2004 Product Data 1

General Description Thank you very much for your special patronage of LG air-conditioners. A high-grade, high-quality, advanced individual air-conditioning system that is able to respond to expanding, more sophisticated housing environment needs. LG Electronics Inc., which has been a top air conditioner maker for the three consecutive years, has developed "MPS(Multi Power System) Variable Multi Split" system that can efficiently cont ...

2004 Product Data 3

LG Airconditioners Product Data TABLE OF CONTENTS Table of contents Page Part 1 Features...............................................................................................7 Part 2 MPS Variable Multi-Split system (R410A).......................................11 ...

MPS Variable Multi Split System(50Hz, R410A)

Features & Benefit MPS(Multi Power System) Variable Control : (Except A2UC146FA0,A2UH146FA0) Big Energy Saving with MPS Variable Control • Basic Principle of MPS Variable Control MPS control provides comfortable and convenient environment as there are two compressors with 60&40% load sharing with on compressor of small capacity always working to maintain the set temperature conditions & meanwhile other compr ...

2004 Product Data 7

Features & Benefit 90(Min) 0 100 200 300 400 500 (ppm) 60 30 Nano Filter + + + + + + + + + + + + + + + + Normal Filter Air Purifying System - It not only removes microscopic contaminants & dust, but it also removes house mites, pollen, and pet fur to help pre- vent allergic diseases like asthma.It provides odor free, dust free and allergy free air. • Effect of carbon Nano Ball Deodorizing efficieny: 8~10times compared to conventio ...

MPS Variable Multi Split System(50Hz, R410A)

Features & Benefit Vertical Temperature Difference Horizontal Temperature Difference Improved value of the 3-Dimensional Cooling Time Reaching Temperature Thinnest Turbo Fan 129 mm ‘Fast & Even Widely’ Normal ‘Speedy & Powerful’ Jet Cool + ‘Indirectly & Softly’ Sleep Mode Ultra-Slim design(Depth 129mm) 3-Dimensional Cooling System New Cube 3-Dimension cooling system of ART COOL has Indirect Coolin ...

2004 Product Data 9

Features & Benefit Environment Friendly Refrigerant : - LG Air conditioners uses environment friendly refrigerant. Which don't do any harm to the environment. Jet Cool: - In this mode very quick and fast cooling is done. The unit will continue to supply high velocity air for 30 min- utes, untill the room temperature reaches 18°C. After 30 minutes, unit will supply air at the set fan speed whether indoor temperature has reached 18° ...

2004 Product Data 11

Part 2 MPS Variable Multi-Split System R410A, Cooling Only/Heat Pump AMNC076LQL0 AMNC096AP*1 AMNC096LQL0 AMNC126AP*1 AMNC126LRL0 AMNC186LTL0 AMNC246LTL0 AMNH076LQL0 AMNH096AP*1 AMNH096LQL0 AMNH126AP*1 AMNH126LRL0 AMNH186LTL0 AMNH246LTL0 A2UC146FA0 A2UC186FA0 A3UC216FA0 A4UC306FA0 A2UH146FA0 A2UH186FA0 A3UH216FA0 A4UH306FA0 1. Power Supply ............................................................................... ...

MPS Variable Multi Split System(50Hz, R410A)

1. Power Supply Type Outdoor Unit Power Supply Cooling Only 1Ø, 220~240V, 50Hz Heat Pump Note : Power Supply Intake ; Outdoor Unit Only External wiring procedure - The power supply is needed only to the outdoor unit. The power supply to the indoor unit Is conducted through the transmission wiring. Therefore, the power supply can be given at just one place. It will contribute to simplify the work procedure an ...

2004 Product Data 13

2. Model Number Nomenclature 2.1 Indoor Units 2.2 Outdoor Units AMN H 6 07 Q L L 0 Chassis Name Serial Number Combination of Functions ART COOL Type Front Panel Color L : Wall Mounted A : ART COOL B : Blue, D : Wood, M : Metal L : Nano Plasma Indoor Unit Type Electrical Ratings 6: 1ø, 220~240V, 50Hz Nominal Cooling Capacity in Btu/h Ex) 7,000 Btu/h © ‘07’ , 18,000 Btu/h © ‘18’ Model Type C: Cooling Only H: Heat Pump Mul ...

MPS Variable Multi Split System(50Hz, R410A)

3. Outline of System The system has number of indoor units attached to an outdoor unit which saves energy while in operation. This system can be installed in small space and cooling can be controlled in each room individually. 3.1 Example of System [A4UH306FA0] 3.2 Combination of Indoor and Outdoor Unit Indoor Units Capacity Model Type Wall Mounted ART COOL Index kW Btu/h Outdoor Unit A2UC146FA0 A2UH146FA0 A2 ...

2004 Product Data 15

3. Outline of System 3.3 External Appearance of Indoor Units Wall Mounted AMNC076LQL0 AMNH076LQL0 AMNC096LQL0 AMNH096LQL0 AMNC126LRL0 AMNH126LRL0 AMNC186LTL0 AMNH186LTL0 AMNC246LTL0 AMNH246LTL0 ART COOL AMNC096AP*1 AMNH096AP*1 AMNC126AP*1 AMNH126AP*1 '* : Front Panel Color B : Blue D : Wood M : Metal ...

MPS Variable Multi Split System(50Hz, R410A)

4. List of Functions Model Features Airflow Direction Control(Left & Right) Manual Manual Manual Manual Airflow Direction Control(Up & Down) Automatic Automatic Automatic Automatic Airflow Outlet 1 3 1 3 Airflow Steps(Fan / Cool / Heat) 3/4/3 3/4/3 3/4/3 3/4/3 Auto Changeover(Operation) - - - - Auto Cleaning - O - O Auto Restart Operation O O O O Central Control Accessory Accessory Accessory Accessory CHAOS W ...

2004 Product Data 17

5. Specifications 1764(2051) 2267(2638) 3024(3515 4536(5275) 5795(6740 7000 9000 12000 18000 23000 - - - - - - - - - - 5.5(194) 6.0.(212) 9.0(318) 13(459) 14(495) 18~30 / - 18~30 / - 18~30 / - 18~30 / - 18~30 / - 8.4 8.4 14.4 23 28 IC-8415LG62A IC-8415LG62A IC-8420LG48A AMR-023E2 AMR-023E5 4 4 4 4 6 25 25 37 34 63 0.11 0.11 0.16 0.15 0.28 0.9 / 400 0.9 / 400 0.9 / 400 2.0 / 370 2.0 / 370 Cross Flow Fan Cross Flow Fan Cross Flow Fan ...

MPS Variable Multi Split System(50Hz, R410A)

5. Specifications Heat Pump Nominal Cooling Capacity # kcal/hr(W) Btu/hr Nominal Heating Capacity # kcal/hr(W) Btu/hr Air Circulation H/M/L CMM(CFM) Setting temperature range °C Fan motor Output W Model No. of Poles Input W Running Current A Capacitor µF/Vac Fan Type No. Used / Diameter EA/inch(mm) Fan RPM Cooling(H/M/L) rpm Heating(H/M/L) rpm Noise Level(Sound Press,1m) H/M/L dBA Temperature controller Coi ...

2004 Product Data 19

5. Specifications Notes: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB - Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB - Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB - Interconnecting Piping Length 7.5m - Interconnecting Piping Length 7.5 m - Level Difference of Zero. - Level D ...