Schottky Barrier Diodes (SBD)

Publication date: December 2004 SKH00144AED 1 MA4SD05X Silicon epitaxial planar type For high-speed switching circuits  Features  Features   Two isolated elements are contained in one package, allowing high-density  Two isolated elements are contained in one package, allowing high-density  mounting  Optimum for high frequency rectifi cation because of its short reverse recovery  Optimum for high frequency rectifi cation because of its short reverse recovery  time trr time trr time t  Absolute Maximum Ratings  Absolute Maximum Ratings  Ta = 25 a = 25 a °C Parameter Symbol Rating Unit Reverse voltage VR 45 V Maximum peak reverse voltage VRM VRM V 45 V Forward current *1 IF 100 mA Peak forward current *1 IFM 300 mA Non-repetitive peak forward surge current *1, 2 IFSM 1 A Junction temperature TjTjT 125 °C Storage temperature Tstg Tstg T –55 to +125 °C Note) *1: Value for single diode *2: 50 Hz sine wave 1 cycle (Non-repetitive peak current)  Electrical Characteristics  Electrical Characteristics  Ta = 25 a = 25 a °C±3°C Parameter Symbol Conditions Min Typ Max Unit Forward voltage VF1 VF1 V IF = 1 mA 0.27 V VF2 VF2 V IF = 10 mA 0.35 VF3 VF3 V IF = 100 mA 0.54 0.60 Reverse current IR VR = 40 V R = 40 V R 5 µA Terminal capacitance Ct VR = 0 V, f = 1 MHz R = 0 V, f = 1 MHz R 12 18 pF Reverse recovery time * trrtrrt IF = IR = 100 mA, I R = 100 mA, I R rr = 10 mA rr = 10 mA rr RL RL R = 100 L = 100 L Ω 2.0 ns Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes. 2. Absolute frequency of input and output is 250 MHz 2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body and the leakage of current from the operating equipment. 3. *: trr measurement circuit rr measurement circuit rr Marking Symbol: M5C Internal Connection Unit: mm 1: Anode 1 2: Anode 2 3: Cathode 2 4: Cathode 1 SSMini4-F1 Package 1.6±0.05 5° 1.0±0.05 1.15±0.05 0.01±0.01 1.6±0.1 0.25±0.05 0.55±0.1 0.10±0.03 1 2 5° (0.225) (0.15) 4 3 1 2 3 4 This product complies with the RoHS Directive (EU 2002/95/EC).

IF  V

 V  F VF V IR  V  V  R C R C R t  V  V  R VR V 0 0.4 0.8 1.2 103 102 10 1 10−1 10−2 10−3 MA4SD05X_ IF-VF Forward current IF (mA) Forward voltage VF (V) Ta = 125°C 75°C 25°C 0 20 40 60 103 102 10 1 10−1 10−2 MA4SD05X_ IR-VR Reverse current IR (µA) Reverse voltage VR (V) Ta = 125°C 75°C 25°C 0 20 40 60 25 20 15 10 5 0 MA4SD05X_ Ct-VR Terminal capacitance Ct (pF) Reverse voltage VR (V) Ta = 25°C This product complies with the RoHS Directive (EU 2002/95/EC).

Request for your special attention and precautions in using the technical information and

semiconductors described in this book (1)If any of the products or technical information described in this book is to be exported or provided to non-residents, the laws and regulations of the exporting country, especially, those with regard to security export control, must be observed. (2)The technical information described in this book is intended only to show the main characteristics and application circuit examples of the products, and no license is granted under any intellectual property right or other right owned by our company or any other company. Therefore, no responsibility is assumed by our company as to the infringement upon any such right owned by any other company which may arise as a result of the use of technical information described in this book. (3)The products described in this book are intended to be used for standard applications or general electronic equipment (such as office equipment, communications equipment, measuring instruments and household appliances). Consult our sales staff in advance for information on the following applications: – Special applications (such as for airplanes, aerospace, automobiles, traffic control equipment, combustion equipment, life support systems and safety devices) in which exceptional quality and reliability are required, or if the failure or malfunction of the prod- ucts may directly jeopardize life or harm the human body. – Any applications other than the standard applications intended. (4)The products and product specifications described in this book are subject to change without notice for modification and/or im- provement. At the final stage of your design, purchasing, or use of the products, therefore, ask for the most up-to-date Product Standards in advance to make sure that the latest specifications satisfy your requirements. (5)When designing your equipment, comply with the range of absolute maximum rating and the guaranteed operating conditions (operating power supply voltage and operating environment etc.). Especially, please be careful not to exceed the range of absolute maximum rating on the transient state, such as power-on, power-off and mode-switching. Otherwise, we will not be liable for any defect which may arise later in your equipment.  Even when the products are used within the guaranteed values, take into the consideration of incidence of break down and failure mode, possible to occur to semiconductor products. Measures on the systems such as redundant design, arresting the spread of fire or preventing glitch are recommended in order to prevent physical injury, fire, social damages, for example, by using the products. (6)Comply with the instructions for use in order to prevent breakdown and characteristics change due to external factors (ESD, EOS, thermal stress and mechanical stress) at the time of handling, mounting or at customer's process. When using products for which damp-proof packing is required, satisfy the conditions, such as shelf life and the elapsed time since first opening the packages. (7)This book may be not reprinted or reproduced whether wholly or partially, without the prior written permission of Matsushita Electric Industrial Co., Ltd.