Kramer 905 Operation & User’s Manual
Text of Kramer 905 Operation & User’s Manual
Kramer 905 Your 905 Power Amplifier
3
5
Installing the 905 in a Rack
6
6
Connecting the 905 Power Amplifier
7
6.1
Connecting the 905 via RS-232
8
7
Operating the 905 Power Amplifier
8
7.1
Using the Front Panel Buttons
8
7.1.1
Adjusting the Volume
8
7.1.2
Muting the Output
8
7.1.3
Mixing the Input Signals
9
7.2
Using the Audio Control Program
9
7.3
Using Serial Commands
10
8
Tech
KRAMER: SIMPLE CREATIVE TECHNOLOGY
Contents
ii
Figures
Figure 1: 905 Power Amplifier
4
Figure 2: Connecting the 905 Power Amplifier
7
Figure 3: Audio Control Window
10
Tables
Table 1: 905 Power Amplifier Functions
5
Table 2: 905 Technical Specifications
11
Table 3: Communication Parameters
11
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been
providing a world of unique, creative, and affordable solutions to the vast
range of problems that confront the video, audio, presentation, and
broadcasting professional on a daily basis. In recent years, we have
redesigned and upgraded most of our line, making the best even better! Our
1,000-plus different models now appear in 11 groups1
Thank you for purc
KRAMER: SIMPLE CREATIVE TECHNOLOGY Contents
2
2.1
Quick Start
This quick start chart summarizes the basic setup and operation steps.
The Kramer 905 is a high-performance power amplifier for line-level stereo
audio signals. It accepts either a stereo audio signal on an RCA connector or
a balanced stereo audio signal on a terminal block connector. It delivers a
speaker output of 80 watts RMS per channel into a 4Ω load on a 10A 4-pin
terminal block connector.
The 905 features:
• Two input selector buttons
• Two buttons for adjusting the volume and a mute button
Your 905 Power Amplifier 5
Table 1: 905 Power Amplifier Functions
#
Feature
Function
1
INPUT SELECTOR 1,2 Buttons
Press to select the input audio source 1 (unbalanced) or 2
(balanced)
2
Volume ↑↓ Buttons
Press to increase or decrease the output volume
3
MUTE Button
Press to turn off or turn on the audio output. The button
illuminates when the audio output is disabled
4
INPUT 1 Left and Right RCA Connectors
Connect to the unbalanced stereo audio source
KRAMER: SIMPLE CREATIVE TECHNOLOGY Installing the 905 in a Rack
6
5
Installing the 905 in a Rack
This section provides instructions for rack mounting the 1U unit.
Connecting the 905 Power Amplifier
7
6
Connecting the 905 Power Amplifier
To connect the 905, as illustrated in the example in Figure 2, do the following:
1. Connect an unbalanced stereo audio source (for example, the unbalanced
output of the DVD 1 player) to the L and R INPUT 1 RCA connectors.
2. Connect a balanced stereo audio source (for example, the balanced stereo
audio output of the DVD 2 player) to the INPUT 2 terminal block
connector.
3. Connect th
KRAMER: SIMPLE CREATIVE TECHNOLOGY Operating the 905 Power Amplifier
8
6.1
Connecting the 905 via RS-232
You can connect to the 905 via an RS-232 connection using, for example, a
PC. Note that a null-modem adapter/connection is not required.
To connect to the 905 via RS-232:
• Connect the RS-232 9-pin D-sub rear panel port on the 905 unit via
a 9-wire straight cable (only pin 2 to pin 2, pin 3 to pin 3, and pin 5
to pin 5 need to be connected) to the R
Kramer 905 Operating the 905 Power Amplifier
9
7.1.3 Mixing the Input Signals
You can mix the input signals using the two INPUT SELECTOR buttons.
To mix the signals, do the following:
1. Press the selected input twice.
The other input button illuminates and both buttons enter the mixing mode.
2. Press and hold the selected input button for 2 or 3 seconds until it blinks.
3. Press the up and down arrows to adjust the mixing rate between the inputs.
To exit the mixing
KRAMER: SIMPLE CREATIVE TECHNOLOGY Operating the 905 Power Amplifier
10
Figure 3: Audio Control Window
7.3
Using Serial Commands
To operate your device using serial commands, you need to install Kramer's
control software that can be downloaded from the Kramer Electronics Web
site1
For an explanation of all control commands, see section
.
9.
1 Download control software from our Web site at http://www.kramerelectronics.com
905 technical specifications are shown in Table 2:
Table 2: 905 Technical Specifications1
INPUTS:
1 unbalanced stereo audio input on RCA connectors
1 balanced stereo audio input on a 5-pin terminal block connector
OUTPUTS:
1 speaker stereo audio output on a 4-pin terminal block connector
INPUT SENSITIVITY:
8Ω: 320mVpp (unbalanced), 690mVpp (balanced)
4Ω: 220mVpp (unbalanced), 780mVpp (balanced)
OUT
KRAMER: SIMPLE CREATIVE TECHNOLOGY 905 Commands in Protocol 3000
12
9
905 Commands in Protocol 3000
This section describes all commands sent to the 905. For an explanation of
the syntax and use of Protocol 3000, see section U 9.7U.
9.1
14BOperating Commands
Following are the specific commands that the room controller (RC device)
sends to the 905 to operate the external devices.
9.2
15BHelp Commands
Command
Syntax
Response
Protocol handshaking
#CR
~OKCRLF
905 Commands in Protocol 3000
13
'>' = Connection character between in and out parameters.
OUT = Output number or '*' for all outputs.
9.6
Audio Parameters Commands
Command
Syntax
Response
Set simple audio
volume
VOLUME VOLUME
Short form: VOL VOLUME
VOLUME VOLUME RESULT
Increase/decrease
simple audio volume
VOLUME +/-
Short form: VOL +/-
VOLUME +/- RESULT
Read simple audio
level
VOLUME?
Short form: VOL?
VOLUME VOLUME
Advanced commands for controlling each
KRAMER: SIMPLE CREATIVE TECHNOLOGY 905 Commands in Protocol 3000
14
9.7
Protocol 3000 Syntax
Protocol 3000 is used to control the 905 via an RS-232 connection using a
PC, touch screen, other serial controller or RC type controller.
9.7.1 Host Message Format
Start
Address (optional)
Body
Delimiter
#
Destination_id@
Message
CR
9.7.1.1 Simple Command
Command string with only one command without addressing:
Start
Body
Delimiter
#
Command SP Parameter_1,Parame
905 Commands in Protocol 3000 15
Note: A string can contain more than one command. Commands are
separated by a pipe ( '|' ) character.
Message starting character
'#' – For host command/query
'~' – For machine response
Device address (Optional, for K-NET)
K-NET Device ID followed by '@'
Query sign
'?' follows some commands to define a query request.
All outputs sign
'*' defines all outputs.
Message closing character
CR – For host messages; carriage r
KRAMER: SIMPLE CREATIVE TECHNOLOGY 905 Commands in Protocol 3000
16
Commands in the string do not execute until the closing character is
entered.
A separate response is sent for every command in the chain.
9.7.6 Maximum String Length
64 characters
WHO IS PROTECTED?
WHAT IS COVERED AND WHAT IS NOT COVERED
WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR
HOW YOU CAN GET WARRANTY SERVICE
LIMITATION OF IMPLIED WARRANTIES
EXCLUSION OF DAMAGES
CAUTION!
Kramer Electronics (hereafter
) warrants this product free from defects in material and workmanship under the
following terms.
Kramer
HOW LONG IS THE WARRANTY
Labor and parts are warranted for seven years from the date of the first cus