HP XP20000/XP24000 Reference Manual
Read Online
Read the HP XP20000/XP24000 Reference Manual online using the built-in PDF viewer.
Text of the manual
XP24000/XP20000 SNMP Agent Reference
Guide
Abstract
This guide describes the implementation of SNMP for monitoring HP StorageWorks XP24000/XP20000 storage systems. The
guide lists the monitored storage system components and supported traps, describes the trap protocol and extension MIB, and
explains how to use the GUI to limit SNMP access to specific SNMP managers. The intended audience is a storage system
administrator or authorized service provider with independent knowledge of HP StorageWorks XP storage systems and Remote
Web Console.
HP Part Number: AE131-96088
Published: May 2011
Edition: Thirteenth
© Copyright 2007, 2011 Hewlett-Packard Development Company, L.P.
Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial
Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under
vendor's standard commercial license.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
Acknowledgments
Microsoft, Windows, and Windows XP are U.S. registered trademarks of Microsoft Corporation.
Hitachi and Universal Replicator are registered trademarks of Hitachi, Ltd.
ShadowImage and TrueCopy are registered trademarks of Hitachi, Ltd. and Hitachi Data Systems Corporation
Export Requirements
You may not export or re-export this document or any copy or adaptation in violation of export laws or regulations.
Without limiting the foregoing, this document may not be exported, re-exported, transferred or downloaded to or within (or to a national resident
of) countries under U.S. economic embargo, including Cuba, Iran, North Korea, Sudan, and Syria. This list is subject to change.
This document may not be exported, re-exported, transferred, or downloaded to persons or entities listed on the U.S. Department of Commerce
Denied Persons List, Entity List of proliferation concern or on any U.S. Treasury Department Designated Nationals exclusion list, or to parties directly
or indirectly involved in the development or production of nuclear, chemical, biological weapons, or in missile technology programs as specified
in the U.S. Export Administration Regulations (15 CFR 744).
Revision History
Description
Date
Edition
This edition applies to microcode version 60-01-31-00/00 or later.
June 2007
First
This edition applies to microcode version 60-02-04-00/00 or later.
September 2007
Second
This edition applies to microcode version 60-02-25-00/00 or later.
January 2008
Third
This edition applies to microcode version 60-02-48-00/00 or later.
April 2008
Fourth
This edition applies to microcode version 60-03-04-00/00 or later.
June 2008
Fifth
This edition applies to microcode version 60-03-24-00/00 or later.
September 2008
Sixth
This edition applies to microcode version 60-04-04-00/00 or later.
December 2008
Seventh
This edition applies to microcode version 60-04-13-00/00 or later.
February 2009
Eighth
This edition applies to microcode version 60-05-00-00/00 or later.
June 2009
Ninth
This edition applies to microcode version 60-06-05-00/00 or later.
December 2009
Tenth
This edition applies to microcode version 60-07-00-00/00 or later.
June 2010
Eleventh
This edition applies to microcode version 60-07-50-00/00 or later.
October 2010
Twelfth
This edition applies to microcode version 60-08-01-00/00 or later.
May 2011
Thirteenth
1 Overview of SNMP.....................................................................................5
SNMP Manager Overview........................................................................................................5
SNMP Manager and SNMP Agent Interaction.........................................................................5
Management Information Base (MIB)......................................................................................6
SNMP Agent Overview.............................................................................................................6
System Configuration............................................................................................................6
SNMP Agent Functions.........................................................................................................7
SNMP Manager Functions.........................................................................................................8
Component Status Information...............................................................................................8
2 Using the SNMP GUI................................................................................10
SNMP Information Tab............................................................................................................10
3 Performing SNMP Operations....................................................................14
Adding SNMP Manager IP Addresses.......................................................................................14
Deleting SNMP Manager IP Addresses......................................................................................15
Adding a Community Name....................................................................................................16
Deleting a Community Name...................................................................................................17
Changing a Community Name.................................................................................................17
Adding Community IP Addresses..............................................................................................18
Deleting a Community IP Address.............................................................................................19
Testing the SNMP Trap Report..................................................................................................20
4 SNMP Supported MIB...............................................................................21
Trap Configuration..................................................................................................................21
Extension Trap Specifications...............................................................................................21
Extension Trap PDU............................................................................................................21
Standard MIB Specifications....................................................................................................22
Supported MIB..................................................................................................................22
MIB Access Mode..............................................................................................................22
Object Identifier System......................................................................................................22
Supported Traps................................................................................................................24
MIB Mounting Specifications...............................................................................................24
Extension MIB Specifications....................................................................................................25
Extension MIB Configuration...............................................................................................25
Extension MIB Configuration....................................................................................................32
5 SNMP Failure Trap Reference.....................................................................34
6 Troubleshooting........................................................................................41
Mitigating SNMP Errors...........................................................................................................41
Calling HP Technical Support...................................................................................................41
7 Support and Other Resources.....................................................................42
Related Documentation............................................................................................................42
Conventions for Storage Capacity Values...................................................................................42
HP Technical Support..............................................................................................................42
Contents
3
Subscription Service................................................................................................................43
HP Websites..........................................................................................................................43
Documentation Feedback.........................................................................................................43
Glossary....................................................................................................44
Index.........................................................................................................46
4
Contents
1 Overview of SNMP
This chapter provides an overview of SNMP including an overview of the agent and management
functions:
•
“SNMP Manager Overview” (page 5)
•
“SNMP Agent Overview” (page 6)
•
“SNMP Manager Functions” (page 8)
Unless otherwise specified, the term storage system in this guide refers to the following disk arrays:
•
HP StorageWorks XP24000 Disk Array
•
HP StorageWorks XP20000 Disk Array
The GUI illustrations in this guide were created using a Windows computer with the Internet Explorer
browser. Actual windows may differ depending on the operating system and browser used. GUI
contents also vary with licensed program products, storage system models, and firmware versions.
SNMP Manager Overview
SNMP Manager and SNMP Agent Interaction
The following figure shows an SNMP environment.
Figure 1 SNMP Environment
SNMP is an industry-standard protocol for managing and monitoring network devices, including
disk devices, routers, and hubs. SNMP uses SGMP to manage the TCP/IP gateways.
The standardized configuration and database of network management information is called a
MIB. A standard MIB is common to all SNMP interfaces. An extension MIB is defined by the
particular managed device or protocol.
An SNMP manager monitors the devices, which are referred to as managed nodes. The primary
types of interaction between the SNMP manager and an SNMP agent are polling and trap.
Typically, the SNMP manager polls the SNMP agents on a periodic basis, to determine whether
the device is operating normally. If an abnormal event occurs, the SNMP Agent can report the
condition without a request from the manager, by using a message called trap.
When an SNMP Manager polls the agent, the following dialog takes place:
•
An SNMP manager sends a request packet to an SNMP agent, which requests data regarding
the status of managed node.
•
The SNMP agent sends a response packet back to the SNMP manager.
SNMP Manager Overview
5
SNMP uses the TCP/IP UDP. If the SNMP agent does not respond within a specified time
period, the SNMP manager re-sends the request packet. That time period is set by the system
administrator, taking into account the network traffic and operation policy.
