Owner’s Manual Model Nos. 2001/3001 Commercial Jump Starter/Chargers READ ENTIRE MANUAL CAREFULLY BEFORE OPERATING UNIT! WARNING Made in U.S.A. ...
Keep the unit plugged in when not in use and it will provide long, continuous service and satisfaction. The SOLAR Jump Starter/Charger is specifically designed to jump start and/or charge 12 Volt lead-acid batteries. Follow all battery/vehicle manufacturer's jump starting or charging instructions. Our units will deliver 600 Amp-1000 Amp starting power depending upon the model and battery installed. DO NOT JUMP START WITH AC POWER CORD CONNECTED TO 110 VOLT AC POWER SOURCE. The unit’s charger will maintain the it’s internal battery and recharge most ...
or injury to persons. 2. To reduce risk of damage to electric plug and cord, pull by plug rather than cord when disconnecting unit. 3. Make sure cord is located so that it will not be stepped on, tripped over, or otherwise subjected to damage or stress. 4. An extension cord should not be used unless absolutely necessary. Use of an improper extension cord could result in a risk of fire and electric shock. If an extension cord must be used, make sure pins on plug of extension cord are the same number, size, and shape as those ...
BATTERY SELECTION 1. Battery Size (Group) to Use: Model No. 2001 – Group 31 1000 CCA and up Model No. 3001 – Group 31 1000 CCA and up 2. A high quality battery will last longer and perform better than a marginal quality battery. 3. Use a battery with a sealed top or with screw type flush fill caps. This will help prevent acid leakage should unit be inadvertently laid flat or turned over. 4. Use battery with 3/8" threaded studs. 5. A high quality battery emits less gases as it recharges. Using this type of battery will extend charger and wiring life. Battery acid and petroleum resistant wiring is used in this uni ...
Warning: DO NOT JUMP START WHILE THE UNIT IS PLUGGED INTO 110 AC POWER SOURCE! NEVER JUMP START A FROZEN BATTERY! A SPARK NEAR BATTERY MAY CAUSE BATTERY EXPLOSION – FOLLOW INSTRUCTIONS BELOW TO REDUCE RISK OF A SPARK NEAR BATTERY. 1. Position DC jumper cables to reduce risk of damage by hood, door, or moving engine part. 2. Stay clear of fan belts, pulleys, and other parts that can cause injury to persons. 3. Check polarity of battery posts. POSITIVE (POS, P, +) and NEGATIVE (NEG, N, –). 4. Determine which post of battery is grounded (connected) to the chassis. If negative post is grounded ...
(Model No. 3001 Only) Warning: DO NOT INFLATE TIRES OR FLIP AIR COMPRESSOR "ON/OFF" SWITCH WHILE THE UNIT IS PLUGGED INTO 110 AC POWER SOURCE! 1. Snap air chuck on tire valve stem (some wheel covers may require use of valve stem extension). 2. Flip "ON/OFF" air switch on front panel to "ON" position. 3. Tire will inflate to preset pressure and compressor will shut off. 4. Disconnect air chuck from tire valve stem (compressor will come on again). 5. Flip "On/Off" air switch on front panel to "Off" position. 6. See Compressor section below to adjust shut off pressure. Adjusting the Compressor Shut Off Pressure 1. R ...
POSSIBLE CAUSE SOLUTION Poor grip connection Check grip connection Low/defective battery Load test/charge/replace battery Loose jumper cable connection to battery Tighten battery connections PROBLEM: Unit does not charge. POSSIBLE CAUSE SOLUTION Poor grip connection Check grip connection Faulty 110 AC outlet Check or change outlet Bad plug on unit Check continuity of plug pins/replace plug Loose/defective connections Check unit for loose connections Defective amp gauge Replace gauge Faulty charger Replace charger PROBLEM: Unit does not inflate tires. POSSIBLE CAUSE SOLUTION Low/defective battery ind ...
© 2006 Clore Automotive 841-023-000 LIMITED WARRANTY Clore Automotive, LLC warrants your SOLAR Commercial Jump Starter/Charger to be free from defects in material and workmanship for a period of one year from the date of sale to the original user or consumer purchaser. If your SOLAR Commercial Jump Starter/ Charger malfunctions or fails within the first 30 days of the warranty period because of a defect in material or workmanship, we will replace it. If your SOLAR Commercial Jump Starter/Charger malfunctions or fails within the 12 month warranty period be ...
Please complete the attached registration card to be eligible to receive FREE technical support, product updates and warranty service. TECHNICAL SUPPORT Technical support is available to registered users only. Call (800) 328-2921 Monday through Friday, 8:00 AM to 4:30 PM CST. THREE EASY WAYS TO REGISTER 1. Mail in the completed registration card below OR 2. Fax the completed registration card to (800) 716-6531 OR 3. Register your product online at www.cloreregistration.com. WARRANTY AND TECHNICAL SUPPORT REGISTRATION CARD Model Number:____________________________________________________ Date of purchase:___/_ ...
LENEXA KS 66215-9901 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST-CLASS MAIL PERMIT NO. 5445 SHAWNEE MISSION KS POSTAGE WILL BE PAID BY ADDRESSEE ...
Battery Charger PDF Instructions
1 Mikroport® System 2015 Bedienungsanleitung Instructions for use Notice d’emploi Istruzioni per l’uso Instrucciones de uso Gebruiksaanwijzing Reference manual for the Sennheiser L 2015 Other. It contains information on control functions, setup, network setup, usage procedures.
CRG-01603P Li-ion Battery Charger User Manual AEGIS ENERGIES INC. (dba: Aegis Battery) Your Battery Specialist! Contact Us Mail: Aegis Energies 13321 Garden Grove Blvd, Unit F Garden Grove, CA 92843 Phone: +1 (657) 296-6981 Fax: +1 (657) 296-6981 Email: contac Setup instructions for the Aegis CRG-01603P Battery Charger. It details device setup and usage tips, setup instructions, menu navigation.
Product instruction handbook for the Energic PlusPlus MVM Battery Charger. It explains usage scenarios and interface navigation, performance details, testing procedures, installation support.
STANDARD UNITS 12V, 24V, 48V 15A, 30A, 60A WOODS BATTERY CHARGERS Issue : 2.00 DIALOcharge MANUALLY OPERATED MULTI-VOLTAGE LEAD-ACID BATTERY CHARGER Complete user documentation for the Woods Dialocharge D1230 Battery Charger. The manual highlights network setup, technical specifications, assembly reference.