XP24000/XP20000 SNMP Agent Reference

Guide Abstract This guide describes the implementation of SNMP for monitoring HP StorageWorks XP24000/XP20000 storage systems. The guide lists the monitored storage system components and supported traps, describes the trap protocol and extension MIB, and explains how to use the GUI to limit SNMP access to specific SNMP managers. The intended audience is a storage system administrator or authorized service provider with independent knowledge of HP StorageWorks XP storage systems and Remote Web Console. HP Part Number: AE131-96088 Published: May 2011 Edition: Thirteenth

© Copyright 2007, 2011 Hewlett-Packard Development Company, L.P.

Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Acknowledgments Microsoft, Windows, and Windows XP are U.S. registered trademarks of Microsoft Corporation. Hitachi and Universal Replicator are registered trademarks of Hitachi, Ltd. ShadowImage and TrueCopy are registered trademarks of Hitachi, Ltd. and Hitachi Data Systems Corporation Export Requirements You may not export or re-export this document or any copy or adaptation in violation of export laws or regulations. Without limiting the foregoing, this document may not be exported, re-exported, transferred or downloaded to or within (or to a national resident of) countries under U.S. economic embargo, including Cuba, Iran, North Korea, Sudan, and Syria. This list is subject to change. This document may not be exported, re-exported, transferred, or downloaded to persons or entities listed on the U.S. Department of Commerce Denied Persons List, Entity List of proliferation concern or on any U.S. Treasury Department Designated Nationals exclusion list, or to parties directly or indirectly involved in the development or production of nuclear, chemical, biological weapons, or in missile technology programs as specified in the U.S. Export Administration Regulations (15 CFR 744). Revision History Description Date Edition This edition applies to microcode version 60-01-31-00/00 or later. June 2007 First This edition applies to microcode version 60-02-04-00/00 or later. September 2007 Second This edition applies to microcode version 60-02-25-00/00 or later. January 2008 Third This edition applies to microcode version 60-02-48-00/00 or later. April 2008 Fourth This edition applies to microcode version 60-03-04-00/00 or later. June 2008 Fifth This edition applies to microcode version 60-03-24-00/00 or later. September 2008 Sixth This edition applies to microcode version 60-04-04-00/00 or later. December 2008 Seventh This edition applies to microcode version 60-04-13-00/00 or later. February 2009 Eighth This edition applies to microcode version 60-05-00-00/00 or later. June 2009 Ninth This edition applies to microcode version 60-06-05-00/00 or later. December 2009 Tenth This edition applies to microcode version 60-07-00-00/00 or later. June 2010 Eleventh This edition applies to microcode version 60-07-50-00/00 or later. October 2010 Twelfth This edition applies to microcode version 60-08-01-00/00 or later. May 2011 Thirteenth

1 Overview of SNMP.....................................................................................5

SNMP Manager Overview........................................................................................................5 SNMP Manager and SNMP Agent Interaction.........................................................................5 Management Information Base (MIB)......................................................................................6 SNMP Agent Overview.............................................................................................................6 System Configuration............................................................................................................6 SNMP Agent Functions.........................................................................................................7 SNMP Manager Functions.........................................................................................................8 Component Status Information...............................................................................................8 2 Using the SNMP GUI................................................................................10 SNMP Information Tab............................................................................................................10 3 Performing SNMP Operations....................................................................14 Adding SNMP Manager IP Addresses.......................................................................................14 Deleting SNMP Manager IP Addresses......................................................................................15 Adding a Community Name....................................................................................................16 Deleting a Community Name...................................................................................................17 Changing a Community Name.................................................................................................17 Adding Community IP Addresses..............................................................................................18 Deleting a Community IP Address.............................................................................................19 Testing the SNMP Trap Report..................................................................................................20 4 SNMP Supported MIB...............................................................................21 Trap Configuration..................................................................................................................21 Extension Trap Specifications...............................................................................................21 Extension Trap PDU............................................................................................................21 Standard MIB Specifications....................................................................................................22 Supported MIB..................................................................................................................22 MIB Access Mode..............................................................................................................22 Object Identifier System......................................................................................................22 Supported Traps................................................................................................................24 MIB Mounting Specifications...............................................................................................24 Extension MIB Specifications....................................................................................................25 Extension MIB Configuration...............................................................................................25 Extension MIB Configuration....................................................................................................32 5 SNMP Failure Trap Reference.....................................................................34 6 Troubleshooting........................................................................................41 Mitigating SNMP Errors...........................................................................................................41 Calling HP Technical Support...................................................................................................41 7 Support and Other Resources.....................................................................42 Related Documentation............................................................................................................42 Conventions for Storage Capacity Values...................................................................................42 HP Technical Support..............................................................................................................42 Contents 3

Subscription Service................................................................................................................43 HP Websites..........................................................................................................................43 Documentation Feedback.........................................................................................................43 Glossary....................................................................................................44 Index.........................................................................................................46 4 Contents

1 Overview of SNMP

This chapter provides an overview of SNMP including an overview of the agent and management functions: • “SNMP Manager Overview” (page 5) • “SNMP Agent Overview” (page 6) • “SNMP Manager Functions” (page 8) Unless otherwise specified, the term storage system in this guide refers to the following disk arrays: • HP StorageWorks XP24000 Disk Array • HP StorageWorks XP20000 Disk Array The GUI illustrations in this guide were created using a Windows computer with the Internet Explorer browser. Actual windows may differ depending on the operating system and browser used. GUI contents also vary with licensed program products, storage system models, and firmware versions. SNMP Manager Overview SNMP Manager and SNMP Agent Interaction The following figure shows an SNMP environment. Figure 1 SNMP Environment SNMP is an industry-standard protocol for managing and monitoring network devices, including disk devices, routers, and hubs. SNMP uses SGMP to manage the TCP/IP gateways. The standardized configuration and database of network management information is called a MIB. A standard MIB is common to all SNMP interfaces. An extension MIB is defined by the particular managed device or protocol. An SNMP manager monitors the devices, which are referred to as managed nodes. The primary types of interaction between the SNMP manager and an SNMP agent are polling and trap. Typically, the SNMP manager polls the SNMP agents on a periodic basis, to determine whether the device is operating normally. If an abnormal event occurs, the SNMP Agent can report the condition without a request from the manager, by using a message called trap. When an SNMP Manager polls the agent, the following dialog takes place: • An SNMP manager sends a request packet to an SNMP agent, which requests data regarding the status of managed node. • The SNMP agent sends a response packet back to the SNMP manager. SNMP Manager Overview 5

SNMP uses the TCP/IP UDP. If the SNMP agent does not respond within a specified time

period, the SNMP manager re-sends the request packet. That time period is set by the system administrator, taking into account the network traffic and operation policy. • If an SNMP agent again does not respond to the re-sent packet, the SNMP manager assumes that an error has occurred. Depending on the times set for polling and response, this can take several seconds. If an SNMP agent detects an abnormal event, it sends a trap to the SNMP manager. However, if a trap is dropped in transmission, the SNMP manager does not know that it was sent. For this reason, you should use both polling and traps to determine whether an abnormal event has occurred. Management Information Base (MIB) Each managed device has certain types of information, including the configuration information, the status information for device, and statistical, which is known collectively as a Management Information Base (MIB). Each parameter is called a managed object, and it consists of the parameter name, one or more parameter(s), and a group of operations that can be executed with the object. The MIB defines the type of information that can be obtained from a managed device, and the device settings that can be controlled from a management system. SNMP Agent Overview System Configuration The SNMP agent for the HP storage system is on the SVP, which is the computer within the storage array that manages the storage system. The storage system has an exclusive LAN for communications between a disk controller and a service processor, and a separate LAN for SNMP. The configuration of each Network Management Station is determined by the type of SNMP Manager. The following figure illustrates the SNMP environment. Figure 2 SNMP Environment Architecture The following figure shows an example of SNMP operations by using an SNMP manager. 6 Overview of SNMP

Figure 3 Example of SNMP Operations

SNMP Agent Functions SNMP Traps An SNMP agent reports a storage system error to a SNMP manager using the trap report function. If an error occurs, an SNMP agent issues an SNMP trap to an SNMP manager to report a failure. Issuing an SNMP trap, an SNMP agent also reports a product number, nickname, reference code, and an identifier of the component. The following table lists the events that trigger an SNMP agent trap. Table 1 SNMP Trap Triggering Events Description Events All operations in a storage system stopped. Acute failure detected. Operation in a component where a failure occurred stopped. Serious failure detected. Partial failure. Moderate failure detected. Minor failure. Service failure detected. An SNMP agent logs the most recent 256 traps, so you can see the trap history of a particular device. SNMP Agent Operations The following table lists the types SNMP Agent operations. Table 2 SNMP Agent Operations Description Operation Obtains a specific MIB object value. GET REQUEST is the request from an SNMP manager, and GET RESPONSE is the agent's response to that request. GET Continuously finds a MIB object. GETNEXT REQUEST is the request from an SNMP manager, and GETNEXT RESPONSE is the agent's response to that request. GETNEXT Reports an event (failure) to an SNMP manager. TRAP occurs without a request from the SNMP manager. TRAP SNMP Agent Overview 7

The following table lists the errors to be reported for the REQUEST operations.

Table 3 SNMP Agent REQUEST Operations Corrective Action Description Error N/A Normal noError(0) Verify that the requested object is correct. • There are no MIB objects that are required. (Not supported). • The GETNEXT REQUEST command that is specified for the following object identifier of the last supported MIB object is received. noSuchName(2) SET operation is not supported. SET REQUEST is received. readOnly(4) Retry the operation. Error occurred for other reasons. genErr(5) SNMP Manager Functions Component Status Information You can obtain the status information for certain storage system components from an SNMP manager. The following table lists the components for which the status can be obtained. Table 4 Available Component Status Information Component Name Area Processor Storage System BUS Cache Shared memory Power supply Battery Fan Others Hard Disk Drive Power supply Disk Unit Fan Others Drive The following table lists the storage system component status as well as the trap report function. Table 5 Storage system Component Status Types Description Status Normal operation. Normal All operations in a storage system stopped. Acute failure detected Operation in a component where a failure occurred stopped. Serious failure detected 8 Overview of SNMP

Table 5 Storage system Component Status Types (continued)

Description Status Partial failure. Moderate failure detected Minor failure. Service failure detected SNMP Manager Functions 9

2 Using the SNMP GUI

This chapter explains the SNMP information tab: • “SNMP Information Tab” (page 10) SNMP Information Tab The SNMP IP Security tab allows you to limit SNMP access to specific SNMP managers and to enter SNMP trap addresses. Click Go – Install – SNMP SNMP IP Security in the menu bar of Remote Web Console Main window. The SNMP IP Security tab displays. Select the SNMP SNMP IP Security tab (see “SNMP Information Tab” (page 11)). Option buttons (left side of the window) and storage system information icons (window upper right corner) have been omitted from the screen shot. See HP StorageWorks XP24000/XP20000 Remote Web Console User Guide for an illustration. 10 Using the SNMP GUI

Figure 4 SNMP Information Tab

Table 6 SNMP Information Tab Description Item The Extension SNMP check box is selected if the SNMP Agent feature is enabled. To set the SNMP Agent properties from XP Remote Web Console computer, select Extension SNMP on SNMP Information window. Install The Manager section allows you to add and delete SNMP manager information (see “Adding SNMP Manager IP Addresses” (page 14)). Manager Displays the IP addresses of registered SNMP managers from which the SNMP agent accepts requests. If no manager is registered, the SNMP agent accepts requests from all managers. You can register up to 32 managers. IP Address list box SNMP Information Tab 11

Table 6 SNMP Information Tab (continued)

Description Item Enter the IP address of the manager that the SNMP Agent receives the request from. • Ipv4 and Ipv6 addresses can be specified for IP Address. However, if the OS of SVP is Windows XP and you enter Ipv6 address and select Apply, an error message is displayed and the Ipv6 address is not set. • Any IP address having all values set to zero (0) cannot be specified for Ipv4 and Ipv6. • The Ipv4 address is specified by entering four (4) numbers that are separated by periods (.) using a maximum 3 digits from zero (0) to 255 inclusive (for example, XXX.XXX.XXX.XXX where X is a number). Enter the numbers only and do not enter periods. • The Ipv6 address is specified by entering eight (8) hexadecimal numbers that are separated colons (:) using a maximum 4 digits from zero (0) to FFFF inclusive (for example, YYYY:YYYY:YYYY:YYYY:YYYY:YYYY:YYYY:YYYY where Y is a hexadecimal number). Enter the hexadecimal numbers only and do not enter the colons. The cursor can be moved between the entry field using the Tab key. IP Address text box Is selected when entering an Ipv4 address. The Ipv4 address can be entered to IP address text box when this radio box is selected. Ipv4 radio box Is selected when entering Ipv6 address. The Ipv6 address can be entered to IP address text box when this radio box is selected. Ipv6 radio box Adds new IP addresses to the IP Address list box. Set Allows you to add, delete, or change SNMP trap information. The registered IP address is the trap destination for the specified community. • Each community can have more than one defined IP address (see “Adding a Community Name” (page 16) and “Adding Community IP Addresses” (page 18)). • You can register up to 32 community names and up to 32 IP addresses per community name. • You can use up to 180 alphanumeric characters for a community name. You cannot use the following: ", \, ;, :, ,, *, ?, <, >, |, /, ^, &, %, and a space before or after the community name. Community & Trap 12 Using the SNMP GUI