•
If an SNMP agent again does not respond to the re-sent packet, the SNMP manager assumes
that an error has occurred. Depending on the times set for polling and response, this can take
several seconds.
If an SNMP agent detects an abnormal event, it sends a trap to the SNMP manager. However, if
a trap is dropped in transmission, the SNMP manager does not know that it was sent. For this
reason, you should use both polling and traps to determine whether an abnormal event has
occurred.
Management Information Base (MIB)
Each managed device has certain types of information, including the configuration information,
the status information for device, and statistical, which is known collectively as a Management
Information Base (MIB). Each parameter is called a managed object, and it consists of the parameter
name, one or more parameter(s), and a group of operations that can be executed with the object.
The MIB defines the type of information that can be obtained from a managed device, and the
device settings that can be controlled from a management system.
SNMP Agent Overview
System Configuration
The SNMP agent for the HP storage system is on the SVP, which is the computer within the storage
array that manages the storage system. The storage system has an exclusive LAN for communications
between a disk controller and a service processor, and a separate LAN for SNMP. The configuration
of each Network Management Station is determined by the type of SNMP Manager. The following
figure illustrates the SNMP environment.
Figure 2 SNMP Environment Architecture
The following figure shows an example of SNMP operations by using an SNMP manager.
6
Overview of SNMP
Figure 3 Example of SNMP Operations
SNMP Agent Functions
SNMP Traps
An SNMP agent reports a storage system error to a SNMP manager using the trap report function.
If an error occurs, an SNMP agent issues an SNMP trap to an SNMP manager to report a failure.
Issuing an SNMP trap, an SNMP agent also reports a product number, nickname, reference code,
and an identifier of the component.
The following table lists the events that trigger an SNMP agent trap.
Table 1 SNMP Trap Triggering Events
Description
Events
All operations in a storage system stopped.
Acute failure detected.
Operation in a component where a failure occurred
stopped.
Serious failure detected.
Partial failure.
Moderate failure detected.
Minor failure.
Service failure detected.
An SNMP agent logs the most recent 256 traps, so you can see the trap history of a particular
device.
SNMP Agent Operations
The following table lists the types SNMP Agent operations.
Table 2 SNMP Agent Operations
Description
Operation
Obtains a specific MIB object value.
GET REQUEST is the request from an SNMP manager, and
GET RESPONSE is the agent's response to that request.
GET
Continuously finds a MIB object.
GETNEXT REQUEST is the request from an SNMP manager,
and GETNEXT RESPONSE is the agent's response to that
request.
GETNEXT
Reports an event (failure) to an SNMP manager.
TRAP occurs without a request from the SNMP manager.
TRAP
SNMP Agent Overview
7
The following table lists the errors to be reported for the REQUEST operations.
Table 3 SNMP Agent REQUEST Operations
Corrective Action
Description
Error
N/A
Normal
noError(0)
Verify that the requested object is
correct.
•
There are no MIB objects that are
required. (Not supported).
•
The GETNEXT REQUEST command
that is specified for the following
object identifier of the last
supported MIB object is received.
noSuchName(2)
SET operation is not supported.
SET REQUEST is received.
readOnly(4)
Retry the operation.
Error occurred for other reasons.
genErr(5)
SNMP Manager Functions
Component Status Information
You can obtain the status information for certain storage system components from an SNMP
manager. The following table lists the components for which the status can be obtained.
Table 4 Available Component Status Information
Component Name
Area
Processor
Storage System
BUS
Cache
Shared memory
Power supply
Battery
Fan
Others
Hard Disk Drive
Power supply
Disk Unit
Fan
Others
Drive
The following table lists the storage system component status as well as the trap report function.
Table 5 Storage system Component Status Types
Description
Status
Normal operation.
Normal
All operations in a storage system stopped.
Acute failure detected
Operation in a component where a failure occurred stopped.
Serious failure detected
8
Overview of SNMP
Table 5 Storage system Component Status Types (continued)
Description
Status
Partial failure.
Moderate failure detected
Minor failure.
Service failure detected
SNMP Manager Functions
9
2 Using the SNMP GUI
This chapter explains the SNMP information tab:
•
“SNMP Information Tab” (page 10)
SNMP Information Tab
The SNMP IP Security tab allows you to limit SNMP access to specific SNMP managers and to
enter SNMP trap addresses. Click Go – Install – SNMP SNMP IP Security in the menu bar of Remote
Web Console Main window. The SNMP IP Security tab displays. Select the SNMP SNMP IP Security
tab (see “SNMP Information Tab” (page 11)).
Option buttons (left side of the window) and storage system information icons (window upper right
corner) have been omitted from the screen shot. See HP StorageWorks XP24000/XP20000 Remote
Web Console User Guide for an illustration.
10
Using the SNMP GUI
Figure 4 SNMP Information Tab
Table 6 SNMP Information Tab
Description
Item
The Extension SNMP check box is selected if the SNMP
Agent feature is enabled.
To set the SNMP Agent properties from XP Remote Web
Console computer, select Extension SNMP on SNMP
Information window.
Install
The Manager section allows you to add and delete SNMP
manager information (see “Adding SNMP Manager IP
Addresses” (page 14)).
Manager
Displays the IP addresses of registered SNMP managers
from which the SNMP agent accepts requests. If no
manager is registered, the SNMP agent accepts requests
from all managers. You can register up to 32 managers.
IP Address list box
SNMP Information Tab
11
Table 6 SNMP Information Tab (continued)
Description
Item
Enter the IP address of the manager that the SNMP Agent
receives the request from.
•
Ipv4 and Ipv6 addresses can be specified for IP
Address. However, if the OS of SVP is Windows XP
and you enter Ipv6 address and select Apply, an error
message is displayed and the Ipv6 address is not set.
•
Any IP address having all values set to zero (0) cannot
be specified for Ipv4 and Ipv6.
•
The Ipv4 address is specified by entering four (4)
numbers that are separated by periods (.) using a
maximum 3 digits from zero (0) to 255 inclusive (for
example, XXX.XXX.XXX.XXX where X is a number). Enter
the numbers only and do not enter periods.
•
The Ipv6 address is specified by entering eight (8)
hexadecimal numbers that are separated colons (:) using
a maximum 4 digits from zero (0) to FFFF inclusive (for
example,
YYYY:YYYY:YYYY:YYYY:YYYY:YYYY:YYYY:YYYY where
Y is a hexadecimal number). Enter the hexadecimal
numbers only and do not enter the colons. The cursor
can be moved between the entry field using the Tab
key.
IP Address text box
Is selected when entering an Ipv4 address. The Ipv4
address can be entered to IP address text box when this
radio box is selected.
Ipv4 radio box
Is selected when entering Ipv6 address. The Ipv6 address
can be entered to IP address text box when this radio box
is selected.
Ipv6 radio box
Adds new IP addresses to the IP Address list box.
Set
Allows you to add, delete, or change SNMP trap
information. The registered IP address is the trap destination
for the specified community.
•
Each community can have more than one defined IP
address (see “Adding a Community Name” (page 16)
and “Adding Community IP Addresses” (page 18)).
•
You can register up to 32 community names and up to
32 IP addresses per community name.
•
You can use up to 180 alphanumeric characters for a
community name. You cannot use the following: ", \,
;, :, ,, *, ?, <, >, |, /, ^, &, %, and a space before or
after the community name.
Community & Trap
12
Using the SNMP GUI
Table 6 SNMP Information Tab (continued)
Description
Item
Allows you to add, delete or change SNMP system group
information. If system group information has already been
registered, the registered information displays. To register
the system group information, the Extension SNMP check
box must be selected. When you register system group
information, select Apply. System group information is as
follows:
•
Name: Connected storage system name. Remote Web
Console users can change the device name. You can
use up to 180 alphanumeric characters for a device
name. You cannot use the following: ", \, ;, :, ,, *, ?,
<, >, |, /, ^, &, %, . You can use a space in the middle
of the device name, but not before and after and a
space before or after the device name.
The device name is required to use SNMP Agent. Make
sure to document the device name, because settings
will be cleared when SVP is replaced.
•
Contact: Contact information such as personnel and
telephone numbers where you can inquire about the
connected storage system. Remote Web Console users
can change contact information in Modify mode. Enter
contact information using up to 180 alphanumeric
characters (ASCII codes), except for some symbols, such
as ", \, ;, :, ,, *, ?, <, >, |, /, ^, &, and %. You can
also use a space, except before and after contact
information.
A contact name is required to use SNMP Agent. Make
sure to document the contact name, because settings
will be cleared when SVP is replaced.
•
Location: Location of connected storage system. Remote
Web Console users can change device locations with
the modify mode. You must enter a device location using
up to 180 alphanumeric characters (ASCII codes). You
can use a space, except for before and after the
location. You cannot use some symbols, such as ", \,
;, :, ,, *, ?, <, >, |, /, ^, &, and %.
The device location is required to use SNMP Agent.
Make sure to document the device location, because
the settings will be cleared when SVP is replaced.
System Group
Executes test report of the trap to the community registered
in the disk storage system.
Operation in Modify mode is required to use this button.
Operation authority is required as well.
Trap Test
Implements settings made on this window.
Apply
Cancels settings made on this window.
Cancel
SNMP Information Tab
13
3 Performing SNMP Operations
This chapter covers adding and deleting an SNMP manager IP address, adding and deleting a
community name, along with adding and deleting a community IP address:
•
“Adding SNMP Manager IP Addresses” (page 14)
•
“Deleting SNMP Manager IP Addresses” (page 15)
•
“Adding a Community Name” (page 16)
•
“Deleting a Community Name” (page 17)
•
“Changing a Community Name” (page 17)
•
“Adding Community IP Addresses” (page 18)
•
“Deleting a Community IP Address” (page 19)
•
“Testing the SNMP Trap Report” (page 20)
Adding SNMP Manager IP Addresses
To add SNMP Manager IP addresses:
1.
Log on to open Remote Web Console Main window. Change to Modify mode (see the HP
StorageWorks XP24000/XP20000 Remote Web Console User Guide if you need instructions).
2.
Click Go – Environmental Settings – SNMP Information in the menu bar of Remote Web Console
Main window. The SNMP Information window is displayed (see “SNMP Information Tab”
(page 11)).
3.
Select the radio box of Ipv4 or Ipv6 and specify the version of the IP address you enter.
NOTE:
If the OS of SVP is Windows XP and you enter Ipv6 address and select Apply, an
error message is displayed and the Ipv6 address is not set.
4.
Enter desired numerical IP address in IP Address text box (see “Adding SNMP Manager IP
Address (Top: Before Setting, Bottom: After Setting)” (page 15)).
5.
Select Set. The new IP address is added to IP Address list, but the changes are not implemented.
14
Performing SNMP Operations
Select Apply to implement the changes, or select Cancel to cancel the changes, then select
OK on the confirmation message.
Figure 5 Adding SNMP Manager IP Address (Top: Before Setting, Bottom: After Setting)
Deleting SNMP Manager IP Addresses
To delete an SNMP Manager IP address:
1.
Change to Modify mode.
2.
Log on to Remote Web Console. Click Go – Environmental Settings – SNMP Information in the
menu bar of Remote Web Console Main window. The SNMP Information window is displayed
(see “SNMP Information Tab” (page 11)).
3.
Select one or more unwanted IP addresses in IP Address list box. Right-click to display Delete
IP Address menu (see “Delete IP Address Menu” (page 16)).
4.
Select Delete IP Address.
5.
A confirmation message displays. Select OK or Cancel.
6.
Select Apply. Select OK or Cancel.
Deleting SNMP Manager IP Addresses
15
Figure 6 Delete IP Address Menu
Adding a Community Name
To add a community name:
1.
Change to Modify mode.
2.
Log on to Remote Web Console. Click Go – Environmental Settings – SNMP Information in the
menu bar of Remote Web Console Main window. The SNMP Information window is displayed
(see “SNMP Information Tab” (page 11)).
3.
In Community & Trap box, select and right-click Community. Add Community menu displays
(see “Add Community Menu” (page 16)).
4.
Select Add Community. Community dialog box (see “Add Community dialog box” (page 17))
displays.
5.
In the Community text box, enter desired community name. You can use up to 180
alphanumeric characters, except for ", \, ;, :, ,, *, ?, <, >, |, /, ^, &, and %. You can also
use spaces, except at the beginning or the end of the name.
6.
Select OK. The new community name displays in Community & Trap, but the changes are not
yet implemented in the storage system.
7.
To add one or more IP addresses to the new community, see “Adding Community IP Addresses”
(page 18).
8.
To apply changes, select Apply. Select OK or Cancel.
Figure 7 Add Community Menu
16
Performing SNMP Operations
Figure 8 Add Community dialog box
Deleting a Community Name
To delete a community name:
1.
Change to Modify mode.
2.
Log on to open Remote Web Console Main window, click Go – Environmental Settings – SNMP
Information in the menu bar of Remote Web Console Main window. The SNMP Information
window is displayed (see “SNMP Information Tab” (page 11)).
3.
In Community & Trap, select and then right-click the unwanted community. The Delete
Community menu displays (see “Delete Community Menu” (page 17)).
4.
Select the Delete Community command. A confirmation message displays.
5.
Select OK or Cancel. The selected community is deleted from Community & Trap, but the setting
is not yet implemented in the storage system.
6.
Select Apply. Select OK or Cancel on the confirmation message.
Figure 9 Delete Community Menu
Changing a Community Name
To change a community name:
1.
Change to Modify mode (see the HP StorageWorks XP24000/XP20000 Remote Web Console
User Guide if you need instructions).
2.
Log on to Remote Web Console. Click Go – Environmental Settings – SNMP Information in the
menu bar of Remote Web Console Main window. The SNMP Information window is displayed
(see “SNMP Information Tab” (page 11)).
3.
Select and then right-click the community name that you want to change in Community & Trap.
The Change Community menu displays (see “Change Community Menu” (page 18)).
Deleting a Community Name
17
Select Change Community. The Change Community dialog box displays (see “Change
Community dialog box” (page 18)).
5.
In the Community text box, overwrite the old community name with a new community name.
You can use up to 180 alphanumeric characters, except for ", \, ;, :, ,, *, ?, <, >, |, /, ^, &,
and %. You can also use spaces, except at the beginning or the end of the name.
6.
Select OK. The changed community name displays in Community & Trap, but the changes
are not yet implemented in the storage system.
7.
Select Apply. Select OK or Cancel.
Figure 10 Change Community Menu
Figure 11 Change Community dialog box
Adding Community IP Addresses
To add a community IP address:
1.
Log on to Remote Web Console. Click Go – Environmental Settings – SNMP Information in the
menu bar of Remote Web Console Main window. The SNMP Information window is displayed
(see “SNMP Information Tab” (page 11)).
2.
Select and right-click the desired community to display the Add Community menu (see “Add
IP Address Menu” (page 19)).
3.
Select Add IP Address. The Add IP Address dialog box displays (see “IP Address dialog box”
(page 19)).
4.
In IP Address, enter a new IP address or select an existing IP address.
18
Performing SNMP Operations
If the values for an IP address are all set to zero (0), that address cannot be specified for
Ipv4 and Ipv6.
•
The Add IP Address dialog box does not support shortened expression for Ipv6 address.
Enter 8 hexadecimal numbers that are separated colons (:) to a maximum 4 digits from
zero (0) to FFFF inclusive.
•
When the OS of the SVP is Windows XP, if you enter an Ipv6 address and select Apply,
an error message is displayed and the Ipv6 address cannot be set.
5.
Select OK. The new IP address displays in Community & Trap, but the change is not yet
implemented.
6.
Select Apply. Select OK or Cancel.
Figure 12 Add IP Address Menu
Figure 13 IP Address dialog box
Deleting a Community IP Address
To delete a community IP address:
1.
Change to Modify mode.
2.
Log on to Remote Web Console. Click Go – Environmental Settings – SNMP Information in the
menu bar of Remote Web Console Main window. The SNMP Information window is displayed
(see “SNMP Information Tab” (page 11)).
3.
Select SNMP Information.
4.
In Community & Trap, select the unwanted community IP address. Right-click to display Delete
IP Address menu (see “Delete Community IP Address Menu” (page 20)).
Deleting a Community IP Address
19
Select Delete IP Address. A confirmation message displays.
6.
Select OK or Cancel. The selected IP address is deleted from Community & Trap, but the change
is not yet implemented.
7.
Select Apply or Cancel. Select OK on the confirmation message.
Figure 14 Delete Community IP Address Menu
Testing the SNMP Trap Report
To test the SNMP Trap report:
1.
Log on to Remote Web Console. Click Go – Environmental Settings – SNMP Information in the
menu bar of Remote Web Console Main window. The SNMP Information window appears.
2.
Change to Modify mode.
3.
Select Trap Test. A confirmation message displays.
4.
Select OK or Cancel. Verify whether the SNMP trap report, which is reference code 7FFFFF,
is received by the SNMP manager registered in the community.
20
Performing SNMP Operations
4 SNMP Supported MIB
This chapter explains MIB specifications, standard and extension, the SNMP GUI, and trap
configuration:
•
“Trap Configuration” (page 21)
•
“Standard MIB Specifications” (page 22)
•
“Extension MIB Specifications” (page 25)
•
“Extension MIB Configuration” (page 25)
Trap Configuration
Extension Trap Specifications
The specifications of the supported extension trap are as follows.
Table 7 Extension Trap Specifications
Mounting Value
Specification
Operation
—
Specified community name
SNMP Community
4
Trap PDU
Protocol Data Unit (PDU) Type
1.3.6.1.4.1.116.3.11.4.1.1
Agent Identifier
Enterprise ID
—
Agent IP Address
Agent IP Address
—
EnterpriseSpecific
Generic Trap Code
—
See “Specific Trap Codes”
(page 21).
Specific Trap Code
Table 8 Specific Trap Codes
Description
Name
Specific Trap Code
Failure report: All operations in a storage system
stopped.
RaidEventUserAcute
1
Failure report: Operation in a component where a
failure occurred stopped.
RaidEventUserSerious
2
Failure report: Partial failure.
RaidEventUserModerate
3
Failure report: Minor failure.
RaidEventUserService
4
Extension Trap PDU
Failure Report Trap
An extension trap PDU includes the product number of the device that experienced the failure, the
device nickname, and a failure reference code. If you obtain the information with GetRequest
command, access the MIB by using the product number of the device as an index. Table 9 (page
22) shows the failure report trap.
Trap Configuration
21
Table 9 Failure Report Trap
Description
Type
Object Identifier
Name
The product number of the
device that experienced the
failure.
INTEGER
1.3.6.1.4.1.116.5.11.4.2.1
EventTrapSerialNumber
The device nickname.
DisplayString
1.3.6.1.4.1.116.5.11.4.2.2
EventTrapNickname
The failure reference
DisplayString
1.3.6.1.4.1.116.5.11.4.2.3
EventTrapREFCODE
The area where the failure
occurred (Note).
OBJECT
IDENTIFIER
1.3.6.1.4.1.116.5.11.4.2.4
EventTrapPartsID
Failure occurrence date.
DisplayString
1.3.6.1.4.1.116.5.11.4.2.5
EventTrapDate
Failure occurrence time.
DisplayString
1.3.6.1.4.1.116.5.11.4.2.6
EventTrapTime
Detailed information about
a failure.
DisplayString
1.3.6.1.4.1.116.5.11.4.2.7
EventTrapDescription
NOTE:
For example, the object identifier for a failure in a storage system processor would be
1.3.6.1.4.1.116.5.11.4.1.1.6.1.2.
Standard MIB Specifications
Supported MIB
The following table shows the supported MIBs. If you send a GET request for an object (MIB) that
is not supported, you will receive NoSuchName as a GET RESPONSE.
Table 10 Supported MIBs
Supported?
MIB
Supported
system group
Standard MIB: MIB-II
Not supported
interface group
Not supported
at group
Not supported
ip group
Not supported
icmp group
Not supported
tcp group
Not supported
udp group
Not supported
egp group
Not supported
snmp group
Supported
Extension MIB
MIB Access Mode
The access mode for MIB in all communities is read only. If you send a GET request for a SET
operation, you will receive NoSuchName as a GET RESPONSE.
Object Identifier System
An object system supported by SNMP agent is as follows:
22
SNMP Supported MIB
Figure 15 Object System (1)
Figure 16 Object System (2)
Figure 17 Object System (3)
Standard MIB Specifications
23
The following table shows the supported trap types.
Table 11 Extension Trap Types
Description
Trap
Specific Trap Code
All operations in a storage system
stopped.
RaidEventUserAcute
1
Operation in a component where a
failure occurred stopped.
RaidEventUserSerious
2
Partial failure.
RaidEventUserModerate
3
Minor failure.
