Omron MS4800E Operation Manual
Text of the manual
Cat. No. F04E-EN-01
Safety Light Curtain Type 4
MS4800E
OPERATION MANUAL
Cat. No. F04E-EN-01
MS4800E Safety Light Curtain Type 4
OPERATION MANUAL
Safety Light Curtain Type 4
Installation and Operating Manual
January 2008
Omron Europe B.V.
Wegalaan 67-69
NL-2132 JD, Hoofddorp
Pays-Bas
Tel.: +31 (0) 23 568 13 00
Fax: +31 (0) 23 568 13 88
www.industrial.omron.eu
OMRON products are manufactured for use according to proper procedures
by a qualified operator and only for the purposes described in this manual.
The following conventions are used to indicate and classify precautions in this
manual. Always heed the information provided with them. Failure to heed pre-
cautions can result in injury to people or damage to property.
!DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or
serious injury.
!WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
!Caution
Indicates a potentially hazardous situation which, if not avoided, may result in minor or
moderate injury, or property damage.
OMRON Product References
All OMRON products are capitalized in this manual. The word “Unit” is also
capitalized when it refers to an OMRON product, regardless of whether or not
it appears in the proper name of the product.
Visual Aids
The following headings appear in the left column of the manual to help you
locate different types of information.
Note Indicates information of particular interest for efficient and convenient opera-
tion of the product.
1,2,3...
1.
Indicates lists of one sort or another, such as procedures, checklists, etc.
© OMRON, 2008
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or
by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of
OMRON.
No patent liability is assumed with respect to the use of the information contained herein. Moreover, because OMRON is con-
stantly striving to improve its high-quality products, the information contained in this manual is subject to change without
notice. Every precaution has been taken in the preparation of this manual. Nevertheless, OMRON assumes no responsibility
for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in
this publication.
TABLE OF CONTENTS
vii
PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xiii
1
Precautions on Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xiii
2
Alert Statements in this manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xiii
3
Precautions for Safe Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xvii
4
Precautions for Correct Use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
xviii
SECTION 1
Important Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . .
1
SECTION 2
Product features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
SECTION 3
System Components and Indicators . . . . . . . . . . . . . . . . . . .
4
SECTION 4
System Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
4-1
Operating States. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
4-2
Operating Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
4-3
MS4800FS Cascaded Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
SECTION 5
Detection Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
5-1
Fixed Blanking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9
5-2
Floating Blanking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
5-3
Fixed Blanking with Floating Blanking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
5-4
Optical Synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15
SECTION 6
Diagnostic and Test Features. . . . . . . . . . . . . . . . . . . . . . . . .
17
6-1
Individual Beam Indicators (IBI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17
6-2
External Device Monitoring (EDM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17
6-3
Machine test signal (MTS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17
6-4
Range selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17
6-5
Start/Restart Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
Using selector switches to set features. . . . . . . . . . . . . . . . . .
19
7-1
Access to the selector switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
19
7-2
Operating mode selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
7-3
Selecting and programming Fixed Blanking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
7-4
Selecting and programming Floating Blanking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
7-5
Selecting External Device Monitoring (EDM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
7-6
Selecting Machine Test Signal (MTS). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
7-7
Selecting Scan Codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
SECTION 8
Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
8-1
Safety Outputs (OSSDs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
8-2
Auxiliary Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
SECTION 9
Safe Mounting Distances . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
9-1
Safety distance for safeguarding danger points. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
25
9-2
Safety distance for safeguarding danger areas. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
9-3
Safety distance and beam heights in access guarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
28
SECTION 10
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29
10-1 Reflective Surface Interference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
29
10-2 Cross Talk Mitigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
30
10-3 General Mounting Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31
SECTION 11
Connection to the Machine Control Circuit. . . . . . . . . . . . .
35
11-1 Interconnect cables for cascaded MS4800FS system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
35
11-2 Connection to two forcibly guided relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
36
11-3 Connection to a safety relay unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
36
SECTION 12
Muting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37
12-1 Muting Controller RM-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37
SECTION 13
Checkout and test procedure. . . . . . . . . . . . . . . . . . . . . . . . .
39
13-1 Checkout Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
13-2 Test Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
13-3 Using the test object. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
41
SECTION 15
Specifications and additional information . . . . . . . . . . . . . .
43
15-1 System Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
43
15-2 MS4800 system Dimensional Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
46
15-3 MS4800 system data with 14 mm resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
47
15-4 MS4800 system data with 30 mm resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
48
15-5 MS4800FS system Dimensional Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50
15-6 MS4800FS system data with 14 mm resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
51
15-7 MS4800FS system data with 30 mm resolution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
52
15-8 List of models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
55
15-9 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
65
SECTION 16
Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
69
SECTION 17
Diagnostics and Troubleshooting . . . . . . . . . . . . . . . . . . . . .
71
17-1 Transmitter Diagnostic information and troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . .
71
17-2 Receiver Diagnostic Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
71
17-3 Receiver Endcap Indicator Lights. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
71
17-4 Receiver Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
72
17-5 Receiver Error Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
72
SECTION 18
Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
75
18-1 Appendix A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
75
18-2 Appendix B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
76
Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
77
Thank you for purchasing the MS4800 series Safety Light Curtain. This is the instruction manual
describing the use of the MS4800 system.
Important notice
This manual provides installation and operating information on the following models:
Where information is common on all models the term "MS4800 system" will be used. Where informa-
tion is given for a specific model the model number will be used.
Always heed the following points when using the MS4800 system:
1.
Be sure to have MS4800 system handled by a "Responsible Person" who is well aware of and
familiar with the machine to be installed.
2.
The term "Responsible Person" used in this Instruction manual means the person qualified,
authorized and responsible to secure "safety" in each process of the design, installation, oper-
ation, maintenance services and disposition of the machine.
3.
It is assumed that MS4800 system will be used properly according to the installation environ-
ment, performance and function of the machine. Responsible Person should conduct risk
assessment on the machine and determine the suitability of this product before installation.
4.
Read this Manual thoroughly to understand and make good use of the descriptions before
installing and operating the product.
5.
Keep this Manual at the place where the operator can refer to whenever necessary.
Basic
Advanced
Resolution 14 mm, standalone
MS4800S-EB-014
MS4800S-EA-014
Resolution 14 mm, cascadable
MS4800FS-EB-014
MS4800FS-EA-014
Resolution 30 mm, standalone
MS4800S-EB-030
MS4800S-EA-030
Resolution 30 mm, cascadable
MS4800FS-EB-030
MS4800FS-EA-030
Read and understand this document
Please read and understand this document before using the products. Please consult your OMRON
representative if you have any questions or comments.
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship
for a period of one year (or other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING
NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE
PRODUCTS, ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OR THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAM-
AGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PROD-
UCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR
STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on
which liability asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS
REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS
WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO
CONTAMINTAION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to
the combination of products in the customer's application or use of the product.
At the customer's request, OMRON will provide applicable third party certification documents identify-
ing ratings and limitations of use that apply to the products. This information by itself is not sufficient for
a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is
not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that
the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions
or uses not described in this document.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical
equipment, amusement machines, vehicles, and installations subject to separate industry or govern-
ment regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR
PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability
and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the
users must correlate it to actual application requirements. Actual performance is subject to the
OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and
other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when
significant construction changes are made. However, some specifications of the product may be
changed without any notice. When in doubt, special model numbers may be assigned to fix or estab-
lish key specifications for your application on your request. Please consult with your OMRON repre-
sentative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when
tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however,
no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any con-
sequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product.
Please notify us before copying or reproducing this document in any manner, for any other purpose. If
copying or transmitting this document to another, please copy or transmit it in its entirety.
Precautions on Safety
In order to use the MS4800 system safely, the precautions listed in this man-
ual indicated by alert symbols and descriptions must be followed. Failure to
follow all precautions and alerts may result in an unsafe use or operation.
The following indications and symbols are used for the application:
!WARNING This sign indicates a potentially hazardous situation which, if not avoided, will
result in minor or moderate injury, or may result in serious injury or death.
Additionally there may be significant property damage.
2
Alert Statements in this manual
2-1
For users
!WARNING The MS4800 system must be installed, configured, and incorporated into a
machine control system by a sufficiently trained and qualified person. An
unqualified person may not be able to perform these operations properly,
which may cause a person to go undetected, resulting in serious injury.
!WARNING When changes are made to each function using the selector switches, the
administrator must manage the detail of the changes and perform the
changes. Accidental functional setting change may cause failure of human
body detection, resulting in a serious injury.
2-2
For machines
!WARNING Do not use this sensor for machines that cannot be stopped by electrical con-
trol. For example, do not use it for a pressing machine that uses full-rotation
clutch. Otherwise, the machine may not stop before a person reaches the
hazardous part, resulting in serious injury.
!WARNING Do not use the auxiliary output or external indicator output for safety applica-
tions. Human body may not be detected when MS4800 system fails, resulting
in serious injury.
2-3
For installations
!WARNING After unpacking and before installing the MS4800 system please check the
mechanical condition of the system carefully. Do not install a mechanically
damaged product. Return this to your OMRON service for inspection or repair.
Failure to do so may result in serious injury.
!WARNING Do not drop the products. Dropping the products may lead to internal or exter-
nal damage. Please return a MS4800 system that was dropped on the floor to
your OMRON service for inspection or repair. Failure to do so may result in
serious injury.
!WARNING Make sure to test the operation of the MS4800 system after installation to ver-
ify that the MS4800 system operates as intended. Make sure to stop the
machine until the test is complete. Unintended function settings may cause a
person to go undetected, resulting in serious injury.
Alert Statements in this manual
2
!WARNING Make sure to install the MS4800 system at the safe distance from the hazard-
ous part of the equipment. Otherwise, the machine may not stop before a per-
son reaches the hazardous part, resulting in serous injury.
!WARNING Install a protective structure so that the hazardous part of a machine can only
be reached by passing through the sensor's detection zone. Install the sen-
sors so that part of the person is always present in the detection zone when
working in a machine's hazardous areas. If a person is able to step into the
hazardous area of a machine and remain behind the MS4800 system's detec-
tion zone, configure the system with an interlock function that prevents the
machine from being restarted. Failure to do so may result in serious injury.
!WARNING Install the interlock reset switch in a location that provides a clear view of the
entire hazardous area and where it cannot be activated from within the haz-
ardous area.
!WARNING The MS4800 system cannot protect a person from a projectile exiting the haz-
ardous zone. Install protective cover(s) or fence(s).
!WARNING To prevent personnel approach to dangerous part of the machine through a
zone disabled by the fixed blanking function, you must install a protective
structure to cover the whole disabled zone. Failure to do so may cause failure
of human body detection, resulting in a serious injury.
!WARNING You must ensure that a test rod is detected for all detection zones except
where fixed or floating blanking function is used. Failure to do so may cause
failure of human body detection, resulting in a serious injury.
!WARNING Detection capability gets larger if fixed or floating blanking function is used.
You must use the detection capability for fixed and floating blanking functions.
Failure to do so may cause failure of machine stop before reaching the
machine's dangerous part, resulting in a serious injury.
!WARNING The muting and override functions disable the safety functions of the device.
You must ensure safety using other method when these functions are operat-
ing.
!WARNING Install muting sensors so that they can distinguish between the object that is
being allowed to pass through the detection zone and a person. If the muting
function is activated by the detection of a person, it may result in serious
injury.
!WARNING Muting lamps (external indicators) that indicate the state of the muting and
override functions must be installed where they are clearly visible to workers
from all the operating positions.
!WARNING Muting related time must be properly configured for its application by a suffi-
ciently trained and qualified person, and the person must have responsibility
for settings, especially when setting the muting time limit to infinite.
!WARNING Use independent 2 input devices for muting inputs.
!WARNING You must install MS4800 system muting sensor, and physical barrier, and con-
figure time settings for muting so that an operator should not enter hazardous
zone.
Alert Statements in this manual
2
!WARNING Install the switch that activates the override in a location that provides a clear
view of the entire hazardous area and where it cannot be activated from within
the hazardous area. Make sure that nobody is in the hazardous area before
activating the override function.
!WARNING Do not place fluorescent lights within the effective aperture angle of the
receiver, as it may influence the MS4800 system under certain circumstances.
!WARNING Install the sensor system so that it is not affected by any reflective surfaces.
Failure to do so may hinder detection, resulting in serious injury.
!WARNING When using more than 1 set of MS4800 system, install them so that mutual
interference does not occur, such as by configuring series connections or
using physical barriers between adjacent sets.
!WARNING Make sure that the MS4800 system is securely mounted and its cables and
connectors are properly connected.
!WARNING Make sure that foreign objects such as water, oil, or dust do not enter the
inside of the MS4800 system while the cover for the selector switches is open
and tighten the screws of the cover firmly after changing the settings.
!WARNING Do not use the sensor system with mirrors in a retro-reflective configuration.
Doing so may hinder detection. It is possible to use mirrors to "bend" the
detection zone to a 90° angle.
!WARNING Perform an inspection for all MS4800 systems as described in the chapter
"Checkout and test procedure". When using series connections, perform
inspections for every connected MS4800 system.
2-4
For wiring
!WARNING Connect the load between the output and 0V line (PNP output). Connecting
the load between the output and +24 V line will result in a dangerous condi-
tion because operation is reversed to "ON when blocked".
!WARNING Do not short-circuit the output line to the +24 V line. Otherwise, the output is
always ON. Also, the 0 V of the power supply must be grounded so that output
does not turn ON due to grounding of the output line.
!WARNING Configure the system by using the optimal number of safety outputs that sat-
isfy the requirements of the necessary safety category.
!WARNING Do not connect each line of MS4800 system to a DC power supply of more
than 24 VDC+20%. Also, do not connect to an AC power supply. Failure to do
so may result in electric shock.
Alert Statements in this manual
2
!WARNING For the MS4800 system to comply with IEC 61496-1 and UL 508, the DC
power supply unit must satisfy all of thefollowing conditions:
•
Must be within the rated power voltage (24 V DC ± 20%)
•
Must have tolerance against the total rated current of devices if it is
connected to multiple devices
•
Must comply with EMC directives (industrial environment)
•
Double or reinforced insulation must be applied between the primary
and secondary circuits
•
Automatic recovery of overcurrent protection characteristics
•
Output holding time must be 20 ms or longer
•
Must satisfy output characteristic requirements for class 2 circuit or
limited voltage current circuit defined by UL508
•
Must comply with laws and regulations, regarding EMC and electrical
equipment safety, of the country or region where the MS4800 system
is used (Ex: In EU, the power supply must comply with the EMC Di-
rective and the Low Voltage Directive.)
!WARNING Double or reinforced insulation from hazardous voltage must be applied to all
input and output lines. Failure to do so may result in electric shock.
!WARNING Extension of the cable must be within a specified length. If it isn't, safety func-
tion may not work properly, resulting in danger.
2-5
Other
!WARNING To use the MS4800 system in PSDI mode (Re-initiation of cyclic operation by
the protective equipment), you must configure an appropriate circuit between
the MS4800 system and the machine. For details about PSDI, refer to
IEC61496-1, and other relevant standards and regulations.
!WARNING Do not try to disassemble, repair, or modify this product. Doing so may cause
the safety functions to stop working properly.
!WARNING Do not use the MS4800 system in environments where flammable or explo-
sive gases are present. Doing so may result in explosion.
!WARNING Perform daily and 6-month inspections for the MS4800 system. Otherwise,
the system may fail to work properly, resulting in serious injury.
!WARNING If the MS4800 system is used in an environment where foreign materials such
as spatter may adhere to the product use a cover to protect the MS4800 sys-
tem or inspect and clean the MS4800 system periodically.
!WARNING Do not use the MS4800 system in an athmosphere containing oil mist or cor-
rosive gas. Failure to do so may result in damage of the product.
!WARNING When scrapping the MS4800 system, please make sure to comply with the
waste treatment regulations of the country where the product has been used.
Precautions for Safe Use
3
3
Precautions for Safe Use
Make sure to observe the following precautions that are necessary for ensur-
ing safe use of the product.
• Thoroughly read this manual and understand the installtion procedures,
operation check procedures, an d maintenance procedures before using
the product.
• Loads must satisfy both of the following conditions:
• Not short-circuited
• Not used with a current that is higher than the rating
• Do not drop the product
• Dispose of the product in accordance with the relevant rules and regula-
tions of the country or are where the product is used.
Precautions for Correct Use
4
4
Precautions for Correct Use
Observe the precautions described below to prevent operation failure, mal-
functions, or undesirable effects on product performance.
4-1
Installation environment
Do not install the MS4800 system in the following types of environments:
• Areas exposed to intense interference light, such as direct sunlight
• Areas with high humidity where condensation is likely to occur
• Areas where corrosive gases are present
• Areas exposed to vibration or shock levels higher than in the specification
provisions
• Areas where the product may come into contact with water
• Areas where the product may get wet with oil that can solve adhesive
Do not use radio equipment such as cellular phones, walkie-talkies, or trans-
ceivers near the MS4800 system.
4-2
Wiring and installation
• Make sure to perform wiring while the power supply is OFF. Otherwise,
the MS4800 system may fail to operate due to the diagnosis function.
