Leviton DMX-512 Operation & User’s Manual
Read Online
Read the Leviton DMX-512 Operation & User’s Manual online using the built-in PDF viewer.
Key Pages of Document
User Guide Leviton Remembrance Control Stations REMEMBRANCE DMX-512 AND ANALOG CONTROL STATIONS USER GUIDE Copyright® 2004 Leviton Manufacturing Co., Inc. DI-00X-RMB81-00A ...
User Guide Leviton Remembrance Control Stations Table of Contents System Overview ..................................................................................................................... 5 Remember When … ....................................................................................................................................5 Welcome Back to Simplicity. ................................................................. ...
User Guide Leviton Remembrance Control Stations Sample System Configurations ............................................................................................ 18 Multi-Purpose Room With A/V Control Booth.............................................................................................18 Small Church (All Analog Stations) ...................................................................................................... ...
User Guide Leviton Remembrance Control Stations SYSTEM OVERVIEW Remember When … Remember when anyone could add a house light channel or a submaster to a lighting control system by wiring a slide pot to a diode and attaching it to which ever dimmers they wanted to control? Remember when control stations could be set up as independents, or group them with masters all without having to have a lap top, memorize DMX-512, know Windows 95 or battle ...
User Guide Leviton Remembrance Control Stations • Standard NEMA Gang Boxes • Imagination What is not needed? • A PC, DOS, Windows. Configuration files, disks or download cables. Station thumbwheel settings, A central processing cabinet. Lots of patience. ...
User Guide Leviton Remembrance Control Stations CONTROL STATION OPERATION Play Mode Action Result • Press the ON/OFF (Panic) button to The LED will light, indicating the activate the station. station is active. An Entry or Panic station will automatically activate a scene. • Adjust Master Fader if applicable. The Master Fader Proportionally controls all channel levels. • Adjust Channel Fader if applicable. Channel Faders may control one ...
User Guide Leviton Remembrance Control Stations • Turn off all control stations. This insures only console levels will be recorded. • Bring up the desired scene or look on This is the scene that will be the main console recorded. • Go to the DMX control station. This gets the station ready to be put Slide Master Fader all the way up to full. in record mode. Slide all the channel faders down to out. • Push and hold the ON/OFF button whe ...
User Guide Leviton Remembrance Control Stations DMX Channel Mode (for DMX control stations only) Action Result • Install Jumper JP1 on ANA2DMX PCB. This puts processor in channel mode. • Dial up the starting address on This selects the DMX start address for rotary Switches SW1, SW2, & SW3 fader A1. • For fader channel single pattern Faders 1-6 will respond to DMX channels operation, remove JP4. 1-6. (assuming start address – 001). • ...
User Guide Leviton Remembrance Control Stations COMPONENT FUNCTIONS Take control PCB The take control PCB has a single switch for ON/OFF operation. The take control PCB requires +12 to +16 Volts DC 25mA connected across +V and common to operate. The PCB provides a regulated +10.6 VDC source when the ON/OFF switch is activated (turned on) and O Volts when off. Pressing the ON/OFF switch sends a +10VDC pulse out the T/C terminal on TB1 and dow ...
User Guide Leviton Remembrance Control Stations SYSTEM DESIGN CONSIDERATIONS Place HHR or DMX-512 IN jacks near DMX stations Place a Hand Held Remote Jack from the control console or a DMX-512 IN Jack where the console could be plugged in near any station that will be used to snapshot scenes on a frequent basis. This way scenes can be activated from the console in the same place they are to be recorded. Power Supply Requirements DMX Station C ...
User Guide Leviton Remembrance Control Stations Current Calculation Examples: 3 Grouped Stations Current demand calculation for qty 3, 6 channel stations connected in a group: T/C connected between stations, therefore only one station can be on at a time. +V Amps = 50mA (station 1) + 5mA (station 2) + 5mA (Station 3) = 60mA 3 Independent Stations Current demand calculation for qty 3, 6 channel stations connected independently; T/C not used. A ...
