SMC Networks EZ Connect Quick Install Manual
Read Online
Read the SMC Networks EZ Connect Quick Install Manual online using the built-in PDF viewer.
EZ Connect Quick Install Manual: Key Pages of Document
SMC8002CM-US EZ Connect™ USB/Ethernet Cable Modem • Complies with DOCSIS 1.0 cable modem requirements • Concurrent USB and Ethernet support • Up to 40Mpbs downstream and 10Mbps upstream • Supports SNMP management ...
2 LED Functions 3 Installing the Modem 3 Package Contents 3 Mounting the Modem 4 System Requirements 4 Connecting the Modem 5 Installation 6 USB Installation for Windows 98, Window 2000 and Windows Me 6 Ethernet Installation for Windows 6 Windows 95/98/NT 6 Windows 2000 6 Making a Connection to the Ethernet Port 7 Product Specifications 8 General Specifications 8 Physical Characteristics 8 Troubleshooting 10 Cannot Connect to the Internet 10 Port and Cable Assignments 11 Straight-Through Wiring 12 Crossover Wiring 12 EMI Certification 13 FCC Class B Certification (USA) 13 Canada Departmen ...
cable network system that brings cable TV service to the home. The data transmission rate on the cable connection is asymmetric, in that it provides a higher data rate in the downstream (receive) direction than in the upstream (transmit) direction. Asymmetric operation is ideal for typical home and small office use where files and information are downloaded more frequently than uploaded. This modem has a USB connection which provides plug and play installation, and an Ethernet connection that allows you to connect up to 16 computers with the use of an Ethern ...
2 Description of Hardware The SMC8002CM-US is an external DOCSIS-based cable modem product for high-speed Internet access applications.The modem provides an optional USB or Ethernet connection to a PC or LAN. In an Ethernet LAN environment, it supports up to 16 PCs, allowing shared Internet access. The following figure shows the components of this modem: Cable Connector USB Port RJ-45 Port PWR LINK ACT STS Status LEDs ETHERNET RESET CABLE IN POWER Power Socket USB ...
3 LED Functions The EZ Connect Cable Modem contains four LEDs on the top panel. The operational status of the modem is indicated by the LED conditions listed below. Installing the Modem Before installing the modem, verify that you have all the items listed under “Package Contents”. If any of the items are missing or damaged, contact your local SMC distributor. Also, be sure you have all the necessary tools and cabling before installing the modem Package Contents This package includes: LED Status Description PWR On Red Power is being supplied to the modem. LINK On Green Indicates a valid 10/100Mbps Ethernet link. ACT On Green In ...
4 Mounting the Modem The SMC8002CM-US comes with a slot-in stand with which it may be mounted vertically or horizontally. To do this, simply slide the modem on to the stand with the flanges provided on the base or the side. The two mounting options are illustrated below. System Requirements The SMC8002CM-US requires the following PC features to operate: • For USB connection: - A PC equipped with a USB port - Windows 98, Windows 98 SE, Windows Me or Windows 2000 • For Ethernet Connection: - A PC with a 10/100 Mbps Ethernet adapter card installed - Windows 95 or later, Windows NT 4.0 or later ETHERNET USB CABLE IN POWER Slot- ...
5 Connecting the Modem Before connecting the EZ Connect Cable Modem, contact your cable service provider and check the following points: • Be sure that your service provider supplies a two-way data link. • Check that they have set up an Internet Access Account. To do this you will need to provide information that may include the product number and the modem MAC address. You will find this information on the label on the base of the modem. The modem must be correctly connected to the service provider’s cable jack. If you are connecting both a TV and the modem to this outlet, you will need to use a splitter. The splitter duplic ...
6 Installation USB Installation for Windows 98, Window 2000 and Windows Me 1. Insert the square (B-type) USB plug of the USB cable into the USB port at the back of the modem and the rectangular (A-type) USB plug into the USB port at the back of the computer. 2. The “Found New Hardware” screen will appear. Insert the driver disk. When prompted for the location of a driver, enter the drive letter of your floppy disk drive. 3. Follow the instructions given to install the driver. 4. Reboot your computer when prompted. Ethernet Installation for Windows To connect the EZ Connect Cable Modem to a computer through the Ethernet port ...
7 Making a Connection to the Ethernet Port You can use straight-through twisted-pair cable to connect the Ethernet port on the modem to a PC. 1. Make sure you have installed a 10/100Mbps network adapter card in the PC. 2. Prepare straight-through shielded or unshielded twisted-pair cables with RJ-45 plugs at both ends. Use 100-ohm Category 3, 4 or 5 cable for this 10 Mbps Ethernet connection. 3. Connect one end of the cable to the RJ-45 port of the network interface card, and the other end to the Ethernet port on the modem. When inserting an RJ-45 plug, be sure the tab on the plug clicks into position to ensure that it is properly ...
8 Product Specifications General Specifications Standards Conformance DOCSIS 1.0, IEEE 802.3, IEEE 802.3u, USB 1.1 Cable Modem Requirements Modulation Downstream: 64-QAM/256-QAM (receive) Upstream: QPSK/16-QAM (transmit) Data Rate Downstream: 30.432 Mbps (64-QAM), 42.88 Mbps (256-QAM) Upstream: 320, 640, 1280, 2560, 5120 kbps (QPSK), 640, 1280, 5560, 5120, 10240 kbps (16-QAM) Frequency Range Downstream: 91 MHz ~ 857 MHz Upstream:5 MHz ~ 42 MHz Bandwidth Downstream: 6 MHz Upstream: 200 kHz, 400 kHz, 800 kHz, 1.6 MHz, 3.2 MHz Input Signal Single Channel: -15 dBmv ~ +15 dBmv Total: < +30 dBmv Output Signal +8 dBmv ~ +58 dBmv (QPSK ...
• Confirm that you have established an account with your service provider and that a two-way cable service is provided. • Check that all cables are connected to the modem and PC. Verify that the proper cable type is used and its length does not exceed specified limits. Check the cable connections for possible defects. Replace the defective cable if necessary. • Verify that the modem and computer are powered on. • If the power source has a switch, ensure that it is switched on. • Check the power outlet by plugging in another device that is functioning properly. • Check the powe ...
10 Port and Cable Assignments Caution: DO NOT plug a phone jack connector into any RJ-45 port. Use only twisted-pair cables with RJ-45 connectors that conform with FCC standards. An Ethernet twisted-pair link segment requires two pairs of wires. Each wire pair is identified by two different colors. Each wire pair must be attached to the RJ-45 connector in a specific orientation detailed below. The Ethernet port on the modem is an MDI-X port, which allows straight-through cable connections to PCs, and to hubs and switches with MDI ports. In straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are connected strai ...
11 Straight-Through Wiring If the twisted-pair cable is to join two ports and only one of the ports has an internal crossover (MDI-X), the two pairs of wires must be straight-through. Crossover Wiring If the twisted-pair cable is to join two ports and either both ports are labeled with an “X” (MDI-X) or neither port is labeled with an “X” (MDI), a crossover must be implemented in the wiring. Straight-Through RJ-45 Pin Assignments End 1 End 2 1 (RD+) 1 (TD+) 2 (RD-) 2 (TD-) 3 (TD+) 3 (RD+) 6 (TD-) 6 (RD-) Crossover RJ-45 Pin Assignments End 1 End 2 1 (TD+) 3 (RD+) 2 (TD-) 6 (RD-) 3 (RD+) 1 (TD+) 6 (RD-) 2 (TD-) ...
12 EMI Certification FCC Class B Certification (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate ra ...
This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/ EEC. For the evaluation of the compliance with these Directives, the following standards were applied: Warning! Do not plug a phone jack connector in the RJ-45 port. This may damage the device. Les raccordeurs ne sont pas utilisé pour le système téléphonique! RFI Emission: • Limit class ...
14 Safety Compliance Underwriters Laboratories Inc. (USA) Important! Before making connections, make sure you have the correct Cord Set. Check it (read the label on the cable) against the following specification list. Operating Voltage Cord Set Specifications 120 Volts UL Listed/CSA Certified Cord Set Minimum 18 AWG Type SVT or SJT three conductor cord Maximum length of 15 feet Parallel blade, grounding type attachment plug rated 15 A, 125 V 240 Volts (Europe only) Cord Set with H05VV-F cord having three conductors with minimum diameter of 0.75 mm2 IEC-320 receptacle Male plug rated 10 A, 250 V ...
be free from defects in material and workmanship for a period of three (3) years from the date of purchase from SMC or its Authorized reseller. For the warranty to apply, you must register your purchase by returning the registration card indicating the date of purchase and including proof of purchase. There will be a minimal charge to replace consumable components, such as fuses, power transformers, and mechanical cooling devices. The warranty does not cover the product if it is damaged in the process of being installed. SMC recommends that you have ...
From U.S.A. and Canada (24 hours a day, 7 days a week) (800) SMC-4-YOU; (949) 679-8000; Fax: (949) 679-1481 From Europe (8:00 AM - 5:30 PM UK Time) 44 (0) 118 974 8700; Fax: 44 (0) 118 974 8701 INTERNET E-mail addresses: [email protected] [email protected] Driver updates: http://www.smc.com/index.cfm?action=tech support drivers downloads World Wide Web: http://www.smc.com/ http://www.smc-europe.com/ FOR LITERATURE OR ADVERTISING RESPONSE, CALL: U.S.A. and Canada: (800) SMC-4-YOU; Fax (949) 679-1481 Spain: 34-93-477-4935; Fax 34-93-477-3774 UK: 44 (0) 118 974 8700; Fax 44 (0) 118 974 8701 France: 33 ( ...
Modem PDF Instructions
Step-by-step user manual for the ZyXEL Communications eir F1000 Modem. This guide includes detailed instructions for startup procedures, installation steps, operational safety.
Cisco Model DPC3212 and EPC3212 VoIP Cable Modem User Guide In This Document IMPORTANT SAFETY INSTRUCTIONS ...............................................................2 Introduction...................................................................... Technical operations guide for the Cisco DPC3212 Modem. This guide includes hardware instructions, usage tips, device reset instructions.
Troubleshooting Legal Notice Issue: 02 (2009-10-10) Part Number: 00405272 EchoLife BM635 WiMAX C 8 9 Quick Sta 1 Configuring the VoIP Service 3 Viewing the Status Information about the CPE The status information about the CPE includes the device information, Product usage manual for the Huawei BM635 Modem. The documentation includes maintenance schedule, product safety, operational guidelines, user preferences.
Copyright © 2008 Huawei Technologies Co., Ltd. All Rights Reserved No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and Permissions and other Huawe Product documentation for the Huawei E160G Modem. It explains usage scenarios and error codes, usage procedures, software updates.