Paradyne 4000E Installation Instructions Manual
Read Online
Read the Paradyne 4000E Installation Instructions Manual online using the built-in PDF viewer.
Key Pages of Document
Installation Instructions Document Number IPD4-A2-GZ40-10 July 2005 Contents Software and Firmware License Agreement ...................................................... 1 Introduction ........................................................................................................ 3 Unpacking and Inspecting the Equipment ......................................................... 3 Install ...
executed a separate written agreement covering the Software supplied to you under this purchase, such separate written agreement shall govern. Paradyne Corporation (“Paradyne”) grants to you, and you (“Licensee”) agree to accept a personal, non-transferable, non-exclusive, right (without the right to sublicense) to use the Software, solely ...
Software and destroy the original and all copies of the Software in the possession of Licensee together with all documentation and related materials. 10. This Agreement shall be governed by the laws of the State of Florida, without regard to its provisions concerning conflicts of laws. Introduction Paradyne's 4000E IP Broadband Loop Carrier (BLC) pr ...
10 – #6 Phillips Bracket Screws 8 – #10 Phillips Rack Screws 8 – #12 Phillips Rack Screws If there is visible damage, do not attempt to connect the device. Contact your sales representative. Installation Options The 4000E BLC is designed for installation in a Restricted Access area where admittance is limited to trained and authorized service personel. I ...
Using a Phillips Screwdriver, attach the two [2] provided rack mount brackets to the sides of the 4000E with eight [8] of the ten [10] provided bracket screws. There are seven position options for the rack brackets; position them as best suited to the space available for your chassis on the rack being utilized. Mount the chassis onto the rack and secure the rack mount brackets to the sides of the rack usin ...
A management module provides the functional control for the 4000E BLC; the 4000E cannot function without one. There are several different models available for purchase. Refer to www.paradyne.com for further information, or contact your sales representative. Installing a Management Module An uplink module provides the upstream network connection for the 4000E BLC; a management module cannot funct ...
screws on the management module faceplate. Installing Your Interface Module(s) Interface modules provide the subscriber connections for a 4000E BLC; up to four interface modules may be installed in the 4000E (in slots 1–4). There are a variety of models available for purchase. Refer to www.paradyne.com for further information or contact your sales re ...
Although the 4000E is factory shipped with Slot 1 open, interface modules may be installed in any slot, 1–4. 2. Align the interface module with the slot module guides. With the interface module PCB facing up and the interface module model name on the right side of the module faceplate (facing towards you), align the left and right edges of the PCB with the slot module guides of the ...
CAUTION: Turn your DC power source(s) OFF until you have completed connection of the 4000E as outlined in the following sections. Do not operate the 4000E without a ground connection. Procedure 1. Connect a ground wire to the 4000E: Line up the 2-hole terminal lug of your ground wire with the two holes on the small, unpainted section on the back of your chassis. Secure the terminal lug to the chassis w ...
from the chosen terminal block (labeled "+" on the chassis). Slide the ring terminal of your positive power lead around the shaft of the screw and insert the screw into the same "+" terminal from which it was removed. DC Terminal Blocks Ring Terminal POSITIVE POWER LEAD DC POWER TERMINAL Positive (+) Terminal ...
the ring terminal of your NEGATIVE lead around the shaft of the screw and insert the screw into the same "–" terminal from which it was removed. 6. Connect both power leads to a fuse panel. The negative (–) lead connects to a "Batt" (Battery) terminal and the positive (+) lead connects to a "Return" terminal on your DC power supply. CAUTION: ...
Interface Modules (MIMs) installed on the management module in your 4000E to operate at default settings. However, if you wish to run your uplink connections at settings other than the UIM or MIM defaults, configure the UIM or MIM prior to making a connection. For further connection and configuration information, refer to the installat ...
connectors provide the subscriber connections for ports 13-24. 2. Detach the hook-and-loop fastener Strap from the female RJ21 connector port: lift the hook-and-loop fastener tab from the bottom and pull the strap upward to open, leaving it looped under the right side of the connector frame. 3. Slide the male RJ21 connector of your interface cable under ...
against the connector, then pull the strap back down, such that the hook-and-loop fastener layers stick to one another across the top of the connector. 5. Tuck the tab at the end of the strap down between the connector frames so that it is out of the way of other connections. 6. Screw the right side of the RJ21 cable connector into the jack screw on th ...
Position all connecting cables such that they will not become a tripping hazard or pull loose from the chassis; secure with cable ties or hook-and-loop fastener straps. Configuration and Management Although no configuration is necessary to run subscriber lines at the default settings, all 4000E parameter settings are software selectable via Command Line Interface (CLI), Simple Network Management P ...
slots. It comes pre-installed and should not be removed unless it is being replaced. Fan functionality is indicated by a FAN LED on your management module (all models): No illumination or solid GREEN illumination indicates all fans are currently functioning, solid AMBER illumination indicates at least one of the four fans is no longer f ...
Complete documentation for Paradyne products is available at www.paradyne.com. Select Support → Technical Manuals. To order a paper copy of a Paradyne document, or to speak with a sales representative, please call 1-727-530-2000. Table 1. Specifications Specification Criteria Environment Operating Temperature: –40° F to 149° F (–40° C to 65° C) Storage Temperature: –40° F ...
1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel. 3. WARNING: This unit supports a redundant 48 VDC power input connection. Disconnect both sources ...
designed for wet locations. — Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface. — Use caution when installing or modifying telephone lines. — Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric sho ...
! This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations. Cet appareil numérique de la classe A respecte toutes les exigences du règlement sur le matérial brouilleur du Canada. Warranty, Sales, Service, and Training Information Contact your local sales representative, service representative, or distributor directly for any help needed. For addit ...