User Guide Leviton Remembrance Control Stations SYSTEM CABLE REQUIREMENTS All DMX-512 lines ............................................. Belden # 9829 cable All Analog lines ................................................. Alpha # 1898/x C cable 1000 feet MAX!! Where x = the # of conductors All AC1 and AC2 lines ....................................... 18 gauge 600V wire Cross Referenced Analog Compatible Cable Types: Belden 8489 (4 conducto ...
User Guide Leviton Remembrance Control Stations ELIMINATE GROUND LOOPS What is ground? This control system, like most other control systems requires a common reference for the electronics to function properly. This reference is typically denoted as Common or Ground. Control voltages are measured with respect to this ground reference, just like the height of a person would normally be measured with respect to the ground they are standing on. ...
User Guide Leviton Remembrance Control Stations ADVANCED TOPICS Use of blocking (steering) Diodes. What is a Diode? A diode is a one-way valve. It allows current to flow in a forward direction, but not in a reverse direction. The input is the anode, or un-banded end of the part; and the output is the cathode, or banded end of the part. When the input (anode) is at a voltage potential higher than the output (cathode), current will pass from ...
User Guide Leviton Remembrance Control Stations ADDENDUM Concerning New REMEMBRANCE Preset Stations: Wiring Details 8 Preset Station: Refer to 8 Channel Analog Station Wiring Diagram and Colortran (8-1028, 8-1148, 8-1188) Colortran Production Drawings for connection details of this Preset Station in your specific system. 4 Preset Station: Refer to Colortan Production Drawings for connection (8-1024, 8-1144) details of this Preset Station in y ...
User Guide Leviton Remembrance Control Stations Preset Station DMX-512 Snapshot Record Procedure 1. JP3 must be installed on this station. 2. Activate DMX-512 scene from control console or DMX-512 portion of control station. On i series e racks, or i series e Quad racks, a relative fade time for the preset may be assigned by setting DMX channels 511 and 512 to the same control level as follows: Full = 90 seconds 90% = 9 seconds 80% = 8 second ...
User Guide Leviton Remembrance Control Stations SAMPLE SYSTEM CONFIGURATIONS MASTER ON / OFF Remembrance MASTER ON / OFF Remembrance COM +V T/C VOUT A1 A2 A3 COM +V T/C VOUT A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 10VACX 10VACY REC LOCK DMX OUT+ DMX OUT- DGND OUT DMX IN+ DMX IN- DGND IN A MASTER ON / OFF Remembrance COM +V T/C VOUT A1 A2 A3 B ROOM 1 3 CHANNEL ANALOG CAT. NO. 003-RMB81-3 COMBINE ROOMS MASTER ON / OFF Remembrance COM +V T/C VOUT ...
User Guide Leviton Remembrance Control Stations COM +V T/C VOUT A1 A2 COM +V T/C VOUT A1 A2 A3 A4 A5 A6 A7 A8 COM +V T/C VOUT A1 A2 COM +V T/C VOUT HOUSE DOWNLIGHTS VESTIBULE NSI CAT. NO. N2408 VESTIBULE ENTRY STATION CAT. NO. 010-RMB81-21 HOUSE RIGHT TWO CHANNEL ANALOG STATION CAT. NO. 002-RMB81-2 HOUSE LEFT TWO CHANNEL ANALOG STATION CAT. NO. 002-RMB81-2 PODIUM SANCTUARY WASH SOLOIST CHOIR BABTISMAL HOUSE CHANDELIER HOUSE DOWNLIGHTS VESTIBU ...
