Sharp R-880F Service Manual
Text of Sharp R-880F Service Manual
Sharp R-880F TABLE OF CONTENTS
Page
CAUTION, MICROWAVE RADIATION.................................................................................................... 1
WARNING.................................................................................................................................................1
PRODUCT SPECIFICATIONS ................................................................................................................ 2
GENE
GENERAL IMPORTANT INFORMATION
This Manual has been prepared to provide Sharp Corp. Service
engineers with Operation and Service Information.
It is recommended that service engineers carefully study the entire
text of this manual, so they will be qualified to render satisfactory
customer service.
CAUTION
MICROWAVE RADIATION
Service engineers should not be exposed to the microwave
THIS APPLIANCE MUST BE EARTHED
IMPORTANT
THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
GREEN-AND-YELLOW
: EARTH
BLUE
: NEUTRAL
BROWN
: LIVE
PRODUCT DESCRIPTION
SPECIFICATION
ITEM
DESCRIPTION
Power Requirements
230 - 240 Volts
50 Hertz
Single phase, 3 wire earthed
Power Consumption
Microwave cooking
1.6 kW
Top Heater mode
1.3 kW
Grill cooking
Bottom heater mode
0.9 kW
Top and Bottom
Sharp R-880F 1. TOP HEATER SYMBOL
The symbol will light when the top heater is in use.
2. BOTTOM HEATER SYMBOL
The symbol will light when the bottom heater is in use.
3. CONVECTION SYMBOL
The symbol will light during convection cooking.
A. HELP PAD
Press to select auto start, information guide on/off, child lock,
demonstration modes or info on pads.
Press to obtain cooking information.
B. MULTI COOK PAD
Press to select Multi Cook mode.
C. CO
Closing the door activates the 1st. latch switch and 2nd.
interlock relay control switch.
IMPORTANT:
When the oven door is closed, the contacts COM-NC
of the monitor switch must be open. When the mi-
crowave oven is plugged in a wall outlet (230 - 240V
50Hz), the line voltage is supplied to the noise filter
and the control unit.
Figure O-1 on page 33
1. The oven display will show " SHARP MICRO- WAVE
OVEN " .
2.
1. The relay RY3 + RY5 + RY6 are energized.
2. The numbers of the digital read-out start the count
down to zero.
3. Then the top heaters, turntable motor, oven lamp and
fan motor are energized.
4. Now, the food is grilled by the top heaters.
5. Upon completion of the selected cooking time, audible
signal sounds and the contacts of relays RY3 + RY6
are opened, then the top heaters, turntable motor and
oven lamp are de-energized. But the relay RY
1. In case of Automatic operations, the limitations of
power output are not carried out.
2. In case that the STOP/CLEAR pad is pressed or the
oven door is opened during cooking, the limitations of
power output are carried out after the total cooking time
beyond the specified cooking time.
3. In case of the two or more same cooking modes are
carried out, the limitations of power output are carried
out after the total cooking time beyond
Sharp R-880F 4. Upon completion of the cooking time, the audible
signal will sound, and oven lamp, turntable motor,
cooling fan motor and convection motor are de-ener-
gized. At the end of the convection cycle, if the cavity
air temperature is above 120˚C, the circuit to (RY5) will
be m
DOOR OPEN MECHANISM
The door can be opened by pushing the open button on the
control panel. When the open button is pushed, the switch
lever is moved upward, operating the latch head. The latch
head is moved upward and released from the latch hook.
Now, the door can be opened.
Figure D-1. Door Open Mechanism
FUNCTION OF IMPORTANT COMPONENTS
judgment that there is a fire in the oven cavity and will
switch off the relays to the power transformer,
The noise filter assembly prevents radio frequency inter-
ference that might flow back in the power circuit.
TOP HEATERS
The top heaters are located on the top of the oven cavity
assembly. The top heaters send out heat to grill foods.
BOTTOM HEATER
The bottom heater is located on the floor of the oven cavity
assembly. The bottom heater sends out heat to grill foods.
ONVECTION COOKING SYSTEM
This oven is designed with a hot air heat
When troubleshooting the microwave oven, it is helpful to
follow the Sequence of Operation in performing the checks.
Many of the possible causes of trouble will require that a
specific test be performed. These tests are given a proce-
dure letter which will be found in the “Test Procedure”
section.
IMPORTANT: If the oven becomes inoperative because
of a blown fuse F10A in the 1st. latch
switch - 2nd. interlock relay(RY2)- monitor
switch ci
Fuse 15A blows when power cord is plugged into wall outlet.
Fuse F10A blows when the door is opened.
Home fuse blows when power cord is plugged into wall outlet.
"SHARP MICRO- OVEN" does not appear in display when power cord is
plugged into wall outlet.
Display does not operate properly when STOP/CLEAR pad is pressed.
Oven does not start when the INSTANT COOK/ START pad is pressed.
(Display operates.)
Oven lamp does not light. (Turntable motor
CARRY OUT 3D CHECKS.
Isolate the magnetron from high voltage circuit by removing all leads connected to filament terminal.
To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron
filament terminals, the meter should show a reading of less than 1 ohm.
To test for short filament to anode condition, connect ohmmeter between one of the fil
Initial temperature .................................................................................................. T1 = 11°C
Temperature after (47 + 3) = 50 sec ...................................................................... T2 = 21°C
Temperature difference Cold-Warm....................................................................... ∆T1 = 10C
Measured output power
The equation is “P = 90 x ∆T” .........................
CARRY OUT 3D CHECKS. Isolate the switch to be tested and using an ohmmeter check between the terminals as described in
the following table.
Table: Terminal Connection of Switch
Plunger Operation
COM to NO
COM to NC
Released
Open circuit
Short circuit
Depressed
Short circuit
Open circuit
COM; Common terminal,
NO;
Normally open terminal
NC;
Normally close terminal
If incorrect reading
CARRY OUT 3D CHECKS. Disconnect the leads from the motor. Using an ohmmeter, check the resistance between the two
terminals as described in the table below.
Table: Resistance of Motor
Motors
Resistance
Fan motor
Approximately 290 Ω
Turntable motor
Approximately 15 kΩ
Convection motor
Approximately 293 Ω
If incorrect readings are obtained, replace the motor.
CARRY OUT 4R CHECKS.
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
H
BLOWN FUSE
Sharp R-880F 1. CARRY OUT 3D CHECKS.
2. Disconnect connector-D from the control unit. Measure the resistance of the thermistor with an
ohmmeter. Connect the ohmmeter leads to Pin No’s D1 and D3.
Room Temperature
Resistance
68˚F(20˚C) - 86˚F(30˚C)
Approx. 293kΩ - 184KΩ
3. If the meter does not indicate above resistance, replace the thermistor
4. CARRY OUT 4R CHECKS.
The touch contro
momentary contact. If the control unit responds by clearing with a beep the key unit is faulty and must
be replaced. If the control unit does not respond, it is a faulty and must be replaced. If a specific pad
does not respond, the above method may be used (after clearing the control unit) to determine if the
control unit or key pad is at fault.
CARRY OUT 3D CHECKS.
Remove the outer case and che