• When replacing the cable connectors with other types of connectors, use
connectors that provide a proper grade of protection.
• Properly perform the wiring after confirming the signal names of all the
terminals.
• Do not operate the control system until 2 seconds or more (2,2 seconds
or more in case of series connection) after turning ON the power of the
MS4800 system.
• Be sure to route the MS4800 system cable separate from high-potential
power lines or through an exclusive conduit.
• When using a commercially available switching regulator power supply,
make sure to ground the FG terminal (frame ground terminal).
• Install the emitter and receiver so that their vertical direction should
match.
4-3
Cleaning
Do not use thinner, benzene, or acetone for cleaning, they affect the product's
resin parts and paint on the case.
4-4
Object detection
The MS4800 system cannot detect transparent and/or translucent objects.
Important Safety Warnings
!WARNING Read and understand this section prior to installing an MS4800 system.
An MS4800 system is a general purpose sensing device designed to guard
personnel working around moving machinery.
Whether a specific machine application and MS4800 system installation com-
plies with safety regulations depends on the proper application, installation,
maintenance and operation of the MS4800 system. These items are the
responsibility of the purchaser, installer and employer.
The employer is responsible for the selection and training of personnel to
properly install, operate and maintain the machine and its safeguarding sys-
tems. An MS4800 system should only be installed verified and maintained by
a qualified person. A qualified person is defined as "an individual who under-
stands, is trained on, and demonstrates competence with the construction,
operation or maintenance of the machinery and the hazards involved."
To use the MS4800 system the following requirements must be met:
• The national/international rules and regulations apply to the installation,
use and periodic technical inspections of the safety light curtain, in partic-
ular:
• Machine Directive (98/37/EC)
• Equipment Usage Directive (89/655/EC)
• The work safety regulations/safety rules
• Other relevant health and safety regulations
• Observe the instructions in this manual regarding test regulations (e.g. on
use, mounting, installation or integration into the existing machine control
system) carefully.
• The tests must be carried out by specialist personnel or specially qualified
and authorized personnel and must be recorded and documented to
ensure that the tests can be reconstructed and retraced at any time.
• Check the effectiveness of the protective device after every change
because a change may degrade the safety function.
• The operating instructions must be made available to the operator of the
machine where the MS4800 system is installed.
• The machine operator is to be instructed in the use of the device by spe-
cialist personnel and must be instructed to read the operating instructions.
• The guarded machine must not present a hazard from flying parts.
• The guarded machine must have a consistent stopping time and ade-
quate control mechanisms.
• Additional guarding may be required for access to dangerous areas not
covered by the MS4800 system.
Protection of the environment
This product has been designed to minimize environmental impact. For this
reason please note that disposal of irreparable/unserviceable devices has to
be in compliance with your local/national rules and regulations. Please con-
tact your local OMRON sales representative for assistance.
The MS4800 safety light curtain family is available in two versions. These ver-
sions are identified as the MS4800-EA and EB versions. Configuration of the
safety light curtains can be changed through selector switches located under
an access cover.
MS4800 series feature comparison
Feature
MS4800-EB
MS4800-EA
Flex Bus, Multi segmented Head Configurations
X
X
Scan Code for Cross-Talk-Mitigation
X
X
EDM External Device Monitoring
X
X
Adjustable Mounting Brackets and T-Slots
X
X
Non-shielded Main Cables
X
X
Two PNP safety outputs
X
X
Auxiliary outputs (PNP only)
X
X
Muting through RM6 Muting Module
X
Floating Blanking
X
Fixed Blanking
X
Range Selection
X
X
System Components and Indicators
Chart
Chart
1
Receiver
7
Transmitter
2
Individual beam Indicators (one with every beam) -
Red LED
8
Detection Zone
3
Blanking Active - Amber LED
9
Flip door, Access to configuration switches (on
transmitter and receiver)
4
INTERLOCK or ALARM indicator - Yellow LED
10
5
MACHINE RUN/STOP indicator - Green/Red LED
11
Status Indicator - Yellow LED
6
RECEIVER connections M12 (Male)
12
Slide Mounting T-Slot
1
+24 V DC - Brown
13
Transmitter connections M12 (Male)
2
0 V DC - Blue
1
0 V DC - Blue
3
Earth - Green
2
+24 V DC - Brown
4
OSSD 2 - White
3
MTS - White
5
Start or EDM (Mode Select) - Yellow
4
MTS return - Black
6
EDM - Red
5
Earth - Green
7
Auxiliary Out - Pink
8
OSSD 1 - Black
RECEIVER
TRANSMITTER
DETECTION
ZONE
TRANSMITTER
LED INDICATOR
ALTERNATE
T-SLOT
MOUNTING
RECEIVER LED
INDICATORS
2
3
8
4
5
6
7
1
2
5
3
4
1
1
2
3
4
5
6
7
8
9
10
11
12
13
3
2
1
5
4
6
1
2
3
2
1
5
4
6
WITH
DOOR
ENDCAP
ACCESS
SELECTOR SWITCH
RECEIVER
TRANSMITTER
RECEIVER SWITCHES
TRANSMITTER SWITCHES
MS4800 - SELECTOR SWITCH ACCESS
ON
ON
ON
The MS4800 system is a microprocessor-controlled, infrared, transmitted-
beam safety light curtain. The system consists of a receiver assembly and a
transmitter assembly. The receiver and transmitter assemblies are not physi-
cally interconnected.
It complies with a Type 4 according to EN/IEC 61496 and category 4 accord-
ing to EN954-1.
An MS4800 system is used where personnel protection is required. Typical
applications include packaging machines, back side protection of presses and
textile machinery.
4-1
Operating States
The operating condition of an MS4800 system is described in terms of states.
The following operating states exist for an MS 4800 system.
4-1-1
Machine Run
The two receiver safety outputs are in the ON state, the green MACHINE RUN
indicator is lit, and the auxiliary output is in a state consistent with its configu-
ration. The protected machine is allowed to operate. Pressing and releasing
the start button has no effect.
4-1-2
Machine Stop
The two receiver safety outputs are in the OFF state the red MACHINE STOP
indicator is lit, and the auxiliary output is in a state consistent with its configu-
ration. The protected machine is not allowed to operate.
4-1-3
Interlock
The two receiver safety outputs are in the OFF state, the red MACHINE STOP
indicator and yellow INTERLOCK indicator are lit. The auxiliary output is in a
state consistent with its configuration. The INTERLOCK state does not allow
the protected machine to operate until the detection zone is clear of obstruc-
tions and the start button is pressed and released.
4-1-4
Alarm
The two receiver safety outputs are in the OFF state, the red MACHINE STOP
indicator is lit, the yellow INTERLOCK indicator is flashing and the auxiliary
output is in the OFF state. The alarm state does not allow the protected
machine to operate. The primary difference between ALARM and INTER-
LOCK is that the MS4800 system will remain in the alarm state until the alarm
is corrected, and then applying a power cycling or an external start button
press and release.
System operating modes determine the start-up and operating behavior of an
MS4800 system. Operating modes definitions rely on the operating states
presented above. Operating mode selection may be performed via the config-
uration switches on the MS4800 transmitter and receiver.
Note If internal alarms are detected by the system during power-up or operation, it
will enter the Alarm state with its safety outputs in the OFF state.
4-2-1
Automatic start
The MS4800 will power-up with its safety and auxiliary outputs OFF, and if the
detection zone is not obstructed, enters the MACHINE RUN state. In this
state, when an object is sensed entering the detection zone, the MS4800 sys-
tem will change from MACHINE RUN to MACHINE STOP and remain in this
state until the obstruction is removed. Once the detection zone is clear, the
MS4800 system will automatically change from MACHINE STOP to MACHINE
RUN.
4-2-2
Start/Restart Interlock
The MS4800 will power-up with its safety outputs off end enter the INTER-
LOCK state if the detection zone is clear (or the fixed blanking pattern is satis-
fied) and no alarms are detected. To initially enter the MACHINE RUN state
the operator must press and release the Start button. Once in the MACHINE
RUN state, when an object is sensed entering the detection zone, the system
will change to the MACHINE STOP state. When the detection zone is cleared,
the system will not automatically change to MACHINE RUN but enter the
INTERLOCK state instead. The operator must always press and release the
Start button to enter MACHINE RUN. If the detection zone is not clear the
Start button will have no effect.
Note The definitions above mention a start button. See SECTION 11 Connection to
the Machine Control Circuit for wiring of the start button.
4-3
MS4800FS Cascaded Series
The MS4800 series safety light curtain is available in a "cascaded" version,
referred to as the MS4800FS series. The MS4800FS series allows multiple
transmitters/receivers to be "daisy-chained" in series. This type of arrange-
ment permits the MS4800FS to guard multiple areas of a machine.
4-3-1
MS4800FS Requirements
The MS4800FS is offered in protective heights ranging from 280 mm to
1800 mm for 14 mm resolution and 280 mm to 2120 mm for 30 mm resolu-
tion.
• An MS4800FS system has a maximum size limitation based on the num-
ber of beams. A master (first) segment cannot exceed 180 beams and the
total of the combined segments cannot exceed 256 beams.
• A cascaded slave segment cannot exceed 128 beams.
• An MS4800FS system may have up to four daisy-chained segments. As
long as the total number of beams does not exceed 256.
• The interconnect cable length limitation between any two segments is
10 meters.
MS4800FS Cascaded Series
Section 4-3
• It is possible to mix segments with different resolutions within an
MS4800FS system.
4-3-2
MS4800FS Segment Reduction Restart Procedure
!WARNING Do not remove cascaded segments from your installation without making sure
that the accessible areas are protected by other measures. Failure to do so
may result in serious injury.
When you reduce the number of cascaded segments you cause a flex bus
fault. The MS4800FS will enter a fault condition, indicated by error code "95"
on the indicators in the bottom part of the device. This fault code indicates that
there was a reduction in the number of cascaded segments. If the number of
segments is reduced while power is off, the light curtain will power on with
fault code "100".
There is one possibility to clear this fault and restore operation on the reduced
size MS4800FS. The start switch needs to be pressed while the power is
applied. The three indicator LEDs (red, yellow, amber) will flash for approxi-
mately three seconds. The start switch must be released while the LEDs are
flashing to clear fault code "100". Since the MS4800FS has a configurable
start input, care must be taken to ensure that the correct contact configuration
is used and that it is wired properly.
The transmitter will not fault if the number of segments is reduced. However,
to operate normally the transmitter must always match the receiver in the
number of segments and beams.
"Cascaded" Segment
"Cascaded" Segment
Receiver
Segment
Transmitter
Segment
!WARNING Use of Fixed Blanking and Floating Blanking will make an MS4800 system
less sensitive to objects in the detection zone. Improper use of these features
can result in severe injury to personnel. Fixed Blanking may require a hard
barrier guard. Fixed Blanking and Floating Blanking may require an increase
in the safety distance. Read the following section carefully.
5-1
Fixed Blanking
Fixed Blanking allows a system to blank optical beams and record the exact
pattern. A system can record and store a single pattern. The protected zone's
object detection is then based on the stored pattern. All obstructed optical
beams recorded during the selection must remain blocked and all clear
beams recorded during the selection must remain clear for the system to
enter or remain in the MACHINE RUN state.
A Fixed Blanking pattern may consist of more than one Fixed Blanked area.
Individual Fixed Blanked areas must be separated by at least one beam that
is always clear. A Fixed Blanking area may not crossover between "flexible"
segment boundaries.
Each Fixed Blanked area has a size and positional tolerance of ±1 beam to
allow for slight position variance and only the two beams on the edges of the
blanked area are allowed to vary. Because of this position tolerance, a reduc-
tion of the optical resolution takes place on the border area of Fixed Blanking
patterns. This reduction comprises two beams.
Tolerance effect of Fixed Blanked area on Resolution
Note The tolerance does not reduce the resolution of the entire light curtain, only
the ends of Fixed Blanked Areas. The user must consider the increased reso-
lution of the two beams at the ends of each Fixed Blanked Area.
Fixed Blanking Area
Obstruction
Additional Hard Guarding
Light Curtain
Light Curtain
Detection Zone
Standard Resolution
Effective Resolution at Ends of Fixed Blanked Areas
14 mm
34 mm
30 mm
60 mm
The effect of this tolerance also allows the number of blocked beams to vary
±1. For example, a Fixed Blanked area of 8 blanked beams is allowed to
increase to 9 beams or decrease to 7 beams and the light curtain will remain
in MACHINE RUN.
There is an exception when there is only one clear beam separating Fixed
Blanked areas. For only this case, there is no positional tolerance allowed on
that side of the clear beam for the object closest to the entry endcap so that
clear beam can only be used by the object further away from the entry end-
cap. See the following table:
The minimum number of beams in a Fixed Blanking area is one. If only one
beam is blanked, the number of blocked beams has a size tolerance of +1/-0
meaning the number of blocked beams can increase to two but the area can-
not be completely eliminated.
The Fixed Blanking pattern must not prevent the light curtain from synchroniz-
ing. This means that the size of the blanked object can not exceed certain lim-
its as long as synchronization is maintained.
Fixed Blanking is allowed during all modes of operation (automatic start, start
and start/restart interlock).
No Fixed
Blanking
Fixed
Blanking
Enabled
Fixed
Blanking
Enabled
Fixed
Blanking
Enabled
Fixed
Blanking
Enabled
Fixed
Blanking
Enabled
MACHINE
STOP
MACHINE
RUN
MACHINE
RUN
MACHINE
RUN
MACHINE
STOP
MACHINE
STOP
Clear Optical
Channel
Blocked Optical Chan-
nel
Optical Channel
Selected by Fixed
Blanking
Opposite to entry endcap end
Fixed blanking enabled
Fixed blanking enabled
Fixed blanking enabled
MACHINE RUN
MACHINE RUN
MACHINE STOP
Entry endcap end
Selecting Fixed Blanking with selector switches
To use Fixed Blanking, the operator enables the option using the selector
switches. A new Fixed Blanking pattern is recorded when the MS4800
receiver is in MACHINE STOP, the blanking function is active and the Program
function is activated. If the Fixed Blanking feature is disabled, the stored pro-
tected zone patterns are cleared.
1.
The obstruction is placed
within the detection zone
and the receiver goes to
MACHINE STOP state.
An authorized user then
sets the selector switches
in the receiver endcap to
select Fixed Blanking En-
able. The MS4800 enters
a fault state and power is
cycled or the Start switch is activated to clear the fault. When the receiver
powers up it will be in Fixed Blanking mode with the red and amber LEDs
lit.
2.
The authorized user then
enables
the
Program
switch by setting both
Fixed Blanking switches to
the off position and then
both to the on position.
When
the
first
Fixed
Blanking switch is flipped,
the red LED begins flash-
ing at a rate of 3Hz. When
the final Fixed Blanking
switch is flipped, both the red and amber LEDs and the IBIs (Individual
Beam Indicators) of the blocked beams start flashing to indicate the Pro-
gram switch is enabled. The authorized user has 10 minutes to complete
the programming of a pattern.
3.
To program a pattern, the
authorized user must flip
(off/on or on/off) the Pro-
gram switch once. Once
pattern is programmed the
yellow LED (INTERLOCK)
turns
on.
During
10
minute period, the user
may program as many
times as needed, allowing
for
adjustment
in
the
placement of the obstruction.
IBIs of blocked
beams are On.
Amber LED turns on to indicate
in Fixed Blanking mode.
3
2
1
5
4
6
3
2
1
5
4
6
ON
ON
IBIs of blocked
beams flash.
Red and amber LEDs and IBIs
flash to indicate the
Program switch is active.
3
2
1
5
4
6
3
2
1
5
4
6
ON
ON
3
2
1
5
4
6
3
2
1
5
4
6
ON
ON
off
off
on
on
SWA
SWB
IBIs of blocked�
beams flash.
Yellow LED turns on to indicate �
the pattern has been programmed�
and the Start button is active.
3
2
1
5
4
6
3
2
1
5
4
6
ON
ON
on
on
Flip
SWA
SWB
The user must then press
and release the Start but-
ton or perform a power cy-
cle. The MS4800 receiver
then resets. If no faults are
detected and the state of
the optical beams match-
es the recorded Fixed
Blanking pattern, the re-
ceiver will enter the IN-
TERLOCK or MACHINE RUN condition depending upon the selected Start
Mode. The amber receiver Blanking Active LED will be on.
5.
If the 10 minutes period
expires, the amber LED
and IBIs (Individual Beam
Indicators) quit flashing
and the yellow LED (IN-
TERLOCK) goes on. The
user can start another
programming
sequence
by setting both Fixed
Blanking switches off and
then on. The user may
start normal operation by a press and release of the start button or by per-
forming a power cycle.
6.
To exit Fixed Blanking the
user sets both selector
switches to the off posi-
tion, then either presses
and releases the Start but-
ton or performs a power
cycle. The receiver will
power up with the amber
LED off.
IBIs of blocked
beams off.
Amber LED is on to indicate
in Fixed Blanking mode.
3
2
1
5
4
6
3
2
1
5
4
6
ON
ON
on
on
SWA
SWB
IBIs of blocked
beams on.
Amber LED is off to indicate
in Fixed Blanking is disabled.
3
2
1
5
4
6
3
2
1
5
4
6
ON
ON
on
on
SWA
SWB
IBIs of blocked
beams on.
The amber LED and IBIs quit flashing
to indicate program switch is disabled.
The yellow LED turns on to indicate the
Start button is active.
3
2
1
5
4
6
3
2
1
5
4
6
ON
ON
off
off
SWA
SWB
!WARNING Use of Fixed Blanking and Floating Blanking will make the MS4800 system
less sensitive to objects in the detection zone. Improper use of these features
can result in severe injury to personnel. Fixed Blanking may require a hard
barrier. Fixed Blanking and Floating Blanking may require an increase in the
safety distance. Read the following section carefully.
One channel can be obstructed at any location in the detection zone as long
as the optical synchronization is maintained. Please refer to chapter 5-4 Opti-
cal Synchronization for further details.
This means that an object can freely float from one end of the protective field
to the other without the MS4800 system entering the MACHINE STOP state.
The obstructed channels are not fixed at a single location but "float" through
the detection zone.
5-2-1
Selecting Floating Blanking with selector switches
Using the selector switches an authorized user can activate the Floating
Blanking function. This allows the system to operate with one obstructed opti-
cal beam anywhere within the protected zone. This obstruction is permitted
anywhere within the protected zone and is permitted to move over time. After
setting the appropriate selector switches, the receiver enters the Power-On
Self Test state and if no faults are detected the receiver shall enter the INTER-
LOCK or MACHINE RUN condition depending upon the selected operating
mode.
!WARNING Two-Beam Floating Blanking is not available on the MS4800 system.
Floating
Blanking
Inactive
1
Channel
Floating
Blanking Active
1
Channel
Floating
Blanking Active
1
Channel
Floating
Blanking Active
1
Channel
Floating
Blanking Active
Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
System
Response
1
Exception
MACHINE STOP
0
Exceptions
Machine
Run
1
Exception
Machine
Run
2
Exceptions
MACHINE STOP
2
Exceptions
MACHINE STOP
Clear Optical Channel
Optical Channel is obstructed
Floating Blanking Effects on Minimum Object Resolution
Standard Minimum Object Resolution
(No Floating Blanking)
Minimum Object Resolution with
1 Beam Blanking
14 mm
24 mm
30 mm
50 mm
Fixed Blanking with Floating Blanking
Section 5-3
5-3
Fixed Blanking with Floating Blanking
!WARNING Use of Fixed Blanking and Floating Blanking will make MS4800 system less
sensitive to objects in the detection zone. Improper use of these features can
result in severe injury to personnel. Fixed Blanking may require a hard barrier
guard. Fixed Blanking and Floating Blanking may require an increase in the
safety distance. Read the following section carefully.
Possible combinations:
When both Fixed Blanking and Floating Blanking are selected, the floating
channels are allowed to occur anywhere within the detection zone except the
area selected by Fixed Blanking.
5-3-1
The effect of Fixed or Floating Blanking on minimum object
resolution
When fixed Blanking and/or Floating are active, the safe mounting distance is
affected. Fixed and Floating Blanking desensitize the light curtain and
increase the size of the minimum detectable object. The increase is equal to
the beam spacing distance for each beam that is disabled.
If the size of the object detected by the system increases the minimum safe
distance must also be increased. Use the minimum object sensitivity given in
the following tables to determine the new figure to use when computing the
safety distance.
MS4800 system - 14 mm resolution
MS4800 system - 30mm resolution
Function
Fixed Blanking
Floating Blanking
Fixed Blanking
N/A
Yes
Floating Blanking
Yes
N/A
Total number of Beams Disabled by
Fixed and/or Floating Blanking
Effective Resolution
None
14 mm
1 Beam
24 mm
2 Beams
34 mm
3 Beams
44 mm
4 Beams
54 mm
5 Beams
64 mm
> 64 mm
Total number of Beams Disabled by
Fixed and/or Floating Blanking
Effective Resolution
None
30 mm
1 Beam
50 mm
> 64mm
The synchronization between the MS4800 system transmitter and receiver is
optical, so the system does not use one specific beam. To establish synchro-
nization the system needs to have a certain number of consecutive clear
beams (see following table) within the first master segment. If they are not sat-
isfied, the system will enter a MACHINE STOP state and every other Individ-
ual Beam Indicator will light. When the beams are cleared, the system will re-
synchronize itself and enter a state consistent with its operating mode. Once
the synchronization is established, it can be maintained as long as the
required number of consecutive clear beams can be satisfied anywhere in the
system (including flex segments).
Because of these restrictions, when programming a fixed blanking object(s),
the size of the fixed or monitored blanking object(s) must comply with the
number of consecutive clear beams stated in the previous table within the first
master segment.
In addition to that, any fixed or monitored blanking programming must be done
with at least one (1) clear beam on each flex segment.
Light Curtain Beam Count
Synchronization Beam Requirement
12 - 16 beams
6 consecutive clear beams
17 - 32 beams
7 consecutive clear beams
33 - 64 beams
8 consecutive clear beams
65 - 128 beams
9 consecutive clear beams
129 - 256 beams
10 consecutive clear beams
Diagnostic and Test Features
6-1
Individual Beam Indicators (IBI)
All MS4800 systems have a visible red LED as an Individual Beam Indicator
adjacent to each infrared beam. These IBIs are located on the receiver. The
IBI will light when the infrared beam fails to meet the conditions necessary for
the system to remain in the MACHINE RUN state. When less than 10 consec-
utive beams are clear, every other IBI will light indicating that the MS4800 is
not synchronized. IBIs are not a safety critical component. An IBI failure will
not cause an alarm condition and the system will continue to operate.
Additionally, error codes are displayed using the IBIs close to the connector
endcap.
6-2
External Device Monitoring (EDM)
EDM is an important safety function. It monitors the MS4800 system interface
to the guarded machine, checks to ensure that the control elements are
responding correctly to the light curtain and detects any inconsistency
between the two external control devices. This is necessary to detect a mal-
function within the interface which prevents a stop signal from reaching the
machine controller. The connection for the EDM is made at the receiver. On
power-up, the MS4800 system looks for a closed to 0VDC condition. If this is
found, it will enter a state consistent with the selected operating mode. When
the MS4800 system enables its safety outputs, it monitors the external
devices for a closed to open transition. This transition must occur within
300ms or the MS4800 system will then enter an alarm state. Additionally, if
the EDM connections are incorrectly wired, the system will enter an alarm
state.
Note For proper operation of the MS4800 system when EDM is not active, the EDM
input must be wired to the MS4800 system 0 VDC line.
The EDM function can be activated and deactivated using the selector
switches on the receiver unit.
6-3
Machine test signal (MTS)
Some applications require that the machine guarding system be tested by the
machine controller during a non-hazardous portion of the machine cycle to
verify that the guarding system is functioning properly. The MTS option on the
transmitter provides this capability. The MTS is provided by placing a nor-
mally-closed switch across the MTS and MTS Return lines of the transmitter.
When the transmitter recognizes a close-to-open transition on this switch a
beam block state will be simulated on the transmitter and the receiver will
enter the MACHINE STOP state. MTS is active as long as the switch is held
open.
6-4
Range selection
The MS4800 offers operating range selection: short range is 3 m and long
range is 7 m for the 14 mm models. For the 30mm models the short range is
8m and long range is 20 m. This function is useful when there are many light
curtains operating within a small space and the possibility of cross-talk is
likely.
The characteristic of the Start/Restart Input is shown in the following sche-
matic:
MS4800
Start
N.O.
+24 VDC
0 VDC
Reset
+24 VDC
Using selector switches to set features
!WARNING Make sure that foreign objects such as water, oil, or dust do not enter the
inside of the MS4800 system while the cover for the selector switches is open.
7-1
Access to the selector switches
The switches are located behind a flip door on both the transmitter and
receiver. The flip up doors are opened by loosening two retaining screws (see
illustration below).
7-1-1
Transmitter selector switch settings
ENDCAP WITH DOOR
SELECTOR SWITCH ACCESS
RCVR
XMTR
RECEIVER SELECTOR SWITCHES
TRANSMITTER SELECTOR SWITCHES
SELECTOR SWITCH ACCESS
3
2
1
5
4
6
1
2
3
2
1
5
4
6
ON
ON
ON
Switch Position
Function
Factory default
1
SCAN CODE
SCAN CODE A
2
MTS
MTS OFF
Scan Code
Frequency A 1 = Off
Frequency B 1 = On
MTS
Disabled 2 = Off
Enabled 2 = On
ON
MTS
Scan Code
TRANSMITTER SELECTOR SWITCHES
(Shown in factory default positions)
1
2
Operating mode selection
Section 7-2
7-1-2
Receiver selector switch settings
7-2
Operating mode selection
The operating mode is selected by setting position 1 of switches A and B,
located on the receiver. Any mismatch between the settings of switches A and
B will result in an alarm condition. The available operating modes are auto-
matic start and Start/Restart Interlock.
7-3
Selecting and programming Fixed Blanking
Refer to section 5-1 Fixed Blanking for details on selecting and programming
Fixed Blanking function.
7-4
Selecting and programming Floating Blanking
Floating Blanking is activated by setting position 4 of Switches A and B
located on the receiver.
Note When Floating Blanking is active, the amber LED will illuminate to indicate
that the system is operating in a less sensitive state.
7-5
Selecting External Device Monitoring (EDM)
EDM is activated by setting position 2 of Switches A and B located on the
receiver. Any mismatch between the settings of Switches A and B will result in
an alarm condition.
7-6
Selecting Machine Test Signal (MTS)
MTS is activated by setting position 2 located on the transmitter end cap.
Switch A Position
Function
Switch B Position
Function
Factory Default
1
Auto Start or Start/
Restart Interlock
1
Auto Start or Start/
Restart Interlock
Auto Start (OFF)
2
EDM
2
EDM
Disabled (OFF)
3
Scan Code
3
Scan Code
Scan Code A (OFF)
4
Floating Blanking 1
4
Floating Blanking 1
Disabled (OFF)
5
Fixed Blanking
5
Fixed Blanking
Disabled (OFF)
6
Program (Non-safety)
6
Range (Non-safety)
Program (toggle)
Long Range (ON)
RECEIVER SELECTOR SWITCHES
(Shown in factory default positions)
SW A
Auto/SRI
EDM
Fixed BK
Scan Code
FB1
Program
Auto/SRI
EDM
Fixed BK
Scan Code
FB1
Range
SW B
SW A
SW B
Operating Mode
Automatic Start
1 = Off
1 = Off
Start/Restart Int
1 = On
1 = On
EDM Disabled
2 = Off
2 = Off
EDM Enabled
2 = On
2 = On
Scan Code A
3 = Off
3 = Off
Scan Code B
3 = On
3 = On
FB1 Disabled
4 = Off
4 = Off
FB1 Enabled
4 = On
4 = On
Fixed Blanking
Disabled
5 = Off
5 = Off
Enabled
5 = On
5 = On
Program
6 = Toggle
Operating Range
Short Range
6 = Off
Long Range
6 = On
3
2
1
5
4
6
3
2
1
5
4
6
ON
ON
Selecting Scan Codes
Section 7-7
7-7
Selecting Scan Codes
The MS4800 receiver and transmitter offer scan code selection to minimize
cross talk. On the transmitter this is activated by setting position 1. On the
receiver this is activated by setting position 3 of switch A and switch B.
Note Both receiver and transmitter must be set to the same code.
Example:
Scan Code A
Scan Code B
Safety Outputs (OSSDs)
!WARNING This product is designed for use on a 24 VDC, negative ground (protective
earth) electrical system only. Never connect the MS4800 system to a positive
ground (protective earth) system. With a positive ground (protective earth)
wiring scheme, certain simultaneous shorts of both safety outputs may not be
detected and the guarded machine may not stop, resulting in severe operator
injury.
The MS4800 system receiver supplies two independent PNP type safety out-
puts to provide run/stop signals to the guarded machine. In the MACHINE
RUN state, the safety outputs are electrically conducting and source 625 mA
of current at 24 VDC. In the MACHINE STOP state, the outputs are not elec-
trically conducting.
8-2
Auxiliary Output
!WARNING Do not use the auxiliary output or external indicator output for safety applica-
tions. Human body may not be detected when MS4800 system fails, resulting
in serious injury.
This is not a safety output. The MS4800 system supplies one auxiliary output.
The configuration of this output is "PNP follow". So the signal on the auxiliary
output is similar to the status of the OSSD outputs. It will source up to 100 mA
at 24 VDC.
Safe Mounting Distances
!WARNING Never install an MS4800 system without
regard to the safety distance. If the MS4800
system is mounted too close to the point of
operation hazard, the machine may not stop in
time to prevent an operator injury.
An MS4800 system must be mounted far enough from the machine danger
zone so the machine will stop before a hand or other body part reaches the
hazardous area. This distance is called the safety distance. It is a calculated
number based on a formula.
The safety distance "S" is the minimum safe distance between the safety light
curtain and the point of operation (pinch point).
Calculation of the safety distance "S" is based on the European standard
EN999 and applies to safety light curtains that are used in industrial environ-
ments.
9-1
Safety distance for safeguarding danger points
!WARNING Additional countermeasures may be necessary to prevent access to the dan-
gerous area from above, below, the sides or the rear of the machine.
Light Curtain
S
S
Additional countermeasures
Direction of
approach
Safety distance for safeguarding danger points
Section 9-1
9-1-1
Calculation example for systems with a resolution of <40 mm
Formula according to EN999:
S = (K x T) + C
Where S =
minimum distance in millimeters from the danger zone to the
detection point, line, plane or zone. If the result of the calcula-
tion is less than 100 mm, a distance of at least 100 mm must
still be maintained.
K =
Approach speed in mm/s. In the close area of 500 mm, the
speed is calculated at 2000 mm/s. If the distance is greater
than 500 mm, K can be calculated as 1600 mm/s. In this
case, however, a minimum of 500 mm applies for the safety
distance.
T =
the overall system stopping performance in seconds
T = t1 + t2 + t3
t1 =
response time of the safety light curtain in seconds,
given in the table in chapter 16.
t2 =
response time of the safety interface tsi, if any.
t3 =
maximum stopping time of the machine tm in
seconds.
Please refer to the technical information of the safety
Interface and the machine for the response time and stopping
time details.
C =
8 x (d-14 mm), but not less than zero.
d =
minimum object resolution of the MS4800 system in
millimeters, therefore:
S =
(2000 mm/s x T) + 8 x (d-14 mm)
This formula applies for all minimum distances of S up to and
including 500 mm. The minimum value of S shall not be less
than 100 mm.
If S is found to be greater than 500 mm using the formula
above, then the formula below can be used. In this case the
minimum value of S shall not be less than 500 mm.
S =
(1600 mm/s x T) + 8 x (d-14 mm)
Safety distance for safeguarding danger areas
Section 9-2
9-2
Safety distance for safeguarding danger areas
!WARNING Additional countermeasures may be necessary to prevent access to the dan-
gerous area from above, below, the sides or the rear of the machine.
The height of the protective field "H" above the reference plane and the reso-
lution "d" of the MS4800 system have the following relationship:
Hmin = 15 x (d -50)
or
d = (Hmin / 15) + 50
Hmin = Height of the protective field above the reference plane,
maximum height = 1000 mm.
It is considered that if height is equal or less than 300 mm,
adults can not crawl under.
d =
resolution of the MS4800 system
S =
(K x T) + C
For K and T please refer to the previous chapter
C =
(1200 mm - 0,4 x H) but not less than 850 mm
(arm length)
H = Height of protective field above the floor
S =
(1600 mm x T) + (1200 - 0,4 x H)
H
S
Direction of
approach
50 mm - maximum distance
to avoid walking behind
Safety distance and beam heights in access guarding
Section 9-3
9-3
Safety distance and beam heights in access guarding
!WARNING Additional countermeasures may be necessary to prevent access to the dan-
gerous area from above, below, the sides or the rear of the machine.
According to EN999 and EN294:
The height of the protective field "H" above the reference plane and the reso-
lution "d" of the MS4800 system have the following relationship:
S =
(K x T) + C
For K and T please refer to the previous chapter
C =
8 x (d - 14)
d = resolution of the MS4800 system
S =
(2000 mm x T) + 8 x (d - 14)
H
S
L
Direction of
approach
Resolution
Lowest beam above
reference plane
Highest beam above
reference plane
Additional
amount C
(see formula)
14 mm
In accordance with
EN 294
In accordance with
EN 294
0 mm
30 mm
In accordance with
EN 294
In accordance with
EN 294
128 mm
!WARNING Install the sensor system so that it is not affected by reflective surfaces. Fail-
ure to do so may hinder detection, resulting in serious injury.
10-1 Reflective Surface Interference
A reflective surface adjacent to the detection zone can deflect the optical
beam and may cause an obstruction in the zone not to be detected. The
reflective surface may be part of the machine, mechanical guard or work-
piece. Therefore, a minimum distance (d) must exist between the reflective
object and the center line of the detection zone. The Test procedure (Appen-
dix B) must be used to test for this condition.
In this picture, the interruption is clearly detected. The reflective object is out-
side of the beam angle
The following pictures show the scenario if the reflective surface is too close
to the beam angle.
In this case, the interruption is not detected because the reflective object is
inside the beam angle.
Transmitter
Receiver
Beam Angle, a
d
Reflective Surface
Operating Range, R
a
a
Perimeter of danger area
Receiver
Reflective Surface
Perimter of danger area
Reflection
Interruption
a
Sensing Field
Transmitter
Cross Talk Mitigation
Section 10-2
The interruption is not detected because of the reflection. Reflective surface
interference may also appear above and below the sensing field.
Worst case alignment example
This example shows the minimum distance from the reflective surface, d, to
one side of the beam center line
10-2 Cross Talk Mitigation
To mitigate interference from other light curtains, the MS4800 system has two
possible scan codes, A and B. The transmitter and receiver units must be set
to the same scan code for the receiver to enter the MACHINE RUN state.
Transmitter
Receiver
Approach direction
Central beam
Light beam interrupted
d
Reflective Surface
Perimeter of danger area
Reflection
Interruption
a
Beam Angle, a
Transmitter
Receiver
Approach direction
Central beam
Light beam interrupted
d
Reflective Surface
Perimeter of danger area
Reflection
Interruption
a
Beam Angle, a
0
0,2
0,4
0,6
0,8
1
1,2
1,4
1,6
1,8
2
0,1 0,2 0,5
1
2
3
4
5
6
7
8
9
10 11
12
13 14
15 16
17
18 19
20
Range [m]
Minimum Distance d [m]
Scan Code A
Scan Code B
General Mounting Considerations
Section 10-3
10-3 General Mounting Considerations
10-3-1 Additional Guarding
Areas of access to the point of hazardous operation not guarded by the
MS4800 system must be protected by suitable means such as a fixed barrier
guard, an interlocked guard or a safety mat system.
10-3-2 Added Mounting Rigidity
It is recommended that when installing a
MS4800 larger than 1000 mm in length,
you use an additional mounting bracket.
This is to be installed using the T-slot on
the backside of the transmitter and
receiver.
Supplemental
Guarding
Supplemental
Guarding
Hazard
Zone
Ds
LIGHT CURTAIN
Supplemental
Guarding
Example
Mechanical
Barrier
Supplemental
Guarding
Supplemental
Guarding
MS4800 point of
operation guarding
MS4800FS 3-sided guarding
MS4800FS 2-Axis guarding
ALTERNATE
T-SLOT
MOUNTING
ALTERNATE
T-SLOT
MOUNTING
General Mounting Considerations
Section 10-3
10-3-3 Installation of Multiple Systems
When two or more MS4800 systems with the same scan code are mounted in
close proximity and in alignment with each other, precautions should be taken
to avoid one system interfering with another. This can be corrected by mount-
ing the transmitters and receivers back-to-back or stacked.
The scan code feature of the MS4800 system allows for placement of systems
in close proximity and in line with each other. The distinctive coding of the
beams provide for unique operation of a system while in view of another sys-
tem with a different scan code. Two unique codes are available on the
MS4800.
10-3-4 Detection Zone
The system detection zone is delineated by the inside edge of the transmitter
and receiver endcaps. The area outside these marks is not protected. Position
the system so that it is only possible to access the danger point through the
detection zone.
10-3-5 Alignment
Physical alignment of the transmitter and receiver is easiest when the system
is in the automatic start operating mode with Fixed Blanking inactive. The
units should be in the same plane and at equal height.
The Individual Beam Indicators will light when a part of the Safety Light Cur-
tain is out of alignment.
10-3-6 Input Power Requirements
The system operates directly from 24 VDC ±20%. Power to the system must
come from a power supply which meets the requirements of EN/IEC60204-1
and EN/IEC 61496-1.
The power supply must guarantee safe insulation from the mains voltage in
accordance with IEC60742 and be able to cover a drop of supply voltage of at
least 20 ms. Omron offers suitable power supplies. The power supply must
not supply any other parts of the machine with power other than the safety
components connected. Transmitters and receivers must be supplied from a
shared power supply and must be fused against overcurrent.
Transmitter
Receiver
Transmitter
Receiver
Machine 1
Machine 2
PREFERRED INSTALLATION
Code A
Code A
Machine 1
Transmitter
Transmitter
Receiver
Machine 2
Receiver
NOT RECOMMENDED INSTALLATION
Code A
Code A
Machine 1
Transmitter
Transmitter
Receiver
Machine 2
Receiver
Code A
Code B
General Mounting Considerations
Section 10-3
10-3-7 Requirements for Perimeter Guarding
In perimeter guarding applications the MS4800 system detection zone is
placed around the outside perimeter of a guarded machine. This placement
leaves space for personnel to stand between the detection zone and the haz-
ardous machine.
In this case, the guarded machine must only be restarted using a switch
located outside and with a full view of the area of hazardous motion. Opera-
tion of the MS4800 system In the Start/Restart Interlock operating mode is
suitable for perimeter guarding.
10-3-8 Marking Minimum Object Resolution
Serial number labels on the transmitter and receiver indicate possible mini-
mum object resolutions. During installation, use a permanent marker to
obscure the object resolution not set and add information about the effective
resolution. This will depend on whether no floating blanking or 1-beam floating
blanking is set.
Connection to the Machine Control Circuit
!WARNING This product is designed for use on a 24 VDC, negative ground (protective
earth) electrical system only. Never connect the MS4800 system to a positive
ground (protective earth) system. With a positive ground (protective earth)
wiring scheme, certain simultaneous shorts of both safety outputs may not be
detected and the guarded machine may not stop, resulting in severe operator
injury.
!WARNING Never use only a single safety output to control the machine. Should this sin-
gle output fail, the machine may not stop, resulting in severe operator injury.
The machine must be connected using both safety outputs.
The table below references Pin Numbers, Wire colors and signal names being
used with the MS4800 system.
The primary cables for the MS4800 system are industry standard non-
shielded cables with an M12 female connector. The receiver and transmitter
incorporate a 0,3 m pigtail with an M12 male connector.
We recommend to use the F39-JMR and F39-JMT cables to connect the
MS4800 system to the machine control system.
11-1 Interconnect cables for cascaded MS4800FS system
The segment-to-segment cable has a 4 contact M12 connector on each end.
The maximum cable length is 10 meters between segments.
The extension cables are available in lengths of 0.3 m, 0.5 m, 1 m, 2 m, 5 m
and 10 m. A MS4800FS system does not require an extension cable; it has a
150 mm integrated cable (pigtail).
MS4800FS systems are designed with internal circuit protection to protect
from damage when they are connected and disconnected (hot-swap) during
normal operation.
Receiver cable
Pin No. 1
Input power
Brown
+24VDC
Pin No. 2
Input power
Blue
GND
Pin No. 3
Input power
Green
Functional Earth
Pin No. 4
Output signal
White
OSSD2
Pin No. 5
Input signal
Yellow
Start
Pin No. 6
Input signal
Red
EDM
Pin No. 7
Output signal
Pink
Aux
Pin No. 8
Output signal
Black
OSSD1
Transmitter cable
Pin No. 1
Input power
Blue
GND
Pin No. 2
Input power
Brown
+24VDC
Pin No. 3
Input test
White
MTS
Pin No. 4
Input test
Black
MTS Return
Pin No. 5
Input power
Green
Functional Earth
Connection to two forcibly guided relays
Section 11-2
11-2 Connection to two forcibly guided relays
G7S and G7SA series relays provide forcibly guided relay outputs for machine
control. Please refer to the next drawing for details:
11-3 Connection to a safety relay unit
The following example shows a MS4800 system in combination with a G9SB
safety relay unit from Omron. The G9SB safety relay unit provides forcibly
guided relay contacts for the machine control system.
Power supply
+24VDC
GND
Protective Earth
Fuse
Earth GND +24V
DC
MTS
Ret. MTS
Earth GND +24V
DC
EDM Start Aux. OSSD
1
OSSD
2
K1
K2
*2
K1
K2
*2
*1
MS4800
Transmitter
MS4800
Receiver
*1
*2
K1
K2
M
MTS requires a NC contact.
If MTS is not used, please
connect MTS and MTS Ret.
Directly.
The K1 and K2 coils must be
suppressed. Please refer to
the documentation of the
relays or contactors for
further reference.
Power supply
+24VDC
GND
Protective Earth
Fuse
Earth GND +24V
DC
MTS
Ret. MTS
Earth GND +24V
DC
EDM Start Aux. OSSD
1
OSSD
2
K1
K2
K1
K2
*1
MS4800
Transmitter
MS4800
Receiver
*1
K1
K2
M
A1
A2
T12
T22
T31T32
23
13
14
24
G9SB-200-D
MTS requires a NC contact.
If MTS is not used, please
connect MTS and MTS Ret.
Directly.
!WARNING The muting and override functions disable the safety functions of the device.
You must ensure safety using other method when these functions are operat-
ing.
!WARNING Install muting sensors so that they can distinguish between the object that is
being allowed to pass through the detection zone and a person. If the muting
function is activated by the detection of a person, it may result in serious
injury.
!WARNING Muting lamps (external indicators) that indicate the state of the muting and
override functions must be installed where they are clearly visible to workers
from all the operating positions.
!WARNING Muting related time must be properly configured for its application by a suffi-
ciently trained and qualified person, and the person must have responsibility
for settings, especially when setting the muting time limit to infinite.
!WARNING Use independent 2 input devices for muting inputs.
!WARNING You must install MS4800 system muting sensor, and physical barrier, and con-
figure time settings for muting so that an operator should not enter hazardous
zone.
!WARNING Install the switch that activates the override in a location that provides a clear
view of the entire hazardous area and where it cannot be activated from within
the hazardous area. Make sure that nobody is in the hazardous area before
activating the override function.
12-1 Muting Controller RM-6
Muting with the MS4800 system is available together with the Muting Control-
ler RM-6.
The MS4800 and an RM-6 offer a limited set of muting functions. The follow-
ing list describes the muting functions that can be achieved with the MS4800:
• 2 Sensor muting
• 50 ms sensor input filtering
• Mute
bypass
allowed
(configurable
using
sensor
4
input,
+24 VDC = Enabled, 0 V or unconnected = Disabled)
• Mute
timeout
limit
(configurable
using
sensor
3
input,
+24 VDC = No Limit, 0 V or unconnected = 2 minute time option)
Muting Controller RM-6
Section 12-1
The MS4800 system requires a specific sequence to activate the muting func-
tion after the RM-6 is connected. Once the RM-6 is connected the system will
not operate until either the mute module is removed or the following sequence
is followed:
• The MS4800 will fault "71", (mute module enable and configuration
required)
• With the power OFF, the start button must be pressed and remain
pressed while the power is applied
• The three LEDs on the receiver end-cap will start flashing after 3 seconds
• The start button must be released within 5 seconds after the LEDs start
flashing
When this sequence is properly completed, the system will enable muting.
For further information please check the user manual of the RM-6.
Checkout and test procedure
13-1 Checkout Procedure
Once the MS4800 system has been configured, mounted, aligned and prop-
erly connected to the machine control system, the initial Checkout Procedure
detailed in Appendix A must be performed by qualified personnel. A copy of
the checkout results should be kept with the machine records.
13-2 Test Procedure
!WARNING The tests outlined in the Test Procedure in Appendix B must be performed at
installation, according to the employer's regular inspection program and after
any maintenance, tooling change set up, adjustment or modification to the
MS4800 system or the guarded machine. Where a guarded machine is used
by multiple operators or shifts, it is suggested that the test procedure be per-
formed at each shift or operator change. Testing ensures that the light curtain
and the machine control system work properly to stop the machine. Failure to
test properly could result in serious injury to personnel.
The test procedure must be performed by qualified personnel. To test the
MS4800 system with fixed blanking and floating blanking disabled, use the
OMRON STI supplied test object. For applications where fixed blanking or
floating blanking is enabled, see Table in chapter 5-3-1 The effect of Fixed or
Floating Blanking on minimum object resolution to determine the proper size
of the test object.
When using a MS4800 system set for Automatic Start Mode operation, in con-
junction with an OMRON safety relay module, it is necessary to verify that the
outputs of the safety relay unit can properly change state by causing an inten-
tional beam break at least every change of shift or 24 hours of operation.
13-3 Using the test object
When using the test object, guide it through
the detection zone as shown:
4800 system
4800 system
START
STOP
Accumulation of oil, dirt and grease on the front window of the MS4800 trans-
mitter and receiver can effect the system operation. Clean the window with a
mild detergent or glass cleaner. Use a clean, soft, lint-free cloth. Painted
MS4800 surfaces may be cleaned with a mild de-greasing cleaner or deter-
gent.
Specifications and additional information
15-1 System Specification
Performance
Protective height
240 mm - 1800 mm (14 mm resolution)
280 mm - 2120 mm (30 mm resolution)
Object Resolution
14 mm and 30 mm
Operating Range
0.3 m - 7 m (14 mm resolution), default
0.3 m - 3 m (14 mm resolution), DIP SW 6 option
0.3 m - 20 m (30 mm resolution), default
0.3 m - 8 m (30 mm resolution), DIP SW 6 option
Effective Aperture Angle
±2,5° maximum, transmitter and receiver according to
IEC61496-2 (2006)
Safety Output (OSSDs)
Two PNP safety outputs, each output sourcing
625 mA @ 24 VDC.
Short circuit protection
Response Time
Maximum: 59 ms
See table below for more details
Auxiliary Output
(non safety)
One PNP output sourcing 100 mA @ 24 VDC. This out-
put follows the OSSDs.
EDM - Monitor Input
50 mA @ 24 VDC
Start/Restart Input
10 mA @ 24 VDC, Normally open input
Light Source
Infrared Emitting LEDs,
Wavelength 880 nm
Power Dissipation: 180 mW
Class 1 per EN60825-1
Transmitter Indicator Lights ACTIVE (Yellow)
Receiver Indicator Lights
MACHINE RUN/STOP (Green/Red)
INTERLOCK/ALARM (Yellow)
BLANKING (Amber)
Mechanical
Housing Material
Polyurethane powder painted aluminum
Front Window Material
Acrylic, Red
End Cap Material
Polycarbonate
Mounting Bracket Material
Cold rolled Steel
Wiring connections
M12-connectors;
8-pin receiver and 5-pin transmitter
Weight
See table for more details
Power Input Transmitter
24 VDC ±20%, maximum current 285 mA
MTS Input
24 VDC ±20%, 20 mA typ.
Power Input Receiver
24 VDC ±20%, maximum current 1835 mA
Receiver 485 mA + AUX 100 mA +
OSSD1 625 mA + OSSD2 625 mA
Leakage current
< 1mA
Capacitive Load
< 4.7µF for OSSD output
Inductive Load
Please contact your Omron representative for further
information.
Test pulse data
t1: Test pulse ≤ 600 µs
t2: 4 ms ≤ Test interval ≤ 40 ms
t3: Repetition ≤ 5 min
Muting Option
24 VDC ±20%, 30 mA max.
Power Supply
Must meet the requirements of EN/IEC 60204-1 and
EN/IEC 61496-1, and must guarantee safe insulation
from the mains voltage in accordance with IEC 60742
and be able to cover a drop of supply voltage of at least
20 ms.
Protection class
(IEC 536 or VDE 106)
III
Environmental
Enclosure Rating
IP65
Operating Temperature
-10°C … +55°C
Storage Temperature
-25°C … +70°C
Relative Humidity
95% maximum, non-condensing
Vibration (IEC 60068-2-6)
10 - 55 Hz, 10g, maximum on all 3 axes
Shock (IEC 60086-2-29)
10g for 16 ms, 1000 shocks on all 3axes
Connections
Cable length
MS4800 Transmitter
Unshielded cables:
Max. 50 m, @ 0.32 mm²
We recommend to use the F39-JMT cables to con-
nect the MS4800 system to the machine control sys-
tem.
Cable length
MS4800 Receiver
Unshielded cables, length is depending on the maxi-
mum current consumption:
OSSD 1&2-load 625 mA: 12 m @ 0.5 mm²
OSSD 1&2-load 300 mA: 45 m @ 0.5 mm²
We recommend to use the F39-JMR cables to con-
nect the MS4800 system to the machine control
system.
Cable length
MS4800FS system
Shielded cables, M12 connector 4-pin, these cables are
available as accessories. Maximum length is 10 m
between segments
OSSD 1
OSSD 2
t1
t2
t3
t
Response time of MS4800 system
One segment system
Two segment system
Minimum
number of
beams
Maximum
number of
beams
Response
Time
Minimum
number of
beams
Maximum
number of
beams
Response
Time
0
16
14 ms
0
65
23 ms
17
71
23 ms
66
120
32 ms
72
126
32 ms
121
174
41 ms
127
180
41 ms
175
229
50 ms
181
235
50 ms
230
256
59 ms
236
256
59 ms
Three segment system
Four segment system
Minimum
number of
beams
Maximum
number of
beams
Response
Time
Minimum
number of
beams
Maximum
number of
beams
Response
Time
0
59
23 ms
0
53
23 ms
60
114
32 ms
54
108
32 ms
115
168
41 ms
109
162
41 ms
169
223
50 ms
163
217
50 ms
224
256
59 ms
218
256
59 ms
Conformity
AOPD(ESPE)
Type 4 acc. to EN/IEC 61496-1 (2004)
And EN/IEC 61496-2 (2006)
Safety category
MS4800E system is suitable for safety control systems
up to Category 4 acc. EN954-1 (1996)
Safety Integrity Level
MS4800E system is suitable for up to SIL 3 per
IEC 61508
PFH
3,5 * 10-08
Proof test interval
Every 2 years (based on max. number of channels in a
4 segment system including muting system).
MS4800 system Dimensional Drawing
Section 15-2
15-2 MS4800 system Dimensional Drawing
BRACKET
ROTATION
62.9 [2.48]
90.0°
T-SLOT
MOUNTING
BACK
VIEW
VIEW
RIGHT SIDE
VIEW
FRONT
VIEW
LEFT SIDE
VIEWS
TOP
INVE RTED
MOUNTING
BRACKETS
ALTERN ATE
(SELECTOR SWITCH)
WITH DOOR
ENDCAP
"A"
39.4 [1.55]
51.0 [2.01]
27.6 [1.09] 58.6 [2.31]
77.3
[3.04]
58.0 [2.28]
46.4 [1.82]
"C"
"B"
"E"
30.2 [1.19]
59.2 [2.33]
37.3 [1.47]
CL
23.2 [.91]
DIA.6.8 [.27]
18.5
[.73]
49.1 [1.93]
38.0 [1.50]
50.0 [1.97]
CABLE
195.0
[7.68]
TYP.
"D"
37.2 [1.47]
52.8 [2.08]
63.8 [2.51]
53.6 [2.11]
40.1 [1.58]
BOTTOM VIEW
IN-LINE "PIG TAIL" CABLE
69.6 [2.74]
38.1 [1.50]
MS4800 system data with 14 mm resolution
Section 15-3
15-3 MS4800 system data with 14 mm resolution
280 mm
320 mm
360 mm
400 mm
440 mm
480 mm
A
284,4
324,8
364,5
404,2
443,9
484,3
B
420,4
460,8
500,5
540,2
579,9
620,3
C
381,7
422,1
461,8
501,5
541,2
581,6
D
307,3
347,7
387,4
427,1
466,8
507,2
E
371,3
411,7
451,4
491,1
530,8
571,2
Weight
1,68 kg
1,81 kg
1,95 kg
2,13 kg
2,40 kg
2,49 kg
Number of
Beams
28
32
36
40
44
48
520 mm
560 mm
600 mm
640 mm
680 mm
720 mm
A
523,4
563,7
604,1
643,9
683,6
724,0
B
659,4
699,7
740,1
779,9
819,6
860,0
C
620,7
661,0
701,4
741,2
780,9
821,3
D
546,3
586,6
627,0
666,8
706,5
746,9
E
610,3
650,6
691,0
730,8
770,5
810,9
Weight
2,63 kg
2,81 kg
2,99 kg
3,18 kg
3,36 kg
3,54 kg
Number of
Beams
52
56
60
64
68
72
760 mm
800 mm
840 mm
880 mm
920 mm
960 mm
A
762,0
803,5
843,4
882,8
923,8
963,6
B
898,0
939,5
979,8
1018,8
1059,8
1099,6
C
859,3
900,8
941,1
980,1
1021,1
1060,9
D
784,9
826,4
866,7
905,7
946,7
986,5
E
848,9
890,4
930,7
969,7
1010,7
1050,5
Weight
3,76 kg
3,9 kg
4,08 kg
4,26 kg
4,45 kg
4,63 kg
Number of
Beams
76
80
84
88
92
96
1000 mm
1040 mm
1080 mm
1120 mm
1160 mm
1200 mm
A
1002,6
1042,9
1083,9
1122,3
1162,7
1203,8
B
1138,6
1178,9
1219,9
1258,3
1298,7
1339,8
C
1099,9
1140,2
1181,2
1219,6
1260,0
1301,1
D
1025,5
1065,8
1106,8
1145,2
1185,6
1226,7
E
1089,5
1129,8
1170,8
1209,2
1249,6
1290,7
Weight
4,81 kg
4,99 kg
5,17 kg
5,35 kg
5,53 kg
5,72 kg
Number of
Beams
100
104
108
112
116
120
1240 mm
1280 mm
1320 mm
1360 mm
1400 mm
1440 mm
A
1242,1
1281,8
1323,6
1361,0
1401,7
1443,4
B
1378,1
1417,8
1459,6
1497,0
1537,7
1579,4
C
1339,4
1379,1
1420,9
1458,3
1499,0
1540,7
D
1265,0
1304,7
1346,5
1383,9
1424,6
1466,3
E
1329,0
1368,7
1410,5
1447,9
1488,6
1530,3
Weight
5,94kg
6,08kg
6,26kg
6,44kg
6,62kg
6,80kg
Number of
Beams
124
128
132
136
140
144
MS4800 system data with 30 mm resolution
Section 15-4
15-4 MS4800 system data with 30 mm resolution
1480 mm
1520 mm
1560 mm
1600 mm
1640 mm
1680 mm
A
1481,8
1521,5
1563,3
1600,9
1641,3
1681,3
B
1617,8
1657,5
1699,3
1736,9
1777,3
1817,3
C
1579,1
1618,8
1660,6
1698,2
1738,6
1778,6
D
1504,7
1544,4
1586,2
1623,8
1664,2
1740,2
E
1568,7
1608,4
1650,2
1687,8
1728,2
1768,2
Weight
6,99 kg
7,17 kg
7,35 kg
7,53 kg
7,71 kg
7,89 kg
Number of
Beams
148
152
156
160
164
168
1720 mm
1760 mm
1800 mm
A
1720,8
1760,5
1802,9
B
1856,8
1896,5
1938,9
C
1818,8
1857,8
1900,2
D
1743,7
1783,4
1825,8
E
1807,7
1847,4
1889,8
Weight
8,07kg
8,26kg
8,44kg
Number of
Beams
172
176
180
240 mm
280 mm
320 mm
360 mm
400 mm
440 mm
A
244,6
284,4
324,8
364,5
404,2
443,9
B
380,6
420,4
460,8
500,5
540,2
579,9
C
341,9
381,7
422,1
461,8
501,5
541,2
D
267,5
307,3
347,7
387,4
427,1
466,8
E
331,5
371,3
411,7
451,4
491,1
530,8
Weight
1,55 kg
1,68 kg
1,81 kg
1,95 kg
2,13 kg
2,40 kg
Number of
Beams
12
14
16
18
20
22
480 mm
520 mm
560 mm
600 mm
640 mm
680 mm
A
484,3
523,4
563,7
604,1
643,9
683,6
B
620,3
659,4
699,7
740,1
779,9
819,6
C
581,6
620,7
661,0
701,4
741,2
780,9
D
507,2
546,3
586,6
627,0
666,8
706,5
E
571,2
610,3
650,6
691,0
730,8
770,5
Weight
2,49 kg
2,63 kg
2,81 kg
2,99 kg
3,18 kg
3,36 kg
Number of
Beams
24
26
28
30
32
34
720 mm
760 mm
800 mm
840 mm
880 mm
920 mm
A
724,0
762,0
803,5
843,4
882,8
923,8
B
860,0
898,0
939,5
979,8
1018,8
1059,8
C
821,3
859,3
900,8
941,1
980,1
1021,1
D
746,9
784,9
826,4
866,7
905,7
946,7
E
810,9
848,9
890,4
930,7
969,7
1010,7
Weight
3,54 kg
3,76 kg
3,90 kg
4,08 kg
4,26 kg
4,45 kg
Number of
Beams
36
38
40
42
44
46
MS4800 system data with 30 mm resolution
Section 15-4
960 mm
1000 mm
1040 mm
1080 mm
1120 mm
1160 mm
A
963,6
1002,6
1042,9
1083,9
1122,3
1162,7
B
1099,6
1138,6
1178,9
1219,9
1258,3
1298,7
C
1060,9
1099,9
1140,2
1181,2
1219,6
1260,0
D
986,5
1025,5
1065,8
1106,8
1145,2
1185,6
E
1050,5
1089,5
1129,8
1170,8
1209,2
1249,6
Weight
4,63 kg
4,81 kg
4,99 kg
5,17 kg
5,35 kg
5,53 kg
Number of
Beams
48
50
52
54
56
58
1200 mm
1240 mm
1280 mm
1320 mm
1360 mm
1400 mm
A
1203,8
1242,1
1281,8
1323,6
1361,0
1401,7
B
1339,8
1378,1
1417,8
1459,6
1497,0
1537,7
C
1301,1
1339,4
1379,1
1420,9
1458,3
1499,0
D
1226,7
1265,0
1304,7
1346,5
1383,9
1424,6
E
1290,7
1329,0
1368,7
1410,5
1447,9
1488,6
Weight
5,72 kg
5,94 kg
6,08 kg
6,26 kg
6,44 kg
6,62 kg
Number of
Beams
60
62
64
66
68
70
1440 mm
1480 mm
1520 mm
1560 mm
1600 mm
1640 mm
A
1443,4
1481,8
1521,5
1563,3
1600,9
1641,3
B
1579,4
1617,8
1657,5
1699,3
1736,9
1777,3
C
1540,7
1579,1
1618,8
1660,6
1698,2
1738,6
D
1466,3
1504,7
1544,4
1586,2
1623,8
1664,2
E
1530,3
1568,7
1608,4
1650,2
1687,8
1728,2
Weight
6,80kg
6,99kg
7,17kg
7,35kg
7,53kg
7,71kg
Number of
Beams
72
74
76
78
80
82
1680 mm
1720 mm
1760 mm
1800 mm
1840 mm
1880 mm
A
1681,3
1720,8
1764,5
1802,9
1840,6
1880,3
B
1817,3
1856,8
1896,5
1938,9
1976,6
2016,3
C
1778,6
1818,8
1857,8
1900,2
1937,9
1977,6
D
1740,2
1743,7
1783,4
1825,8
1863,5
1903,2
E
1768,2
1807,7
1847,4
1889,8
1927,5
1967,2
Weight
7,89 kg
8,07 kg
8,26 kg
8,44 kg
8,62 kg
8,80 kg
Number of
Beams
84
86
88
90
92
94
1920 mm
1960 mm
2000 mm
2040 mm
2080 mm
2120 mm
A
1922,8
1960,4
2000,1
2042,6
2079,6
2117,7
B
2058,8
2096,4
2136,1
2178,6
2215,6
2253,7
C
2020,1
2057,7
2097,4
2139,9
2176,9
2215,0
D
1945,7
1983,3
2023,0
2065,5
2102,5
2140,6
E
2009,7
2047,3
2087,0
2129,5
2166,5
2204,6
Weight
8,98 kg
9,16 kg
9,34 kg
9,53 kg
9,71 kg
9,89 kg
Number of
Beams
96
98
100
102
104
106
MS4800FS system Dimensional Drawing
Section 15-5
15-5 MS4800FS system Dimensional Drawing
90.0 °°
BRACKET
ROTATION
BACK
VIEW
VIEW
RIGHT SIDE
VIEW
FRONT
VIEW
LEFT SIDE
VIEWS
TOP
MULTIPLE
FLEX
SEGMENTS
ALTERNATE
T-SLOT
MOUNTING
VIEW
BTM
"A"
DETECTION
ZONE
"A"
DETECTION
ZONE
"C2"
CENTER
SLOT
MOUNTING
"B2"
58.8 [2.31]
58.8 [2.31]
27.8 [1.09]
39.4 [1.55]
39.4 [1.55]
27.8 [1.09]
58.8 [2.31]
77.3 [3.04]
58.0 [2.28]
46.4 [1.82]
"C1"
CENTER
SLOT
MOUNTING
"B1"
"D"
FIRST
SEGMENT
SHOWN
"E1"
LAST
SEGMENT
"E2"
MID
SEGMENTS
27.8 [1.09]
39.4 [1.55]
IN-LINE
"PIG TAIL"
CABLE
50.0 [1.97]
38.0 [1.50]
49.1 [1.93]
62.9 [2.48]
30.1 [1.19]
59.2 [2.33]
DIA 6.8 [.27]
23.2 [.91]
18.5 [.73]
37.2 [1.47]
37.3[1.47]
CL
FLEX CABLE
110.0 (4.33)
TYP.
CABLE
195.0 [7.68]
TYP.
52.8 [2.08]
MOUNTING
BRACKETS
INVERTED
53.6 [2.11]
63.8 [2.51]
40.1 [1.58]
51.0 [2.01]
51.0 [2.01]
51.0 [2.01]
69.6 [2.74]
38.1 [1.50]
51.0 [2.01]
MS4800FS system data with 14 mm resolution
Section 15-6
15-6 MS4800FS system data with 14 mm resolution
240 mm
280 mm
320 mm
360 mm
400 mm
440 mm
A
244,6
284,4
324,8
364,5
404,2
443,9
B1
380,6
420,4
460,8
500,5
540,2
579,9
B2
362,1
401,9
442,3
482,0
521,7
561,4
C1
341,9
381,7
422,1
461,8
501,5
541,2
C2
323,3
363,1
403,5
443,2
482,9
522,6
D
389,8
429,6
470,0
509,7
549,4
589,1
E1
326,0
365,8
401,4
445,9
481,4
525,3
E2
371,3
411,1
451,5
491,2
530,9
570,6
Weight
1,55 kg
1,68 kg
1,81 kg
1,95 kg
2,13 kg
2,40 kg
Number of
Beams
24
28
32
36
40
44
480 mm
520 mm
560 mm
600 mm
640 mm
680 mm
A
484,3
523,4
563,7
604,1
643,9
683,6
B1
620,3
659,4
699,7
740,1
779,9
819,6
B2
601,8
640,9
681,2
721,6
761,4
801,1
C1
581,6
620,7
661,0
701,4
741,2
780,9
C2
563,0
602,1
642,4
682,8
722,6
762,3
D
629,5
668,6
708,9
749,3
789,1
828,8
E1
561,2
604,8
641,4
685,5
725,3
761,2
E2
611,0
650,1
690,4
730,8
770,6
810,3
Weight
2,49 kg
2,63 kg
2,81 kg
2,99 kg
3,18 kg
3,36 kg
Number of
Beams
48
52
56
60
64
68
720 mm
760 mm
800 mm
840 mm
880 mm
920 mm
A
724,0
762,0
803,5
843,4
882,8
923,8
B1
860,0
898,0
939,5
979,8
1018,8
1059,8
B2
841,5
879,5
921,0
961,3
1000,3
1041,3
C1
821,3
859,3
900,8
941,1
980,1
1021,1
C2
802,7
840,7
882,2
922,5
961,5
1002,5
D
869,2
907,1
948,7
989,0
1028,0
1069,0
E1
805,4
841,4
884,9
921,4
964,2
1005,2
E2
850,7
888,7
930,2
970,5
1009,6
1050,5
Weight
3,54kg
3,76kg
3,90kg
4,08kg
4,26kg
4,45kg
Number of
Beams
72
76
80
84
88
92
960 mm
1000 mm
1040 mm
1080 mm
1120 mm
1160 mm
A
963,6
1002,6
1042,9
1083,9
1122,3
1162,7
B1
1099,6
1138,6
1178,9
1219,9
1258,3
1298,7
B2
1081,1
1120,1
1160,4
1201,4
1239,8
1280,2
C1
1060,9
1099,9
1140,2
1181,2
1219,6
1260,0
C2
1042,3
1081,3
1121,6
1162,6
1201,0
1241,4
D
1108,8
1147,8
1188,1
1229,1
1267,5
1307,9
E1
1045,0
1084,0
1124,3
1165,3
1203,7
1244,1
E2
1090,3
1129,3
1169,6
1210,6
1249,0
1289,5
Weight
4,63 kg
4,81 kg
4,99 kg
5,17 kg
5,35 kg
5,53 kg
Number of
Beams
96
100
104
108
112
116
MS4800FS system data with 30 mm resolution
Section 15-7
15-7 MS4800FS system data with 30 mm resolution
1200 mm
1240 mm
1280 mm
1320 mm
1360 mm
1400 mm
A
1203,8
1242,1
1281,8
1323,6
1361,0
1401,7
B1
1339,8
1378,1
1417,8
1459,6
1497,0
1537,7
B2
1321,3
1359,6
1399,3
1441,1
1478,5
1519,2
C1
1301,1
1339,4
1379,1
1420,9
1458,3
1499,0
C2
1282,5
1320,8
1360,5
1402,3
1439,7
1480,4
D
1349,0
1387,3
1427,0
1468,8
1506,2
1546,9
E1
1285,2
1323,5
1363,2
1405,0
1442,4
1483,1
E2
1330,5
1368,8
1408,5
1450,3
1487,7
1528,4
Weight
5,72 kg
5,94 kg
6,08 kg
6,26 kg
6,44 kg
6,62 kg
Number of
Beams
120
124
128
132
136
140
1440 mm
1480 mm
1520 mm
1560 mm
1600 mm
1640 mm
A
1443,4
1481,8
1521,5
1563,3
1600,9
1641,3
B1
1579,4
1617,8
1657,5
1699,3
1736,9
1777,3
B2
1560,9
1599,3
1639,0
1680,8
1718,4
1758,8
C1
1540,7
1579,1
1618,8
1660,6
1698,2
1738,6
C2
1522,1
1560,5
1600,2
1642,0
1679,6
1720,0
D
1588,6
1627,0
1666,7
1708,5
1746,1
1786,5
E1
1524,8
1563,2
1602,9
1644,7
1682,3
1722,7
E2
1570,1
1608,5
1648,2
1690,0
1727,6
1768,0
Weight
6,80 kg
6,99 kg
7,17 kg
7,35 kg
7,53 kg
7,71 kg
Number of
Beams
144
148
152
156
160
164
1680 mm
1720 mm
1760 mm
1800 mm
A
1681,3
1720,8
1764,5
1802,9
B1
1817,3
1856,8
1896,5
1938,9
B2
1789,8
1838,3
1878,0
1920,4
C1
1778,6
1818,8
1857,8
1900,2
C2
1760,0
1799,5
1839,2
1881,6
D
1826,5
1866,0
1905,7
1948,1
E1
1762,7
1802,2
1841,9
1884,3
E2
1808,0
1847,5
1887,2
1929,6
Weight
7,89 kg
8,07 kg
8,26 kg
8,44 kg
Number of
Beams
168
172
176
180
240 mm
280 mm
320 mm
360 mm
400 mm
440 mm
A
244,6
284,4
324,8
364,5
404,2
443,9
B1
380,6
420,4
460,8
500,5
540,2
579,9
B2
362,1
401,9
442,3
482,0
521,7
561,4
C1
341,9
381,7
422,1
461,8
501,5
541,2
C2
323,3
363,1
403,5
443,2
482,9
522,6
D
389,8
429,6
470,0
509,7
549,4
589,1
E1
326,0
365,8
401,4
445,9
481,4
525,3
E2
371,3
411,1
451,5
491,2
530,9
570,6
Weight
1,55 kg
1,68 kg
1,81 kg
1,95 kg
2,13 kg
2,40 kg
Number of
Beams
12
14
16
18
20
22
MS4800FS system data with 30 mm resolution
Section 15-7
480 mm
520 mm
560 mm
600 mm
640 mm
680 mm
A
484,3
523,4
563,7
604,1
643,9
683,6
B1
620,3
659,4
699,7
740,1
779,9
819,6
B2
601,8
640,9
681,2
721,6
761,4
801,1
C1
581,6
620,7
661,0
701,4
741,2
780,9
C2
563,0
602,1
642,4
682,8
722,6
762,3
D
629,5
668,6
708,9
749,3
789,1
828,8
E1
561,2
604,8
641,4
685,5
725,3
761,2
E2
611,0
650,1
690,4
730,8
770,6
810,3
Weight
2,49 kg
2,63 kg
2,81 kg
2,99 kg
3,18 kg
3,36 kg
Number of
Beams
24
26
28
30
32
34
720 mm
760 mm
800 mm
840 mm
880 mm
920 mm
A
724,0
762,0
803,5
843,4
882,8
923,8
B1
860,0
898,0
939,5
979,8
1018,8
1059,8
B2
841,5
879,5
921,0
961,3
1000,3
1041,3
C1
821,3
859,3
900,8
941,1
980,1
1021,1
C2
802,7
840,7
882,2
922,5
961,5
1002,5
D
869,2
907,1
948,7
989,0
1028,0
1069,0
E1
805,4
841,4
884,9
921,4
964,2
1005,2
E2
850,7
888,7
930,2
970,5
1009,6
1050,5
Weight
3,54 kg
3,76 kg
3,90 kg
4,08 kg
4,26 kg
4,45 kg
Number of
Beams
36
38
40
42
44
46
960 mm
1000 mm
1040 mm
1080 mm
1120 mm
1160 mm
A
963,6
1002,6
1042,9
1083,9
1122,3
1162,7
B1
1099,6
1138,6
1178,9
1219,9
1258,3
1298,7
B2
1081,1
1120,1
1160,4
1201,4
1239,8
1280,2
C1
1060,9
1099,9
1140,2
1181,2
1219,6
1260,0
C2
1042,3
1081,3
1121,6
1162,6
1201,0
1241,4
D
1108,8
1147,8
1188,1
1229,1
1267,5
1307,9
E1
1045,0
1084,0
1124,3
1165,3
1203,7
1244,1
E2
1090,3
1129,3
1169,6
1210,6
1249,0
1289,5
Weight
4,63 kg
4,81 kg
4,99 kg
5,17 kg
5,35 kg
5,53 kg
Number of
Beams
48
50
52
54
56
58
1200 mm
1240 mm
1280 mm
1320 mm
1360 mm
1400 mm
A
1203,8
1242,1
1281,8
1323,6
1361,0
1401,7
B1
1339,8
1378,1
1417,8
1459,6
1497,0
1537,7
B2
1321,3
1359,6
1399,3
1441,1
1478,5
1519,2
C1
1301,1
1339,4
1379,1
1420,9
1458,3
1499,0
C2
1282,5
1320,8
1360,5
1402,3
1439,7
1480,4
D
1349,0
1387,3
1427,0
1468,8
1506,2
1546,9
E1
1285,2
1323,5
1363,2
1405,0
1442,4
1483,1
E2
1330,5
1368,8
1408,5
1450,3
1487,7
1528,4
Weight
5,72 kg
5,94 kg
6,08 kg
6,26 kg
6,44 kg
6,62 kg
Number of
Beams
60
62
64
66
68
70
MS4800FS system data with 30 mm resolution
Section 15-7
1440 mm
1480 mm
1520 mm
1560 mm
1600 mm
1640 mm
A
1443,4
1481,8
1521,5
1563,3
1600,9
1641,3
B1
1579,4
1617,8
1657,5
1699,3
1736,9
1777,3
B2
1560,9
1599,3
1639,0
1680,8
1718,4
1758,8
C1
1540,7
1579,1
1618,8
1660,6
1698,2
1738,6
C2
1522,1
1560,5
1600,2
1642,0
1679,6
1720,0
D
1588,6
1627,0
1666,7
1708,5
1746,1
1786,5
E1
1524,8
1563,2
1602,9
1644,7
1682,3
1722,7
E2
1570,1
1608,5
1648,2
1690,0
1727,6
1768,0
Weight
6,80 kg
6,99 kg
7,17 kg
7,35 kg
7,53 kg
7,71 kg
Number of
Beams
72
74
76
78
80
82
1680 mm
1720 mm
1760 mm
1800 mm
1840 mm
1880 mm
A
1681,3
1720,8
1764,5
1802,9
1840,6
1880,3
B1
1817,3
1856,8
1896,5
1938,9
1976,6
2016,3
B2
1789,8
1838,3
1878,0
1920,4
1958,1
1997,8
C1
1778,6
1818,8
1857,8
1900,2
1937,9
1977,6
C2
1760,0
1799,5
1839,2
1881,6
1919,3
1959,0
D
1826,5
1866,0
1905,7
1948,1
1958,8
2025,5
E1
1762,7
1802,2
1841,9
1884,3
1922,0
1961,7
E2
1808,0
1847,5
1887,2
1929,6
1967,3
2007,0
Weight
7,89 kg
8,07 kg
8,26 kg
8,44 kg
8,62 kg
8,80 kg
Number of
Beams
84
86
88
90
92
94
1920 mm
1960 mm
2000 mm
2040 mm
2080 mm
2120 mm
A
1922,8
1960,4
2000,1
2042,6
2079,6
2117,7
B1
2058,8
2096,4
2136,1
2178,6
2215,6
2253,7
B2
2040,3
2077,9
2117,6
2160,1
2197,1
2235,2
C1
2020,1
2057,7
2097,4
2139,9
2176,9
2215,0
C2
2001,5
2039,1
2078,8
221,3
2158,3
1^96,4
D
2068,0
2105,6
2145,3
2187,8
2224,8
2262,9
E1
2004,2
2041,8
2081,5
2124,0
2161,0
2199,1
E2
2049,5
2087,1
2126,8
2169,3
2206,3
2244,4
Weight
8,98 kg
9,16 kg
9,34 kg
9,53 kg
9,71 kg
9,89 kg
Number of
Beams
96
98
100
102
104
106
List of models
Section 15-8
15-8 List of models
Basic version, 14 mm resolution, Standalone units without Flex connection
Type Name
Version
Resolution
[mm]
Length
[mm]
Operation
MS4800S-EB-014-0280
Basic
14 mm
280
Standalone
MS4800S-EB-014-0320
Basic
14 mm
320
Standalone
MS4800S-EB-014-0360
Basic
14 mm
360
Standalone
MS4800S-EB-014-0400
Basic
14 mm
400
Standalone
MS4800S-EB-014-0440
Basic
14 mm
440
Standalone
MS4800S-EB-014-0480
Basic
14 mm
480
Standalone
MS4800S-EB-014-0520
Basic
14 mm
520
Standalone
MS4800S-EB-014-0560
Basic
14 mm
560
Standalone
MS4800S-EB-014-0600
Basic
14 mm
600
Standalone
MS4800S-EB-014-0640
Basic
14 mm
640
Standalone
MS4800S-EB-014-0680
Basic
14 mm
680
Standalone
MS4800S-EB-014-0720
Basic
14 mm
720
Standalone
MS4800S-EB-014-0760
Basic
14 mm
760
Standalone
MS4800S-EB-014-0800
Basic
14 mm
800
Standalone
MS4800S-EB-014-0840
Basic
14 mm
840
Standalone
MS4800S-EB-014-0880
Basic
14 mm
880
Standalone
MS4800S-EB-014-0920
Basic
14 mm
920
Standalone
MS4800S-EB-014-0960
Basic
14 mm
960
Standalone
MS4800S-EB-014-1000
Basic
14 mm
1000
Standalone
MS4800S-EB-014-1040
Basic
14 mm
1040
Standalone
MS4800S-EB-014-1080
Basic
14 mm
1080
Standalone
MS4800S-EB-014-1120
Basic
14 mm
1120
Standalone
MS4800S-EB-014-1160
Basic
14 mm
1160
Standalone
MS4800S-EB-014-1200
Basic
14 mm
1200
Standalone
MS4800S-EB-014-1240
Basic
14 mm
1240
Standalone
MS4800S-EB-014-1280
Basic
14 mm
1280
Standalone
MS4800S-EB-014-1320
Basic
14 mm
1320
Standalone
MS4800S-EB-014-1360
Basic
14 mm
1360
Standalone
MS4800S-EB-014-1400
Basic
14 mm
1400
Standalone
MS4800S-EB-014-1440
Basic
14 mm
1440
Standalone
MS4800S-EB-014-1480
Basic
14 mm
1480
Standalone
MS4800S-EB-014-1520
Basic
14 mm
1520
Standalone
MS4800S-EB-014-1560
Basic
14 mm
1560
Standalone
MS4800S-EB-014-1600
Basic
14 mm
1600
Standalone
MS4800S-EB-014-1640
Basic
14 mm
1640
Standalone
MS4800S-EB-014-1680
Basic
14 mm
1680
Standalone
MS4800S-EB-014-1720
Basic
14 mm
1720
Standalone
MS4800S-EB-014-1760
Basic
14 mm
1760
Standalone
MS4800S-EB-014-1800
Basic
14 mm
1800
Standalone
List of models
Section 15-8
Advanced version, 14 mm resolution, Standalone unit without Flex connection
Type Name
Version
Resolution
[mm]
Length
[mm]
Operation
MS4800S-EA-014-0280
Advanced
14 mm
280
Standalone
MS4800S-EA-014-0320
Advanced
14 mm
320
Standalone
MS4800S-EA-014-0360
Advanced
14 mm
360
Standalone
MS4800S-EA-014-0400
Advanced
14 mm
400
Standalone
MS4800S-EA-014-0440
Advanced
14 mm
440
Standalone
MS4800S-EA-014-0480
Advanced
14 mm
480
Standalone
MS4800S-EA-014-0520
Advanced
14 mm
520
Standalone
MS4800S-EA-014-0560
Advanced
14 mm
560
Standalone
MS4800S-EA-014-0600
Advanced
14 mm
600
Standalone
MS4800S-EA-014-0640
Advanced
14 mm
640
Standalone
MS4800S-EA-014-0680
Advanced
14 mm
680
Standalone
MS4800S-EA-014-0720
Advanced
14 mm
720
Standalone
MS4800S-EA-014-0760
Advanced
14 mm
760
Standalone
MS4800S-EA-014-0800
Advanced
14 mm
800
Standalone
MS4800S-EA-014-0840
Advanced
14 mm
840
Standalone
MS4800S-EA-014-0880
Advanced
14 mm
880
Standalone
MS4800S-EA-014-0920
Advanced
14 mm
920
Standalone
MS4800S-EA-014-0960
Advanced
14 mm
960
Standalone
MS4800S-EA-014-1000
Advanced
14 mm
1000
Standalone
MS4800S-EA-014-1040
Advanced
14 mm
1040
Standalone
MS4800S-EA-014-1080
Advanced
14 mm
1080
Standalone
MS4800S-EA-014-1120
Advanced
14 mm
1120
Standalone
MS4800S-EA-014-1160
Advanced
14 mm
1160
Standalone
MS4800S-EA-014-1200