User Guide Leviton Remembrance Control Stations MASTER ON / OFF Remembrance MASTER ON / OFF Remembrance COM +V T/C VOUT A1 A2 A3 COM +V T/C VOUT A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 COM +V T/C VOUT 10VACX 10VACY REC LOCK DMX OUT+ DMX OUT- DGND OUT DMX IN+ DMX IN- DGND IN A MASTER ON / OFF Remembrance COM +V T/C VOUT A1 A2 A3 B MASTER ON / OFF Remembrance COM +V T/C VOUT A1 A2 A3 3 CHANNEL ANALOG STATIONS CAT. NO. 003-RMB81-3 HOUSELIGHT STAT ...
Related Devices for Leviton DMX-512:
LEVITON UPB™ THREE-PHASE REPEATER Cat. No. 39A00-3 Installation Instructions and User’s Guide INSTALLATION ENGLISH DI-021-HL393-05AAR2243 (39I00-3) DESCRIPT Instruction guidebook for the Leviton UPB 39A00-3 Repeater. It provides information on installation and troubleshooting, shutdown procedures, setup guidelines, technical assistance.
WARNINGS AND CAUTIONS: •� ON/OFF�LED�for�remote�load�status. •� To�be�installed�and/or�used�in�accordance�with�appropriate�e Device instruction guide for the Leviton VRCS4-MR Matrix Switcher. This manual provides guidance on operating instructions, safety guidelines, dimensions and layout.
INSTALLATION English Single Pole Low Voltage Switch Cat. No. 56021 Rated: 3A-24V AC-DC only WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE Device instruction guide for the Leviton DECORA PLUS 56021 Switch. The manual details dimensions and layout, setup instructions, warranty information, technical troubleshooting.
User Guide MLC 16 MOTORIZED LIGHTING CONTROLLER Software revision 2.01 and above Device Group 1 2 Pattern Show Scene 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Solo Add Official product manual for the Leviton MLC16 Software. The documentation guides users through setup and system configuration, operational guidelines, service procedures, network setup.
R User Guide Network Protocol Converter Software Revision 3.10 and above Service manual for the Leviton NPC DHV Software. This guide describes user settings, network configuration, installation guides, menu navigation.
• Installs into any single gang device back-box. • Supports Multi-gang installations. • Requires Decora® faceplate, sold separately WARNINGS • TO AVO Installation instructions for the Leviton Lumina ZS10S Switch. It contains information on connectivity options, power requirements, product safety, usage tips.
TOPAZ 96™ DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29133-1A) © Copyright March 2002 Leviton Manufacturing Co., Inc. Contractor: Ple Instructions for safe usage of the Leviton Topaz 96 Dimmer. The manual highlights interface navigation, safety guidelines, detailing setup, troubleshooting tips.
PRODUCT DATA ODS15-ID Leviton Mfg. Co., Inc. Lighting & Energy Solutions 201 N. Service Rd. Melville, NY 11747-3138 Tech Line: 1-800-824-3005 Fax: 1-800-832-9 Practical operating guide for the Leviton Decora ODS15-ID Kitchen Appliances. This guide presents instructions on setup tips, performance details, support details.
Software: Frequently Requested PDF Instructions
Dell DR4000 Systems Getting Started With Your System Začínáme se systémem Guide de mise en route Handbuch zum Einstieg mit dem System Τα πρώτα βήμ User guide for the Dell DR4000 Server. The manual provides information on backup procedures, hardware setup, software updates, operational procedures.
Xerox Document Services Platform Series DocuTech 61xx Operator Guide 701P38838 DocuSP version 3.6 August, 2002 Official product manual for the Xerox DocuTech 6135 Printer. The document elaborates on device functions and product handling, operational guidelines, firmware installation.
EPSON Stylus PHOTO RX600/610 , RX620/630 Scanner • Printer • Copier SERVICE MANUAL SEOT03006 Download Service Manual And Resetter Printer at http://printer1 Essential instructions for the Epson Stylus Photo RX600 Inkjet printer. The manual outlines system configuration and system parameters, usage procedures, operational guidelines, service instructions.