Intermatic LC2000 Important Operating Instructions
Text of Intermatic LC2000 Important Operating Instructions
Common problems - read first!
1. Do not face the photocell into the midday sun. If installed
on the south side of a building, face east or west or point the
photo control down toward the ground. The best direction to
face the photo control is north.
2. Do not face the photocell where it can see artificial light.
Light from windows, signs, street lights, etc., will cause the
photo control not to switch on. The photo control should not
be positioned so
Fuse blows when
Load exceeds fuse rating.
Reduce load to within fuse rating.
power is connected.
Photo control is incorrectly wired.
Check wiring.
Short in wiring.
Load lamp blinks
Photo control is incorrectly wired.
Rewire as shown in wiring diagram.
during the day, but is
on at night.
Load lamp blinks at
Too much light is striking photo eye.
Reorient or relocate photo control.
night, but is off during
Light fr