Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com

EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: RD0287 (A) JF60z June 2005 J F 6 0 z S p e c i f i c a t i o n s group · J DESCRIPTION • Compact loudspeaker with no compromise in sound quality • For portable use or permanent installation • 100° conical beamwidth • Passive crossover for single amplifier operation The JF60z is an ultra compact loudspeaker, engineered for exceptional, near-field performance. It provides surprisingly high output and exceptional fidelity for foreground and background music applications. It's speech projection capabilities also make it very effective as a fill or delay element in larger audio systems. Unlike many compact loudspeakers, the JF60z produces the high impact, high definition sound projection expected in professional PA applications. Its wide angle projection makes audience coverage easy in a variety of situations. While the JF60z is well suited as is for many applications, the addition of a subwoofer can expand its capabilities for more demanding applications. Foam-backed grilles hide the drivers from view for pleasing aesthetics. Top, bottom and side mounting points allow enclosures to be mounted in virtually any configuration using eyebolts or accessory brackets. Additional mounting points accept an OmniMount® 30.0 Series or similar bracket and a third-party, external, stand adapter for pole mounting, such as the K&M™ 195/8 or Ultimate Support™ BMB-200K. Standard colors are black and white. Other colors can be specified as a special order items. The diverse applications for the JF60z include: band PA, multimedia systems, retail spaces, presentation suites, shopping malls, smaller houses of worship, theatres, auditoriums, lecture halls, and theme parks. Fill/delay applications include arenas, stadiums, concert halls, theatres, and houses of worship. Six year warranty. 2-WAY FULL-RANGE See NOTES TABULAR DATA for details CONFIGURATION Subsystem Transducer Loading LF 1x 6.5 in cone Sealed HF 1x 1.3 in dome Waveguide Plate™ Operating Mode Amplifier Channels External Signal Processing Single-amp LF/ HF HPF PERFORMANCE 1 Operating Range 83 Hz to 20 kHz Nominal Beamwidth (rotatable) Horz 100° Vert 100° Axial Sensitivity (whole space SPL) LF/HF 88 dB 83 Hz to 20 kHz Input Impedance (ohms) Nominal Minimum LF/HF 8 7.4 @ 220 Hz Input Taps (MT version) 70 V 100 V LF/HF 64 W / 32 W / 16 W 64 W / 32 W High Pass Filter High Pass =>70 Hz, 12 dB/octave Butterworth Accelerated Life Test 2 LF/HF 40 V 200 W @ 8 ohm Calculated Axial Output Limit (whole space SPL) Average Peak LF/HF 111 dB 117 dB ORDERING DATA Description Part Number JF60z 2-Way Full-Range Loudspeaker Black 0012618 JF60z 2-Way Full-Range Loudspeaker White 0013768 JF60zMT Multi-tap 70/100 V Transformer Black 0013770 JF60z-16 16 ohm Black 0013794 JF60zPL-WP Weather Protected Black 0014359 Optional Accessories Eyebolt/Forged Shoulder (1/4-20 x 1 in) 104009 U-Bracket Black 0012360 U-Bracket White 0012362 Yoke Bracket Black 0012388 Yoke Bracket White 0012393 1 To achieve specified performance, the listed external signal processing with EAW-provided settings is required. 2 For recommendations to select power amplifier size refer to : “HOW MUCH AMPLIFIER POWER DO I NEED?” on the EAW web site.

Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com

EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: RD0287 (A) JF60z June 2005 J F 6 0 z S p e c i f i c a t i o n s group · J ENCLOSURE Material Baltic birch plywood (Celtec® for JF60zPL-WP) Finish Wear resistant textured black paint Grille Powder-coated perforated steel with foam backing EASTERN ACOUSTIC WORKS PRODUCTION 20° [108.0] 4.25 NOT TO SCALE R 11.58 [R 294.2] [119.2] TOP (4.69) TSC BACK FRONT BOTTOM A A 7.00 L [177.8] VIEW A-A DIMENSIONS APPLY TO BOTH SIDES C [53.8] 2.12 [190.5] 7.50 INPUT [199.0] [246.8] 9.72 NOTES: 1. SYMBOL INDICATES MOUNTING POINT, 5/16-18 T-NUT FOR OMNI MOUNT 30.0 SERIES. 2. SYMBOL INDICATES MOUNTING POINT, 5/16-18 T-NUT FOR ULTIMATE BRAND STAND. 3. SYMBOL INDICATES MOUNTING POINT, 1/4-20 THREADED HOLE. 4. SYMBOL INDICATES CENTER OF BALANCE. 5. WEIGHT APPROX. 17.20 lb [7.7 kg ] 6. SHIPPING WEIGHT APPROX. 22.00 lb [9.9 kg ]. [371.5] 7.83 [2X115.8] 2X 4.56 [133.4] 5.25 [59.9] [108.0] 4.25 JF60z C L C 2.36 L 14.63 GRILLE PARTIALLY SHOWN L C 2.00 [50.8] 1.12 [28.5] 7.00 [177.8] 6.41 [162.7] NOTE: This drawing has been reduced. Do not scale. For WP version, add 0.25 in / 6.4 mm to the outside dimensions = 0.125 in / 3.2 mm all around.

Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com

EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: RD0287 (A) JF60z June 2005 J F 6 0 z S p e c i f i c a t i o n s group · J PERFORMANCE DATA See NOTES GRAPHIC DATA for details Frequency Response: Processed with HPF LF/HF = blue SPL (dB) Frequency Response: Unprocessed LF/HF = blue SPL (dB) Frequency Response: Recomended High Pass Filter LF/HF = blue dB re 0.775 V Beamwidth (-6 dB SPL Points) Horizontal = orange Vertical = black Degrees Impedance Magnitude LF/HF = blue Ohms 110 100 90 80 70 60 50 100 10 1 400 100 10 1 100 1000 20000 Frequency (Hz) 10 100 1000 20000 Frequency (Hz) 10 0 -10 -20 -30 -40 -50 20 10 0 -10 -20 -30 -40 10 100 1000 20000 Frequency (Hz) 10 100 1000 20000 Frequency (Hz) 10 100 1000 20000 Frequency (Hz)

Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com

EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: RD0287 (A) JF60z June 2005 J F 6 0 z S p e c i f i c a t i o n s group · J 0 -45 -90 -135 180 135 90 45 100 Hz 125 Hz 160 Hz 200 Hz 0 -45 -90 -135 180 135 90 45 250 Hz 315 Hz 400 Hz 500 Hz 0 -45 -90 -135 180 135 90 45 630 Hz 800 Hz 1000 Hz 1250 Hz 0 -45 -90 -135 180 135 90 45 1600 Hz 2000 Hz 2500 Hz 3150 Hz 0 -45 -90 -135 180 135 90 45 4000 Hz 5000 Hz 6300 Hz 8000 Hz 0 -45 -90 -135 180 135 90 45 10000 Hz 12000 Hz 16000 Hz HORIZONTAL POLAR DATA (Gridlines: 6 dB axial / 15 degree radial) See NOTES GRAPHIC DATA for details

Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com

EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: RD0287 (A) JF60z June 2005 J F 6 0 z S p e c i f i c a t i o n s group · J VERTICAL POLAR DATA (Gridlines: 6 dB axial / 15 degree radial) See NOTES GRAPHIC DATA for details 0 -45 -90 -135 180 135 90 45 100 Hz 125 Hz 160 Hz 200 Hz 0 -45 -90 -135 180 135 90 45 250 Hz 315 Hz 400 Hz 500 Hz 0 -45 -90 -135 180 135 90 45 630 Hz 800 Hz 1000 Hz 1250 Hz 0 -45 -90 -135 180 135 90 45 4000 Hz 5000 Hz 6300 Hz 8000 Hz 0 -45 -90 -135 180 135 90 45 10000 Hz 12000 Hz 16000 Hz 0 -45 -90 -135 180 135 90 45 1600 Hz 2000 Hz 2500 Hz 3150 Hz

Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com

EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: RD0287 (A) JF60z June 2005 J F 6 0 z S p e c i f i c a t i o n s group · J INPUT PANEL S/N WHITINSVILLE, MA USA PIN 1--...-- PIN 1+...+ + -- JF60z NOTES TABULAR DATA 1. Measurement/Data Processing Systems: Primary - FChart: proprietary EAW software; Secondary - Brüel & Kjær 2012. 2. Microphone Systems: Earthworks M30; Brüel & Kjær 4133 3. Measurements: Dual channel FFT; length: 32 768 samples; sample rate: 48 kHz; logarithmic sine wave sweep. 4. Measurement System Qualification (includes all uncertainties): SPL: accuracy +/-0.2 dB @ 1 kHz, precision +/-0.5 dB 20 Hz to 20 kHz, resolution 0.05 dB; Frequency: accuracy +/-1 %, precision +/-0.1 Hz, resolution the larger of 1.5 Hz or 1/48 octave; Time: accuracy +/-10.4 µs, precision +/-0.5 µs, resolution 10.4 µs; Angular: accuracy +/-1°, precision +/-0.5°, resolution 0.5°. 5. Environment: Measurements time-widowed and processed to eliminate room effects, approximating an anechoic environment. Data processed as anechoic or fractional space, as noted. 6. Measurement Distance: 7.46 m. Acoustic responses represent complex summation of the subsystems at 20 m. SPLis referenced to other distances using the Inverse Square Law. 7. Volts: Measured rms value of the test signal. 8. Watts: Per audio industry practice, “loudspeaker watts” are calculated as voltage squared divided by rated nominal impedance. Thus, these are not True Watt units of energy as defined by International Standard. 9. SPL: (Sound Pressure Level) Equivalent to the average level of a signal referenced to 0 dB SPL = 20 microPascals. 10. Subsystem: This lists the transducer(s) and their acoustic loading for each passband. Sub = Subwoofer, LF = Low Frequency, MF = Mid Frequency, HF = High Frequency. 11. Operating Mode: User selectable configurations. Between system elements, a comma (,) = separate amplifier channels; a slash (/) = single amplifier channel. DSP = Digital Signal Processor. IMPORTANT: To achieve the specified performance, the listed external signal processing must be used with EAW-provided settings. 12. Operating Range: Range where the processed Frequency Response stays within -10 dB SPL of the power averaged SPL within this range; measured on the geometric axis. Narrow band dips are excepted. 13. Nominal Beamwidth: Design angle for the -6 dB SPL points, referenced to 0 dB SPL as the highest level. 14. Axial Sensitivity: Power averaged SPL over the Operating Range with an input voltage that would produce 1 W at the nominal impedance; measured with no external processing on the geometric axis, referenced to 1 m. 15. Nominal Impedance: Selected 4, 8, or 16 ohm resistance such that the minimum impedance point is no more than 20% below this resistance over the Operating Range. 16. Accelerated Life Test: Maximum test input voltage applied with an EIA-426B defined spectrum; measured with recommended signal processing and Recommended Protection Filter. 17. Calculated Axial Output Limit: Highest average and peak SPLs possible during the Accelerated Life Test. The Peak SPL represents the 2:1 (6 dB) crest factor of the Life Test signal. 18. High Pass Filter: This helps protect the loudspeaker from excessive input signal levels at frequencies below the Operating Range. GRAPHIC DATA 1. Resolution: To remove insignificant fine details, 1/12 octave cepstral smoothing was applied to acoustic frequency responses and 1/3 octave cepstral smoothing was applied to the beamwidth and impedance data. Other graphs are plotted using raw data. 2. Frequency Responses: Variation in acoustic output level with frequency for a constant input signal. Processed: normalized to 0 dB SPL. Unprocessed inputs: 2 V (4 ohm nominal impedance), 2.83 V (8 ohm nominal impedance), or 4 V (16 ohm nominal impedance) referenced to a distance of 1 m. 3. Processor Response: The variation in output level with frequency for a constant input signal of 0.775 V = 0 dB reference. 4. Beamwidth:Average angle for each 1/3 octave frequency band where, starting from the rear of the loudspeaker, the output first reaches -6 dB SPL referenced to 0 dB SPL as the highest level. This method means the output may drop below -6 dB SPL within the beamwidth angle. 5. Impedance: Variation in impedance magnitude, in ohms, with frequency without regard to voltage/current phase. This means the impedance values may not be used to calculate True Watts (see 9 above). 6. Polar Data: Horizontal and vertical polar responses for each 1/3 octave frequency band 100 Hz to 16 kHz or Operating Range. AMP 2-Way, Single-Amp (LF/HF) XVR LF HF HPF 70 V / 100 V AMP 2-Way, Single-Amp (LF/HF) MT XVR LF HF HPF SIGNAL DIAGRAM LEGEND DSP: User-supplied Digital Signal Processor. HPF: High Pass Filter for crossover or Recommended High Pass Filter. LPF: Low Pass Filter for crossover. LF/MF/HF: Low Frequency / Mid Frequency / High Frequency. AMP: User-supplied Power Amplifier. XVR: Passive LPFs, HPFs, and EQ integral to the loudspeaker. MT version input drawing unavailable