Sharp R-380LS Service Manual

Text of Sharp R-380LS Service Manual

CHAPTER 1. BEFORE SERVICING

CHAPTER 2. WARNING TO SERVICE PERSONNEL CHAPTER 3. PRODUCT SPECIFICATIONS CHAPTER 4. APPEARANCE VIEW CHAPTER 5. OPERATION SEQUENCE CHAPTER 6. FUNCTION OF IMPORTANT COMPO- NENTS CHAPTER 7. TROUBLESHOOTING GUIDE CHAPTER 8. TEST PROCEDURES CHAPTER 9. TOUCH CONTROL PANEL ASSEMBLY CHAPTER 10. PRECAUTIONS FOR USING LEAD- FREE SOLDER CHAPTER 11. COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE CHAPTER 12. MICROWAVE MEASUREMENT CHAPTER 13
CHAPTER 1. BEFORE SERVICING CHAPTER 2. WARNING TO SERVICE PERSON- NEL CHAPTER 3. PRODUCT SPECIFICATIONS CHAPTER 4. APPEARANCE VIEW CHAPTER 5. OPERATION SEQUENCE [1] OFF CONDITION........................................ 5-1 [2] MICROWAVE COOKING CONDITION....... 5-1 [3] POWER OUTPUT REDUCTION ................ 5-1 [4] SENSOR COOKING CONDITION.............. 5-1 CHAPTER 6. FUNCTION OF IMPORTANT COM- PONENTS [1] DOOR OPEN MECHANISM.....................

Sharp R-380LS 1 – 1

R380L(W) Service Manual CHAPTER 1. BEFORE SERVICING GENERAL IMPORTANT INFORMATION This Manual has been prepared to provide Sharp Corp. Service engineers with Operation and Service Information. It is recommended that service engineers carefully study the entire text of this manual, so they will be qualified to render satisfactory customer ser- vice. CAUTION MICROWAVE RADIATION DO NOT BECOME EXPOSED TO RADIATION FROM THE MICROWAVE GENERATOR

2 – 1

R380L(W) Service Manual CHAPTER 2. WARNING TO SERVICE PERSONNEL Microwave ovens contain circuitry capable of producing very high voltage and current, contact with any part of the high voltage circuit will result in electrocution. High voltage capacitor, Power transformer, Magnetron, High voltage rectifier assembly, High voltage harness and High voltage fuse. REMEMBER TO CHECK 3D 1) Disconnect the supply. 2) Door opened, and wedged open. 3

3 – 1

R380L(W) Service Manual CHAPTER 3. PRODUCT SPECIFICATIONS ITEM DESCRIPTION Power Requirements 230 - 240 Volts 50 Hertz Single phase, 3 wire earthed Power Consumption 1.67 k W Power Output 1200 watts nominal of RF microwave energy (IEC Test Procedure) Operating frequency 2450 MHz Case Dimensions Width 520 mm Height 310 mmincluding foot Depth 440 mm Turntable Diameter 320 mm Control Complement Touch Control System Clock (1:00 - 12:59) Tim

4 – 1

R380L(W) Service Manual CHAPTER 4. APPEARANCE VIEW OVEN 1. Door open button 2. Door safety latches 3. Removable turntable support 4. Removable turntable tray 5. Oven lamp 6. See through door 7. Ventilation openings 8. Touch control panel 9. Liquid crystal display 10. Coupling 11. Wave guide cover 12. Power supply cord 13. Door hinges 14. Door seal and sealing surfaces TOUCH CONTROL PANEL 1. HEALTHY MENUS PADS Press to select “Healthy Me

5 – 1

R380L(W) Service Manual CHAPTER 5. OPERATION SEQUENCE [1] OFF CONDITION Closing the door activates all door interlock switches (1st. latch switch and 2nd. interlock relay control switch). MPORTANT When the oven door is closed, the monitor switch contacts (COM-NC) must be open. When the microwave oven is plugged in a wall outlet, rated voltage is supplied to the noise filter and the control unit.

