As you follow these instructions, you will
notice WARNING and CAUTION symbols.
This blocked information is important for the
safe and efficient installation of Sub-Zero
equipment. There are two types of potential
hazards that may occur during installation.
Another footnote we would like to identify is
IM
INSTALLATION R E C O M M E N DAT I O N S
S I T E P R E PA R AT I O N
Make sure that the finished rough opening
where the Undercounter unit is to be installed
is properly prepared. Refer to the Installation
Specifications illustration for rough opening
dimensions, door swing clearance and location
of electrical and plumbing (Model UC-24C).
IMPORTANT NOTE: To
ELECTRICAL R E Q U I R E M E N T S
A 115 V AC, 60 Hz, 15 amp circuit breaker and
electrical supply are required. A separate
circuit, servicing only this appliance, is
required.
The power supply cord has a 3-prong ground-
ing plug, which must be plugged into a mating
3-prong grounding-type wall receptacle. Follow
the National Electrical Code and local codes
Dimensions in parentheses are in
millimeters unless otherwise specified.
UNDERCOUNTER I N S TA L L AT I O N I N S T R U C T I O N S
UNPACKING A N D MOVING
Uncrate the unit and remove its wood base.
Remove all packing materials and tape.
IMPORTANT NOTE: Do not discard the
kickplate, anti-tip bracket, hardware and the
shipping bolts that hold the wood to th
ANTI-TIP BRACKET I N S TA L L AT I O N
An anti-tip bracket and hardware is provided
with the Undercounter unit. The anti-tip
bracket must be installed on a solid base to
prevent tipover in case several loaded wine
shelves are extended at the same time.
The anti-tip bracket should be attached to the
wall behind the unit with the bracket flange
located immedia
Dimensions in parentheses are in
millimeters unless otherwise specified.
UNDERCOUNTER I N S TA L L AT I O N I N S T R U C T I O N S
DOOR PANEL I N S TA L L AT I O N
M O D E L S U C - 2 4 R A N D U C - 2 4 C
Models UC-24R and UC-24C can be fitted with
a custom overlay or stainless steel door front
panel. A classic stainless steel door panel with
tubular
UNDERCOUNTER I N S TA L L AT I O N I N S T R U C T I O N S
The screw holes inside the door are hidden
under a cover flap on the door gasket. It is
necessary to lift the flap to insert the screws.
Use as many screws as necessary to hold the
door panel in place properly.
IMPORTANT NOTE: After the first three or
four mounting screws are in place, but not
com