Table 6 SNMP Information Tab (continued)

Description Item Allows you to add, delete or change SNMP system group information. If system group information has already been registered, the registered information displays. To register the system group information, the Extension SNMP check box must be selected. When you register system group information, select Apply. System group information is as follows: • Name: Connected storage system name. Remote Web Console users can change the device name. You can use up to 180 alphanumeric characters for a device name. You cannot use the following: ", \, ;, :, ,, *, ?, <, >, |, /, ^, &, %, . You can use a space in the middle of the device name, but not before and after and a space before or after the device name. The device name is required to use SNMP Agent. Make sure to document the device name, because settings will be cleared when SVP is replaced. • Contact: Contact information such as personnel and telephone numbers where you can inquire about the connected storage system. Remote Web Console users can change contact information in Modify mode. Enter contact information using up to 180 alphanumeric characters (ASCII codes), except for some symbols, such as ", \, ;, :, ,, *, ?, <, >, |, /, ^, &, and %. You can also use a space, except before and after contact information. A contact name is required to use SNMP Agent. Make sure to document the contact name, because settings will be cleared when SVP is replaced. • Location: Location of connected storage system. Remote Web Console users can change device locations with the modify mode. You must enter a device location using up to 180 alphanumeric characters (ASCII codes). You can use a space, except for before and after the location. You cannot use some symbols, such as ", \, ;, :, ,, *, ?, <, >, |, /, ^, &, and %. The device location is required to use SNMP Agent. Make sure to document the device location, because the settings will be cleared when SVP is replaced. System Group Executes test report of the trap to the community registered in the disk storage system. Operation in Modify mode is required to use this button. Operation authority is required as well. Trap Test Implements settings made on this window. Apply Cancels settings made on this window. Cancel SNMP Information Tab 13

3 Performing SNMP Operations

This chapter covers adding and deleting an SNMP manager IP address, adding and deleting a community name, along with adding and deleting a community IP address: • “Adding SNMP Manager IP Addresses” (page 14) • “Deleting SNMP Manager IP Addresses” (page 15) • “Adding a Community Name” (page 16) • “Deleting a Community Name” (page 17) • “Changing a Community Name” (page 17) • “Adding Community IP Addresses” (page 18) • “Deleting a Community IP Address” (page 19) • “Testing the SNMP Trap Report” (page 20) Adding SNMP Manager IP Addresses To add SNMP Manager IP addresses: 1. Log on to open Remote Web Console Main window. Change to Modify mode (see the HP StorageWorks XP24000/XP20000 Remote Web Console User Guide if you need instructions). 2. Click Go – Environmental Settings – SNMP Information in the menu bar of Remote Web Console Main window. The SNMP Information window is displayed (see “SNMP Information Tab” (page 11)). 3. Select the radio box of Ipv4 or Ipv6 and specify the version of the IP address you enter. NOTE: If the OS of SVP is Windows XP and you enter Ipv6 address and select Apply, an error message is displayed and the Ipv6 address is not set. 4. Enter desired numerical IP address in IP Address text box (see “Adding SNMP Manager IP Address (Top: Before Setting, Bottom: After Setting)” (page 15)). 5. Select Set. The new IP address is added to IP Address list, but the changes are not implemented. 14 Performing SNMP Operations

Select Apply to implement the changes, or select Cancel to cancel the changes, then select

OK on the confirmation message. Figure 5 Adding SNMP Manager IP Address (Top: Before Setting, Bottom: After Setting) Deleting SNMP Manager IP Addresses To delete an SNMP Manager IP address: 1. Change to Modify mode. 2. Log on to Remote Web Console. Click Go – Environmental Settings – SNMP Information in the menu bar of Remote Web Console Main window. The SNMP Information window is displayed (see “SNMP Information Tab” (page 11)). 3. Select one or more unwanted IP addresses in IP Address list box. Right-click to display Delete IP Address menu (see “Delete IP Address Menu” (page 16)). 4. Select Delete IP Address. 5. A confirmation message displays. Select OK or Cancel. 6. Select Apply. Select OK or Cancel. Deleting SNMP Manager IP Addresses 15

Figure 6 Delete IP Address Menu

Adding a Community Name To add a community name: 1. Change to Modify mode. 2. Log on to Remote Web Console. Click Go – Environmental Settings – SNMP Information in the menu bar of Remote Web Console Main window. The SNMP Information window is displayed (see “SNMP Information Tab” (page 11)). 3. In Community & Trap box, select and right-click Community. Add Community menu displays (see “Add Community Menu” (page 16)). 4. Select Add Community. Community dialog box (see “Add Community dialog box” (page 17)) displays. 5. In the Community text box, enter desired community name. You can use up to 180 alphanumeric characters, except for ", \, ;, :, ,, *, ?, <, >, |, /, ^, &, and %. You can also use spaces, except at the beginning or the end of the name. 6. Select OK. The new community name displays in Community & Trap, but the changes are not yet implemented in the storage system. 7. To add one or more IP addresses to the new community, see “Adding Community IP Addresses” (page 18). 8. To apply changes, select Apply. Select OK or Cancel. Figure 7 Add Community Menu 16 Performing SNMP Operations

Figure 8 Add Community dialog box

Deleting a Community Name To delete a community name: 1. Change to Modify mode. 2. Log on to open Remote Web Console Main window, click Go – Environmental Settings – SNMP Information in the menu bar of Remote Web Console Main window. The SNMP Information window is displayed (see “SNMP Information Tab” (page 11)). 3. In Community & Trap, select and then right-click the unwanted community. The Delete Community menu displays (see “Delete Community Menu” (page 17)). 4. Select the Delete Community command. A confirmation message displays. 5. Select OK or Cancel. The selected community is deleted from Community & Trap, but the setting is not yet implemented in the storage system. 6. Select Apply. Select OK or Cancel on the confirmation message. Figure 9 Delete Community Menu Changing a Community Name To change a community name: 1. Change to Modify mode (see the HP StorageWorks XP24000/XP20000 Remote Web Console User Guide if you need instructions). 2. Log on to Remote Web Console. Click Go – Environmental Settings – SNMP Information in the menu bar of Remote Web Console Main window. The SNMP Information window is displayed (see “SNMP Information Tab” (page 11)). 3. Select and then right-click the community name that you want to change in Community & Trap. The Change Community menu displays (see “Change Community Menu” (page 18)). Deleting a Community Name 17

