Kramer 905 Operation & User’s Manual

Text of Kramer 905 Operation & User’s Manual

Kramer 905 Your 905 Power Amplifier

3 5 Installing the 905 in a Rack 6 6 Connecting the 905 Power Amplifier 7 6.1 Connecting the 905 via RS-232 8 7 Operating the 905 Power Amplifier 8 7.1 Using the Front Panel Buttons 8 7.1.1 Adjusting the Volume 8 7.1.2 Muting the Output 8 7.1.3 Mixing the Input Signals 9 7.2 Using the Audio Control Program 9 7.3 Using Serial Commands 10 8 Tech

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Contents ii Figures Figure 1: 905 Power Amplifier 4 Figure 2: Connecting the 905 Power Amplifier 7 Figure 3: Audio Control Window 10 Tables Table 1: 905 Power Amplifier Functions 5 Table 2: 905 Technical Specifications 11 Table 3: Communication Parameters 11

Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been

providing a world of unique, creative, and affordable solutions to the vast range of problems that confront the video, audio, presentation, and broadcasting professional on a daily basis. In recent years, we have redesigned and upgraded most of our line, making the best even better! Our 1,000-plus different models now appear in 11 groups1 Thank you for purc
KRAMER: SIMPLE CREATIVE TECHNOLOGY Contents 2 2.1 Quick Start This quick start chart summarizes the basic setup and operation steps.

The Kramer 905 is a high-performance power amplifier for line-level stereo

audio signals. It accepts either a stereo audio signal on an RCA connector or a balanced stereo audio signal on a terminal block connector. It delivers a speaker output of 80 watts RMS per channel into a 4Ω load on a 10A 4-pin terminal block connector. The 905 features: • Two input selector buttons • Two buttons for adjusting the volume and a mute button
Your 905 Power Amplifier 5 Table 1: 905 Power Amplifier Functions # Feature Function 1 INPUT SELECTOR 1,2 Buttons Press to select the input audio source 1 (unbalanced) or 2 (balanced) 2 Volume ↑↓ Buttons Press to increase or decrease the output volume 3 MUTE Button Press to turn off or turn on the audio output. The button illuminates when the audio output is disabled 4 INPUT 1 Left and Right RCA Connectors Connect to the unbalanced stereo audio source
KRAMER: SIMPLE CREATIVE TECHNOLOGY Installing the 905 in a Rack 6 5 Installing the 905 in a Rack This section provides instructions for rack mounting the 1U unit.

Connecting the 905 Power Amplifier

7 6 Connecting the 905 Power Amplifier To connect the 905, as illustrated in the example in Figure 2, do the following: 1. Connect an unbalanced stereo audio source (for example, the unbalanced output of the DVD 1 player) to the L and R INPUT 1 RCA connectors. 2. Connect a balanced stereo audio source (for example, the balanced stereo audio output of the DVD 2 player) to the INPUT 2 terminal block connector. 3. Connect th
KRAMER: SIMPLE CREATIVE TECHNOLOGY Operating the 905 Power Amplifier 8 6.1 Connecting the 905 via RS-232 You can connect to the 905 via an RS-232 connection using, for example, a PC. Note that a null-modem adapter/connection is not required. To connect to the 905 via RS-232: • Connect the RS-232 9-pin D-sub rear panel port on the 905 unit via a 9-wire straight cable (only pin 2 to pin 2, pin 3 to pin 3, and pin 5 to pin 5 need to be connected) to the R

Kramer 905 Operating the 905 Power Amplifier

9 7.1.3 Mixing the Input Signals You can mix the input signals using the two INPUT SELECTOR buttons. To mix the signals, do the following: 1. Press the selected input twice. The other input button illuminates and both buttons enter the mixing mode. 2. Press and hold the selected input button for 2 or 3 seconds until it blinks. 3. Press the up and down arrows to adjust the mixing rate between the inputs. To exit the mixing
KRAMER: SIMPLE CREATIVE TECHNOLOGY Operating the 905 Power Amplifier 10 Figure 3: Audio Control Window 7.3 Using Serial Commands To operate your device using serial commands, you need to install Kramer's control software that can be downloaded from the Kramer Electronics Web site1 For an explanation of all control commands, see section . 9. 1 Download control software from our Web site at http://www.kramerelectronics.com

905 technical specifications are shown in Table 2:

Table 2: 905 Technical Specifications1 INPUTS: 1 unbalanced stereo audio input on RCA connectors 1 balanced stereo audio input on a 5-pin terminal block connector OUTPUTS: 1 speaker stereo audio output on a 4-pin terminal block connector INPUT SENSITIVITY: 8Ω: 320mVpp (unbalanced), 690mVpp (balanced) 4Ω: 220mVpp (unbalanced), 780mVpp (balanced) OUT
KRAMER: SIMPLE CREATIVE TECHNOLOGY 905 Commands in Protocol 3000 12 9 905 Commands in Protocol 3000 This section describes all commands sent to the 905. For an explanation of the syntax and use of Protocol 3000, see section U 9.7U. 9.1 14BOperating Commands Following are the specific commands that the room controller (RC device) sends to the 905 to operate the external devices. 9.2 15BHelp Commands Command Syntax Response Protocol handshaking #CR ~OKCRLF

905 Commands in Protocol 3000

13 '>' = Connection character between in and out parameters. OUT = Output number or '*' for all outputs. 9.6 Audio Parameters Commands Command Syntax Response Set simple audio volume VOLUME VOLUME Short form: VOL VOLUME VOLUME VOLUME RESULT Increase/decrease simple audio volume VOLUME +/- Short form: VOL +/- VOLUME +/- RESULT Read simple audio level VOLUME? Short form: VOL? VOLUME VOLUME Advanced commands for controlling each
KRAMER: SIMPLE CREATIVE TECHNOLOGY 905 Commands in Protocol 3000 14 9.7 Protocol 3000 Syntax Protocol 3000 is used to control the 905 via an RS-232 connection using a PC, touch screen, other serial controller or RC type controller. 9.7.1 Host Message Format Start Address (optional) Body Delimiter # Destination_id@ Message CR 9.7.1.1 Simple Command Command string with only one command without addressing: Start Body Delimiter # Command SP Parameter_1,Parame
905 Commands in Protocol 3000 15 Note: A string can contain more than one command. Commands are separated by a pipe ( '|' ) character. Message starting character '#' – For host command/query '~' – For machine response Device address (Optional, for K-NET) K-NET Device ID followed by '@' Query sign '?' follows some commands to define a query request. All outputs sign '*' defines all outputs. Message closing character CR – For host messages; carriage r
KRAMER: SIMPLE CREATIVE TECHNOLOGY 905 Commands in Protocol 3000 16 Commands in the string do not execute until the closing character is entered. A separate response is sent for every command in the chain. 9.7.6 Maximum String Length 64 characters

WHO IS PROTECTED?

WHAT IS COVERED AND WHAT IS NOT COVERED WHAT WE WILL PAY FOR AND WHAT WE WILL NOT PAY FOR HOW YOU CAN GET WARRANTY SERVICE LIMITATION OF IMPLIED WARRANTIES EXCLUSION OF DAMAGES CAUTION! Kramer Electronics (hereafter ) warrants this product free from defects in material and workmanship under the following terms. Kramer HOW LONG IS THE WARRANTY Labor and parts are warranted for seven years from the date of the first cus

Kramer Amplifier Owners Instructions: