Table of Contents

Important Information.......................................... 5 Tools .................................................................... 6 Uninstalling the Existing Unit .............................. 7 Installing the Thermostat ................................... 12 installing the wall plate ................................. 12 connecting the wires ..................................... 16 attaching the thermostat .................... ...

Thank you for choosing a Hunter programmable thermostat.

Your new Hunter thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for complete operation instructions. The Hunter Technical Support Group is available from 7 am to 7 pm CST M-F and 8 am to 5 pm Saturday. They may be reached toll-free at 1-888-830-1326. Set & Save Programmable Th ...

This thermostat is designed to work on the following

heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – Fired Boilers Gas – Milivolt Systems Oil – Fired Boilers Oil – Fired Furnace Electric Furnace Electric Air Conditioning This thermostat is not designed for heat pump systems or 110/220 V baseboard heating systems. If you are unsure what kind of heating and cooling system you have, please contact a qualified HVAC ...

This thermostat includes two #8 slotted screws and two wall

anchors for mounting. To install your new thermostat, you will need the following supplies: Flat-head screwdriver ............................................................................................. Small Phillips-head screwdriver ............................................................................................. Hammer ........................................................... ...

NOTICE! Do not disconnect the wires from

the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper reconnection.  ...

1. Turn the system power OFF from the existing thermostat. Turn

the power to the HVAC system OFF at the main power panel or at the furnace. (Failure to turn off the power to the existing thermostat before removal could damage your system.) 2. Remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have multiple covers, screws or other locking devices that must be removed or disengaged.) 3. Locate, but do not disconn ...

if your existing

thermostat is marked... label the wire with this sticker: G / F G G W / H W W Y / C* / M Y Y RC / VC RC RC RH / R / VR / 4 RH RH 24 Volt 24 Volt cool air conditioning compressor heating fan 10 ...

4. Using the provided stickers, label each wire according to the

chart. (If the terminals are not labeled, contact a qualified HVAC technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identification. *If wires marked Y & C are both present, C may be a Common wire and should not be used. If you have a wire marked C, do not connect it to any terminal. This ...

installing the thermostat

INSTALLING THE WALL PLATE 1. Remove the wall plate from the new thermostat by pressing the release tab on the bottom of the thermostat. 2. Position the new wall plate on the wall and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate, or if there are no existing holes, visually level the wall plate and mark the wall for two holes. 13 ...

4. Remove the wall plate and drill two 3/16” holes where

marked. 5. Tap the plastic anchors into the holes until they are flush with the wall. 6. Reposition the wall plate on the wall, pulling the wires through the opening. Insert the mounting screws through the wall plate and into the anchors. Verify that the wall plate is visually level and securely tighten both screws. installing the thermostat, cont. 15 ...

installing the thermostat, cont.

CONNECTING THE WIRES 1. Loosen, but do not remove, the terminal screws. Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper. If you do not have both an RH and RC wire, leave the jumper in place. 2. Match and connect the wires from the wall to the terminals as shown. Wires should be inserted b ...

18 DISABLE ENABLE RECO- VERY HG HE W/B Y/O RH RC G AM HEAT 4 T Thermostat Cover System Switch Fan Switch ...

ATTACHING THE THERMOSTAT

1. Lift the thermostat cover and set the SYSTEM switch to OFF and the FAN switch to AUTO. 2. Locate the HE/HG switch on the back of the thermostat. Set the switch to HG (default) for gas furnace and oil burners. Set the switch to HE for electric furnaces. (The switch has no effect when the system is set to cooling mode.) 3. Locate the Auto Recovery switch on the back of the thermostat. If you wish to use the Energy Star compl ...