Select Change Community. The Change Community dialog box displays (see “Change

Community dialog box” (page 18)). 5. In the Community text box, overwrite the old community name with a new community name. You can use up to 180 alphanumeric characters, except for ", \, ;, :, ,, *, ?, <, >, |, /, ^, &, and %. You can also use spaces, except at the beginning or the end of the name. 6. Select OK. The changed community name displays in Community & Trap, but the changes are not yet implemented in the storage system. 7. Select Apply. Select OK or Cancel. Figure 10 Change Community Menu Figure 11 Change Community dialog box Adding Community IP Addresses To add a community IP address: 1. Log on to Remote Web Console. Click Go – Environmental Settings – SNMP Information in the menu bar of Remote Web Console Main window. The SNMP Information window is displayed (see “SNMP Information Tab” (page 11)). 2. Select and right-click the desired community to display the Add Community menu (see “Add IP Address Menu” (page 19)). 3. Select Add IP Address. The Add IP Address dialog box displays (see “IP Address dialog box” (page 19)). 4. In IP Address, enter a new IP address or select an existing IP address. 18 Performing SNMP Operations

If the values for an IP address are all set to zero (0), that address cannot be specified for

Ipv4 and Ipv6. • The Add IP Address dialog box does not support shortened expression for Ipv6 address. Enter 8 hexadecimal numbers that are separated colons (:) to a maximum 4 digits from zero (0) to FFFF inclusive. • When the OS of the SVP is Windows XP, if you enter an Ipv6 address and select Apply, an error message is displayed and the Ipv6 address cannot be set. 5. Select OK. The new IP address displays in Community & Trap, but the change is not yet implemented. 6. Select Apply. Select OK or Cancel. Figure 12 Add IP Address Menu Figure 13 IP Address dialog box Deleting a Community IP Address To delete a community IP address: 1. Change to Modify mode. 2. Log on to Remote Web Console. Click Go – Environmental Settings – SNMP Information in the menu bar of Remote Web Console Main window. The SNMP Information window is displayed (see “SNMP Information Tab” (page 11)). 3. Select SNMP Information. 4. In Community & Trap, select the unwanted community IP address. Right-click to display Delete IP Address menu (see “Delete Community IP Address Menu” (page 20)). Deleting a Community IP Address 19

Select Delete IP Address. A confirmation message displays.

6. Select OK or Cancel. The selected IP address is deleted from Community & Trap, but the change is not yet implemented. 7. Select Apply or Cancel. Select OK on the confirmation message. Figure 14 Delete Community IP Address Menu Testing the SNMP Trap Report To test the SNMP Trap report: 1. Log on to Remote Web Console. Click Go – Environmental Settings – SNMP Information in the menu bar of Remote Web Console Main window. The SNMP Information window appears. 2. Change to Modify mode. 3. Select Trap Test. A confirmation message displays. 4. Select OK or Cancel. Verify whether the SNMP trap report, which is reference code 7FFFFF, is received by the SNMP manager registered in the community. 20 Performing SNMP Operations

4 SNMP Supported MIB

This chapter explains MIB specifications, standard and extension, the SNMP GUI, and trap configuration: • “Trap Configuration” (page 21) • “Standard MIB Specifications” (page 22) • “Extension MIB Specifications” (page 25) • “Extension MIB Configuration” (page 25) Trap Configuration Extension Trap Specifications The specifications of the supported extension trap are as follows. Table 7 Extension Trap Specifications Mounting Value Specification Operation — Specified community name SNMP Community 4 Trap PDU Protocol Data Unit (PDU) Type 1.3.6.1.4.1.116.3.11.4.1.1 Agent Identifier Enterprise ID — Agent IP Address Agent IP Address — EnterpriseSpecific Generic Trap Code — See “Specific Trap Codes” (page 21). Specific Trap Code Table 8 Specific Trap Codes Description Name Specific Trap Code Failure report: All operations in a storage system stopped. RaidEventUserAcute 1 Failure report: Operation in a component where a failure occurred stopped. RaidEventUserSerious 2 Failure report: Partial failure. RaidEventUserModerate 3 Failure report: Minor failure. RaidEventUserService 4 Extension Trap PDU Failure Report Trap An extension trap PDU includes the product number of the device that experienced the failure, the device nickname, and a failure reference code. If you obtain the information with GetRequest command, access the MIB by using the product number of the device as an index. Table 9 (page 22) shows the failure report trap. Trap Configuration 21

Table 9 Failure Report Trap

Description Type Object Identifier Name The product number of the device that experienced the failure. INTEGER 1.3.6.1.4.1.116.5.11.4.2.1 EventTrapSerialNumber The device nickname. DisplayString 1.3.6.1.4.1.116.5.11.4.2.2 EventTrapNickname The failure reference DisplayString 1.3.6.1.4.1.116.5.11.4.2.3 EventTrapREFCODE The area where the failure occurred (Note). OBJECT IDENTIFIER 1.3.6.1.4.1.116.5.11.4.2.4 EventTrapPartsID Failure occurrence date. DisplayString 1.3.6.1.4.1.116.5.11.4.2.5 EventTrapDate Failure occurrence time. DisplayString 1.3.6.1.4.1.116.5.11.4.2.6 EventTrapTime Detailed information about a failure. DisplayString 1.3.6.1.4.1.116.5.11.4.2.7 EventTrapDescription NOTE: For example, the object identifier for a failure in a storage system processor would be 1.3.6.1.4.1.116.5.11.4.1.1.6.1.2. Standard MIB Specifications Supported MIB The following table shows the supported MIBs. If you send a GET request for an object (MIB) that is not supported, you will receive NoSuchName as a GET RESPONSE. Table 10 Supported MIBs Supported? MIB Supported system group Standard MIB: MIB-II Not supported interface group Not supported at group Not supported ip group Not supported icmp group Not supported tcp group Not supported udp group Not supported egp group Not supported snmp group Supported Extension MIB MIB Access Mode The access mode for MIB in all communities is read only. If you send a GET request for a SET operation, you will receive NoSuchName as a GET RESPONSE. Object Identifier System An object system supported by SNMP agent is as follows: 22 SNMP Supported MIB

Figure 15 Object System (1)

Figure 16 Object System (2) Figure 17 Object System (3) Standard MIB Specifications 23

The following table shows the supported trap types.

Table 11 Extension Trap Types Description Trap Specific Trap Code All operations in a storage system stopped. RaidEventUserAcute 1 Operation in a component where a failure occurred stopped. RaidEventUserSerious 2 Partial failure. RaidEventUserModerate 3 Minor failure. RaidEventUserService 4 MIB Mounting Specifications The supported MIB mounting specifications are as follows: • mgmt: OBJECT IDENTIFIER ::= {iso(1) org(3) dod(6) internet(1) 2 } • mib-2: OBJECT IDENTIFIER ::= {mgmt 1} An SNMP agent mounts only system groups in mib-2, as shown in the following table. Table 12 System Groups Mounted Value Description Name Fixed value RAID 600 Name of hardware or OS. sysDescr {system 1} Fixed value. See “Object Identifier System” (page 22). 1.2.6.1.4.1.116.3.11.4.1.1 Object ID indicating the product identification number. sysObjectID {system 2} Unit: ms An accumulated time from an SNMP agent. sysUpTime {system 3} Maximum 180 characters in an ASCII characters string (see Note) Input by a user from an SNMP setting window. A manager who manages an agent or a contact address. sysContact {system 4} Maximum 180 characters in an ASCII characters string (see Note) Input by a user from an SNMP setting window. A given name for managing an agent. sysName {system 5} Maximum 180 characters in an ASCII characters string (see Note) Input by a user from an SNMP setting window. An agent setup location. sysLocation {system 6} Fixed value 76 (decimal) Value indicating a service. sysService {system 7} 24 SNMP Supported MIB

The following symbols cannot be used: \ , / : ; * ? " < > | & % ^

Extension MIB Specifications Extension MIB Configuration “Extension MIB Configuration” (page 25) shows the Extension MIB configuration. Figure 18 Extension MIB Configuration raidExMibName raidExMibName indicates the SVP product name. raidExMibVersion raidExMibVersion indicates the microcode version. Extension MIB Specifications 25

raidExMibAgentVersion indicates the internal version of the extension MIB.

Number of Storage Systems under Control of SVP (raidExMibDkcCount) raidExMibDkcCount suggests the number of a storage system under the control of SVP. raidExMibRaidList raidExMibRaidList indicates the storage system under the control of the SVP. (raidlistEntry) raidlistEntry indicates the list of arrays managed by this SVP 26 SNMP Supported MIB

The following table shows the type of information displayed for each storage system

Table 13 Storage system Information Attribute Mounted Value Description Type Name read-only 1-99,999 Storage system product number (index). INTEGER raidlistSerialNumber ::=raidlistEntry(1) read-only (Max. 18 characters) Storage system nickname. DisplayString raidlistMibNickName ::=raidlistEntry(2) read-only (Max. 10 characters) Microcode version. DisplayString raidlistDKCMainVersion ::=raidlistEntry(3) read-only *1 (7 characters) Storage system product type. DisplayString raidlistDKCProductName ::=raidlistEntry(4) *1 RAID600 will be indicated as Storage system product type (raidlistDKCProductName). raidExMibDKCHW raidExMibDKCHW indicates the status of the storage system components. dkcHWEntry dkcHWEntry indicates the status of the storage system components. Extension MIB Specifications 27

The following table describes the status of the storage system components

Table 14 Storage system component information Attribute MIB Value Description Type Name read-only 1-99,999 Storage system product number (index). INTEGER DKCRaidListIndexSerialNumber ::=dkcHWEntry(1) read-only Note (1 digit) Status of processor. INTEGER DKCHWProcessor ::=dkcHWEntry(2) read-only Note (1 digit) Status of internal star. INTEGER DKCHWCSW ::=dkcHWEntry(3) read-only Note (1 digit) Status of cache. INTEGER DKCHWCache ::=dkcHWEntry(4) read-only Note (1 digit) Status of shared memory. INTEGER DKCHWSM ::=dkcHWEntry(5) read-only Note (1 digit) Status of power supply. INTEGER DKCHWPS ::=dkcHWEntry(6) read-only Note (1 digit) Status of battery. INTEGER DKCHWBattery ::=dkcHWEntry(7) read-only Note (1 digit) Status of fan. INTEGER DKCHWFan ::=dkcHWEntry(8) read-only Note (1 digit) Others. INTEGER DKCHWEnvironment ::=dkcHWEntry(9) NOTE: The status of each component is indicated as follows: 1: Normal. 2: Acute failure detected. 3: Serious failure detected. 4: Moderate failure detected. 5: Service failure detected. raidExMibDKUHW raidExMibDKUHW indicates the status of the storage system components. 28 SNMP Supported MIB

dkuHWEntry indicates the status of the disk unit components.

Table 15 Storage System component information Attribute MIB Value Description Type Name read-only 1-99,999 Storage system product number (index). INTEGER DKURaidListIndexSerialNumber ::=dkuHWEntry(1) read-only Note (1 digit) Status of power supply. INTEGER DKUHWPS ::=dkuHWEntry(2) read-only Note (1 digit) Status of fan. INTEGER DKUHWFan ::=dkuHWEntry(3) read-only Note (1 digit) Status of environment monitor. INTEGER DKUHWEnvironment ::=dkuHWEntry(4) read-only Note (1 digit) Status of drive. INTEGER DKUHWDrive ::=dkuHWEntry(5) Extension MIB Specifications 29

The status of each component is indicated as follows:

1: Normal. 2: Acute failure detected. 3: Serious failure detected. 4: Moderate failure detected. 5: Service failure detected. raidExMibDKCHW2 raidExMibDKCHW2 indicates the status of the storage system components. Table 16 Storage system components information 2 Attribute MIB Value Description Type Name read-only 1-99,999 Storage system product number (index). INTEGER DKC2RaidListIndexSerialNumber ::=dkcHW2Entry(1) read-only Note (1 digit) Information about environmental failure. INTEGER DKCHW2Environment ::=dkcHW2Entry(2) read-only Note (1 digit) Status of SVP. INTEGER DKCHW2SVP ::=dkcHW2Entry(3) read-only Note (1 digit) Status of program product failure. INTEGER DKCHW2PP ::=dkcHW2Entry(4) 30 SNMP Supported MIB

The status of each component is indicated as follows:

1: Normal. 2: Acute failure detected. 3: Serious failure detected. 4: Moderate failure detected. 5: Service failure detected. raidExMibTrapList raidExMibTrapList suggests the history of the failure traps. Table 17 Failure Information Attribute MIB Value Description Type Name read-only 1-99,999 Storage system product number (index). INTEGER EventListIndexSerialNumber ::=eventTrapEntry(1) read-only (Max. 18 characters) Storage system nickname. DisplayString EventListNickname ::=eventTrapEntry(2) read-only 1-256 Number of record. Counter EventListIndexRecordNo ::=eventTrapEntry(3) read-only (6 characters) Reference code. DisplayString EventListREFCODE ::=eventTrapEntry(4) read-only yyyy/mm/dd (10 characters) Date when the failure occurred. DisplayString EventListData ::=eventTrapEntry(5) Extension MIB Specifications 31

Table 17 Failure Information (continued)

Attribute MIB Value Description Type Name read-only hh:mm:ss (18 characters) Time when the failure occurred. DisplayString EventListTime ::=eventTrapEntry(6) read-only (maximum 256 characters) Detailed information about the failure. DisplayString EventListDescription ::=eventTrapEntry(7) Extension MIB Configuration Figure 19 Extension MIB Configuration (1) 32 SNMP Supported MIB

5 SNMP Failure Trap Reference

This chapter shows the alert level, the trap reference code, the description, and the alert level: • “SNMP Failure Trap Reference Codes” (page 34) • “SIM List for TrueCopy for Mainframe Errors” (page 40) The following table shows the alert level, the trap reference code, the description, and the alert level. Table 18 SNMP Failure Trap Reference Codes Alert Level Description Trap Reference Code SIM13 SIM23 SIM22 MODERATE Processor LCM hard error yz 3x 21 MODERATE ADP blockade xy 72 21 MODERATE RIO path blockade xy 80 21 MODERATE Remote copy logical path blockade (notification of failure from extender) xy 82 21 SERIOUS Link data transfer error xy 93 21 SERIOUS Link data transfer error xy 94 21 MODERATE HTP hardware error xy A0 21 MODERATE HTP path blockade xy A2 21 MODERATE HTP blockade xy A3 21 MODERATE External port blockade x: The CHA package number y: The number of the port in the package xy D0 21 SERVICE External device response timeout x: The CHA package number y: The number of the port in the package xy D2 21 MODERATE Processor blockade xy 73 30 MODERATE FM failure xy 75 30 Acute CHA PCB blockade xx=00:Fibre, xx=01:MFibre, xx=02:Serial xx=FF:All CHA xx A0 30 Acute DKC blockade 00 A1 30 MODERATE Processor blockade xy 73 31 MODERATE FM failure xy 75 31 Acute DKA PCB blockade 00 A0 31 MODERATE DRR blockade xy 82 CF MODERATE FCA blockade xy 83 CF 34 SNMP Failure Trap Reference

Table 18 SNMP Failure Trap Reference Codes (continued)

Alert Level Description Trap Reference Code SIM13 SIM23 SIM22 SERVICE Cache Cache Module Blockade processing finished xy C2 FF SERVICE Cache Package Blockade processing finished 0x C3 FF SERVICE Cache temporary failure xy F1 FF MODERATE Module blockade xy F2 FF MODERATE Package blockade 0x F3 FF SERIOUS Module group blocking 0x F4 FF SERIOUS Area blocking 0x E2 FF SERIOUS HP StorageWorks XP for Compatible Parallel Access Volumes Software microcode volatilization 01 E9 FF SERVICE Recovery of area blocked temporarily was completed 0x EA FF SERVICE Temporary blockade 0x EE FF MODERATE Drive Drive port blockade (Path 0 side) xx 8y DF MODERATE Drive port blockade (Path 1 side) xx 9y DF SERIOUS LDEV blockade (Fibre blockade) (Path 0 side) xx Ay DF SERIOUS LDEV blockade (Fibre blockade) (Path 1 side) xx By DF SERIOUS Drive failure Drive blockade (Drive system) xxx: The drive number xx 0x EF SERIOUS Drive Drive blockade (Drive system) xx 1y EF SERVICE Drive blockade (Drive system) xx 2y EF MODERATE External volume write error yy 5x EF SERIOUS LDEV blockade (Drive system) xx 9y EF SERIOUS Device connecting to external storage system is blocked. 00 D0 EF MODERATE External volume read error yy 5x FF SERIOUS Drive failure Drive blockade (Media system) xxx: The drive number xx Bx 43 SERIOUS Drive Drive blockade (Media system) xx Cy 43 SERVICE Correction copy start xx 1y 45 SERVICE Correction copy normal end xx 2y 45 SERIOUS Correction copy abnormal end xx 3y 45 SERVICE Correction copy warning end xx 5y 45 SERVICE Dynamic sparing start xx 1y 46 35

Table 18 SNMP Failure Trap Reference Codes (continued)

Alert Level Description Trap Reference Code SIM13 SIM23 SIM22 SERVICE Dynamic sparing normal end xx 2y 46 MODERATE Dynamic sparing abnormal end xx 3y 46 SERVICE Dynamic sparing warning end xx 5y 46 SERVICE Sidefile 40% over xx 0x 49 MODERATE Power supply (DKU) HDU power supply shutdown detected xy 50 AC MODERATE Environmental failure Fuse failure A5 0x BF MODERATE Fuse failure A6 0x BF MODERATE Abnormal temperature 1x 1x BF MODERATE Power supply (DKC) Alarm for voltage 1x 2x BF MODERATE Warning for power supply 1x 4x BF MODERATE Power supply Warning of power supply box A5 41 BF MODERATE Warning of power supply box A6 41 BF MODERATE Battery Warning for battery 1x 5x BF MODERATE Warning for battery Bx 5x BF MODERATE Battery Warning for battery xx 58 BF MODERATE DKC environment Warning for alternating current D0 60 BF MODERATE (3 phase AC Box) D1 60 BF MODERATE Power supply (DKU) Warning for alternating current (DKU AC Box) xx 6A BF MODERATE Fan (DKC) Abnormal fan 1x 7x BF MODERATE DKC environment Warning caused by remaining a jumper socket Ax 8x BF MODERATE SVP error Error in two-SVP configuration A2 E3 BF MODERATE Power supply (DKU) AC-DC alarm xx 22 BF MODERATE HDD-PL 56V Low voltage xx 48 BF MODERATE 37V Low voltage xx 4C BF MODERATE Abnormal fan xx 78 BF MODERATE Fan fuse blow xx 79 BF MODERATE Sub-SVP error Others 74 MODERATE Router failure Router failure 03 00 7B MODERATE SVP failure Audit log FTP transfer failed 00 03 7C SERVICE Virus detected (Cleaning finished) 0x F4 7F MODERATE Virus detected (Virus isolated) 0x F5 7F 36 SNMP Failure Trap Reference

Table 18 SNMP Failure Trap Reference Codes (continued)

Alert Level Description Trap Reference Code SIM13 SIM23 SIM22 SERIOUS Virus detected (Virus isolation failed) 0x F6 7F SERIOUS License key Expiration xx F7 7F SERIOUS Exceeded the licensed capacity xx F8 7F SERIOUS Program product invalidated by the expiration of the prerequisite program product. xx F9 7F SERVICE SVP This is not a failure but a test code. This code is output only by the SNMP trap. FF FF 7F SERIOUS Failure with paired volumes Pair suspend due to RIO path blockade xx 0x D4 SERIOUS Pair suspend due to failure detected in M-VOL xx 1x D4 SERIOUS Pair suspend due to failure detected in R-VOL xx 2x D4 SERIOUS Pair suspend due to DFW/DRV CAC off from R-VOL xx 3x D4 SERIOUS Pair suspend due to the suspend report from R-VOL xx 4x D4 SERIOUS Pair suspend due to the Simplex report from R-VOL xx 5x D4 SERIOUS R-VOL has been suspended because an unrecoverable failure occurred in the remote copy connection. xx 6x D4 SERIOUS Abnormal status occurring during ERASE operation in migration copy xx 8x D4 SERIOUS Suspicion of the pair status failure xx Fx D4 SERIOUS Failure with paired volumes A currently used M-VOL has been suspended because an unrecoverable failure occurred in the remote copy connection. x: The CU number yy: The LDEV number yy 0x DB SERIOUS A currently used M-VOL has been suspended because an unrecoverable failure occurred in an M-VOL or the remote copy connection. x: The CU number yy: The LDEV number yy 1x DB SERIOUS A currently used M-VOL has been suspended because an unrecoverable failure occurred in an R-VOL. x: The CU number yy: The LDEV number yy 2x DB 37

Table 18 SNMP Failure Trap Reference Codes (continued)

Alert Level Description Trap Reference Code SIM13 SIM23 SIM22 SERIOUS A currently used M-VOL has been suspended because DFW to R-VOL was prohibited. x: The CU number yy: The LDEV number yy 3x DB SERIOUS A currently used M-VOL has been suspended because an operation for suspending an R-VOL was performed. x: The CU number yy: The LDEV number yy 4x DB SERIOUS A currently used M-VOL has been suspended because an operation for deleting a pair was performed on an R-VOL. x: The CU number yy: The LDEV number yy 5x DB SERIOUS A currently used R-VOL has been suspended because an unrecoverable failure occurred in the remote copy connection. x: The CU number yy: The LDEV number yy 6x DB SERIOUS A currently used R-VOL has been suspended because an unrecoverable failure occurred in R-VOL. x: The CU number yy: The LDEV number yy 7x DB MODERATE MCU detected a moderate-level SIM of RCU. x: The CU number yy: The LDEV number yy Dx DB SERIOUS Failure with paired volumes MCU detected an acute-level or serious-level SIM of RCU. x: The CU number yy: The LDEV number yy Ex DB SERIOUS The M-VOL status and the R-VOL status are not the same. x: The CU number yy: The LDEV number yy Fx DB SERIOUS Volume used as P-VOL has been suspended (Unable to restore path) xx 0x DC SERIOUS Volume used as P-VOL has been suspended (MCU failure detected) xx 1x DC SERIOUS Volume used as P-VOL has been suspended (RCU failure detected) xx 2x DC 38 SNMP Failure Trap Reference

Table 18 SNMP Failure Trap Reference Codes (continued)

Alert Level Description Trap Reference Code SIM13 SIM23 SIM22 SERIOUS Volume used as P-VOL has been suspended (S-VOL suspension detected) xx 4x DC SERIOUS Volume used as P-VOL has been suspended (S-VOL pair deletion detected) xx 5x DC SERIOUS Volume used as S-VOL has been suspended (Unable to restore path) xx 6x DC SERIOUS Volume used as S-VOL has been suspended (RCU failure detected) xx 7x DC SERIOUS Volume used as a P-VOL of Delta resync has been suspended x: The CU number yy: The LDEV number yy 9x DC SERIOUS Volume in the main storage system has been suspended because failure suspend occurs in the remote storage system. yy Ax DC MODERATE Copying ended abnormally xx Dx 47 MODERATE HP StorageWorks XP for FlashCopy Mirroring Software V2 ended abnormally because of loss of data from the shared memory xx E5 47 MODERATE Compatible FlashCopy ended abnormally because of loss of data from the shared memory xx E6 47 MODERATE Pair has been suspended forcibly because of loss of data from the shared memory. 00 E7 47 MODERATE The HP StorageWorks XP Snapshot option ended abnormally due to volatilization of the shared memory. 00 EC 47 MODERATE Failure with paired volumes XP Auto LUN ended abnormally xx Fx 47 MODERATE Copy failure Background copying for canceling relationship ended abnormally xx 0x 4B MODERATE Failure with paired volumes Compatible FlashCopy V2 ended abnormally x: The CU number yy: The LDEV number yy 2x 4B MODERATE The XP Snapshot option ended abnormally. yy 3x 4B MODERATE XP Snapshot Pool Exceeded the pool usage threshold. xx 1x 60 MODERATE Pool blockade xx 2x 60 MODERATE No free area in SM. FF 2F 60 MODERATE XP Thin Provisioning Pool Exceeded the pool usage threshold1. xx 0x 62 MODERATE Exceeded the pool usage threshold2. xx 1x 62 39

Table 18 SNMP Failure Trap Reference Codes (continued)

Alert Level Description Trap Reference Code SIM13 SIM23 SIM22 MODERATE Pool became full. xx 2x 62 MODERATE Pool detected a failure. xx 3x 62 MODERATE No free area in SM. 00 40 62 MODERATE The pool usage threshold is being exceeded. 00 50 62 MODERATE Exceeded the XP Thin Provisioning volume usage threshold. xx 0x 63 The SIM Code for TrueCopy for Mainframe errors is determined by the mode. See “SIM List for TrueCopy for Mainframe Errors” (page 40). SERIOUS Other failures Other failures Others The type of SIM for TrueCopy for Mainframe errors is determined by the mode. Table 19 SIM List for TrueCopy for Mainframe Errors SIM22 Mode D4 D2 D1 D0 SYNC DB D7 D6 D5 SEMISYNC 40 SNMP Failure Trap Reference

