Simrad ES60 - DATASHEET REV A Installation Manual

Text of Simrad ES60 - DATASHEET REV A Installation Manual

M A X I M I Z I N G

Y O U R P E R F O R M A N C E A T S E A www.SIMRAD.com

This manual provides you with the basic information

required to install the Simrad ES60 Fish finding echo sounder. For more detailed information about the practical use of the product, refer to the Operator manual. 304699/A September 2006

Document number: 304699 / ISBN-10: 82-8066-072-0 / ISBN-13: 978-82-8066-072-5

Rev. A September 2006 First version. Information is extracted from the former Instruction manual, and several details have been changed. Copyright ©2006 Simrad Horten AS The information contained in this document remains the sole property of Simrad Horten AS. No part of this document may be copied or reproduced in any form or by any means, and the information co

Table of contents

INTRODUCTION ................................................................ 9 Simplified system diagram .....................................................................................10 General safety rules................................................................................................11 General supply conditions...................................................................................

INSTALLATION PROCEDURES ......................................... 26

Basic procedure ......................................................................................................26 Configuration..........................................................................................................27 Transducer ................................................................................................. 27 General Purpose Transce

Single beam, normal power transducer ......................................................... 68

Single beam, high power transducer............................................................. 69 Dual beam (wide or narrow) transducer........................................................ 70 Split beam transducer.................................................................................. 71 Split beam transducer to single beam tr

Simrad ES60 - DATASHEET REV A DRAWING FILE ............................................................... 99

GPT Outline dimensions ......................................................................................100 GPT Power supply outline dimensions ................................................................102 Marine computer outline dimensions...................................................................104 GPT Transducer plug connection................

All 27 kHz transducers.........................................................................................144

All 38 kHz transducers.........................................................................................145 All 50 kHz transducers.........................................................................................147 All 70 khz transducers.........................................................................

The purpose of this installation manual is to present the

descriptions and drawings required to install the Simrad ES60 Fish finding echo sounder system. The equipment described in this manual includes the complete system with associated cabinets, but not those system units provided locally by the customer, installation shipyard or local dealer. The manual also defines the equipment responsibility, and provides instructions for

Simplified system diagram

A simplified system diagram is shown below. System diagram with one transceiver SIMRAD GPT (CD010200D) B C D A (A) = Colour monitor (B) = Processor Unit (computer) (C) = General Purpose Transceiver (GPT) (D) = Transducer 10 304699/A

General safety rules

The Simrad ES60 Fish finding echo sounder system operates on 230 Vac 50/60 Hz. WARNING This voltage may be lethal! The following safety precautions must be followed at all times during installation and maintenance work: • Always switch off all power before installation or maintenance. Use the main circuit breaker, and label the breaker with a warning sign that informs others that maintenance or installation work is bein

General supply conditions

The following supply conditions are applicable to this Simrad ES60 Fish finding echo sounder delivery. Equipment responsibility The shipyard performing the installation and/or equipment dealer becomes fully responsible for the equipment upon receipt unless otherwise stated in the contract. The duration of responsibility includes: • The period of time the equipment is stored locally before installation. • During th

Simrad ES60 - DATASHEET REV A General installation requirements

The following installation requirements are applicable to this Simrad ES60 Fish finding echo sounder delivery. Approval by classification society The ES60 Fish finding echo sounder transducer installation must be approved by Det Norske Veritas (DNV) or another classification society. The shipowner and shipyard performing the installation are responsible for obtaining installation approval. Supply power The

The location of the transducer and/or protection blister must be

noted on the vessel’s docking plan for future reference. Wiring All cables running between system cabinets located in different rooms and/or on different decks must be supported and protected along their entire lengths using conduits and/or cable trays. Note that the cables must not be installed in the vicinity of high-power supplies and cables, antenna cables or other poss

This section provides the basic rules for transportation, storage

and handling of units. In this context, a unit may be any large or small part of the system. It can be supplied as part of the initial delivery, or as a spare part. Transportation Unless otherwise stated in the accompanying documentation, electronic, electro-mechanical and mechanical units supplied by Simrad can be transported using all methods approved for de

Heavy units may be equipped with lifting lugs for transportation

by crane within the workshop or installation area. Before you use a crane: • You must check the applicable weight certificate for the crane. • You must check the security of the lifting lugs. Ensure that all available lifting lugs are used. Ensure the unit remains under control during the operation to avoid damage to the unit, equipment or personnel. Heavy units may be transp

The storage room/area must be dry, with a non-condensing

atmosphere. It must be free from corrosive agents. 9 The storage area’s mean temperature must not be lower than -30° C, and not warmer than +70° C. If other limitations apply, the crates will be marked accordingly. Note Transducers must not be stored in temperatures below -20° C, or higher than +60° C. 10 The crate must not be exposed to moisture from fluid leakages. 11 The crat

Simrad ES60 - DATASHEET REV A If the units are not damaged, check the humidity absorbing

material. If required, dry or replace the bags, then re-pack the unit(s) according to the packing instructions. Unpacking General unpacking procedure Normal precautions for the handling, transportation and storage of fragile electronic equipment must be undertaken. Note If the unit is not to be prepared for immediate use, you may consider storing it unopened in its original packing ma