Roland CG-8 Supplementary Manual

Text of Roland CG-8 Supplementary Manual

Date: May 1, 2005

Symbol Item Setting range n: MIDI channel 0H-FH (ch.1 - ch.16) vv: Control value, 00H-7FH (0 - 127) Velocity value, etc. (Only when the item is the Note On Velocity, the setting range is “01H-7FH (1 - 127)”.) kk: Note number 00H-7FH (0 - 127) xx: Switch on and off 00H-3FH (0 - 63): OFF 40H-7FH (64 - 127): ON 1. Receiving data ■Channel Voice Message ●Note On Status Second Third 9nH

❍Balance (Controller Number 8)

Status Second Third BnH 08H vvH * OFF by default. ❍Panpot (Controller Number 10) Status Second Third BnH 0AH vvH * OFF by default. ❍Expression (Controller Number 11) Status Second Third BnH 0BH vvH * By default, controls the fade. 100% black: vv = 0 Normal output: vv = 64 100% white: vv = 127 ❍Effect control1 (Controller Number 12) Status Second Third BnH 0CH vvH * OFF by default. ❍Effect contr

❍Effect depth 4 (Controller Number 94)

Status Second Third BnH 5EH vvH * By default, controls the depth to which modulation is applied to Speed. ❍Effect depth 5 (Controller Number 95) Status Second Third BnH 5FH vvH * OFF by default. ❍Data Increment (Controller Number 96) Status Second Third BnH 60H vvH * By default, increments the value. The value (vv) is ignored. ❍Data Decrement (Controller Number 97) Status Second Third BnH

●Data set 1 (DT1)

Data set 1 is the message that transmits the real data. It is used when you set the unit by transmitting the data. Status Data Status F0H 41H, dev, 00H, F7H 00H, 0EH, 12H, aaH, bbH, ccH, ddH, ..., eeH, sum Explanation of the byte F0H Exclusive status 41H ID number (Roland) dev Device ID (dev:00H-1FH, default setting is 10H.) 00H Model ID First Byte (CG-8) 00H Model ID Second Byte (CG-8) 0EH Model ID Third Byte (CG-

❍Breath type (Controller Number 2)

Status Second Third BnH 02H vvH * OFF by default. ❍Foot type (Controller Number 4) Status Second Third BnH 04H vvH * OFF by default. ❍Portamento time (Controller Number 5) Status Second Third BnH 05H vvH * By default, transmitted when you select a picture using the panel. For a photo patch: vv = 0-47 For a stamp patch: vv = 0-15 ❍Volume (Controller Number 7) Status Second Third BnH 07H vvH *

❍Sound Controller10 (Controller Number 79)

Status Second Third BnH 4FH vvH * By default, transmitted when you control the parameter Z modulation depth from the panel. ❍General Purpose Controller 5–8 (Controller Number 80–83) Status Second Third BnH 50–53H vvH * OFF by default. ❍Portamento control (Controller Number 84) Status Second Third BnH 54H vvH * OFF by default. ❍Effect depth 2 (Controller Number 92) Status Second

■System Exclusive Message

Status data Status F0H iiH,ddH,...,eeH F7H F0H: Status of the system exclusive message ii = ID number: Manufacturer number (ID number for the System Exclusive message identifying the manufacturer). Roland’s manufacturer ID number is 41H. The ID numbers 7EH and 7FH are used as extensions to the MIDI standard as the universal non-realtime message (7EH) and the universal realtime message (7FH). dd,...,ee = D

3. Parameter address map

3-1. CG-8 (Model ID = 00H 00H 0EH) 3-1-1. System Area 3-1-1-1. System Common Area 3-1-1-2. System Control Area 3-1-1-3. System Control Assign Area Address Parameter Name 00H 00H 00H 00H System (See 3-1-1) 10H 00H 00H 00H Layer (See 3-1-2) Address Parameter Name 00H 00H 00H 00H System Common 00H 00H 01H 00H System Control 00H 00H 02H 00H System Control Assign Address Parameter Name Sys.Ex. Value Meaning of Valu

Roland CG-8 3-1-2. Layer Area

3-1-2-1. Layer Control (PHOTO) Area 3-1-2-2. Layer Control (STAMP) Area Address Parameter Name 10H 00H 00H 00H Layer Control (PHOTO) 10H 00H 01H 00H Layer Control (STAMP) Address Parameter Name Sys.Ex. Value Meaning of Value 10H 00H 00H 00H Bank Number 00H-0FH 10H 00H 00H 01H Program Number 00H-0FH 10H 00H 00H 02H Photo Number 00H-2FH 10H 00H 00H 03H Reserved -- 10H 00H 00H 04H Trigger 00H-01H OFF, ON 10H 00H 00H 05H

Roland CG-8 3-2. V-LINK (Model ID = 00H 51H)

* V-LINK messages are only received, not transmitted. No response will be sent even in answer to Data Request 1. * When V-LINK is off, the V-LINK message is ignored. * Settings that are received during V-LINK is on are not saved. * The tables below show the correspondence between V-LINK parameter names and the CG-8’s parameters, and the default state of V-LINK (the state when only a V-LINK ON messag

3-2-1. System Preference Area

3-2-2. Clip Control Assignment Area 3-2-3. Color Control Assignment Area 3-2-4. Clip Control Preference Area Address Parameter Name Sys.Ex. Value Meaning of Value 10H 00H 00H V-LINK Enabled 00H-01H OFF, ON 10H 00H 01H V-LINK Clip Ctrl Rx MIDI Ch. 00H-0FH 1-16 10H 00H 02H V-LINK Color Ctrl Rx MIDI Ch. -- -- 10H 00H 03H V-LINk Note Message Enabled 00H, 02H OFF, Assignable 10H 00H 04H V-LINK Fast Control En

3-2-5. Color Control Preference Area

3-2-6. Sender Information Area Address Parameter Name Sys.Ex. Value Meaning of Value 10H 40H 00H V-LINK Color Cb Ctrl Polarity 02H Positive&Negative (FIXED) 10H 40H 01H V-LINK Reserved Area 10H 40H 02H V-LINK Color Cr Ctrl Polarity -- 10H 40H 03H V-LINK Reserved Area 10H 40H 04H V-LINK Brightness Ctrl Polarity -- 10H 40H 05H V-LINK Reserved Area 10H 40H 06H V-LINK Output Fade Ctrl Polarity 02H Pos

Roland Switch Owners Instructions:

Device Model Type of Document Pages Size Views Downloads Updated For Device
v-1hd

PDF User Manual (@89CF62), Roland v-1hd Switch (29-08-2026)

68 1203 229 29-08-2026 view all
XS-62S

PDF Manual (@6TF44C), Roland XS-62S Switch (08-09-2026)

35 875 132 08-09-2026 view all
V-160HD

PDF User Manual (@31L84W), Roland V-160HD Switch (17-09-2026)

22 1144 172 17-09-2026 view all
V-40HD

PDF User Guide (@WX9Z99), Roland V-40HD Switch (12-05-2026)

60 10.4 Mb 260 50 12-05-2026 view all
V-1SDI

V-1SDI Owner's manual - O5A1H9

40 512 113 23-09-2026 view all
V-160HD

#7C66X3: V-160HD Switch Startup manual

12 1274 306 29-04-2026 view all