Sharp R-430BK Service Manual

Text of Sharp R-430BK Service Manual

MICROWAVE OVEN MODELS

R-430BK/R-430BW / R-430BD In the interest of user-safety the oven is to be restored to its original condition and only the parts identical to those specified should be used. R-430BW WARNING TO SERVICE PERSONNEL: Microwave ovens contain circuitry capable of producing very high voltage and current. Contact with the following parts may result in a severe, possibly

Do not operate or allow the oven to be operated with the door open.

Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) Interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or

Sharp R-430BK This manual has been prepared to provide Sharp

Electronics Corporation personnel with complete operation and service information for Sharp microwave oven models R-430BWR=430BW/R=430BD. It is recommended that service personnel carefully study the entire text of this manual so they will be qualified to render satisfactory customer service. Check interlock switches and the door seal carefu

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of producing very high voltage and current. Con- tact with following parts may result in a severe, possibly fatal, electrical shock. (EXAMPLE) High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness etc.. Read the Service Manual carefully and follow all instructions. Danger High Voltage Before Servi

Single phase, 3 wire grounded

Power Output 1100 watts (IEC-705 Test Procedure) Operating frequency of 2450 MHz Case Dimensions Width 21 ll&” Height 1231;’ (including feet) Depth 1731~” Cooking Cavity 1.3 Cu.Ft. Width 15” Height 817/& Depth 1631;’ Tray Size 141/i’ Diameter Control Complement Touch Control System Clock (I:00 - 12:59

Key Unit Layout

a. Indicators. b. Lighted digital display. c. Custom Help. Features user friendly communications during cooking procedure. d. SENSOR COOKING pads. Cooking time is determined by AH Sensor e. Minute Plus pad. Touch to start oven or Touch to cook for 1 minute at 100% power or to increase cook- ing time. f. Compu Cook pad. Touch to cook certain foods. g, Compu Defrost pad. Touch to defrost certain foods. h. Number select

The following is a description

during oven ope ration. OPERATION DESCRIPTION OF OPERATING SEQUENCE of compon Sensor Cooking Condition ent functions When using the REHEAT function, the foods are cooked without figuring time, power level or quantity. When the oven senses enough steam from the food, it relays the information to its microprocessor which will calculate the remaining cooking time and the power level needed for 1 best results. When the food is co

the microwave oven, it is helpful to follow the sequence of operation in performing the checks.

Many of the possible causes of trouble will require that a specific test be performed. These tests are given a procedure letter which will be found in the “Test Procedure” section. Before replacing a blown monitor fuse, test the door sensing switch, primary interlock relay, sec- ondary interlock switch and monitor

Sharp R-430BK Touch Control Panel Assembly Test

The touch control panel consists of circuits including semiconductors such as LSI, ICs, etc. There- fore, unlike conventional microwave ovens, proper maintenance can not be performed with only a voltmeter and ohmmeter. In this service manual, the touch control panel assembly is divided into two control units, Control Unit and Key Unit. Troubleshooting by unit repl

Sharp R-430BK Touch Control Panel Assembly Test (Confinued)

When testing is completed, 1. Disconnect the power supply cord, and then remove outer case cabinet. 2. Open the door and block it open. 3. Discharge the high voltage capacitor. 4. Reconnect all leads removed from components during testing. 5. Re-install the outercase cabinet. 6. Reconnect the power supply cord after installing the outer

Procedures to be taken when the foil pattern of the printed wiring board (PWB)

is open 5. Make a visual inspection of the varistor burn damage and test the transformer with an ohm- meter for the presence of layer short-circuit (check the primary coil resistance which is approximately 210 Q * 15%). If any abnormal condition is detected, replace the defective part(s) m m 0 6. Recon

Compu Defrost Test

1. Place one cup of water in the center of the turntable tray in the oven cavity. 2. Close the door, touch the “COMPU DEFROST” pad once and touch the number pad “I”, and touch the number pad “5”. Then touch the “START” pad. 3. The oven is in “COMPU DEFROST’ cooking mode. 4. The oven will operate as follows: Weight 1st Stage 2nd Stage 3rd Stage 4

AH Sensor Test

Checking the initial sensor cooking condition 1. The oven should be plugged in at least five minutes before sensor cooking. 2. Room temperature should not exceed 95” F (35” C). 3. The unit should not be installed in any areas where heat and steam are generated. The unit should not be installed, for example, next to a conventional surface unit. 4. Exhaust vents are provided on the bottom of

Checking the Control Unit (Confinued)

6. Disconnect the wire leads to the primary of power transformer. 7. Ensure that these leads remain isolated from other components and oven chassis by using insu- lated tape. 8. After that procedure, reconnect the power supply cord. 9. Check the sensor cook operation proceed as follows: A. Touch REHEAT pad once and touch Start pad. B. The control panel is in th

OUTLINE OF TOUCH CONTROL PANEL

The touch control section consists of the following units as shown in the touch control panel circuit: (1) Key Unit (2) Control Unit (The Control Unit consist of Power Unit and LSI Unit) The principal functions of these units and their related signals are explained below. Key Unit The key unit is composed of a matrix. Signals generated in the LSI are sent to the key unit through P20 - P27. When a key pad is touch

The I/O signals of the LSI (IZA866DR) is detailed in the following table.

( Pin No. 1 Signal 1 I/O 1 Description 1 2 3 4 / 5 I 6 7 8 9 10 , 11 12 13 14 15 16 17 18 19 20 21 AN8 IN AN9 IN AN10 IN Signal coming from touch-key. When either G-12 line on key matrix is touched, a corresponding signal out of P20-P27 will be input into AN8. When no key is touched, the signal is held at “H” level. Signal similar to AN8. When either Gil l

Signal to sound Buzzer (2.0 kHz).

0.1 sec. B: completion sound 23 P31 OUT Terminal not used. 24 P32 OUT Common data signal: COM5. Connected to LCD signal COM5 (Pin No. 37). Segment data signal. Connected to LCD. The relation between signals are as follows: LSI signal (Pin No.) LCD (Pin No.) P33 (25) ............ SEG32 (38) P34 (26) ............ SEG33 (39) P35 (27) ............ SEG34 (40) P36

Sharp Microwave Oven Owners Instructions: