the high voltage fuse is blown, there could be a short in the high voltage rectifier or the magnetron.
Check them and replace the defective parts and the high voltage fuse.
CARRY OUT 4R CHECKS.
CAUTION: ONLY REPLACE HIGH VOLTAGE FUSE WITH THE CORRECT VALUE REPLACEMENT.
[11] K: TOUCH CONTROL PANEL ASSEMBLY TEST
The touch control panel consists of circuits including semiconductors such a
Sharp R-380LS 8 – 5
[13] M: RELAY TEST
CARRY OUT 3D CHECKS.
Remove the outer case and check voltage between the cabinet side terminal of the relay RY1 and the lower side terminal of the relay RY2 on the
power unit with an A.C. voltmeter. The meter should indicate 230 - 240 volts, if not check oven circuit.
RY1 and RY2 Relay Test
These relays are operated by D.C. voltage
Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operati
8 – 6
2) Place the container on the center of tray in the oven cavity.
3) Close the door.
4) Touch the TIMER/CLOCK pad once, the POWER LEVEL pad twice and the START pad once. And touch the number pads 1 once and the number
pad 4 once. Now, the oven is in the sensor cooking condition, and “AH20”, “SENSOR” and “COOK” will appear in the display.
5) The oven will operate for the first 16 seconds, without generating microwave energy.
When
8 – 7
15)Reconnect all leads removed from components during testing and repairing.
16)Re-install the outer case (cabinet).
17)Reconnect the power supply cord after the outer case is installed. Run the oven and check all functions.
18)Carry out “Water load cooking test” again and ensure that the oven works properly.
Sensor Dummy Resistor Circuit
Plunger
NC
NO
COM
COM
NO
NC
R3
R4
R1
R2
1
2
3
F-1
F-2
F-3
To connector (F)
on Control Unit.
CONNEC
9 – 1
R380L(W)
Service Manual
CHAPTER 9. TOUCH CONTROL PANEL ASSEMBLY
[1] OUTLINE OF TOUCH CONTROL PANEL
The touch control section consists of the following units.
(1) Key Unit
(2) Control Unit (The Control Unit consists of Power Unit and LSI Unit).
The principal functions of these units and the signals communicated among them are explained below.
1. Key Unit
The key unit is composed of a matrix, signals generated in the LSI are sent to the key