GE PI6000 - Sentrol Motion Detector Installation Instructions
Read Online
Read the GE PI6000 - Sentrol Motion Detector Installation Instructions online using the built-in PDF viewer.
Text of the manual
6000 Series PIR
6000 Series PIR
Model PI6000 - with 30 lb. pet immunity
Model 6000 - with high density (HD) performance lens
Installation Instructions
Description
The 6000 Series Passive Infrared Detectors are designed for use in
residential applications. These detectors utilize dual pyroelectric
sensors with jumper selectable pulse count (two- or three-pulse mode).
Advanced signal processing provides high immunity to false trips - RFI,
lightning, vibration, and rapid temperature changes.
An interchangeable, opaque Fresnel lens blocks visible light and
provides the ability to select the best coverage pattern for the site. The
lens is part of a sealed optic enclosure which isolates the pyroelectric
sensor from drafts and insects, common sources of false trips.
The 6000 series comes with a closed loop alarm contact and a closed
loop tamper switch.
.Selecting a Location
•
Mount the detector at a height of 7 to 9 feet (2.1 to 2.7m) . See
Mounting Height Settings.
•
Mount the detector either flat on the wall or in a corner and at
least 3/8” (0.95cm) from the ceiling. See Figure 2.
•
Do not locate the detector where it may be exposed to false
alarm sources, such as:
- heat sources in the field of view
- direct or reflected sunlight
- strong air drafts (fans, air conditioners, etc.) on unit
•
Do not aim the detector at windows or glass doors.
•
Mount the detector on a rigid, vibration-free surface.
•
Do not locate the detector on a surface exposed to moisture.
•
Do not locate the detector where the ambient temperature is
below 14°F (-10°C) or above 122°F (50°C).
•
PIRs require a clear line of sight. Inform end-users not to block the
coverage pattern with inventory, furniture, decorations etc.
Figure 2. Mounting
Flat Wall
Corner
3/8”
0.95cm
3/8”
0.95cm
Note
Use a screwdriver to undo the
latch on the bottom of the detector.
T T
+ Ð NC C
266
267
266
Figure 1. Detector (Exploded)
Back housing
Circuit board
Shield
Front housing
Lens
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
6000 Series PIR
Installing the Detector
1.
Select an appropriate mounting location.
2.
Route wiring to the detector’s location.
3.
Open the detector and, after selecting appropriate mounting and
wire entry options, remove the knockouts by depressing from the
inside of the detector in the center of desired knockout (see Figure
3). The circuit board may be removed to facilitate mounting and
removal of knockouts if desired.
CAUTION
You must be free of all electricity before handling sensor circuit
boards. Touch a grounded bare metal surface before touching
circuit boards or wear a grounding strap. Promptly reinstall the
circuit board when finished with knockout removal and mounting
the back housing.
4.
Pull cable through the appropriate knockout and fasten the
detector to the wall.
5.
Strip back the outer jacket and individual wires of the cable and
connect the conductors to the proper terminals (see Figure 4). The
alarm contacts are not polarity sensitive.
Note
Use caution not to strip more insulation than needed, approxi-
mately 1/4” (0.6cm), so that bare wires do not touch and cause a
short.
6.
Route the cable through the strain relief located on the far left side
of the back housing (see Figure 3). Snap on the front housing.
7.
Walk test the detector and check for desired coverage.
Note
Most units walk test more accurately if the person testing waits
10 seconds between tripping the unit and walking again. This
allows the detector to stabilize between trips.
Mounting Height Settings
The factory setting of the detector is for mounting heights of 7 to 8 feet
(2.1 to 2.4m). For this setting, the locking tab on the back housing is in
the notch by the 7-8’ arrow on the circuit board (position A in Figure 4).
For proper operation at mounting heights above 8 feet (2.4m), the locking
tab must be in the notch by the 8-9’ arrow (position B in Figure 4).
Figure 4 . Circuit Board
Power In
10 to 16 VDC
T T
+ – NC COM
3
2
8/9' 7/8'
PET
J4 LED
J3
PULSE
A
B
Jumpers
J3 J4
Figure 3. Back Housing
Wire entry hole for
surface wire runs
Primary wire entry
hole for corner
Primary mounting hole
for flat wall mounting
Locking tab
Center wire
entry hole
Cable strain
relief
Additional wire entry hole
Secondary mounting hole
used to lock down when flat
wall mounting
Mounting
holes for
corner
mounting
Setting the Jumpers
J3 Pulse Count -
ON = Three-pulse mode
OFF = Two-pulse mode (factory default)
Note
Use two-pulse mode for all residential
applications including pet applications.
J4 LED -
ON = LED enabled (factory default)
OFF = LED disabled
Pet Applications
A. For pet applications, the detector should be installed at the standard
7 to 8 feet (2.1 to 2.4m) mounting height. Verify that the circuit board is
properly positioned in the back housing (see Mounting Height Settings).
B. Place the pulse count selection jumper in two-pulse mode (see
Setting the Jumpers).
C. Make sure animals cannot get within 6 feet (1.8m) of the detector’s
line of sight or climb on furniture within 6 feet (1.8m) of the detector.
Note
False alarm immunity from any number of small pets and rodents
can be expected as long as the total combined weight does not
exceed 30 lbs. and room temperature does not fall below 50° F
(10° C).
Long Hair
Short Hair
Not Recommmended
Up to 50 lbs
Up to 30 lbs
Cocker Spaniel
Basenji
Doberman
Eskimo
Border Terrier
Greyhound
Husky
French Bulldog
Mastiff
Pekinese
Welsh Corgi
Shepherd
Sheepdog
Cats
St. Bernard
The pet immunity feature has not been tested by Underwriters
Laboratories Inc.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Figure 5. Zone Patterns
PI6000
Pet Immune Lens
6000
High Density Lens
L K J I H G F E D C B A
W V U T S R Q P O N M
PI6000 Lens Mask
PI6000 Pet Immune
6000 High Density
Peel and stick groove side of lens
Figure 6. Masks
Masking
1.
Unsnap the shield from the front cover by grasping the edge of the
two tabs holding the shield in place and gently pulling the shield away
from the front housing. Remove the lens from the front housing.
Make sure fingers are clean.
2.
Identify the lettered zone on the mask that corresponds to the letter
on the lens.
3.
Peel off the masking strip and press it onto the corresponding grooved
segment on the lens.
4.
Reinstall the lens in the front housing. The notch on the lens matches
the notch on the front housing. (bottom right corner).
5.
Snap the shield assembly back into the front cover.
Maintaining the Detector
When installed and used properly, the detectors provide up to 5 years of
service with minimal maintenance. To ensure proper operation, walk test
the detector annually.
Clean the inside of the detector with a soft bristled brush or compressed
air. Clean the outside with a damp (water) cloth as needed to keep it free of
dust and dirt. Always test the detector after cleaning.
0'
0'
10'
3.0m
10'
3.0m
40'
12.2m
30'
9.1m
20'
6.1m
7'
2.1m
20'
6.0m
30'
9.0m
40'
12.2m
0'
60
30
15
4
Top View
Top View
Side View
(Center Beams)
Side View
Floor Line
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
15480D / October, 2004
Specifications
Voltage
10 to 16VDC
Current
14mA Typical 20mA max.
Maximum loop rating
16 VDC, 50mA
Alarm output
Fail safe contacts-closed loop
Normally Closed (N.C.)
Alarm duration
5 seconds ( ± 0.5 sec.)
Cover tamper contacts
Closed loop
Rating
16V, 50mA
Operating temperature
14°F to 122°F (-10°C to 50°C)
Humidity
5 to 95% non-condensing
Pulse count
Two-pulse or three-pulse
RFI immunity
Greater than 10V/meter from 10 to
1000MHz
Static Immunity
20 kV
Lightning immunity
2.4 kV, 1.2 joules max. energy
impulse, 100 usec duration on field
wiring
Detection range:
PI6000 Pet Immune
40’ (12.2m) x 90°
6000 High Density
35’ (10.1m) x 90°
Mounting
Flat wall or corner
Dimensions:
Width
3.05" (7.75cm)
Depth
1.90" (4.83cm)
Height
2.68" (6.81cm)
Color
White
USA & Canada: 800-547-2556
Technical Service: 800-648-7424
FaxBack: 800-483-2495
wm
GE Security
12345 SW Leveton Drive
Tualatin, OR 97062
Phone: 503-692-4052
Figure 7. Dimensions
Front View
Side View
2.68”
6.81cm
3.05”
7.75cm
1.90”
4.83cm
The unit should be connected to a UL Listed power supply or control unit
capable of providing a minimum of 4 hours standby power.
The equipment should be installed in accordance with NFPA 70.
The unit should be tested at least once a year.
Model
Description
Listing
PI6000
40’ x 40’ PIR with 30 lb Pet Immune Lens, closed loop, with tamper
C-UL US
6000
35’ x 35’ PIR with High Density Lens, closed loop, with tamper
C-UL US
Product Ordering
g
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]