In the interest of user-safety the oven should be restored to its original

condition and only parts identical to those specified should be used. WARNING TO SERVICE PERSONNEL: Microwave ovens con- tain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Recti- fier A

PRECAUTIONS TO BE OBSERVED BEFORE AND

DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY (a) Do not operate or allow the oven to be operated with the door open. (b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of pro- ducing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (Example) High Voltage Capacitor, High Voltage Power Trans- former, Magnetron, High Voltage Rectifier Assem- bly, High Voltage Harness etc.. Read the Service Manual carefully and follow all instructions. Before Servicing 1. Disconnect t

MICROWAVE MEASUREMENT PROCEDURE

A. Requirements: 1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/cm2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm2 at any point 5cm or more from the external surface of the oven. 2) Safety i

SHARP ELECTRONICS CORPORATION

SHARP PLAZA, MAHWAH, NEW JERSEY 07430-2135 SERVICE MANUAL MICROWAVE OVEN R-420CK/ R-420CW FOREWORD This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service Information for the SHARP MICROWAVE OVEN, R-420CK, R-420CW. It is recommended that service personnel carefully study the entire text of this manual so that they will be qualified to render satisfactory c

Sharp R-420CK 120 Volts / 13.3 Amperes/1550Watts

60 Hertz Single phase, 3 wire grounded Power Output 1100 watts (IEC-705 TEST PROCEDURE) Operating frequency of 2450MHz Case Dimensions Width 21-11/16" Height 12-3/8" Depth 17-3/8" Cooking Cavity Dimensions Width 15" 1.4 Cubic Feet Height 9-7/16" Depth 16-3/4" Tray Size 14-1/8" Diameter Control Complement Touch Control System Clock ( 1:00 - 12:59 ) Timer

a qualified electrician and have it replaced with a properly grounded

three-pronged wall receptacle or have a grounding adapter properly grounded and polarized. If the extension cord must be used, it should be a 3-wire, 15 amp. or higher rated cord. Do not drape over a countertop or table where it can be pulled on by children or tripped over accidentally. CAUTION: DO NOT UNDER ANY CIRCUMSTANCES CUT OR RE- MOVE THE ROUND GROUNDING PRONG FR

DESCRIPTION OF OPERATING SEQUENCE

The following is a description of component functions during oven operation. OFF CONDITION Closing the door activates the door sensing switch and secondary interlock switch. (In this condition, the monitor switch contacts are opened.) When oven is plugged in, 120 volts A.C. is supplied to the control unit. (Figure O-1). 1. The display will show flashing "88:88". To set any program or set the clo

Sharp R-420CK SENSOR COOKING CONDITION

Using the SENSOR function, food is cooked without figuring time, power level or quantity. When the oven senses enough steam from the food, it relays the information to its microprocessor which will calculate the remaining cooking time and power level needed for best results. When the food is cooked, water vapor is developed. The sensor "senses" the vapour and its resistance increase gradually. When the resist

Figure O-2 Oven Schematic - Cooking Condition

Figure O-1 Oven Schematic - Off Condition SCHEMATIC NOTE: CONDITION OF OVEN 1. Door Closed 2. CLOCK APPEARS ON DISPLAY 120V AC 60 Hz OVEN LAMP TURN- TABLE MOTOR FAN MOTOR MONITOR SWITCH H.V. RECTIFIER MAGNETRON SECONDARY INTERLOCK SWITCH TTM OL FM CAVITY TEMP. FUSE A1 A2 COM. COM. COM. N.O. N.C. N.O. DOOR SENSING SWITCH (RY-1) (RY-2) CONTROL UNIT PRIMARY INTERLOCK RELAY B1 B2 GRN POWER TRANSF

DESCRIPTION AND FUNCTION OF COMPONENTS

DOOR OPEN MECHANISM The door is opened by pushing the open button on the control panel, refer to the Figure D-1. When the open button is pushed, the open button pushes up the switch lever, and then the switch lever pushes up the latch head. The latch heads are moved upward and released from latch hook. Now the door will open. Figure D-1. Door Open Mechanism DOOR SENSING AND SECONDARY INTERLOCK SWITCH

Never touch any part in the circuit with your hand or an uninsulated tool while the power supply is connected.

When troubleshooting the microwave oven, it is helpful to follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the "Test Procedure "section. IMPORTANT:

MAGNETRON ASSEMBLY TEST

1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. Home fuse or circuit breaker blows when power cord is plugged into wall receptacle Monitor fuse blows when power cord is plugged into wall receptacle. All letters and indicators do not appear in display when power cord is first plugged into wall outlet. Display does not operat

POWER TRANSFORMER TEST

1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Disconnect the primary input terminals and measure the resistance of the transformer with an ohmmeter. Check for continuity of the coils with an ohmmeter. On the R x 1 scale, the resistance of the primary coil should be less than 1 ohm and the resistance of the high voltage

Sharp R-420CK 1. Disconnect the power supply cord, and then remove outer case.

2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the capacitor is open, no high voltage will be available to the magnetron. Disconnect input leads and check for short or open between the terminals using an ohmmeter. Checking with a high ohm scale, if the high voltage capacitor is normal, the meter
1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. Before performing this test, make sure that the secondary interlock switch and the primary interlock relay are operating properly, according to the above Switch Test Procedure. Disconnect the wire lead from the monitor switch (COM) terminal. Check the

BLOWN MONITOR FUSE TEST

TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST 1. Disconnect the power supply cord, and then remove outer case. 2. Open the door and block it open. 3. Discharge high voltage capacitor. 4. If the monitor fuse is blown when the door is opened, check the primary interlock relay, secondary interlock switch and monitor switch according to the "TEST PROCEDURE" for those switches before replacing the blown monitor fus

The following symptoms indicate a defective key unit.

a) When touching the pads, a certain pad produces no signal at all. b) When touching a number pad, two figures or more are displayed. c) When touching the pads, sometimes a pad produces no signal. If the Key unit is defective. 1) Disconnect the power supply cord, and then remove outer case. 2) Open the door and block it open. 3) Discharge high voltage capacitor. 4) Replace the Key uni

Sharp R-420CK WARNING : The oven should be fully assembled before following procedure.

(1) Place one cup of water in the center of the turntable tray in the oven cavity. (2) Close the door, touch the " steaks / chops " pad once. (3) The oven is in Compu Defrost cooking condition. (4) The oven will operate as follows 1ST STAGE 2ND STAGE WEIGHT LEVEL TIME LEVEL TIME 0.5lb 60% 27sec. 40% 17sec. 6. Re-install the outer case (cabinet). 7. Reconnect the pow

(5) If improper operation is indicated, the control unit is probably defective and should be checked.

TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST To protect the electronic circuits, this model is provided with a fine foil pattern added to the primary on the PWB, this foil pattern acts as a fuse. 1. Foil pattern check and repairs. 1) Disconnect the power supply cord, and then remove outer case. 2) Open the door and block it open. 3) D

Sharp Microwave Oven Owners Instructions: