Smeg CWC500R Operation & User’s Manual
Text of the manual
LAVASTOVIGLIE PROFESSIONALE CWC500R
PROFESSIONAL DISHWASHER CWC500R
LAVE-VAISSELLE PROFESSIONNEL CWC500R
PROFESSIONELLER GESCHIRRSPÜLER CWC500R
LAVAVAJILLAS PROFESIONAL CWC500R
MÁQUINA DE LAVAR LOUÇA PROFISSIONAL CWC500R
1 Safety and usage instructions
2 Technical characteristics
3 Installation and positioning
4 INSTALLER – TECHNICAL ASSISTANT INSTRUCTIONS
5 First startup
6 Settings
7 Screen-displayed anomalies (technical)
8 USER INSTRUCTIONS
9 Program selection
10 Maintenance and cleaning
11 Problems and anomalies (user)
12 Screen-displayed anomalies (user)
Thank you for
1 Safety and usage instructions
THE DISHWASHER IS INTENDED EXCLUSIVELY FOR PROFESSIONAL USE AND MUST BE USED BY
COMPETENT PERSONNEL. IT IS DESIGNED TO WASH DISHES (PLATES, CUPS, BOWLS, BAKING
PANS, SILVERWARE) AND SIMILAR ITEMS FROM THE GASTRONOMY AND THE COLLECTIVE
RESTAURANT INDUSTRIES. IT CONFORMS TO THE INTERNATIONAL ELECTRIC AND MECHANICAL
SAFETY NORM
Input voltage power
V
400V 3N ~
- transformable to version
V
230V-3 ~
Frequency
Hz
50
Max. absorbed power at 400V 3N ~
kW
11,1
Boiler resistance power at 400V 3N ~
kW
10,0
Tank resistance power
kW
3,0
Water supply pressure
kPa (bar)
200-400 (2 ÷ 4)
Water supply temperature
°C
50°C – 60°C
W
5
.
Allacciamento elettrico
Electrical connection
Branchement electrique
Elektroanschluss
Morsetto equipotenziale
Equipotential termical
Bome equipotential
Potentialaausgleichklemme
Non in dotazione
Not equipped
Pas en dotation
Nicht dabei
Morsettiera
Terminal board
Plaques a bornes
Klemmenbrett
V
Ingresso acqua calda
Hot water inlet
Entr�
3 Installation and positioning
INSTALLATION and POSITIONING
Bring the dishwasher to its installation location, remove its packaging and verify the integrity of the apparatus
and of the components. If damaged, written notification must be sent to the transporter.
The packaging elements (plastic bags, polystyrene foam, nails, etc) must not be left within rea
4.1 Electrical connection
The dishwasher’s electrical connection and that of eventual supplementary apparatus is to be
entrusted to authorized and qualified personnel, with respect to the norms in vigor; observe also the
technical regulations for the connections.
The total power installed is given upon the apparatus’ technical data label.
Other apparat
6 SETTINGS (only models CW400RSD - CW400R – CWC500R)
MACHINE CONFIGURATION PARAMETERS ( Intended for technical personnel, not for the user )
P0
RINSE CYCLE TIME, from 1 to 5 minutes, preset to 2
P1
BOILER TEMPERATURE, from 60 to 95 °C, preset to 86 °C
P2
TANK TEMPERATURE, from 40 to 65 °C, preset to 55 °C
P3
RINSE DURATION from 10 to 40 sec., preset