RaidEventUserService
4
MIB Mounting Specifications
The supported MIB mounting specifications are as follows:
•
mgmt: OBJECT IDENTIFIER ::= {iso(1) org(3) dod(6) internet(1) 2 }
•
mib-2: OBJECT IDENTIFIER ::= {mgmt 1}
An SNMP agent mounts only system groups in mib-2, as shown in the following table.
Table 12 System Groups
Mounted Value
Description
Name
Fixed value
RAID 600
Name of hardware or OS.
sysDescr
{system 1}
Fixed value. See “Object Identifier
System” (page 22).
1.2.6.1.4.1.116.3.11.4.1.1
Object ID indicating the product
identification number.
sysObjectID
{system 2}
Unit: ms
An accumulated time from an SNMP
agent.
sysUpTime
{system 3}
Maximum 180 characters in an ASCII
characters string (see Note)
Input by a user from an SNMP setting
window.
A manager who manages an agent
or a contact address.
sysContact
{system 4}
Maximum 180 characters in an ASCII
characters string (see Note)
Input by a user from an SNMP setting
window.
A given name for managing an agent.
sysName
{system 5}
Maximum 180 characters in an ASCII
characters string (see Note)
Input by a user from an SNMP setting
window.
An agent setup location.
sysLocation
{system 6}
Fixed value
76 (decimal)
Value indicating a service.
sysService
{system 7}
24
SNMP Supported MIB
The following symbols cannot be used: \ , / : ; * ? " < > | & % ^
Extension MIB Specifications
Extension MIB Configuration
“Extension MIB Configuration” (page 25) shows the Extension MIB configuration.
Figure 18 Extension MIB Configuration
raidExMibName
raidExMibName indicates the SVP product name.
raidExMibVersion
raidExMibVersion indicates the microcode version.
Extension MIB Specifications
25
raidExMibAgentVersion indicates the internal version of the extension MIB.
Number of Storage Systems under Control of SVP (raidExMibDkcCount)
raidExMibDkcCount suggests the number of a storage system under the control of SVP.
raidExMibRaidList
raidExMibRaidList indicates the storage system under the control of the SVP.
(raidlistEntry)
raidlistEntry indicates the list of arrays managed by this SVP
26
SNMP Supported MIB
The following table shows the type of information displayed for each storage system
Table 13 Storage system Information
Attribute
Mounted Value
Description
Type
Name
read-only
1-99,999
Storage system product
number (index).
INTEGER
raidlistSerialNumber
::=raidlistEntry(1)
read-only
(Max. 18
characters)
Storage system nickname.
DisplayString
raidlistMibNickName
::=raidlistEntry(2)
read-only
(Max. 10
characters)
Microcode version.
DisplayString
raidlistDKCMainVersion
::=raidlistEntry(3)
read-only
*1
(7 characters)
Storage system product
type.
DisplayString
raidlistDKCProductName
::=raidlistEntry(4)
*1 RAID600 will be indicated as Storage system product type (raidlistDKCProductName).
raidExMibDKCHW
raidExMibDKCHW indicates the status of the storage system components.
dkcHWEntry
dkcHWEntry indicates the status of the storage system components.
Extension MIB Specifications
27
The following table describes the status of the storage system components
Table 14 Storage system component information
Attribute
MIB Value
Description
Type
Name
read-only
1-99,999
Storage system product
number (index).
INTEGER
DKCRaidListIndexSerialNumber
::=dkcHWEntry(1)
read-only
Note
(1 digit)
Status of processor.
INTEGER
DKCHWProcessor
::=dkcHWEntry(2)
read-only
Note
(1 digit)
Status of internal star.
INTEGER
DKCHWCSW
::=dkcHWEntry(3)
read-only
Note
(1 digit)
Status of cache.
INTEGER
DKCHWCache
::=dkcHWEntry(4)
read-only
Note
(1 digit)
Status of shared
memory.
INTEGER
DKCHWSM
::=dkcHWEntry(5)
read-only
Note
(1 digit)
Status of power supply.
INTEGER
DKCHWPS
::=dkcHWEntry(6)
read-only
Note
(1 digit)
Status of battery.
INTEGER
DKCHWBattery
::=dkcHWEntry(7)
read-only
Note
(1 digit)
Status of fan.
INTEGER
DKCHWFan
::=dkcHWEntry(8)
read-only
Note
(1 digit)
Others.
INTEGER
DKCHWEnvironment
::=dkcHWEntry(9)
NOTE:
The status of each component is indicated as follows:
1: Normal.
2: Acute failure detected.
3: Serious failure detected.
4: Moderate failure detected.
5: Service failure detected.
raidExMibDKUHW
raidExMibDKUHW indicates the status of the storage system components.
28
SNMP Supported MIB
dkuHWEntry indicates the status of the disk unit components.
Table 15 Storage System component information
Attribute
MIB Value
Description
Type
Name
read-only
1-99,999
Storage system product
number (index).
INTEGER
DKURaidListIndexSerialNumber
::=dkuHWEntry(1)
read-only
Note
(1 digit)
Status of power supply.
INTEGER
DKUHWPS
::=dkuHWEntry(2)
read-only
Note
(1 digit)
Status of fan.
INTEGER
DKUHWFan
::=dkuHWEntry(3)
read-only
Note
(1 digit)
Status of environment
monitor.
INTEGER
DKUHWEnvironment
::=dkuHWEntry(4)
read-only
Note
(1 digit)
Status of drive.
INTEGER
DKUHWDrive
::=dkuHWEntry(5)
Extension MIB Specifications
29
The status of each component is indicated as follows:
1: Normal.
2: Acute failure detected.
3: Serious failure detected.
4: Moderate failure detected.
5: Service failure detected.
raidExMibDKCHW2
raidExMibDKCHW2 indicates the status of the storage system components.
Table 16 Storage system components information 2
Attribute
MIB Value
Description
Type
Name
read-only
1-99,999
Storage system product
number (index).
INTEGER
DKC2RaidListIndexSerialNumber
::=dkcHW2Entry(1)
read-only
Note
(1 digit)
Information about
environmental failure.
INTEGER
DKCHW2Environment
::=dkcHW2Entry(2)
read-only
Note
(1 digit)
Status of SVP.
INTEGER
DKCHW2SVP
::=dkcHW2Entry(3)
read-only
Note
(1 digit)
Status of program
product failure.
INTEGER
DKCHW2PP
::=dkcHW2Entry(4)
30
SNMP Supported MIB
The status of each component is indicated as follows:
1: Normal.
2: Acute failure detected.
3: Serious failure detected.
4: Moderate failure detected.
5: Service failure detected.
raidExMibTrapList
raidExMibTrapList suggests the history of the failure traps.
Table 17 Failure Information
Attribute
MIB Value
Description
Type
Name
read-only
1-99,999
Storage system product
number (index).
INTEGER
EventListIndexSerialNumber
::=eventTrapEntry(1)
read-only
(Max. 18
characters)
Storage system
nickname.
DisplayString
EventListNickname
::=eventTrapEntry(2)
read-only
1-256
Number of record.
Counter
EventListIndexRecordNo
::=eventTrapEntry(3)
read-only
(6 characters)
Reference code.
DisplayString
EventListREFCODE
::=eventTrapEntry(4)
read-only
yyyy/mm/dd
(10 characters)
Date when the failure
occurred.
DisplayString
EventListData
::=eventTrapEntry(5)
Extension MIB Specifications
31
Table 17 Failure Information (continued)
Attribute
MIB Value
Description
Type
Name
read-only
hh:mm:ss
(18 characters)
Time when the failure
occurred.
DisplayString
EventListTime
::=eventTrapEntry(6)
read-only
(maximum 256
characters)
Detailed information
about the failure.
DisplayString
EventListDescription
::=eventTrapEntry(7)
Extension MIB Configuration
Figure 19 Extension MIB Configuration (1)
32
SNMP Supported MIB
5 SNMP Failure Trap Reference
This chapter shows the alert level, the trap reference code, the description, and the alert level:
•
“SNMP Failure Trap Reference Codes” (page 34)
•
“SIM List for TrueCopy for Mainframe Errors” (page 40)
The following table shows the alert level, the trap reference code, the description, and the alert
level.
Table 18 SNMP Failure Trap Reference Codes
Alert Level
Description
Trap Reference Code
SIM13
SIM23
SIM22
MODERATE
Processor
LCM hard error
yz
3x
21
MODERATE
ADP blockade
xy
72
21
MODERATE
RIO path blockade
xy
80
21
MODERATE
Remote copy logical path blockade
(notification of failure from extender)
xy
82
21
SERIOUS
Link data transfer error
xy
93
21
SERIOUS
Link data transfer error
xy
94
21
MODERATE
HTP hardware error
xy
A0
21
MODERATE
HTP path blockade
xy
A2
21
MODERATE
HTP blockade
xy
A3
21
MODERATE
External port blockade
x: The CHA package number
y: The number of the port in the package
xy
D0
21
SERVICE
External device response timeout
x: The CHA package number
y: The number of the port in the package
xy
D2
21
MODERATE
Processor blockade
xy
73
30
MODERATE
FM failure
xy
75
30
Acute
CHA PCB blockade
xx=00:Fibre, xx=01:MFibre,
xx=02:Serial
xx=FF:All CHA
xx
A0
30
Acute
DKC blockade
00
A1
30
MODERATE
Processor blockade
xy
73
31
MODERATE
FM failure
xy
75
31
Acute
DKA PCB blockade
00
A0
31
MODERATE
DRR blockade
xy
82
CF
MODERATE
FCA blockade
xy
83
CF
34
SNMP Failure Trap Reference
Table 18 SNMP Failure Trap Reference Codes (continued)
Alert Level
Description
Trap Reference Code
SIM13
SIM23
SIM22
SERVICE
Cache
Cache Module Blockade processing
finished
xy
C2
FF
SERVICE
Cache Package Blockade processing
finished
0x
C3
FF
SERVICE
Cache temporary failure
xy
F1
FF
MODERATE
Module blockade
xy
F2
FF
MODERATE
Package blockade
0x
F3
FF
SERIOUS
Module group blocking
0x
F4
FF
SERIOUS
Area blocking
0x
E2
FF
SERIOUS
HP StorageWorks XP for Compatible
Parallel Access Volumes Software
microcode volatilization
01
E9
FF
SERVICE
Recovery of area blocked temporarily
was completed
0x
EA
FF
SERVICE
Temporary blockade
0x
EE
FF
MODERATE
Drive
Drive port blockade (Path 0 side)
xx
8y
DF
MODERATE
Drive port blockade (Path 1 side)
xx
9y
DF
SERIOUS
LDEV blockade (Fibre blockade) (Path 0
side)
xx
Ay
DF
SERIOUS
LDEV blockade (Fibre blockade) (Path 1
side)
xx
By
DF
SERIOUS
Drive failure
Drive blockade (Drive system)
xxx: The drive number
xx
0x
EF
SERIOUS
Drive
Drive blockade (Drive system)
xx
1y
EF
SERVICE
Drive blockade (Drive system)
xx
2y
EF
MODERATE
External volume write error
yy
5x
EF
SERIOUS
LDEV blockade (Drive system)
xx
9y
EF
SERIOUS
Device connecting to external storage
system is blocked.
00
D0
EF
MODERATE
External volume read error
yy
5x
FF
SERIOUS
Drive failure
Drive blockade (Media system)
xxx: The drive number
xx
Bx
43
SERIOUS
Drive
Drive blockade (Media system)
xx
Cy
43
SERVICE
Correction copy start
xx
1y
45
SERVICE
Correction copy normal end
xx
2y
45
SERIOUS
Correction copy abnormal end
xx
3y
45
SERVICE
Correction copy warning end
xx
5y
45
SERVICE
Dynamic sparing start
xx
1y
46
35
Table 18 SNMP Failure Trap Reference Codes (continued)
Alert Level
Description
Trap Reference Code
SIM13
SIM23
SIM22
SERVICE
Dynamic sparing normal end
xx
2y
46
MODERATE
Dynamic sparing abnormal end
xx
3y
46
SERVICE
Dynamic sparing warning end
xx
5y
46
SERVICE
Sidefile 40% over
xx
0x
49
MODERATE
Power supply
(DKU)
HDU power supply shutdown detected
xy
50
AC
MODERATE
Environmental
failure
Fuse failure
A5
0x
BF
MODERATE
Fuse failure
A6
0x
BF
MODERATE
Abnormal temperature
1x
1x
BF
MODERATE
Power supply
(DKC)
Alarm for voltage
1x
2x
BF
MODERATE
Warning for power supply
1x
4x
BF
MODERATE
Power supply
Warning of power supply box
A5
41
BF
MODERATE
Warning of power supply box
A6
41
BF
MODERATE
Battery
Warning for battery
1x
5x
BF
MODERATE
Warning for battery
Bx
5x
BF
MODERATE
Battery
Warning for battery
xx
58
BF
MODERATE
DKC environment
Warning for alternating current
D0
60
BF
MODERATE
(3 phase AC Box)
D1
60
BF
MODERATE
Power supply
(DKU)
Warning for alternating current (DKU AC
Box)
xx
6A
BF
MODERATE
Fan (DKC)
Abnormal fan
1x
7x
BF
MODERATE
DKC environment
Warning caused by remaining a jumper
socket
Ax
8x
BF
MODERATE
SVP error
Error in two-SVP configuration
A2
E3
BF
MODERATE
Power supply
(DKU)
AC-DC alarm
xx
22
BF
MODERATE
HDD-PL
56V Low voltage
xx
48
BF
MODERATE
37V Low voltage
xx
4C
BF
MODERATE
Abnormal fan
xx
78
BF
MODERATE
Fan fuse blow
xx
79
BF
MODERATE
Sub-SVP error
Others
74
MODERATE
Router failure
Router failure
03
00
7B
MODERATE
SVP failure
Audit log FTP transfer failed
00
03
7C
SERVICE
Virus detected (Cleaning finished)
0x
F4
7F
MODERATE
Virus detected (Virus isolated)
0x
F5
7F
36
SNMP Failure Trap Reference
Table 18 SNMP Failure Trap Reference Codes (continued)
Alert Level
Description
Trap Reference Code
SIM13
SIM23
SIM22
SERIOUS
Virus detected (Virus isolation failed)
0x
F6
7F
SERIOUS
License key
Expiration
xx
F7
7F
SERIOUS
Exceeded the licensed capacity
xx
F8
7F
SERIOUS
Program product invalidated by the
expiration of the prerequisite program
product.
xx
F9
7F
SERVICE
SVP
This is not a failure but a test code. This
code is output only by the SNMP trap.
FF
FF
7F
SERIOUS
Failure with paired
volumes
Pair suspend due to RIO path blockade
xx
0x
D4
SERIOUS
Pair suspend due to failure detected in
M-VOL
xx
1x
D4
SERIOUS
Pair suspend due to failure detected in
R-VOL
xx
2x
D4
SERIOUS
Pair suspend due to DFW/DRV CAC off
from R-VOL
xx
3x
D4
SERIOUS
Pair suspend due to the suspend report
from R-VOL
xx
4x
D4
SERIOUS
Pair suspend due to the Simplex report
from R-VOL
xx
5x
D4
SERIOUS
R-VOL has been suspended because an
unrecoverable failure occurred in the
remote copy connection.
xx
6x
D4
SERIOUS
Abnormal status occurring during ERASE
operation in migration copy
xx
8x
D4
SERIOUS
Suspicion of the pair status failure
xx
Fx
D4
SERIOUS
Failure with paired
volumes
A currently used M-VOL has been
suspended because an unrecoverable
failure occurred in the remote copy
connection.
x: The CU number
yy: The LDEV number
yy
0x
DB
SERIOUS
A currently used M-VOL has been
suspended because an unrecoverable
failure occurred in an M-VOL or the
remote copy connection.
x: The CU number
yy: The LDEV number
yy
1x
DB
SERIOUS
A currently used M-VOL has been
suspended because an unrecoverable
failure occurred in an R-VOL.
x: The CU number
yy: The LDEV number
yy
2x
DB
37
Table 18 SNMP Failure Trap Reference Codes (continued)
Alert Level
Description
Trap Reference Code
SIM13
SIM23
SIM22
SERIOUS
A currently used M-VOL has been
suspended because DFW to R-VOL was
prohibited.
x: The CU number
yy: The LDEV number
yy
3x
DB
SERIOUS
A currently used M-VOL has been
suspended because an operation for
suspending an R-VOL was performed.
x: The CU number
yy: The LDEV number
yy
4x
DB
SERIOUS
A currently used M-VOL has been
suspended because an operation for
deleting a pair was performed on an
R-VOL.
x: The CU number
yy: The LDEV number
yy
5x
DB
SERIOUS
A currently used R-VOL has been
suspended because an unrecoverable
failure occurred in the remote copy
connection.
x: The CU number
yy: The LDEV number
yy
6x
DB
SERIOUS
A currently used R-VOL has been
suspended because an unrecoverable
failure occurred in R-VOL.
x: The CU number
yy: The LDEV number
yy
7x
DB
MODERATE
MCU detected a moderate-level SIM of
RCU.
x: The CU number
yy: The LDEV number
yy
Dx
DB
SERIOUS
Failure with paired
volumes
MCU detected an acute-level or
serious-level SIM of RCU.
x: The CU number
yy: The LDEV number
yy
Ex
DB
SERIOUS
The M-VOL status and the R-VOL status
are not the same.
x: The CU number
yy: The LDEV number
yy
Fx
DB
SERIOUS
Volume used as P-VOL has been
suspended (Unable to restore path)
xx
0x
DC
SERIOUS
Volume used as P-VOL has been
suspended (MCU failure detected)
xx
1x
DC
SERIOUS
Volume used as P-VOL has been
suspended (RCU failure detected)
xx
2x
DC
38
SNMP Failure Trap Reference
Table 18 SNMP Failure Trap Reference Codes (continued)
Alert Level
Description
Trap Reference Code
SIM13
SIM23
SIM22
SERIOUS
Volume used as P-VOL has been
suspended (S-VOL suspension detected)
xx
4x
DC
SERIOUS
Volume used as P-VOL has been
suspended (S-VOL pair deletion detected)
xx
5x
DC
SERIOUS
Volume used as S-VOL has been
suspended (Unable to restore path)
xx
6x
DC
SERIOUS
Volume used as S-VOL has been
suspended (RCU failure detected)
xx
7x
DC
SERIOUS
Volume used as a P-VOL of Delta resync
has been suspended
x: The CU number
yy: The LDEV number
yy
9x
DC
SERIOUS
Volume in the main storage system has
been suspended because failure suspend
occurs in the remote storage system.
yy
Ax
DC
MODERATE
Copying ended abnormally
xx
Dx
47
MODERATE
HP StorageWorks XP for FlashCopy
Mirroring Software V2 ended abnormally
because of loss of data from the shared
memory
xx
E5
47
MODERATE
Compatible FlashCopy ended abnormally
because of loss of data from the shared
memory
xx
E6
47
MODERATE
Pair has been suspended forcibly
because of loss of data from the shared
memory.
00
E7
47
MODERATE
The HP StorageWorks XP Snapshot
option ended abnormally due to
volatilization of the shared memory.
00
EC
47
MODERATE
Failure with paired
volumes
XP Auto LUN ended abnormally
xx
Fx
47
MODERATE
Copy failure
Background copying for canceling
relationship ended abnormally
xx
0x
4B
MODERATE
Failure with paired
volumes
Compatible FlashCopy V2 ended
abnormally
x: The CU number
yy: The LDEV number
yy
2x
4B
MODERATE
The XP Snapshot option ended
abnormally.
yy
3x
4B
MODERATE
XP Snapshot Pool
Exceeded the pool usage threshold.
xx
1x
60
MODERATE
Pool blockade
xx
2x
60
MODERATE
No free area in SM.
FF
2F
60
MODERATE
XP Thin
Provisioning Pool
Exceeded the pool usage threshold1.
xx
0x
62
MODERATE
Exceeded the pool usage threshold2.
xx
1x
62
39
Table 18 SNMP Failure Trap Reference Codes (continued)
Alert Level
Description
Trap Reference Code
SIM13
SIM23
SIM22
MODERATE
Pool became full.
xx
2x
62
MODERATE
Pool detected a failure.
xx
3x
62
MODERATE
No free area in SM.
00
40
62
MODERATE
The pool usage threshold is being
exceeded.
00
50
62
MODERATE
Exceeded the XP Thin Provisioning
volume usage threshold.
xx
0x
63
The SIM Code for TrueCopy for Mainframe errors is determined by the mode. See “SIM List for TrueCopy
for Mainframe Errors” (page 40).
SERIOUS
Other failures
Other failures
Others
The type of SIM for TrueCopy for Mainframe errors is determined by the mode.