Advanced
14 mm
1200
Standalone
MS4800S-EA-014-1240
Advanced
14 mm
1240
Standalone
MS4800S-EA-014-1280
Advanced
14 mm
1280
Standalone
MS4800S-EA-014-1320
Advanced
14 mm
1320
Standalone
MS4800S-EA-014-1360
Advanced
14 mm
1360
Standalone
MS4800S-EA-014-1400
Advanced
14 mm
1400
Standalone
MS4800S-EA-014-1440
Advanced
14 mm
1440
Standalone
MS4800S-EA-014-1480
Advanced
14 mm
1480
Standalone
MS4800S-EA-014-1520
Advanced
14 mm
1520
Standalone
MS4800S-EA-014-1560
Advanced
14 mm
1560
Standalone
MS4800S-EA-014-1600
Advanced
14 mm
1600
Standalone
MS4800S-EA-014-1640
Advanced
14 mm
1640
Standalone
MS4800S-EA-014-1680
Advanced
14 mm
1680
Standalone
MS4800S-EA-014-1720
Advanced
14 mm
1720
Standalone
MS4800S-EA-014-1760
Advanced
14 mm
1760
Standalone
MS4800S-EA-014-1800
Advanced
14 mm
1800
Standalone
List of models
Section 15-8
Basic version, 30 mm resolution, Standalone unit without Flex connection
Type Name
Version
Resolution
[mm]
Length
[mm]
Operation
MS4800S-EB-030-0280
Basic
30 mm
280
Standalone
MS4800S-EB-030-0320
Basic
30 mm
320
Standalone
MS4800S-EB-030-0360
Basic
30 mm
360
Standalone
MS4800S-EB-030-0400
Basic
30 mm
400
Standalone
MS4800S-EB-030-0440
Basic
30 mm
440
Standalone
MS4800S-EB-030-0480
Basic
30 mm
480
Standalone
MS4800S-EB-030-0520
Basic
30 mm
520
Standalone
MS4800S-EB-030-0560
Basic
30 mm
560
Standalone
MS4800S-EB-030-0600
Basic
30 mm
600
Standalone
MS4800S-EB-030-0640
Basic
30 mm
640
Standalone
MS4800S-EB-030-0680
Basic
30 mm
680
Standalone
MS4800S-EB-030-0720
Basic
30 mm
720
Standalone
MS4800S-EB-030-0760
Basic
30 mm
760
Standalone
MS4800S-EB-030-0800
Basic
30 mm
800
Standalone
MS4800S-EB-030-0840
Basic
30 mm
840
Standalone
MS4800S-EB-030-0880
Basic
30 mm
880
Standalone
MS4800S-EB-030-0920
Basic
30 mm
920
Standalone
MS4800S-EB-030-0960
Basic
30 mm
960
Standalone
MS4800S-EB-030-1000
Basic
30 mm
1000
Standalone
MS4800S-EB-030-1040
Basic
30 mm
1040
Standalone
MS4800S-EB-030-1080
Basic
30 mm
1080
Standalone
MS4800S-EB-030-1120
Basic
30 mm
1120
Standalone
MS4800S-EB-030-1160
Basic
30 mm
1160
Standalone
MS4800S-EB-030-1200
Basic
30 mm
1200
Standalone
MS4800S-EB-030-1240
Basic
30 mm
1240
Standalone
MS4800S-EB-030-1280
Basic
30 mm
1280
Standalone
MS4800S-EB-030-1320
Basic
30 mm
1320
Standalone
MS4800S-EB-030-1360
Basic
30 mm
1360
Standalone
MS4800S-EB-030-1400
Basic
30 mm
1400
Standalone
MS4800S-EB-030-1440
Basic
30 mm
1440
Standalone
MS4800S-EB-030-1480
Basic
30 mm
1480
Standalone
MS4800S-EB-030-1520
Basic
30 mm
1520
Standalone
MS4800S-EB-030-1560
Basic
30 mm
1560
Standalone
MS4800S-EB-030-1600
Basic
30 mm
1600
Standalone
MS4800S-EB-030-1640
Basic
30 mm
1640
Standalone
MS4800S-EB-030-1680
Basic
30 mm
1680
Standalone
MS4800S-EB-030-1720
Basic
30 mm
1720
Standalone
MS4800S-EB-030-1760
Basic
30 mm
1760
Standalone
MS4800S-EB-030-1800
Basic
30 mm
1800
Standalone
MS4800S-EB-030-1840
Basic
30 mm
1840
Standalone
MS4800S-EB-030-1880
Basic
30 mm
1880
Standalone
MS4800S-EB-030-1920
Basic
30 mm
1920
Standalone
MS4800S-EB-030-1960
Basic
30 mm
1960
Standalone
MS4800S-EB-030-2000
Basic
30 mm
2000
Standalone
MS4800S-EB-030-2040
Basic
30 mm
2040
Standalone
MS4800S-EB-030-2080
Basic
30 mm
2080
Standalone
MS4800S-EB-030-2120
Basic
30 mm
2120
Standalone
List of models
Section 15-8
Advanced version, 30 mm resolution, Standalone unit without Flex connection
Type Name
Version
Resolution
[mm]
Length
[mm]
Operation
MS4800S-EA-030-0280
Advanced
30 mm
280
Standalone
MS4800S-EA-030-0320
Advanced
30 mm
320
Standalone
MS4800S-EA-030-0360
Advanced
30 mm
360
Standalone
MS4800S-EA-030-0400
Advanced
30 mm
400
Standalone
MS4800S-EA-030-0440
Advanced
30 mm
440
Standalone
MS4800S-EA-030-0480
Advanced
30 mm
480
Standalone
MS4800S-EA-030-0520
Advanced
30 mm
520
Standalone
MS4800S-EA-030-0560
Advanced
30 mm
560
Standalone
MS4800S-EA-030-0600
Advanced
30 mm
600
Standalone
MS4800S-EA-030-0640
Advanced
30 mm
640
Standalone
MS4800S-EA-030-0680
Advanced
30 mm
680
Standalone
MS4800S-EA-030-0720
Advanced
30 mm
720
Standalone
MS4800S-EA-030-0760
Advanced
30 mm
760
Standalone
MS4800S-EA-030-0800
Advanced
30 mm
800
Standalone
MS4800S-EA-030-0840
Advanced
30 mm
840
Standalone
MS4800S-EA-030-0880
Advanced
30 mm
880
Standalone
MS4800S-EA-030-0920
Advanced
30 mm
920
Standalone
MS4800S-EA-030-0960
Advanced
30 mm
960
Standalone
MS4800S-EA-030-1000
Advanced
30 mm
1000
Standalone
MS4800S-EA-030-1040
Advanced
30 mm
1040
Standalone
MS4800S-EA-030-1080
Advanced
30 mm
1080
Standalone
MS4800S-EA-030-1120
Advanced
30 mm
1120
Standalone
MS4800S-EA-030-1160
Advanced
30 mm
1160
Standalone
MS4800S-EA-030-1200
Advanced
30 mm
1200
Standalone
MS4800S-EA-030-1240
Advanced
30 mm
1240
Standalone
MS4800S-EA-030-1280
Advanced
30 mm
1280
Standalone
MS4800S-EA-030-1320
Advanced
30 mm
1320
Standalone
MS4800S-EA-030-1360
Advanced
30 mm
1360
Standalone
MS4800S-EA-030-1400
Advanced
30 mm
1400
Standalone
MS4800S-EA-030-1440
Advanced
30 mm
1440
Standalone
MS4800S-EA-030-1480
Advanced
30 mm
1480
Standalone
MS4800S-EA-030-1520
Advanced
30 mm
1520
Standalone
MS4800S-EA-030-1560
Advanced
30 mm
1560
Standalone
MS4800S-EA-030-1600
Advanced
30 mm
1600
Standalone
MS4800S-EA-030-1640
Advanced
30 mm
1640
Standalone
MS4800S-EA-030-1680
Advanced
30 mm
1680
Standalone
MS4800S-EA-030-1720
Advanced
30 mm
1720
Standalone
MS4800S-EA-030-1760
Advanced
30 mm
1760
Standalone
MS4800S-EA-030-1800
Advanced
30 mm
1800
Standalone
MS4800S-EA-030-1840
Advanced
30 mm
1840
Standalone
MS4800S-EA-030-1880
Advanced
30 mm
1880
Standalone
MS4800S-EA-030-1920
Advanced
30 mm
1920
Standalone
MS4800S-EA-030-1960
Advanced
30 mm
1960
Standalone
MS4800S-EA-030-2000
Advanced
30 mm
2000
Standalone
MS4800S-EA-030-2040
Advanced
30 mm
2040
Standalone
MS4800S-EA-030-2080
Advanced
30 mm
2080
Standalone
MS4800S-EA-030-2120
Advanced
30 mm
2120
Standalone
List of models
Section 15-8
Basic version, 14 mm resolution, Cascadable, Master unit
Type Name
Version
Resolution
[mm]
Length
[mm]
Operation
MS4800FS-EB-014-0280
Basic
14 mm
280
Master
MS4800FS-EB-014-0320
Basic
14 mm
320
Master
MS4800FS-EB-014-0360
Basic
14 mm
360
Master
MS4800FS-EB-014-0400
Basic
14 mm
400
Master
MS4800FS-EB-014-0440
Basic
14 mm
440
Master
MS4800FS-EB-014-0480
Basic
14 mm
480
Master
MS4800FS-EB-014-0520
Basic
14 mm
520
Master
MS4800FS-EB-014-0560
Basic
14 mm
560
Master
MS4800FS-EB-014-0600
Basic
14 mm
600
Master
MS4800FS-EB-014-0640
Basic
14 mm
640
Master
MS4800FS-EB-014-0680
Basic
14 mm
680
Master
MS4800FS-EB-014-0720
Basic
14 mm
720
Master
MS4800FS-EB-014-0760
Basic
14 mm
760
Master
MS4800FS-EB-014-0800
Basic
14 mm
800
Master
MS4800FS-EB-014-0840
Basic
14 mm
840
Master
MS4800FS-EB-014-0880
Basic
14 mm
880
Master
MS4800FS-EB-014-0920
Basic
14 mm
920
Master
MS4800FS-EB-014-0960
Basic
14 mm
960
Master
MS4800FS-EB-014-1000
Basic
14 mm
1000
Master
MS4800FS-EB-014-1040
Basic
14 mm
1040
Master
MS4800FS-EB-014-1080
Basic
14 mm
1080
Master
MS4800FS-EB-014-1120
Basic
14 mm
1120
Master
MS4800FS-EB-014-1160
Basic
14 mm
1160
Master
MS4800FS-EB-014-1200
Basic
14 mm
1200
Master
MS4800FS-EB-014-1240
Basic
14 mm
1240
Master
MS4800FS-EB-014-1280
Basic
14 mm
1280
Master
MS4800FS-EB-014-1320
Basic
14 mm
1320
Master
MS4800FS-EB-014-1360
Basic
14 mm
1360
Master
MS4800FS-EB-014-1400
Basic
14 mm
1400
Master
MS4800FS-EB-014-1440
Basic
14 mm
1440
Master
MS4800FS-EB-014-1480
Basic
14 mm
1480
Master
MS4800FS-EB-014-1520
Basic
14 mm
1520
Master
MS4800FS-EB-014-1560
Basic
14 mm
1560
Master
MS4800FS-EB-014-1600
Basic
14 mm
1600
Master
MS4800FS-EB-014-1640
Basic
14 mm
1640
Master
MS4800FS-EB-014-1680
Basic
14 mm
1680
Master
MS4800FS-EB-014-1720
Basic
14 mm
1720
Master
MS4800FS-EB-014-1760
Basic
14 mm
1760
Master
MS4800FS-EB-014-1800
Basic
14 mm
1800
Master
List of models
Section 15-8
Advanced version, 14 mm resolution, Cascadable, Master unit
Type Name
Version
Resolution
[mm]
Length
[mm]
Operation
MS4800FS-EA-014-0280
Advanced
14 mm
280
Master
MS4800FS-EA-014-0320
Advanced
14 mm
320
Master
MS4800FS-EA-014-0360
Advanced
14 mm
360
Master
MS4800FS-EA-014-0400
Advanced
14 mm
400
Master
MS4800FS-EA-014-0440
Advanced
14 mm
440
Master
MS4800FS-EA-014-0480
Advanced
14 mm
480
Master
MS4800FS-EA-014-0520
Advanced
14 mm
520
Master
MS4800FS-EA-014-0560
Advanced
14 mm
560
Master
MS4800FS-EA-014-0600
Advanced
14 mm
600
Master
MS4800FS-EA-014-0640
Advanced
14 mm
640
Master
MS4800FS-EA-014-0680
Advanced
14 mm
680
Master
MS4800FS-EA-014-0720
Advanced
14 mm
720
Master
MS4800FS-EA-014-0760
Advanced
14 mm
760
Master
MS4800FS-EA-014-0800
Advanced
14 mm
800
Master
MS4800FS-EA-014-0840
Advanced
14 mm
840
Master
MS4800FS-EA-014-0880
Advanced
14 mm
880
Master
MS4800FS-EA-014-0920
Advanced
14 mm
920
Master
MS4800FS-EA-014-0960
Advanced
14 mm
960
Master
MS4800FS-EA-014-1000
Advanced
14 mm
1000
Master
MS4800FS-EA-014-1040
Advanced
14 mm
1040
Master
MS4800FS-EA-014-1080
Advanced
14 mm
1080
Master
MS4800FS-EA-014-1120
Advanced
14 mm
1120
Master
MS4800FS-EA-014-1160
Advanced
14 mm
1160
Master
MS4800FS-EA-014-1200
Advanced
14 mm
1200
Master
MS4800FS-EA-014-1240
Advanced
14 mm
1240
Master
MS4800FS-EA-014-1280
Advanced
14 mm
1280
Master
MS4800FS-EA-014-1320
Advanced
14 mm
1320
Master
MS4800FS-EA-014-1360
Advanced
14 mm
1360
Master
MS4800FS-EA-014-1400
Advanced
14 mm
1400
Master
MS4800FS-EA-014-1440
Advanced
14 mm
1440
Master
MS4800FS-EA-014-1480
Advanced
14 mm
1480
Master
MS4800FS-EA-014-1520
Advanced
14 mm
1520
Master
MS4800FS-EA-014-1560
Advanced
14 mm
1560
Master
MS4800FS-EA-014-1600
Advanced
14 mm
1600
Master
MS4800FS-EA-014-1640
Advanced
14 mm
1640
Master
MS4800FS-EA-014-1680
Advanced
14 mm
1680
Master
MS4800FS-EA-014-1720
Advanced
14 mm
1720
Master
MS4800FS-EA-014-1760
Advanced
14 mm
1760
Master
MS4800FS-EA-014-1800
Advanced
14 mm
1800
Master
List of models
Section 15-8
Slave operation model, 14 mm resolution, Cascadable, Slave unit
Type Name
Version
Resolution
[mm]
Length
[mm]
Operation
MS4800F-E-014-0240
n.a.
14 mm
240
Slave
MS4800F-E-014-0280
n.a.
14 mm
280
Slave
MS4800F-E-014-0320
n.a.
14 mm
320
Slave
MS4800F-E-014-0360
n.a.
14 mm
360
Slave
MS4800F-E-014-0400
n.a.
14 mm
400
Slave
MS4800F-E-014-0440
n.a.
14 mm
440
Slave
MS4800F-E-014-0480
n.a.
14 mm
480
Slave
MS4800F-E-014-0520
n.a.
14 mm
520
Slave
MS4800F-E-014-0560
n.a.
14 mm
560
Slave
MS4800F-E-014-0600
n.a.
14 mm
600
Slave
MS4800F-E-014-0640
n.a.
14 mm
640
Slave
MS4800F-E-014-0680
n.a.
14 mm
680
Slave
MS4800F-E-014-0720
n.a.
14 mm
720
Slave
MS4800F-E-014-0760
n.a.
14 mm
760
Slave
MS4800F-E-014-0800
n.a.
14 mm
800
Slave
MS4800F-E-014-0840
n.a.
14 mm
840
Slave
MS4800F-E-014-0880
n.a.
14 mm
880
Slave
MS4800F-E-014-0920
n.a.
14 mm
920
Slave
MS4800F-E-014-0960
n.a.
14 mm
960
Slave
MS4800F-E-014-1000
n.a.
14 mm
1000
Slave
MS4800F-E-014-1040
n.a.
14 mm
1040
Slave
MS4800F-E-014-1080
n.a.
14 mm
1080
Slave
MS4800F-E-014-1120
n.a.
14 mm
1120
Slave
MS4800F-E-014-1160
n.a.
14 mm
1160
Slave
MS4800F-E-014-1200
n.a.
14 mm
1200
Slave
MS4800F-E-014-1240
n.a.
14 mm
1240
Slave
MS4800F-E-014-1280
n.a.