This chapter provides troubleshooting information for the HP StorageWorks XP24000/XP20000

SNMP Agent Reference Guide: • “Mitigating SNMP Errors” (page 41) • “Calling HP Technical Support” (page 41) Mitigating SNMP Errors Use setup.exe when you install a secondary SVP. If you do not, traps could be reported to an IP address that is not specified in SNMP settings. This could have serious consequences, including the following: • SNMP Security Function If the SNMP security function is working, and a command is executed from an IP address that is not entered, you will get a no reply return and a certification error is received for a trap. • SNMP Cold Trap Function Depending on your network environment, when the SVP is rebooted you might not receive Microsoft agent SNMP agent cold traps. ◦ ◦ The Microsoft SNMP agent might report Link up/Link down Trap when the SVP reboots. ◦ A number of Link up/Link down Traps may be reported when the OS of the SVP is Windows Vista. • Abnormal Response to SNMP Command If an error occurs in the SVP, traps might not be sent. • Problems Inputting MIB Definition Files If you cannot input two or more MIB definition files because of the specifications of the SNMP manager software, use the MIB definition files for storage system. Error reports include storage system nicknames, which can be used to identify each storage system series (for example, HP StorageWorks XP24000/XP20000 Disk Array and HP StorageWorks XP12000/XP10000 Disk Array). Calling HP Technical Support If you need to call HP technical support, make sure to provide as much information about the problem as possible. Include the circumstances surrounding the error or failure, the storage system Remote Web Console configuration information saved in the floppy diskette(s) by the FD Dump Tool, the exact content of any messages displayed on the Remote Web Console, and the severity levels and reference codes of service information messages (SIMs) displayed on the Status tab of the Remote Web Console main window. For worldwide technical support information, see the HP support website: http://www.hp.com/support Mitigating SNMP Errors 41

7 Support and Other Resources

Related Documentation • HP StorageWorks XP24000/XP20000 LUN Manager User Guide • HP StorageWorks XP24000/XP20000 Disk Array Owner Guide • HP StorageWorks XP24000/XP20000 Remote Web Console User Guide • HP StorageWorks XP10000 Disk Array Owner Guide • HP StorageWorks XP12000 Disk Array Owner Guide • HP StorageWorks XP12000/XP10000 Remote Web Console User Guide You can find these documents on the HP Manuals website: http://www.hp.com/support/manuals In the Storage section, click Storage Software and then select a product. Conventions for Storage Capacity Values HP XP storage systems use the following values to calculate physical storage capacity values (hard disk drives): • 1 KB (kilobyte) = 1,000 bytes • 1 MB (megabyte) = 1,0002 bytes • 1 GB (gigabyte) = 1,0003 bytes • 1 TB (terabyte) = 1,0004 bytes • 1 PB (petabyte) = 1,0005 bytes HP XP storage systems use the following values to calculate logical storage capacity values (logical devices): • 1 KB (kilobyte) = 1,024 bytes • 1 MB (megabyte) = 1,0242 bytes • 1 GB (gigabyte) = 1,0243 bytes • 1 TB (terabyte) = 1,0244 bytes • 1 PB (petabyte) = 1,0245 bytes • 1 block = 512 bytes HP Technical Support For worldwide technical support information, see the HP support website: http://www.hp.com/support Before contacting HP, collect the following information: • Product model names and numbers • Technical support registration number (if applicable) • Product serial numbers • Error messages 42 Support and Other Resources

Operating system type and revision level

• Detailed questions Subscription Service HP recommends that you register your product at the Subscriber’s Choice for Business website: http://www.hp.com/go/e-updates After registering, you will receive email notification of product enhancements, new driver versions, firmware updates, and other product resources. HP Websites For additional information, see the following HP websites: • http://www.hp.com • http://www.hp.com/go/storage • http://www.hp.com/support/manuals • http://www.hp.com/storage/spock Documentation Feedback HP welcomes your feedback. To make comments and suggestions about product documentation, send a message to [email protected]. All submissions become the property of HP. Subscription Service 43

ADaPter. Hardware that connects the LCM to the CHA physically and logically.

C CAC Common access card. CHA Channel adapter. CU Control unit. D DASD Direct-access storage device. DFW DASD fast write. DKC Disk controller. DKU Disk unit. DRV Driver. F FCA Fibre Channel adapter. FD Floppy disk. H HDD Hard disk drive. HTP Hyper Transfer Program. L LCM Link Control Module. LD, LDEV Logical device. An LDEV is created when a RAID group is carved into pieces according to the selected host emulation mode (that is, OPEN-3, OPEN-8, OPEN-9). The number of resulting LDEVs depends on the selected emulation mode. The term LDEV is also known as term volume. M M-VOL Main volume. MCU Main control unit. MIB Management Information Base. P PCB Printed circuit board. PDU Protocol Data Unit. PPRC Peer-to-Peer Remote Copy. R R-SIM Remote service information message. R-VOL Remote volume. RCHA RAID Channel Adapter. RCU Remote control unit. 44 Glossary

Simple Gateway Management Protocol.

SIM Service information message. SM Shared memory. SVP Service processor. A computer built into a disk array. The SVP, used only by an HP service representative, provides a direct interface to the disk array. U UDP User Datagram Protocol. V VOL, vol Volume. 45

SNMP community IP address, 18

SNMP community name, 16 SNMP managers, 14 C changing SNMP community name, 17 conventions storage capacity values, 42 D deleting SNMP community IP address, 19 SNMP community name, 17 SNMP managers, 15 document related documentation, 42 documentation HP website, 42 providing feedback, 43 H help obtaining, 42 HP technical support, 42 I instructions adding SNMP community IP address, 18 adding SNMP community name, 16 adding SNMP managers, 14 changing SNMP community name, 17 deleting SNMP community IP address, 19 deleting SNMP community name, 17 deleting SNMP managers, 15 testing SNMP Trap Report, 20 R related documentation, 42 S SNMP Agent operations adding SNMP community IP address, 18 adding SNMP community name, 16 adding SNMP managers, 14 changing SNMP community name, 17 deleting SNMP community IP address, 19 deleting SNMP community name, 17 deleting SNMP managers, 15 testing SNMP Trap Report, 20 SNMP Information tab, 11 storage capacity values conventions, 42 storage systems supported models, 5 Subscriber's Choice, HP, 43 T technical support, 43 HP, 42 testing SNMP Trap Report, 20 W websites HP, 43 HP Subscriber's Choice for Business, 43 product manuals, 42 46 Index