Table 19 SIM List for TrueCopy for Mainframe Errors
SIM22
Mode
D4
D2
D1
D0
SYNC
DB
D7
D6
D5
SEMISYNC
40
SNMP Failure Trap Reference
This chapter provides troubleshooting information for the HP StorageWorks XP24000/XP20000
SNMP Agent Reference Guide:
•
“Mitigating SNMP Errors” (page 41)
•
“Calling HP Technical Support” (page 41)
Mitigating SNMP Errors
Use setup.exe when you install a secondary SVP. If you do not, traps could be reported to an IP
address that is not specified in SNMP settings. This could have serious consequences, including
the following:
•
SNMP Security Function
If the SNMP security function is working, and a command is executed from an IP address that
is not entered, you will get a no reply return and a certification error is received for a trap.
•
SNMP Cold Trap Function
Depending on your network environment, when the SVP is rebooted you might not receive
Microsoft agent SNMP agent cold traps.
◦
◦
The Microsoft SNMP agent might report Link up/Link down Trap when the SVP reboots.
◦
A number of Link up/Link down Traps may be reported when the OS of the SVP is
Windows Vista.
•
Abnormal Response to SNMP Command
If an error occurs in the SVP, traps might not be sent.
•
Problems Inputting MIB Definition Files
If you cannot input two or more MIB definition files because of the specifications of the SNMP
manager software, use the MIB definition files for storage system. Error reports include storage
system nicknames, which can be used to identify each storage system series (for example, HP
StorageWorks XP24000/XP20000 Disk Array and HP StorageWorks XP12000/XP10000
Disk Array).
Calling HP Technical Support
If you need to call HP technical support, make sure to provide as much information about the
problem as possible. Include the circumstances surrounding the error or failure, the storage system
Remote Web Console configuration information saved in the floppy diskette(s) by the FD Dump
Tool, the exact content of any messages displayed on the Remote Web Console, and the severity
levels and reference codes of service information messages (SIMs) displayed on the Status tab of
the Remote Web Console main window.
For worldwide technical support information, see the HP support website:
http://www.hp.com/support
Mitigating SNMP Errors
41
7 Support and Other Resources
Related Documentation
•
HP StorageWorks XP24000/XP20000 LUN Manager User Guide
•
HP StorageWorks XP24000/XP20000 Disk Array Owner Guide
•
HP StorageWorks XP24000/XP20000 Remote Web Console User Guide
•
HP StorageWorks XP10000 Disk Array Owner Guide
•
HP StorageWorks XP12000 Disk Array Owner Guide
•
HP StorageWorks XP12000/XP10000 Remote Web Console User Guide
You can find these documents on the HP Manuals website:
http://www.hp.com/support/manuals
In the Storage section, click Storage Software and then select a product.
Conventions for Storage Capacity Values
HP XP storage systems use the following values to calculate physical storage capacity values (hard
disk drives):
•
1 KB (kilobyte) = 1,000 bytes
•
1 MB (megabyte) = 1,0002 bytes
•
1 GB (gigabyte) = 1,0003 bytes
•
1 TB (terabyte) = 1,0004 bytes
•
1 PB (petabyte) = 1,0005 bytes
HP XP storage systems use the following values to calculate logical storage capacity values (logical
devices):
•
1 KB (kilobyte) = 1,024 bytes
•
1 MB (megabyte) = 1,0242 bytes
•
1 GB (gigabyte) = 1,0243 bytes
•
1 TB (terabyte) = 1,0244 bytes
•
1 PB (petabyte) = 1,0245 bytes
•
1 block = 512 bytes
HP Technical Support
For worldwide technical support information, see the HP support website:
http://www.hp.com/support
Before contacting HP, collect the following information:
•
Product model names and numbers
•
Technical support registration number (if applicable)
•
Product serial numbers
•
Error messages
42
Support and Other Resources
Operating system type and revision level
•
Detailed questions
Subscription Service
HP recommends that you register your product at the Subscriber’s Choice for Business website:
http://www.hp.com/go/e-updates
After registering, you will receive email notification of product enhancements, new driver versions,
firmware updates, and other product resources.
HP Websites
For additional information, see the following HP websites:
•
http://www.hp.com
•
http://www.hp.com/go/storage
•
http://www.hp.com/support/manuals
•
http://www.hp.com/storage/spock
Documentation Feedback
HP welcomes your feedback.
To make comments and suggestions about product documentation, send a message to
[email protected]. All submissions become the property of HP.
Subscription Service
43
ADaPter. Hardware that connects the LCM to the CHA physically and logically.
C
CAC
Common access card.
CHA
Channel adapter.
CU
Control unit.
D
DASD
Direct-access storage device.
DFW
DASD fast write.
DKC
Disk controller.
DKU
Disk unit.
DRV
Driver.
F
FCA
Fibre Channel adapter.
FD
Floppy disk.
H
HDD
Hard disk drive.
HTP
Hyper Transfer Program.
L
LCM
Link Control Module.
LD, LDEV
Logical device. An LDEV is created when a RAID group is carved into pieces according to the
selected host emulation mode (that is, OPEN-3, OPEN-8, OPEN-9). The number of resulting LDEVs
depends on the selected emulation mode. The term LDEV is also known as term volume.
M
M-VOL
Main volume.
MCU
Main control unit.
MIB
Management Information Base.
P
PCB
Printed circuit board.
PDU
Protocol Data Unit.
PPRC
Peer-to-Peer Remote Copy.
R
R-SIM
Remote service information message.
R-VOL
Remote volume.
RCHA
RAID Channel Adapter.
RCU
Remote control unit.
44
Glossary
Simple Gateway Management Protocol.
SIM
Service information message.
SM
Shared memory.
SVP
Service processor. A computer built into a disk array. The SVP, used only by an HP service
representative, provides a direct interface to the disk array.
U
UDP
User Datagram Protocol.
V
VOL, vol
Volume.
45
SNMP community IP address, 18
SNMP community name, 16
SNMP managers, 14
C
changing
SNMP community name, 17
conventions
storage capacity values, 42
D
deleting
SNMP community IP address, 19
SNMP community name, 17
SNMP managers, 15
document
related documentation, 42
documentation
HP website, 42
providing feedback, 43
H
help
obtaining, 42
HP
technical support, 42
I
instructions
adding SNMP community IP address, 18
adding SNMP community name, 16
adding SNMP managers, 14
changing SNMP community name, 17
deleting SNMP community IP address, 19
deleting SNMP community name, 17
deleting SNMP managers, 15
testing SNMP Trap Report, 20
R
related documentation, 42
S
SNMP Agent operations
adding SNMP community IP address, 18
adding SNMP community name, 16
adding SNMP managers, 14
changing SNMP community name, 17
deleting SNMP community IP address, 19
deleting SNMP community name, 17
deleting SNMP managers, 15
testing SNMP Trap Report, 20
SNMP Information tab, 11
storage capacity values
conventions, 42
storage systems
supported models, 5
Subscriber's Choice, HP, 43
T
technical support, 43
HP, 42
testing
SNMP Trap Report, 20
W
websites
HP, 43
HP Subscriber's Choice for Business, 43
product manuals, 42
46
Index