Omron JX - 2 Manual 

File Specifications

Brand: Omron
Category: Inverter
Model: JX - 2 (Manual ), pryOga7ZWsRB6
File Type: PDF
File Size: —
Pages: 14 pages

Download PDF

Download Omron JX - 2 Manual (14 pages)

Read Online:

Read the Omron JX - 2 Manual  online using the built-in PDF viewer.

Key Pages of Document

Compact and complete

JX INVERTER » Cost and eco-friendly Communications built-in » Quality & reliability you can depend on » ...

The smallest gets integrated...

Omron fully understands your needs, which is why we put quality and reliability first. And we keep listening, so our products come with new features and functionality that save you time and money. With the RFI filter built-in, and the communications integrated as standard, the JX provides a compact and complete solution to ...

No additional devices required

Even advanced functionality such as PID control is standard with the JX inverter making it a convenient solution for applications such as pumps & fans where pressure, flow and other processes need controlling. Automatic energy saving The Inverter always adopts the optimum energy ...

Compact & Complete

• V/f controlled inverter • Side by side mounting • Built-in EMC filter • Built-in RS-485 Modbus • Overload detection function (150% during 60s) • PID • Micro-surge voltage suppression • Automatic energy saving • Emergency shut-off • Second motor setting • Auto carrier-frequency reduction • ...

200 V class

400 V class Specifications Single-phase: JX@ AB002 AB004 AB007 AB015 AB022 - - - Three-phase: JX@ A2002 A2004 A2007 A2015 A2022 A2037 A2055 A2075 Motor kW1 1. Based on a standard 3-Phase standard motor. Applicable motor capacity 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 Output characteristics Inverter capacity kVA 200 V 0.4 0.9 1.3 ...

Phase-to-phase sinusoidal modulation PWM (V/f)

Output frequency range 0.5..400 Hz Frequency precision Digital set value: ±0.01% of the max. frequency Analogue set value: ±0.4% of the max. frequency (25 ±10 ºC) Resolution of freque ...

IP 20 type 0.2 to 7.5 kW

Rasmi footprint Filters Filter only needed by the 1-phase 200V or 3-phase 400V to comply with C1 EMC class. Dimensions Voltage class Max. applicable motor output kW Inverter model JX@ Figure Dimensions in mm W1 H1 W H D t1 D1 Weight Single-phase 200 V 0.2 AB002 1 67 143 80 155 95.5 2.6 13 0.8 0.4 AB004 1 109.5 27 0.9 0.75 AB007 ...

Input AC Reactor

DC Reactor Output AC Reactor Chokes Voltage Reference Dimensions Weight Kg A B2 C2 D E F 200V AX-RAI02800080-DE 120 70 120 80 52 5.5 1.78 AX-RAI00880175-DE 120 80 120 80 62 5.5 2.35 AX-RAI00350335-DE 180 85 190 140 55 6 5.5 400V AX-RAI07700042-DE 120 70 120 80 52 5.5 1.78 AX-RAI03500090-DE 120 80 120 80 62 5.5 2.35 AX- ...

Terminal Block Specifications

Installation Terminal Name Function (signal level) R/L1, S/L2, T/N/L3 Main circuit power supply input Used to connect line power to the drive. Drives with single-phase 200 V input power use only terminals R/L1 and N (T/L3), terminal S/L2 is not available for these units U/T1, V/T2, W/T3 Inverter outpu ...

Side by side mounting

Type No. Signal name Function Signal level Digital input signals PCS Input power supply External power supply terminal for input signal (input) ...At sink logic Internal power supply output terminal for input signal (output) ...At source logic 24 VDC ±10% P24 Internal 24 VDC 24 VDC internal power ...