Roland CG-8 Supplementary Manual
Text of Roland CG-8 Supplementary Manual
Date: May 1, 2005
Symbol
Item
Setting range
n:
MIDI channel
0H-FH (ch.1 - ch.16)
vv:
Control value,
00H-7FH (0 - 127)
Velocity value, etc.
(Only when the item is the Note On
Velocity, the setting range is “01H-7FH
(1 - 127)”.)
kk:
Note number
00H-7FH (0 - 127)
xx:
Switch on and off
00H-3FH (0 - 63): OFF
40H-7FH (64 - 127): ON
1. Receiving data
■Channel Voice Message
●Note On
Status
Second
Third
9nH
❍Balance (Controller Number 8)
Status
Second
Third
BnH
08H
vvH
*
OFF by default.
❍Panpot (Controller Number 10)
Status
Second
Third
BnH
0AH
vvH
*
OFF by default.
❍Expression (Controller Number 11)
Status
Second
Third
BnH
0BH
vvH
*
By default, controls the fade.
100% black: vv = 0
Normal output: vv = 64
100% white: vv = 127
❍Effect control1 (Controller Number 12)
Status
Second
Third
BnH
0CH
vvH
*
OFF by default.
❍Effect contr
❍Effect depth 4 (Controller Number 94)
Status
Second
Third
BnH
5EH
vvH
*
By default, controls the depth to which modulation is applied to Speed.
❍Effect depth 5 (Controller Number 95)
Status
Second
Third
BnH
5FH
vvH
*
OFF by default.
❍Data Increment (Controller Number 96)
Status
Second
Third
BnH
60H
vvH
*
By default, increments the value. The value (vv) is ignored.
❍Data Decrement (Controller Number 97)
Status
Second
Third
BnH
●Data set 1 (DT1)
Data set 1 is the message that transmits the real data. It is used when you set the
unit by transmitting the data.
Status
Data
Status
F0H
41H, dev, 00H,
F7H
00H, 0EH, 12H,
aaH, bbH, ccH,
ddH, ..., eeH, sum
Explanation of the byte
F0H
Exclusive status
41H
ID number (Roland)
dev
Device ID (dev:00H-1FH, default setting is 10H.)
00H
Model ID First Byte (CG-8)
00H
Model ID Second Byte (CG-8)
0EH
Model ID Third Byte (CG-
❍Breath type (Controller Number 2)
Status
Second
Third
BnH
02H
vvH
*
OFF by default.
❍Foot type (Controller Number 4)
Status
Second
Third
BnH
04H
vvH
*
OFF by default.
❍Portamento time (Controller Number 5)
Status
Second
Third
BnH
05H
vvH
*
By default, transmitted when you select a picture using the panel.
For a photo patch: vv = 0-47
For a stamp patch: vv = 0-15
❍Volume (Controller Number 7)
Status
Second
Third
BnH
07H
vvH
*
❍Sound Controller10 (Controller Number 79)
Status
Second
Third
BnH
4FH
vvH
*
By default, transmitted when you control the parameter Z modulation depth
from the panel.
❍General Purpose Controller 5–8 (Controller Number 80–83)
Status
Second
Third
BnH
50–53H
vvH
*
OFF by default.
❍Portamento control (Controller Number 84)
Status
Second
Third
BnH
54H
vvH
*
OFF by default.
❍Effect depth 2 (Controller Number 92)
Status
Second
■System Exclusive Message
Status
data
Status
F0H
iiH,ddH,...,eeH
F7H
F0H: Status of the system exclusive message
ii = ID number: Manufacturer number (ID number for the System Exclusive
message identifying the manufacturer). Roland’s manufacturer ID number is 41H.
