This manual provides you with the basic information
required to install the Simrad ES60 Fish finding echo
sounder. For more detailed information about the practical
use of the product, refer to the Operator manual.
304699/A
September 2006
Document number: 304699 / ISBN-10: 82-8066-072-0 / ISBN-13: 978-82-8066-072-5
Rev. A
September 2006
First version. Information is extracted from the former Instruction
manual, and several details have been changed.
Copyright
©2006 Simrad Horten AS
The information contained in this document remains the sole property of Simrad Horten AS. No part of this
document may be copied or reproduced in any form or by any means, and the information co
Table of contents
INTRODUCTION ................................................................ 9
Simplified system diagram .....................................................................................10
General safety rules................................................................................................11
General supply conditions...................................................................................
INSTALLATION PROCEDURES ......................................... 26
Basic procedure ......................................................................................................26
Configuration..........................................................................................................27
Transducer ................................................................................................. 27
General Purpose Transce
Single beam, normal power transducer ......................................................... 68
Single beam, high power transducer............................................................. 69
Dual beam (wide or narrow) transducer........................................................ 70
Split beam transducer.................................................................................. 71
Split beam transducer to single beam tr
Simrad ES60 - DATASHEET REV A DRAWING FILE ............................................................... 99
GPT Outline dimensions ......................................................................................100
GPT Power supply outline dimensions ................................................................102
Marine computer outline dimensions...................................................................104
GPT Transducer plug connection................
All 27 kHz transducers.........................................................................................144
All 38 kHz transducers.........................................................................................145
All 50 kHz transducers.........................................................................................147
All 70 khz transducers.........................................................................
The purpose of this installation manual is to present the
descriptions and drawings required to install the Simrad ES60
Fish finding echo sounder system. The equipment described
in this manual includes the complete system with associated
cabinets, but not those system units provided locally by the
customer, installation shipyard or local dealer.
The manual also defines the equipment responsibility, and
provides instructions for
Simplified system diagram
A simplified system diagram is shown below.
System diagram with one transceiver
SIMRAD GPT
(CD010200D)
B
C
D
A
(A) = Colour monitor
(B) = Processor Unit (computer)
(C) = General Purpose Transceiver (GPT)
(D) = Transducer
10
304699/A
General safety rules
The Simrad ES60 Fish finding echo sounder system operates on
230 Vac 50/60 Hz.
WARNING
This voltage may be lethal!
The following safety precautions must be followed at all times
during installation and maintenance work:
•
Always switch off all power before installation or
maintenance. Use the main circuit breaker, and label
the breaker with a warning sign that informs others that
maintenance or installation work is bein
General supply conditions
The following supply conditions are applicable to this Simrad
ES60 Fish finding echo sounder delivery.
Equipment responsibility
The shipyard performing the installation and/or equipment dealer
becomes fully responsible for the equipment upon receipt unless
otherwise stated in the contract. The duration of responsibility
includes:
•
The period of time the equipment is stored locally before
installation.
•
During th
Simrad ES60 - DATASHEET REV A General installation requirements
The following installation requirements are applicable to this
Simrad ES60 Fish finding echo sounder delivery.
Approval by classification society
The ES60 Fish finding echo sounder transducer installation
must be approved by Det Norske Veritas (DNV) or another
classification society. The shipowner and shipyard performing
the installation are responsible for obtaining installation approval.
Supply power
The
The location of the transducer and/or protection blister must be
noted on the vessel’s docking plan for future reference.
Wiring
All cables running between system cabinets located in different
rooms and/or on different decks must be supported and protected
along their entire lengths using conduits and/or cable trays. Note
that the cables must not be installed in the vicinity of high-power
supplies and cables, antenna cables or other poss
This section provides the basic rules for transportation, storage
and handling of units. In this context, a unit may be any large or
small part of the system. It can be supplied as part of the initial
delivery, or as a spare part.
Transportation
Unless otherwise stated in the accompanying documentation,
electronic, electro-mechanical and mechanical units supplied
by Simrad can be transported using all methods approved for
de
Heavy units may be equipped with lifting lugs for transportation
by crane within the workshop or installation area. Before you
use a crane:
•
You must check the applicable weight certificate for the crane.
•
You must check the security of the lifting lugs.
Ensure that all available lifting lugs are used. Ensure the unit
remains under control during the operation to avoid damage to
the unit, equipment or personnel.
Heavy units may be transp
The storage room/area must be dry, with a non-condensing
atmosphere. It must be free from corrosive agents.
9
The storage area’s mean temperature must not be lower than
-30° C, and not warmer than +70° C. If other limitations
apply, the crates will be marked accordingly.
Note
Transducers must not be stored in temperatures below -20°
C, or higher than +60° C.
10
The crate must not be exposed to moisture from fluid
leakages.
11
The crat
Simrad ES60 - DATASHEET REV A If the units are not damaged, check the humidity absorbing
material. If required, dry or replace the bags, then re-pack
the unit(s) according to the packing instructions.
Unpacking
General unpacking procedure
Normal precautions for the handling, transportation and storage
of fragile electronic equipment must be undertaken.
Note