Common problems - read first!

1. Do not face the photocell into the midday sun. If installed on the south side of a building, face east or west or point the photo control down toward the ground. The best direction to face the photo control is north. 2. Do not face the photocell where it can see artificial light. Light from windows, signs, street lights, etc., will cause the photo control not to switch on. The photo control should not be positioned so

Fuse blows when

Load exceeds fuse rating. Reduce load to within fuse rating. power is connected. Photo control is incorrectly wired. Check wiring. Short in wiring. Load lamp blinks Photo control is incorrectly wired. Rewire as shown in wiring diagram. during the day, but is on at night. Load lamp blinks at Too much light is striking photo eye. Reorient or relocate photo control. night, but is off during Light fr