Teledyne 316RA Instruction Manual

Text of Teledyne 316RA Instruction Manual

TELEDYNE ANALYTICAL INSTRUMENTS

MODEL 316RA/RB/RAD/RBD TRACE OXYGEN ANALYZER INSTRUCTION MANUAL TAI Sales Order Number: Model Number: Serial Number: Micro-Fuel Cell Class: Output Signal: Ranges: X1: ppm Oxygen X10: ppm Oxygen X100: ppm Oxygen X1000: ppm Oxygen Alarm Set Point #1: Alarm Set Point #2: P/N M34905.4 M38546.4 ECO# 95-348 06/06/95
TELEDYNE ANALYTICAL INSTRUMENTS Copyright © 1993 Teledyne Analytical Instruments All Rights Reserved. No part of this manual may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any other language or com- puter language in whole or in part, in any form or by any means, whether it be elec- tronic, mechanical, magnetic, optical, manual, or otherwise, without the prior written consent of Teledyne Analytical Instrument
TELEDYNE ANALYTICAL INSTRUMENTS Table of Contents Introduction ............................................................................... 1 Features .............................................................................. 2 Operational Theory ................................................................... 3 Micro-Fuel Cell Sensor........................................................ 3 Sampling System .......................................
TELEDYNE ANALYTICAL INSTRUMENTS 1 Trace Oxygen Analyzer Model 316RA/RB/RAD/RBD Introduction The Teledyne Analytical Instruments (TAI) Series 316 Trace Oxygen Analyzer uses a unique Micro-Fuel Cell to measure the concentration of oxygen in a gas stream. The cell has an absolute zero and produces a linear output from the low parts per million (ppm) level through 21% (210,000 ppm) oxygen. When coupled with a “state of the art” two stage amplifier system t
TELEDYNE ANALYTICAL INSTRUMENTS 2 Model 316RA/RB/RAD/RBD Trace Oxygen Analyzer Features Maintenance-Free Sensor. Teledyne’s Micro-Fuel Cell oxygen sensor is a sealed electrochemical transducer with no electrolyte to change or electrodes to clean. When the cell reaches the end of its useful life (6 months minimum), simply remove and replace. Temperature Compensation. The Series 316 includes a built-in temperature compensation circuit for greater accuracy.
TELEDYNE ANALYTICAL INSTRUMENTS 3 Trace Oxygen Analyzer Model 316RA/RB/RAD/RBD Operational Theory Micro-Fuel Cell Sensor The Series 316 uses a Micro-Fuel Cell for the measurement of trace oxygen. This Micro-Fuel Cell is an electrochemical transducer whose features include: • Specificity for oxygen • Long interval between calibration • Long life • Low maintenance • Disposable configuration The transducer functions as a fuel cell; in this instance,

Teledyne Analytical Instruments Owners Instructions: