smeg wallmount rangehood, 60cm

ID200410 Code K181X60 dimensions 600mm W x 496mm D x 1190mm H maximum finish satin stainless steel installation wallmount motor 190 watt centrifugal, twin impellors, double-sided air uptake capacity 5903m/hr net noise rating 29–50 dBA extraction direct duct ot recirculate illumination two x 20 watt halogen globes, separate ON/OFF buttons speeds three separate buttons filtration 2 x stainless steel/aluminium 4-ply grease filters, removable, warm hand wash warranty two years parts and labour PERFORMANCE Highly-efficient air extraction of up to 590 cubic metres an hour true (net) ensures the very swift removal of cooking vapours, odours and heat. The higher speed selections are perfect for the more vigorous styles of cooking such as stir frying, griddle cooking and boiling, the lower speeds at the touch of a button are perfect for simmers. QUIETNESS 29 to 50 dBA. The motor/impellor encasements are smooth-walled to minimise air drag and, hence, noise. All metal joins are welded to reduce vibration. SAFETY Thermal overload protection on motor, fire retardant hardened metal and mesh, VO self-extinguishing plastic for motor housing and internal flue. MAINTENANCE No tools required — easy lift-out pair of grease filters for washing. For light replacement, simply rotate the decorative flange for access to halogen globes. DUCTING Direct ducting to atmosphere ensures the maximum removal of grease/ oil/particle-laden vapour plus the odours and, very importantly, the heat, resulting in a cleaner, cooler, more comfortable work area. RECIRCULATION When the cooking vapours cannot be ducted to atmosphere, the filtered air can simply be redirected back into the kitchen via a duct pipe through the overhead cabinetry. CHARCOAL FILTERS This is a purchasable accessory. It is inserted just below the centrifugal motor and is designed to absorb and diminish cooking odours. Periodic inspection is recommended before replacement. The activated charcoal filter is optionally used for recirculation only. Charcoal filters are not to be washed. The are replaceable. DUCTING MATERIAL Smooth internal walled duct pipe lengths ensure the most efficient air movement and quieter operation. Consider either high temperature rated PVC or galvanised sheet metal piping. The flexible ducting cab be ideal for a very short, tight run. The rangehood’s air exit aperture is designed for 150mm (6”) ducting; however, a 125mm diameter (5”) adaptor can be purchased for optional use. DELAY STOP Ideally, a rangehood should run for several minutes after all cooking is ceased in order to drag through residual vapours and odours. By selecting the delay stop button at the end of the cooking, the rangehood will turn the motor off in five minutes as well as the lights if they were left on. CLEANING PROMPT After 30 hours use the LED window will prompt visually to inspect the grease filters for possible cleaning. Simply use the Reset button to clear the LED window.

smeg wallmount rangehood, 60cm

ID200410 Code K181X60 WARNING: technical specifications and product sizes can be varied by the manufacturer, without notice. Cutouts for appliances should only be by physical product measurements. The above information is indicative only. NB: drawings are not to scale — they are to assist only electricity supply 240 volt, 50 Hz electrical connection 1.5 metre connected power cord for plugging to standard 10 amp GPO wattage 190 watt motor, 2 x 20 watt halogen globes, 230 watts total current 0.96 amps packaged dimensions 710mm x 470mm x 630mm = 0.21m³ gross weight 19.2kg net weight 16.5 kg supplied NB: • instructions for installation, operation, maintenance • one-way butterfly valve for optional fitment to air exit aperture • fixing screws • 150mm/125mm diameter ducting adaptor • recirculation diverter kit — direct ducting to atmosphere requires 150mm diameter ducting — recirculation to kitchen requires 125mm diameter ducting option activated charcoal filter for optional fitment in recirculation installation, part number 08999802 SPEED 1 2 3 net air capacity m3/hr 205 310 590 pressure mm H20 12 25 39 input wattage 45 85 190 noise dBA 29 34 50 direct ducting to atmosphere recirculation to kitchen chimney plan detail PLEASE NOTE the difference in maximum heights between the ‘direct duct to atmosphere’ installation and the ‘recirculation’ installation. The recirculation installation’s maximum height is 1190mm due to the active recirculation vents necessarily being exposed on each side of the chimney. The ‘direct duct to atmosphere’ installation shows the now redundant recirculation vents being concealed by the lower chimney by reversing — that is, turning the upper chimney piece 180 degrees on the vertical. If a higher chimney height is required for the ‘direct duct to atmosphere’ installation, that is, up to 1190mm, simply follow the ‘recirculation’ installation and have the recirculation vents exposed, though redundant. 253 278 97 150 min 470 min 650 278 253 600 496 60 510 min 680 — max 1000 min 110 max 430 600 496 510 min 770 — max 1190 min 200 max 620 253 278

Other Ventilation Hood Manuals