The ID numbers 7EH and 7FH are used as extensions to the MIDI standard as the
universal non-realtime message (7EH) and the universal realtime message (7FH).
dd,...,ee = D
3. Parameter address map
3-1. CG-8 (Model ID = 00H 00H 0EH)
3-1-1. System Area
3-1-1-1. System Common Area
3-1-1-2. System Control Area
3-1-1-3. System Control Assign Area
Address
Parameter Name
00H 00H 00H 00H
System (See 3-1-1)
10H 00H 00H 00H
Layer (See 3-1-2)
Address
Parameter Name
00H 00H 00H 00H
System Common
00H 00H 01H 00H
System Control
00H 00H 02H 00H
System Control Assign
Address
Parameter Name
Sys.Ex. Value
Meaning of Valu
Roland CG-8 3-1-2. Layer Area
3-1-2-1. Layer Control (PHOTO) Area
3-1-2-2. Layer Control (STAMP) Area
Address
Parameter Name
10H 00H 00H 00H
Layer Control (PHOTO)
10H 00H 01H 00H
Layer Control (STAMP)
Address
Parameter Name
Sys.Ex. Value
Meaning of Value
10H 00H 00H 00H
Bank Number
00H-0FH
10H 00H 00H 01H
Program Number
00H-0FH
10H 00H 00H 02H
Photo Number
00H-2FH
10H 00H 00H 03H
Reserved
--
10H 00H 00H 04H
Trigger
00H-01H
OFF, ON
10H 00H 00H 05H
Roland CG-8 3-2. V-LINK (Model ID = 00H 51H)
*
V-LINK messages are only received, not transmitted. No response will be sent even in answer to Data Request 1.
*
When V-LINK is off, the V-LINK message is ignored.
*
Settings that are received during V-LINK is on are not saved.
*
The tables below show the correspondence between V-LINK parameter names and the CG-8’s parameters, and the default state of V-LINK (the state when only a V-LINK
ON messag
3-2-1. System Preference Area
3-2-2. Clip Control Assignment Area
3-2-3. Color Control Assignment Area
3-2-4. Clip Control Preference Area
Address
Parameter Name
Sys.Ex. Value
Meaning of Value
10H 00H 00H
V-LINK Enabled
00H-01H
OFF, ON
10H 00H 01H
V-LINK Clip Ctrl Rx MIDI Ch.
00H-0FH
1-16
10H 00H 02H
V-LINK Color Ctrl Rx MIDI Ch.
--
--
10H 00H 03H
V-LINk Note Message Enabled
00H, 02H
OFF, Assignable
10H 00H 04H
V-LINK Fast Control En
3-2-5. Color Control Preference Area
3-2-6. Sender Information Area
Address
Parameter Name
Sys.Ex. Value
Meaning of Value
10H 40H 00H
V-LINK Color Cb Ctrl Polarity
02H
Positive&Negative (FIXED)
10H 40H 01H
V-LINK Reserved Area
10H 40H 02H
V-LINK Color Cr Ctrl Polarity
--
10H 40H 03H
V-LINK Reserved Area
10H 40H 04H
V-LINK Brightness Ctrl Polarity
--
10H 40H 05H
V-LINK Reserved Area
10H 40H 06H
V-LINK Output Fade Ctrl Polarity
02H
Pos
Roland Switch Owners Instructions:
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | For Device |
|---|---|---|---|---|---|---|---|
v-1hd |
PDF User Manual (@89CF62), Roland v-1hd Switch (29-08-2026) |
68 | 1203 | 229 | 29-08-2026 | view all | |
XS-62S |
PDF Manual (@6TF44C), Roland XS-62S Switch (08-09-2026) |
35 | 875 | 132 | 08-09-2026 | view all | |
V-160HD |
PDF User Manual (@31L84W), Roland V-160HD Switch (17-09-2026) |
22 | 1144 | 172 | 17-09-2026 | view all | |
V-40HD |
PDF User Guide (@WX9Z99), Roland V-40HD Switch (12-05-2026) |
60 | 10.4 Mb | 260 | 50 | 12-05-2026 | view all |
V-1SDI |
V-1SDI Owner's manual - O5A1H9 |
40 | 512 | 113 | 23-09-2026 | view all | |
V-160HD |
#7C66X3: V-160HD Switch Startup manual |
12 | 1274 | 306 | 29-04-2026 | view all |