Sharp R-880F Service Manual

Text of Sharp R-880F Service Manual

Sharp R-880F TABLE OF CONTENTS

Page CAUTION, MICROWAVE RADIATION.................................................................................................... 1 WARNING.................................................................................................................................................1 PRODUCT SPECIFICATIONS ................................................................................................................ 2 GENE

GENERAL IMPORTANT INFORMATION

This Manual has been prepared to provide Sharp Corp. Service engineers with Operation and Service Information. It is recommended that service engineers carefully study the entire text of this manual, so they will be qualified to render satisfactory customer service. CAUTION MICROWAVE RADIATION Service engineers should not be exposed to the microwave

THIS APPLIANCE MUST BE EARTHED

IMPORTANT THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE: GREEN-AND-YELLOW : EARTH BLUE : NEUTRAL BROWN : LIVE PRODUCT DESCRIPTION SPECIFICATION ITEM DESCRIPTION Power Requirements 230 - 240 Volts 50 Hertz Single phase, 3 wire earthed Power Consumption Microwave cooking 1.6 kW Top Heater mode 1.3 kW Grill cooking Bottom heater mode 0.9 kW Top and Bottom

Sharp R-880F 1. TOP HEATER SYMBOL

The symbol will light when the top heater is in use. 2. BOTTOM HEATER SYMBOL The symbol will light when the bottom heater is in use. 3. CONVECTION SYMBOL The symbol will light during convection cooking. A. HELP PAD Press to select auto start, information guide on/off, child lock, demonstration modes or info on pads. Press to obtain cooking information. B. MULTI COOK PAD Press to select Multi Cook mode. C. CO

Closing the door activates the 1st. latch switch and 2nd.

interlock relay control switch. IMPORTANT: When the oven door is closed, the contacts COM-NC of the monitor switch must be open. When the mi- crowave oven is plugged in a wall outlet (230 - 240V 50Hz), the line voltage is supplied to the noise filter and the control unit. Figure O-1 on page 33 1. The oven display will show " SHARP MICRO- WAVE OVEN " . 2.

1. The relay RY3 + RY5 + RY6 are energized.

2. The numbers of the digital read-out start the count down to zero. 3. Then the top heaters, turntable motor, oven lamp and fan motor are energized. 4. Now, the food is grilled by the top heaters. 5. Upon completion of the selected cooking time, audible signal sounds and the contacts of relays RY3 + RY6 are opened, then the top heaters, turntable motor and oven lamp are de-energized. But the relay RY

1. In case of Automatic operations, the limitations of

power output are not carried out. 2. In case that the STOP/CLEAR pad is pressed or the oven door is opened during cooking, the limitations of power output are carried out after the total cooking time beyond the specified cooking time. 3. In case of the two or more same cooking modes are carried out, the limitations of power output are carried out after the total cooking time beyond

Sharp R-880F 4. Upon completion of the cooking time, the audible

signal will sound, and oven lamp, turntable motor, cooling fan motor and convection motor are de-ener- gized. At the end of the convection cycle, if the cavity air temperature is above 120˚C, the circuit to (RY5) will be m

DOOR OPEN MECHANISM

The door can be opened by pushing the open button on the control panel. When the open button is pushed, the switch lever is moved upward, operating the latch head. The latch head is moved upward and released from the latch hook. Now, the door can be opened. Figure D-1. Door Open Mechanism FUNCTION OF IMPORTANT COMPONENTS judgment that there is a fire in the oven cavity and will switch off the relays to the power transformer,

The noise filter assembly prevents radio frequency inter-

ference that might flow back in the power circuit. TOP HEATERS The top heaters are located on the top of the oven cavity assembly. The top heaters send out heat to grill foods. BOTTOM HEATER The bottom heater is located on the floor of the oven cavity assembly. The bottom heater sends out heat to grill foods. ONVECTION COOKING SYSTEM This oven is designed with a hot air heat

When troubleshooting the microwave oven, it is helpful to

follow the Sequence of Operation in performing the checks. Many of the possible causes of trouble will require that a specific test be performed. These tests are given a proce- dure letter which will be found in the “Test Procedure” section. IMPORTANT: If the oven becomes inoperative because of a blown fuse F10A in the 1st. latch switch - 2nd. interlock relay(RY2)- monitor switch ci

Fuse 15A blows when power cord is plugged into wall outlet.

Fuse F10A blows when the door is opened. Home fuse blows when power cord is plugged into wall outlet. "SHARP MICRO- OVEN" does not appear in display when power cord is plugged into wall outlet. Display does not operate properly when STOP/CLEAR pad is pressed. Oven does not start when the INSTANT COOK/ START pad is pressed. (Display operates.) Oven lamp does not light. (Turntable motor

CARRY OUT 3D CHECKS.

Isolate the magnetron from high voltage circuit by removing all leads connected to filament terminal. To test for an open circuit filament use an ohmmeter to make a continuity test between the magnetron filament terminals, the meter should show a reading of less than 1 ohm. To test for short filament to anode condition, connect ohmmeter between one of the fil

Initial temperature .................................................................................................. T1 = 11°C

Temperature after (47 + 3) = 50 sec ...................................................................... T2 = 21°C Temperature difference Cold-Warm....................................................................... ∆T1 = 10C Measured output power The equation is “P = 90 x ∆T” .........................
CARRY OUT 3D CHECKS. Isolate the switch to be tested and using an ohmmeter check between the terminals as described in the following table. Table: Terminal Connection of Switch Plunger Operation COM to NO COM to NC Released Open circuit Short circuit Depressed Short circuit Open circuit COM; Common terminal, NO; Normally open terminal NC; Normally close terminal If incorrect reading
CARRY OUT 3D CHECKS. Disconnect the leads from the motor. Using an ohmmeter, check the resistance between the two terminals as described in the table below. Table: Resistance of Motor Motors Resistance Fan motor Approximately 290 Ω Turntable motor Approximately 15 kΩ Convection motor Approximately 293 Ω If incorrect readings are obtained, replace the motor. CARRY OUT 4R CHECKS. TEST PROCEDURES PROCEDURE LETTER COMPONENT TEST H BLOWN FUSE

Sharp R-880F 1. CARRY OUT 3D CHECKS.

2. Disconnect connector-D from the control unit. Measure the resistance of the thermistor with an ohmmeter. Connect the ohmmeter leads to Pin No’s D1 and D3. Room Temperature Resistance 68˚F(20˚C) - 86˚F(30˚C) Approx. 293kΩ - 184KΩ 3. If the meter does not indicate above resistance, replace the thermistor 4. CARRY OUT 4R CHECKS. The touch contro

momentary contact. If the control unit responds by clearing with a beep the key unit is faulty and must

be replaced. If the control unit does not respond, it is a faulty and must be replaced. If a specific pad does not respond, the above method may be used (after clearing the control unit) to determine if the control unit or key pad is at fault. CARRY OUT 3D CHECKS. Remove the outer case and che

Sharp Microwave Oven Owners Instructions: