6000 Series PIR

6000 Series PIR Model PI6000 - with 30 lb. pet immunity Model 6000 - with high density (HD) performance lens Installation Instructions Description The 6000 Series Passive Infrared Detectors are designed for use in residential applications. These detectors utilize dual pyroelectric sensors with jumper selectable pulse count (two- or three-pulse mode). Advanced signal processing provides high immunity to false trips - RFI, lightning, vibration, and rapid temperature changes. An interchangeable, opaque Fresnel lens blocks visible light and provides the ability to select the best coverage pattern for the site. The lens is part of a sealed optic enclosure which isolates the pyroelectric sensor from drafts and insects, common sources of false trips. The 6000 series comes with a closed loop alarm contact and a closed loop tamper switch. .Selecting a Location • Mount the detector at a height of 7 to 9 feet (2.1 to 2.7m) . See Mounting Height Settings. • Mount the detector either flat on the wall or in a corner and at least 3/8” (0.95cm) from the ceiling. See Figure 2. • Do not locate the detector where it may be exposed to false alarm sources, such as: - heat sources in the field of view - direct or reflected sunlight - strong air drafts (fans, air conditioners, etc.) on unit • Do not aim the detector at windows or glass doors. • Mount the detector on a rigid, vibration-free surface. • Do not locate the detector on a surface exposed to moisture. • Do not locate the detector where the ambient temperature is below 14°F (-10°C) or above 122°F (50°C). • PIRs require a clear line of sight. Inform end-users not to block the coverage pattern with inventory, furniture, decorations etc. Figure 2. Mounting Flat Wall Corner 3/8” 0.95cm 3/8” 0.95cm Note Use a screwdriver to undo the latch on the bottom of the detector. T T + Ð NC C 266 267 266 Figure 1. Detector (Exploded) Back housing Circuit board Shield Front housing Lens Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

6000 Series PIR

Installing the Detector 1. Select an appropriate mounting location. 2. Route wiring to the detector’s location. 3. Open the detector and, after selecting appropriate mounting and wire entry options, remove the knockouts by depressing from the inside of the detector in the center of desired knockout (see Figure 3). The circuit board may be removed to facilitate mounting and removal of knockouts if desired. CAUTION You must be free of all electricity before handling sensor circuit boards. Touch a grounded bare metal surface before touching circuit boards or wear a grounding strap. Promptly reinstall the circuit board when finished with knockout removal and mounting the back housing. 4. Pull cable through the appropriate knockout and fasten the detector to the wall. 5. Strip back the outer jacket and individual wires of the cable and connect the conductors to the proper terminals (see Figure 4). The alarm contacts are not polarity sensitive. Note Use caution not to strip more insulation than needed, approxi- mately 1/4” (0.6cm), so that bare wires do not touch and cause a short. 6. Route the cable through the strain relief located on the far left side of the back housing (see Figure 3). Snap on the front housing. 7. Walk test the detector and check for desired coverage. Note Most units walk test more accurately if the person testing waits 10 seconds between tripping the unit and walking again. This allows the detector to stabilize between trips. Mounting Height Settings The factory setting of the detector is for mounting heights of 7 to 8 feet (2.1 to 2.4m). For this setting, the locking tab on the back housing is in the notch by the 7-8’ arrow on the circuit board (position A in Figure 4). For proper operation at mounting heights above 8 feet (2.4m), the locking tab must be in the notch by the 8-9’ arrow (position B in Figure 4). Figure 4 . Circuit Board Power In 10 to 16 VDC T       T +       –     NC  COM 3 2 8/9' 7/8' PET J4 LED J3 PULSE A B Jumpers J3 J4 Figure 3. Back Housing Wire entry hole for surface wire runs Primary wire entry hole for corner Primary mounting hole for flat wall mounting Locking tab Center wire entry hole Cable strain relief Additional wire entry hole Secondary mounting hole used to lock down when flat wall mounting Mounting holes for corner mounting Setting the Jumpers J3 Pulse Count - ON = Three-pulse mode OFF = Two-pulse mode (factory default) Note Use two-pulse mode for all residential applications including pet applications. J4 LED - ON = LED enabled (factory default) OFF = LED disabled Pet Applications A. For pet applications, the detector should be installed at the standard 7 to 8 feet (2.1 to 2.4m) mounting height. Verify that the circuit board is properly positioned in the back housing (see Mounting Height Settings). B. Place the pulse count selection jumper in two-pulse mode (see Setting the Jumpers). C. Make sure animals cannot get within 6 feet (1.8m) of the detector’s line of sight or climb on furniture within 6 feet (1.8m) of the detector. Note False alarm immunity from any number of small pets and rodents can be expected as long as the total combined weight does not exceed 30 lbs. and room temperature does not fall below 50° F (10° C). Long Hair Short Hair Not Recommmended Up to 50 lbs Up to 30 lbs Cocker Spaniel Basenji Doberman Eskimo Border Terrier Greyhound Husky French Bulldog Mastiff Pekinese Welsh Corgi Shepherd Sheepdog Cats St. Bernard The pet immunity feature has not been tested by Underwriters Laboratories Inc. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Figure 5. Zone Patterns

PI6000 Pet Immune Lens 6000 High Density Lens L K J I H G F E D C B A W V U T S R Q P O N M PI6000 Lens Mask PI6000 Pet Immune 6000 High Density Peel and stick groove side of lens Figure 6. Masks Masking 1. Unsnap the shield from the front cover by grasping the edge of the two tabs holding the shield in place and gently pulling the shield away from the front housing. Remove the lens from the front housing. Make sure fingers are clean. 2. Identify the lettered zone on the mask that corresponds to the letter on the lens. 3. Peel off the masking strip and press it onto the corresponding grooved segment on the lens. 4. Reinstall the lens in the front housing. The notch on the lens matches the notch on the front housing. (bottom right corner). 5. Snap the shield assembly back into the front cover. Maintaining the Detector When installed and used properly, the detectors provide up to 5 years of service with minimal maintenance. To ensure proper operation, walk test the detector annually. Clean the inside of the detector with a soft bristled brush or compressed air. Clean the outside with a damp (water) cloth as needed to keep it free of dust and dirt. Always test the detector after cleaning. 0' 0' 10' 3.0m 10' 3.0m 40' 12.2m 30' 9.1m 20' 6.1m 7' 2.1m 20' 6.0m 30' 9.0m 40' 12.2m 0' 60 30 15 4 Top View Top View Side View (Center Beams) Side View Floor Line Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

15480D / October, 2004

Specifications Voltage 10 to 16VDC Current 14mA Typical 20mA max. Maximum loop rating 16 VDC, 50mA Alarm output Fail safe contacts-closed loop Normally Closed (N.C.) Alarm duration 5 seconds ( ± 0.5 sec.) Cover tamper contacts Closed loop Rating 16V, 50mA Operating temperature 14°F to 122°F (-10°C to 50°C) Humidity 5 to 95% non-condensing Pulse count Two-pulse or three-pulse RFI immunity Greater than 10V/meter from 10 to 1000MHz Static Immunity 20 kV Lightning immunity 2.4 kV, 1.2 joules max. energy impulse, 100 usec duration on field wiring Detection range: PI6000 Pet Immune 40’ (12.2m) x 90° 6000 High Density 35’ (10.1m) x 90° Mounting Flat wall or corner Dimensions: Width 3.05" (7.75cm) Depth 1.90" (4.83cm) Height 2.68" (6.81cm) Color White USA & Canada: 800-547-2556 Technical Service: 800-648-7424 FaxBack: 800-483-2495 wm GE Security 12345 SW Leveton Drive Tualatin, OR 97062 Phone: 503-692-4052 Figure 7. Dimensions Front View Side View 2.68” 6.81cm 3.05” 7.75cm 1.90” 4.83cm The unit should be connected to a UL Listed power supply or control unit capable of providing a minimum of 4 hours standby power. The equipment should be installed in accordance with NFPA 70. The unit should be tested at least once a year. Model Description Listing PI6000 40’ x 40’ PIR with 30 lb Pet Immune Lens, closed loop, with tamper C-UL US 6000 35’ x 35’ PIR with High Density Lens, closed loop, with tamper C-UL US Product Ordering g Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]