HP StorageWorks P2000 G3 iSCSI MSA

System Controller Firmware Release Notes Part Number: 635662-001 First edition: November 2010 ...

Not applicable — Factory only release

Supersedes Not applicable — Factory only release Product models HP StorageWorks P2000 G3 iSCSI MSA System controller firmware, TS220R004: • HP StorageWorks P2000 G3 iSCSI MSA Array System Controller (P2000 G3 iSCSI MSA Controller) HP StorageWorks P2000 Drive Enclosure firmwa ...

MSA70 disk enclosures are supported for use with P2000 G3 arrays, but must have firmware

2.18 installed. Please check the MSA70 or P2000 G3 QuickSpecs to confirm which version MSA70 firmware is supported. Known issues and workarounds Issue: In Japanese locale, the user cannot log in to the Storage Management Utility (SMU) if a HP StorageWorks D2700 Disk ...

Issue: Under rare circumstances, some events from one controller are not seen on the other controller.

Workaround: Review the events from both controllers. Issue: The following commands in the Command Line Interface (CLI) do not always return the complete output: • show vdisk-statistics • show controller-statistics • show disk-statistics • show host- ...

Issue: Using a long IQN name for iSCSI initiators may lead to issues while using SCSI-3 reservations and

Persistent Group Reservations, particularly when trying to create large clusters with multiple paths to each LUN. A predefined area is used to store SCSI-3 reservation keys for each initiator path to each LUN and, when a large number of IQN entries are at ...

Issue: When using explicit LUN mapping, using long IQN names for the iSCSI Initiator can cause the array

to map the LUN incorrectly. A predefined area is used to store explicit LUN mapping information per LUN and, with longer IQN names, this area can be exhausted. This issue is not dependent on the number of paths to the LUN. Workaround: Shorten the IQN name ...

Issue: USB CLI becomes unusable after a Management Controller reboot in Windows environments.

Workaround: 1. Close down the terminal application. (Example: HyperTerminal) 2. Open Device Manager and disable the “Disk Array USB Port” under Ports (COM & LPT). 3. Re-enable the “Disk Array USB Port”. If the problem persists, reboot the host. Issue: The mi ...

Issue: Debug logs are incomplete.

Workaround: Determine if the logs are incomplete by unzipping the log file retrieved from the array and examining the last line of the store_YYYY_MM_DD__HH_MM_SS.logs file for the lines: End of Data ]]>. If the file contains these two lines at the end of the file, it is complete and you can forward i ...