5 – 2

2. Heat potatoes. Moisture and humidity is emitted rapidly. You can smell the aroma as it cooks.; 3. Sensor detects moisture and humidity and calculates cooking time and variable power. 1. Cooking Sequence. 1. 1.Operate the oven in sensor cooking mode by referring to the operation manual. NOTE: The oven should not be operated on SENSOR immediately after plugging in the unit. Wait two minutes before cooking on SENSOR. 2. The coil of shut-of

6 – 1

R380L(W) Service Manual CHAPTER 6. FUNCTION OF IMPORTANT COMPONENTS [1] DOOR OPEN MECHANISM The door is opened by pushing the open button on the control panel, refer to the Figure D-1.When the open button is pushed, the open but- ton pushes up the switch lever, and then the switch lever pushes up the latch head. The latch heads are moved upward and released from latch hook. Now the door will open. Figure D-1. D

7 – 1

R380L(W) Service Manual CHAPTER 7. TROUBLESHOOTING GUIDE When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the “Test Pro- cedure”section. IMPORTANT: If the oven becomes inoperative because of a blown fuse F10A in the 1st

8 – 1

R380L(W) Service Manual CHAPTER 8. TEST PROCEDURES [1] A: MAGNETRON (MG) TEST NEVER TOUCH ANY PART IN THE CIRCUIT WITH YOUR HAND OR AN INSULATED TOOL WHILE THE OVEN IS IN OPERATION. CARRY OUT 3D CHECKS. Isolate the magnetron from the high voltage circuit by removing all leads connected to the filament terminal. To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron filament terminals, the m

8 – 2

[2] B: POWER TRANSFORMER TEST CARRY OUT 3D CHECKS. Disconnect the leads to the primary winding of the power transformer. Disconnect the filament and secondary winding connections from the rest of the HV circuitry. Using an ohmmeter, set on a low range, it is possible to check the continuity of all three windings. The following readings should be obtained: If the reading obtained are not stated as above, then the power transformer is probab

8 – 3

[5] E: SWITCH TEST CARRY OUT 3D CHECKS. Isolate the switch to be tested and using an ohmmeter check between the terminals as described in the following table. If incorrect readings are obtained, make the necessary switch adjustment or replace the switch. CARRY OUT 4R CHECKS. [6] F: TEMPERATURE FUSE TEST CARRY OUT 3D CHECKS. Disconnect the leads from the terminals of the temperature fuse. Then using an ohmmeter, make a continuity test acros

Sharp R-380LS 8 – 4

[10] J: HIGH VOLTAGE FUSE TEST CARRY OUT 3D CHECKS. If the high voltage fuse is blown, there could be a short in the high voltage rectifier or the magnetron. Check them and replace the defective parts and the high voltage fuse. CARRY OUT 4R CHECKS. CAUTION: ONLY REPLACE HIGH VOLTAGE FUSE WITH THE CORRECT VALUE REPLACEMENT. [11] K: TOUCH CONTROL PANEL ASSEMBLY TEST The touch control panel consists of circuits including semiconductors such a

Sharp R-380LS 8 – 5

[13] M: RELAY TEST CARRY OUT 3D CHECKS. Remove the outer case and check voltage between the cabinet side terminal of the relay RY1 and the lower side terminal of the relay RY2 on the power unit with an A.C. voltmeter. The meter should indicate 230 - 240 volts, if not check oven circuit. RY1 and RY2 Relay Test These relays are operated by D.C. voltage Check voltage at the relay coil with a D.C. voltmeter during the microwave cooking operati

8 – 6

2) Place the container on the center of tray in the oven cavity. 3) Close the door. 4) Touch the TIMER/CLOCK pad once, the POWER LEVEL pad twice and the START pad once. And touch the number pads 1 once and the number pad 4 once. Now, the oven is in the sensor cooking condition, and “AH20”, “SENSOR” and “COOK” will appear in the display. 5) The oven will operate for the first 16 seconds, without generating microwave energy. When

8 – 7

15)Reconnect all leads removed from components during testing and repairing. 16)Re-install the outer case (cabinet). 17)Reconnect the power supply cord after the outer case is installed. Run the oven and check all functions. 18)Carry out “Water load cooking test” again and ensure that the oven works properly. Sensor Dummy Resistor Circuit Plunger NC NO COM COM NO NC R3 R4 R1 R2 1 2 3 F-1 F-2 F-3 To connector (F) on Control Unit. CONNEC

9 – 1

R380L(W) Service Manual CHAPTER 9. TOUCH CONTROL PANEL ASSEMBLY [1] OUTLINE OF TOUCH CONTROL PANEL The touch control section consists of the following units. (1) Key Unit (2) Control Unit (The Control Unit consists of Power Unit and LSI Unit). The principal functions of these units and the signals communicated among them are explained below. 1. Key Unit The key unit is composed of a matrix, signals generated in the LSI are sent to the key

Sharp Microwave Oven Owners Instructions: