Long Distance Cylindrical Proximity Sensor

E2A3 Extra long distance for increased protection and sensing performance • triple distance proximity sensors for flush mounting re- quirements. • designed and tested for extra long life. . Ordering Information DC 3-wire Models Note:Material specifications for stainless steel housing case: 1.4305 (W.-No.), SUS303 (AISI), 2346 (SS). Size Type Sensing distance Connection Body material Thread length Output Operation mode: NO Operation mode: NC M8 Shielded 3.0mm Pre-wired Stainless steel (See note.) 27 (40) mm PNP E2A3-S08KS03-WP-B1 2M E2A3-S08KS03-WP-B2 2M NPN E2A3-S08KS03-WP-C1 2M E2A3-S08KS03-WP-C2 2M M12 connector 27 (44) mm PNP E2A3-S08KS03-M1-B1 E2A3-S08KS03-M1-B2 NPN E2A3-S08KS03-M1-C1 E2A3-S08KS03-M1-C2 M8 connector (3-pin) 27 (40) mm PNP E2A3-S08KS03-M5-B1 E2A3-S08KS03-M5-B2 NPN E2A3-S08KS03-M5-C1 E2A3-S08KS03-M5-C2 M12 Shielded 6.0mm Pre-wired Brass 34 (50) mm PNP E2A3-M12KS06-WP-B1 2M E2A3-M12KS06-WP-B2 2M NPN E2A3-M12KS06-WP-C1 2M E2A3-M12KS06-WP-C2 2M M12 connector 34 (49) mm PNP E2A3-M12KS06-M1-B1 E2A3-M12KS06-M1-B2 NPN E2A3-M12KS06-M1-C1 E2A3-M12KS06-M1-C2 M18 Shielded 11.0mm Pre-wired Brass 39 (60) mm PNP E2A3-M18KS11-WP-B1 2M E2A3-M18KS11-WP-B2 2M NPN E2A3-M18KS11-WP-C1 2M E2A3-M18KS11-WP-C2 2M M12 connector 39 (54) mm PNP E2A3-M18KS11-M1-B1 E2A3-M18KS11-M1-B2 NPN E2A3-M18KS11-M1-C1 E2A3-M18KS11-M1-C2 M30 Shielded 20.0mm Pre-wired Brass 44 (65) mm PNP E2A3-M30KS20-WP-B1 2M E2A3-M30KS20-WP-B2 2M NPN E2A3-M30KS20-WP-C1 2M E2A3-M30KS20-WP-C2 2M M12 connector 44 (59) mm PNP E2A3-M30KS20-M1-B1 E2A3-M30KS20-M1-B2 NPN E2A3-M30KS20-M1-C1 E2A3-M30KS20-M1-C2

E2A3 Sensors are available with the following connectors and cable materials:

Pre-wired Models Standard cable lengths are 2 m and 5 m. For other cable lengths, please contact your OMRON representative. Standard cable material: PVC (4-mm dia.) -WP Connector Models Standard connectors: M12, M8 (3-pin) -M1, -M5 Model Number Legend Example: E2A3-M12KS06-M1-B1 Triple distance, M12, standard barrel, shielded, Sn = 6 mm, M12 connector, PNP-NO E2A3-S08KS03-WP-B1 2M Triple distance, M8 stainless steel, standard barrel, shielded, Sn = 3 mm, pre-wired PVC cable, PNP-NO, cable length = 2 m 1. Basic name E2A 2. Sensing technology Blank: Standard double distance 3: Triple distance 3. Housing shape and material M: Cylindrical, metric threaded, brass S: Cylindrical, metric threaded, stainless steel 4. Housing size 08: 8 mm 12: 12 mm 18: 18 mm 30: 30 mm 5. Barrel length K: Standard length L: Long body 6. Shield S: Shielded N: Non-shielded 7. Sensing distance Numeral: Sensing distance: e.g., 03 = 3 mm, 11 = 11 mm 8. Kind of connection WP: Pre-wired, PVC, 4-mm dia. M1: M12 connector (4-pin) * M5: M8 connector (3-pin) 9. Power source and output B: DC, 3-wire, PNP open collector C: DC, 3-wire, NPN open collector 10.Operation mode 1: Normally open (NO) 2: Normally closed (NC) 11.Specials (e.g., cable material, oscillating frequency) 12.Cable length Blank: Connector Model Numeral: Cable length 2 3 4 5 6 7 8 9 10 11 1 12 E2A@-@@@@@-@-@@-@@

DC 3-wire Models

Note 1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object length between sensing objects, and a set distance of half the sensing distance. 2. For USA and Canada: use class 2 circuit only. Size M8 M12 M18 M30 Type Shielded Shielded Shielded Shielded Item E2A3-S08KS03-@@-B@ E2A3-S08KS03-@@-C@ E2A3-M12KS06-@@-B@ E2A3-M12KS06-@@-C@ E2A3-M18KS11-@@-B@ E2A3-M18KS11-@@-C@ E2A3-M30KS20-@@-B@ E2A3-M30KS20-@@-C@ Sensing distance 3 mm ± 10% 6 mm ± 10% 11 mm ± 10% 20 mm ± 10% Setting distance Ambient temp. of −25 to 70°C 0 to 2.1 mm 0 to 4.2 mm 0 to 7.7 mm 0 to 14 mm Ambient temp. of −10 to 60°C 0 to 2.4 mm 0 to 4.8 mm 0 to 8.8 mm 0 to 16 mm Differential travel 20% max. of sensing distance Target Ferrous metal (The sensing distance decreases with non-ferrous metal.) Standard sensing object 9 × 9 × 1 mm 18 × 18 × 1 mm 33 × 33 × 1 mm 60 × 60 × 1 mm Response frequency (See note 1.) 700 Hz 350 Hz 250 Hz 80 Hz Power supply voltage (operating voltage range) 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) Current consumption 10 mA max. Output type -B models: PNP open collector -C models: NPN open collector Control output Load current 200 mA max. (32 VDC max.) Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m) Indicator Operation indicator (Yellow LED) Operation mode -B1/-C1 models: NO -B2/-C2 models: NC For details, refer to the timing charts. Protection circuits Power source circuit re- verse polarity protection, Surge suppressor, Short- circuit protection Output reverse polarity protection, Power source circuit reverse polarity protec- tion, Surge suppressor, Short-circuit protection Ambient air temperature Operating: −25°C to 70°C, Storage: −25°C to 70°C Temperature influence ±20% max. of sensing distance at 23°C within temperature range of −25°C to 70°C −10% to +20% of sensing distance at 23°C within temperature range of −10°C to 60°C Ambient humidity Operating: 35% to 95%, Storage: 35% to 95% Voltage influence ±1% max. of sensing distance in rated voltage range ±15% Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC at 50/60 Hz for 1 min between current-carrying parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance 500 m/s2, 10 times each in X, Y, and Z directions 1,000 m/s2, 10 times each in X, Y and Z directions Standards and listings (See note 2.) IP67 after IEC 60529 IP69K after DIN 40050 EMC after EN60947-5-2 Connection method -WP models: Pre-wired Models (4-mm dia. PVC cable with length of 2 m) -M1 models: M12 4-pin Connector Models -M5 models: M8 3-pin Connector Models Weight (packed state) Pre-wired Models Approx. 65 g Approx. 85 g Approx. 160 g Approx. 280 g Connector Models M12 Connector Models: Approx. 20 g Approx. 35 g Approx. 70 g Approx. 200 g Material Case Stainless steel Brass-nickel plated Sensing surface PBT Cable PVC Clamping nut Stainless steel Brass-nickel plated

Operating Range (Typical)

Influence of Sensing Object Size and Materials Distance Y (mm) Sensing distance X (mm) 22 20 18 16 14 12 10 8 6 4 2 0 −30 −20 −10 0 10 20 30 X Y E2A3-M30KS20 E2A3-M18KS11 E2A3-M12KS06 E2A3-S08KS03 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 0 5 10 15 20 25 Side length of sensing object d (mm) Sensing distance X (mm) E2A3-S08KS03 X @d t = 1 mm Iron Brass Copper Stainless steel (SUS303) Aluminum 7 6 5 4 3 2 1 0 0 5 10 15 20 25 30 Side length of sensing object d (mm) Sensing distance X (mm) E2A3-M12KS06 X @d t = 1 mm Iron Brass Copper Stainless steel (SUS303) Aluminum 12 10 8 6 4 2 0 0 10 20 30 40 50 Side length of sensing object d (mm) Sensing distance X (mm) E2A3-M18KS11 X @d t = 1 mm Aluminum Iron Brass Copper Stainless steel (SUS303) 25 20 15 10 5 0 Side length of sensing object d (mm) Sensing distance X (mm) E2A3-M30KS20 X @d t = 1 mm 0 10 20 30 40 50 60 Iron Brass Copper Stainless steel (SUS303) Aluminum

DC 3-wire Models

PNP Output Operation mode Model Timing chart Output circuit NO E2A3-@-@-B1 NC E2A3-@-@-B2 Sensing object (%) 100 0 Rated sensing distance Sensing area Non-sensing area Proximity Sensor ON OFF ON OFF Yellow indicator Control output 3 1 2 4 3 1 4 Load Brown Black (See note 1.) Blue +V 0 V Note 1: With M8 Size Models, there is no output reverse polarity protection diode. M12 Connector Pin Arrangement (See note 2.) M8 Connector (3-pin) Pin Arrangement Note 2: Terminal 2 of the M12 connector is not used. Proximity Sensor main circuits (%) 100 0 Sensing object Rated sensing distance Sensing area Non-sensing area Proximity Sensor ON OFF ON OFF Yellow indicator Control output 3 1 2 4 Load Brown Black (See note 1.) Blue +V 0 V Note 1: With M8 Size Models, there is no output reverse polarity protection diode. M12 Connector Pin Arrangement (See note 2.) 3 1 4 M8 Connector (3-pin) Pin Arrangement Note 2: Terminal 4 of the M12 connector is not used. Proximity Sensor main circuits (M8 connector: )

DC 3-wire Models

NPN Output Operation mode Model Timing chart Output circuit NO E2A3-@-@-C1 NC E2A3-@-@-C2 Sensing object (%) 100 0 Rated sensing distance Sensing area Non-sensing area Proximity Sensor ON OFF ON OFF Yellow indicator Control output Load Brown Black (See note 1.) Blue +V 0 V Note 1: With M8 Size Models, there is no output reverse polarity protection diode. Note 2: Terminal 2 of the M12 connector is not used. Proximity Sensor main circuits 3 1 2 4 M12 Connector Pin Arrangement (See note 2.) 3 1 4 M8 Connector (3-pin) Pin Arrangement (%) 100 0 Sensing object Rated sensing distance Sensing area Non-sensing area Proximity Sensor ON OFF ON OFF Yellow indicator Control output Load Brown Black (See note 1.) Blue +V 0 V Note 1: With M8 Size Models, there is no output reverse polarity protection diode. Note 2: Terminal 4 of the M12 connector is not used. Proximity Sensor main circuits (M8 connector: ) 3 1 2 4 M12 Connector Pin Arrangement (See note 2.) 3 1 4 M8 Connector (3-pin) Pin Arrangement

Note:All units are in millimeters unless otherwise indicated.

Pre-wired Models E2A3-S08KS03-WP-@@ Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conduc- tor cross section: 0.3 mm2; Insulator diameter: 1.3 mm), Standard length: 2 m 2. Operation indicator (yellow) E2A3-M12KS06-WP-@@ Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conduc- tor cross section: 0.3 mm2; Insulator diameter: 1.3 mm), Standard length: 2 m 2. Operation indicator (yellow) E2A3-M18KS11-WP-@@ Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conduc- tor cross section: 0.3 mm2; Insulator diameter: 1.3 mm), Standard length: 2 m 2. Operation indicator (yellow) E2A3-M30KS20-WP-@@ Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (Conduc- tor cross section: 0.3 mm2; Insulator diameter: 1.3 mm), Standard length: 2 m 2. Operation indicator (yellow) M12 Connector Models E2A3-S08KS03-M1-@@ Note:Operation indicator (yellow LED, 4×90°) E2A3-M12KS06-M1-@@ Note:Operation indicator (yellow LED, 4×90°) E2A3-M18KS11-M1-@@ Note:Operation indicator (yellow LED, 4×90°) E2A3-M30KS20-M1-@@ Note:Operation indicator (yellow LED, 4×90°) 40 26.8 4 5 13 (See note 1.) Indicator (See note 2.) Two, clamping nuts M8×1 17 50.4 34 5.5 12 (See note 1.) Indicator (See note 2.) Two, clamping nuts M12×1 24 59.6 39 6 15 (See note 1.) Indicator (See note 2.) Two, clamping nuts M18×1 36 64.6 44 7 15 (See note 1.) Indicator (See note 2.) Two, clamping nuts M30×1.5 43.9 26.8 4 5 13 Indicator (See note.) Two, clamping nuts M8×1 M12×1 17 49.2 34 5.5 12 Indicator (See note.) Two, clamping nuts M12×1 M12×1 24 54.2 39 6 15 Indicator (See note.) Two, clamping nuts M18×1 M12×1 36 59.2 44 7 15 Indicator (See note.) Two, clamping nuts M30×1.5 M12×1

M8 Connector Models

E2A3-S08KS03-M5-@@ Note:Operation indicator (yellow LED, 4×90°) 39.8 26.8 4 5 13 Two, clamping nuts M8×1 M8×1 Indicator (See note.) Mounting Hole Cutout Dimensions F External diameter of Proximity Sensor Dimension F (mm) M18 M30 M8 M12 8.5 dia. +0.5 0 12.5 dia. +0.5 0 18.5 dia. +0.5 0 30.5 dia. +0.5 0

Precautions for Safe Use

Power Supply Do not impose an excessive voltage on the E2A3, otherwise it may be damaged. Do not impose AC current (100 to 240 VAC) on any DC Model, otherwise it may be damaged. Load Short-circuit Do not short-circuit the load, or the E2A3 may be damaged. The E2A3’s short-circuit protection function will be valid if the polarity of the supply voltage is correct and within the rated voltage range. Wiring Be sure to wire the E2A3 and load correctly, otherwise it may be damaged. Connection with No Load Be sure to insert a load when wiring. Make sure to connect a proper load to the E2A3 during operation, otherwise it may damage internal elements. Do not expose the product to flammable or explo- sive gases. Do not disassemble, repair, or modify the product. Precautions for Correct Use Designing Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If separate power supplies are connected to the Proxim- ity Sensor and load, be sure to supply power to the Proximity Sensor before supplying power to the load. Effects of Surrounding Metal When mounting the E2A3 within a metal panel, ensure that the clearances given in the following tables are maintained. (Unit: mm) (Unit: mm) * Using the nuts provided with the E2A3 allows mounting in the way shown be- low. Power OFF The Proximity Sensor may output a pulse signal when it is turned OFF. Therefore, it is recommended that the load be turned OFF before turning OFF the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power sup- ply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Mutual Interference When installing two or more Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. (Unit: mm) This product is not designed or rated for ensuring safety of persons. Do not it for such purposes. WARNING Model Dimension M8 M12 Material of surrounding metal Ferrous metal Non- ferrous metal Ferrous metal Non- ferrous metal E2A3 Shielded l 0.5 (*) 2 (*) 2 (*) 1 (*) m 9 18 d 24 36 D 0.5 2 2 1 n 24 36 Model Dimension M18 M30 Material of surrounding metal Ferrous metal Non- ferrous metal Ferrous metal Non- ferrous metal E2A3 Shielded l 4 (*) 2.5 (*) 6 (*) 4 (*) m 33 60 d 54 90 D 4 2.5 6 4 n 54 90 l m n m D d dia. l l = 0 mm Nut provided with E2A3 Type Dimension M8 M12 M18 M30 Shielded A 25 35 70 110 B 20 25 45 70 A A B

Wiring through Metal Conduit:

If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to pre- vent against Proximity Sensor damage or malfunctioning. Cable Extension The standard cable length is less than 200 m. The tractive force is 50 N. Mounting The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its water-resistance. Do not tighten the nut with excessive force. A washer must be used with the nut. Maintenance and Inspection Periodically perform the following checks to ensure stable operation of the Proximity Sensor over a long period of time. 1. Check for mounting position, dislocation, looseness, or distortion of the Proximity Sensor and sensing objects. 2. Check for loose wiring and connections, improper contacts, and line breakage. 3. Check for attachment or accumulation of metal powder or dust. 4. Check for abnormal temperature conditions and other environ- mental conditions. 5. Check for proper lighting of indicators (for models with a set indi- cator). Never attempt to disassemble or repair the Sensor. Environment Water Resistivity The Proximity Sensors are tested intensively on water resistance, but to ensure maximum performance and life expectancy, avoid immer- sion in water and provide protection from rain or snow. Operating Environment Store and operate the Proximity Sensor only within the given specifi- cations. Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor. Connect the load to the Proximity Sensor through a relay. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer’s application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. Type Torque M8 Stainless Steel Model 9 N·m Brass Model --- M12 20 N·m M18 60 N·m M30 150 N·m In the interest of product improvement, specifications are subject to change without notice. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. D102-E2-01A-X