14 mm
1280
Slave
List of models
Section 15-8
Basic version, 30 mm resolution, Cascadable, Master unit
Type Name
Version
Resolution
[mm]
Length
[mm]
Operation
MS4800FS-EB-030-0280
Basic
30 mm
280
Master
MS4800FS-EB-030-0320
Basic
30 mm
320
Master
MS4800FS-EB-030-0360
Basic
30 mm
360
Master
MS4800FS-EB-030-0400
Basic
30 mm
400
Master
MS4800FS-EB-030-0440
Basic
30 mm
440
Master
MS4800FS-EB-030-0480
Basic
30 mm
480
Master
MS4800FS-EB-030-0520
Basic
30 mm
520
Master
MS4800FS-EB-030-0560
Basic
30 mm
560
Master
MS4800FS-EB-030-0600
Basic
30 mm
600
Master
MS4800FS-EB-030-0640
Basic
30 mm
640
Master
MS4800FS-EB-030-0680
Basic
30 mm
680
Master
MS4800FS-EB-030-0720
Basic
30 mm
720
Master
MS4800FS-EB-030-0760
Basic
30 mm
760
Master
MS4800FS-EB-030-0800
Basic
30 mm
800
Master
MS4800FS-EB-030-0840
Basic
30 mm
840
Master
MS4800FS-EB-030-0880
Basic
30 mm
880
Master
MS4800FS-EB-030-0920
Basic
30 mm
920
Master
MS4800FS-EB-030-0960
Basic
30 mm
960
Master
MS4800FS-EB-030-1000
Basic
30 mm
1000
Master
MS4800FS-EB-030-1040
Basic
30 mm
1040
Master
MS4800FS-EB-030-1080
Basic
30 mm
1080
Master
MS4800FS-EB-030-1120
Basic
30 mm
1120
Master
MS4800FS-EB-030-1160
Basic
30 mm
1160
Master
MS4800FS-EB-030-1200
Basic
30 mm
1200
Master
MS4800FS-EB-030-1240
Basic
30 mm
1240
Master
MS4800FS-EB-030-1280
Basic
30 mm
1280
Master
MS4800FS-EB-030-1320
Basic
30 mm
1320
Master
MS4800FS-EB-030-1360
Basic
30 mm
1360
Master
MS4800FS-EB-030-1400
Basic
30 mm
1400
Master
MS4800FS-EB-030-1440
Basic
30 mm
1440
Master
MS4800FS-EB-030-1480
Basic
30 mm
1480
Master
MS4800FS-EB-030-1520
Basic
30 mm
1520
Master
MS4800FS-EB-030-1560
Basic
30 mm
1560
Master
MS4800FS-EB-030-1600
Basic
30 mm
1600
Master
MS4800FS-EB-030-1640
Basic
30 mm
1640
Master
MS4800FS-EB-030-1680
Basic
30 mm
1680
Master
MS4800FS-EB-030-1720
Basic
30 mm
1720
Master
MS4800FS-EB-030-1760
Basic
30 mm
1760
Master
MS4800FS-EB-030-1800
Basic
30 mm
1800
Master
MS4800FS-EB-030-1840
Basic
30 mm
1840
Master
MS4800FS-EB-030-1880
Basic
30 mm
1880
Master
MS4800FS-EB-030-1920
Basic
30 mm
1920
Master
MS4800FS-EB-030-1960
Basic
30 mm
1960
Master
MS4800FS-EB-030-2000
Basic
30 mm
2000
Master
MS4800FS-EB-030-2040
Basic
30 mm
2040
Master
MS4800FS-EB-030-2080
Basic
30 mm
2080
Master
MS4800FS-EB-030-2120
Basic
30 mm
2120
Master
List of models
Section 15-8
Advanced version, 30 mm resolution, Cascadable, Master unit
Type Name
Version
Resolution
[mm]
Length
[mm]
Operation
MS4800FS-EA-030-0280
Advanced
30 mm
280
Master
MS4800FS-EA-030-0320
Advanced
30 mm
320
Master
MS4800FS-EA-030-0360
Advanced
30 mm
360
Master
MS4800FS-EA-030-0400
Advanced
30 mm
400
Master
MS4800FS-EA-030-0440
Advanced
30 mm
440
Master
MS4800FS-EA-030-0480
Advanced
30 mm
480
Master
MS4800FS-EA-030-0520
Advanced
30 mm
520
Master
MS4800FS-EA-030-0560
Advanced
30 mm
560
Master
MS4800FS-EA-030-0600
Advanced
30 mm
600
Master
MS4800FS-EA-030-0640
Advanced
30 mm
640
Master
MS4800FS-EA-030-0680
Advanced
30 mm
680
Master
MS4800FS-EA-030-0720
Advanced
30 mm
720
Master
MS4800FS-EA-030-0760
Advanced
30 mm
760
Master
MS4800FS-EA-030-0800
Advanced
30 mm
800
Master
MS4800FS-EA-030-0840
Advanced
30 mm
840
Master
MS4800FS-EA-030-0880
Advanced
30 mm
880
Master
MS4800FS-EA-030-0920
Advanced
30 mm
920
Master
MS4800FS-EA-030-0960
Advanced
30 mm
960
Master
MS4800FS-EA-030-1000
Advanced
30 mm
1000
Master
MS4800FS-EA-030-1040
Advanced
30 mm
1040
Master
MS4800FS-EA-030-1080
Advanced
30 mm
1080
Master
MS4800FS-EA-030-1120
Advanced
30 mm
1120
Master
MS4800FS-EA-030-1160
Advanced
30 mm
1160
Master
MS4800FS-EA-030-1200
Advanced
30 mm
1200
Master
MS4800FS-EA-030-1240
Advanced
30 mm
1240
Master
MS4800FS-EA-030-1280
Advanced
30 mm
1280
Master
MS4800FS-EA-030-1320
Advanced
30 mm
1320
Master
MS4800FS-EA-030-1360
Advanced
30 mm
1360
Master
MS4800FS-EA-030-1400
Advanced
30 mm
1400
Master
MS4800FS-EA-030-1440
Advanced
30 mm
1440
Master
MS4800FS-EA-030-1480
Advanced
30 mm
1480
Master
MS4800FS-EA-030-1520
Advanced
30 mm
1520
Master
MS4800FS-EA-030-1560
Advanced
30 mm
1560
Master
MS4800FS-EA-030-1600
Advanced
30 mm
1600
Master
MS4800FS-EA-030-1640
Advanced
30 mm
1640
Master
MS4800FS-EA-030-1680
Advanced
30 mm
1680
Master
MS4800FS-EA-030-1720
Advanced
30 mm
1720
Master
MS4800FS-EA-030-1760
Advanced
30 mm
1760
Master
MS4800FS-EA-030-1800
Advanced
30 mm
1800
Master
MS4800FS-EA-030-1840
Advanced
30 mm
1840
Master
MS4800FS-EA-030-1880
Advanced
30 mm
1880
Master
MS4800FS-EA-030-1920
Advanced
30 mm
1920
Master
MS4800FS-EA-030-1960
Advanced
30 mm
1960
Master
MS4800FS-EA-030-2000
Advanced
30 mm
2000
Master
MS4800FS-EA-030-2040
Advanced
30 mm
2040
Master
MS4800FS-EA-030-2080
Advanced
30 mm
2080
Master
MS4800FS-EA-030-2120
Advanced
30 mm
2120
Master
List of models
Section 15-8
Slave operation model, 30 mm resolution, Cascadable, Slave unit
Type Name
Version
Resolution
[mm]
Length
[mm]
Operation
MS4800F-E-030-0280
n.a.
30 mm
280
Slave
MS4800F-E-030-0320
n.a.
30 mm
320
Slave
MS4800F-E-030-0360
n.a.
30 mm
360
Slave
MS4800F-E-030-0400
n.a.
30 mm
400
Slave
MS4800F-E-030-0440
n.a.
30 mm
440
Slave
MS4800F-E-030-0480
n.a.
30 mm
480
Slave
MS4800F-E-030-0520
n.a.
30 mm
520
Slave
MS4800F-E-030-0560
n.a.
30 mm
560
Slave
MS4800F-E-030-0600
n.a.
30 mm
600
Slave
MS4800F-E-030-0640
n.a.
30 mm
640
Slave
MS4800F-E-030-0680
n.a.
30 mm
680
Slave
MS4800F-E-030-0720
n.a.
30 mm
720
Slave
MS4800F-E-030-0760
n.a.
30 mm
760
Slave
MS4800F-E-030-0800
n.a.
30 mm
800
Slave
MS4800F-E-030-0840
n.a.
30 mm
840
Slave
MS4800F-E-030-0880
n.a.
30 mm
880
Slave
MS4800F-E-030-0920
n.a.
30 mm
920
Slave
MS4800F-E-030-0960
n.a.
30 mm
960
Slave
MS4800F-E-030-1000
n.a.
30 mm
1000
Slave
MS4800F-E-030-1040
n.a.
30 mm
1040
Slave
MS4800F-E-030-1080
n.a.
30 mm
1080
Slave
MS4800F-E-030-1120
n.a.
30 mm
1120
Slave
MS4800F-E-030-1160
n.a.
30 mm
1160
Slave
MS4800F-E-030-1200
n.a.
30 mm
1200
Slave
MS4800F-E-030-1240
n.a.
30 mm
1240
Slave
MS4800F-E-030-1280
n.a.
30 mm
1280
Slave
MS4800F-E-030-1320
n.a.
30 mm
1320
Slave
MS4800F-E-030-1360
n.a.
30 mm
1360
Slave
MS4800F-E-030-1400
n.a.
30 mm
1400
Slave
MS4800F-E-030-1440
n.a.
30 mm
1440
Slave
MS4800F-E-030-1480
n.a.
30 mm
1480
Slave
MS4800F-E-030-1520
n.a.
30 mm
1520
Slave
MS4800F-E-030-1560
n.a.
30 mm
1560
Slave
MS4800F-E-030-1600
n.a.
30 mm
1600
Slave
MS4800F-E-030-1640
n.a.
30 mm
1640
Slave
MS4800F-E-030-1680
n.a.
30 mm
1680
Slave
MS4800F-E-030-1720
n.a.
30 mm
1720
Slave
MS4800F-E-030-1760
n.a.
30 mm
1760
Slave
MS4800F-E-030-1800
n.a.
30 mm
1800
Slave
MS4800F-E-030-1840
n.a.
30 mm
1840
Slave
MS4800F-E-030-1880
n.a.
30 mm
1880
Slave
MS4800F-E-030-1920
n.a.
30 mm
1920
Slave
MS4800F-E-030-1960
n.a.
30 mm
1960
Slave
MS4800F-E-030-2000
n.a.
30 mm
2000
Slave
MS4800F-E-030-2040
n.a.
30 mm
2040
Slave
MS4800F-E-030-2080
n.a.
30 mm
2080
Slave
MS4800F-E-030-2120
n.a.
30 mm
2120
Slave
15-9-1 Muting controller RM-6
15-9-2 Safety Relay Units
Family
Type Name
Configuration
G9SB
G9SB-200-D
DPST-NO
G9SB-301-D
3PST-NO
G9SA
G9SA-301
3PST-NO
G9SA-501
5PST-NO
G9SA-321-T075
3PST-NO, Time del. 7,5 s
G9SA-321-T15
3PST-NO, Time del. 15 s
G9SA-321-T30
3PST-NO, Time del. 30 s
G9SX
G9SX-BC202-RT
2 Safe Outputs
G9SX-BC202-RC
2 Safe Outputs
G9SX-AD322-T15-RT
3 Safe Outputs, Time del. 15 s
G9SX-AD322-T15-RC
3 Safe Outputs, Time del. 15 s
G9SX-AD322-T150-RT
3 Safe Outputs, Time del. 150 s
G9SX-AD322-T150-RC
3 Safe Outputs, Time del. 150 s
G9SX-ADA222-T15-RT
2 Safe Outputs, Time del. 15 s
G9SX-ADA222-T15-RC
2 Safe Outputs, Time del. 15 s
G9SX-ADA222-T150-RT
2 Safe Outputs, Time del. 150 s
G9SX-ADA222-T150-RC
2 Safe Outputs, Time del. 150 s
DeviceNetSafety
NE1A-SCPU01
16 In, 8 Out, Safety Master
NE1A-SCPU02
40 In, 8 Out, Safety Master
Safety Controller
NE1A-SCPU01L
16 In, 8 Out
NE1A-SCPU02L
40 In, 8 Out
Z1
Z2
S11
S12
B1
B2
X1
X2
13
14
23
24
A1
A2
31
32
Status
RM-6
S3
S1
S4
S2
0VDC
RET
+VDC
-RS
+RS
Lamp
PE
Shield
22.5
0.89
99
3.90
99
3.90
114
4.49
15-9-3 Standard Cables
15-9-4 Interconnect Cables
15-9-5 Explosion proof enclosure
System complies:
EN50014 (1997) incl. A1-A2 (1997)
EN50018 (2000) incl. A1 (2002)
EN50281-1-1 (1998) incl. A1 (2002)
UL certificate with US and Canadian directives
Receiver Cables
F39-JMR-10M
Receiver Cable, 10 m length
F39-JMR-15M
Receiver Cable, 15 m length
F39-JMR-30M
Receiver Cable, 30 m length
Transmitter Cables
F39-JMT-10M
Transmitter Cable, 10 m length
F39-JMT-15M
Transmitter Cable, 15 m length
F39-JMT-30M
Transmitter Cable, 30 m length
Receiver Cables
F39-JMCR-03M
Receiver Interconnect Cable, 0,3 m length
F39-JMCR-05M
Receiver Interconnect Cable, 0,5 m length
F39-JMCR-1M
Receiver Interconnect Cable, 1,0 m length
F39-JMCR-2M
Receiver Interconnect Cable, 2,0 m length
F39-JMCR-3M
Receiver Interconnect Cable, 3,0 m length
F39-JMCR-5M
Receiver Interconnect Cable, 5,0 m length
F39-JMCR-10M
Receiver Interconnect Cable, 10 m length
Transmitter Cables
F39-JMCT-03M
Transmitter Interconnect Cable, 0,3 m length
F39-JMCT-05M
Transmitter Interconnect Cable, 0,5 m length
F39-JMCT-1M
Transmitter Interconnect Cable, 1,0 m length
F39-JMCT-2M
Transmitter Interconnect Cable, 2,0 m length
F39-JMCT-3M
Transmitter Interconnect Cable, 3,0 m length
F39-JMCT-5M
Transmitter Interconnect Cable, 5,0 m length
F39-JMCT-10M
Transmitter Interconnect Cable, 10 m length
F39-EXPF-AX300
Explosion proof housing for
MS4800-014-0320
MS4800-030-0320
F39-EXPF-AX600
Explosion proof housing for
MS4800-030-0640
F39-EXPF-AX900
Explosion proof housing for
MS4800-030-0960
F39-EXPF-AX1200
Explosion proof housing for
MS4800-030-1240
15-9-6 IP67-Enclosure for MS4800 (standalone)
Please use the following coding to order the IP67-enclosures:
F39-EM67-XXXX where XXXX is the length of the protection field.
15-9-7 IP67-Enclosure for MS4800FS (cascaded)
Please use the following coding to order the IP67-enclosures:
F39-EM67FS-XXXX where XXXX is the length of the protection field.
15-9-8 Welding protection shield (Sputter protection)
Please use the following coding to order the welding protection shield (Lexan
front window):
F39-EMWS-XXXX where XXXX is the length of the protection field.
Upon completion of power-up, the ESPE will enter the MACHINE RUN state
as soon as the detection zone is clear of opaque objects of the specified
size.
Detection Zone
The IR light sensing area of the ESPE. When a specified test piece enters
this area then the ESPE must detect its presence and set its safety outputs
to the OFF-state.
Electro-Sensitive
Protective Equipment
(ESPE)
An assembly of devices and/or components working together for protective
tripping or presence sensing purposes and comprising as a minimum:
• a sensing device
• controlling/monitoring devices
• output signal switching devices
LOCKOUT condition
When the ESPE detects a fault, it transitions to this state. The OSSD will be
held to the OFF-state and the ESPE will not attempt to leave this state with-
out performing a comprehensive power up self-test. A power-up self test will
be initiated by either cycling the ESPE power or by a Start signal transition.
MACHINE RUN
When the ESPE is in this state, the two OSSD are both active. In this state
the Green MACHINE RUN LED is on, the red MACHINE STOP LED is off
and the Yellow INTERLOCK LED is off.
MACHINE STOP
When the ESPE is in this state, the two OSSD are both inactive. In this state
the Green MACHINE RUN LED is off, the Red MACHINE STOP LED is on.
OFF-STATE
The state in which the output circuit is interrupted and does not permit the
flow of current.
ON-STATE
The state in which the output circuit is completed and permits the flow of cur-
rent.
Output Signal
Switching Device (OSSD)
The safety output of the ESPE that is used to enable and disable the
guarded machine.
Response Time
The maximum amount of time required for the ESPE to set its OSSD outputs
to the OFF-state once the detection zone is blocked by an opaque object of
the specified size.
Start INTERLOCK
Upon completion of power-up, the ESPE must go to the "INTERLOCK" state.
A Start signal transition must occur before going to MACHINE RUN for the
first time. Once the first Start condition has been met, the ESPE will operate
in the Automatic Start mode.
Start/Restart INTERLOCK
The ESPE will go into the INTERLOCK state upon completion of power-up
and during zone violations which causes a transition to the MACHINE STOP
state. A Start signal transition must occur before returning to MACHINE RUN
following any transition to MACHINE STOP.
Diagnostics and Troubleshooting
17-1 Transmitter Diagnostic information and troubleshooting
The transmitter has one Yellow LED to show the operational status.
If the yellow LED is off:
1.
Verify the cable is connected.
2.
Verify the power supply is within limits (+24 V ±20%)
3.
If this does not solve the problem, please contact your local Omron distrib-
utor or the European Repair Center.
If the yellow LED is blinking:
1.
Verify the power supply is within limits (+24 V ±20%)
2.
If this does not solve the problem, please contact your local Omron distrib-
utor or the European Repair Center.
17-2 Receiver Diagnostic Information
The receiver first segment has a set of LEDs to indicate diagnostic codes. The
LEDs will only indicate fault codes, when in the Fault state. In this state the
yellow INTERLOCK LED will be flashing and a row of 10 LEDs will display the
fault code.
17-3 Receiver Endcap Indicator Lights
Next group of 4
LED are on.
4th LED is off
First 3 LED are on.
Front View of
Receiver showing the
first 8 IBIs.
IBI LEDs are turned on to
indicate fault code 34,
which means OSSD 1
shorted to ground.
Interlock LED flashing on
receiver endcap
LED Color
Information shown
GREEN
The MS4800 is in the MACHINE RUN state.
RED
The MS4800 is in the MACHINE STOP state.
YELLOW INTERLOCK
The light curtain is waiting for the start button to be
pushed. If the LED is blinking, the light curtain is in an
alarm condition.
AMBER
The light curtain is operating in a Floating Blanking or
Fixed Blanking mode.
17-4 Receiver Troubleshooting
If the yellow INTERLOCK LED is blinking:
1.
Check the configuration for External Device Monitoring. If EDM is inactive
(via receiver dip switch), the input (pink wire) must be connected to system
ground. If EDM is active, the input must be connected to the normally
closed contacts of the control relays of the guarded machine or the monitor
terminal of the safety relay unit. Please refer to SECTION 11 Connection
to the Machine Control Circuit for an example.
2.
Make sure both selector switches in the receiver endcap have been set
properly and identically. Please refer to chapter 7-2 Operating mode selec-
tion for further information.
3.
Verify the power supply is within the specified limits (+24V ±20%).
4.
Verify the light curtain is properly connected to the control relays of the
guarded machine. If the light curtain is not intended to be connected to
control relays, see SECTION 12 Muting for further information.
5.
Verify the control relays are within operating limits of the safety outputs.
6.
Verify the cable lengths from the light curtain to the control relays are within
specified limits.
7.
If this does not solve the problem, please contact your local Omron distrib-
utor or the European Repair Center.
17-5 Receiver Error Codes
Code Group
Error Code
Description of Error Code
Corrective Action Needed
Configuration
Switch Faults
21
Invalid mode selection setting
Verify switch setting, see user manual
22
Configuration switch settings changed dur-
ing operation
Verify switch setting, see user manual
23
Configuration switch settings do not match
Verify switch setting, see user manual
24
Corrupted EEPROM configuration
Reset the system configuration to factory
defaults
26
Invalid scan code setting
Verify switch setting, see user manual
Safety Output
(OSSD) Faults
31
Safety outputs 1&2 are shorted together
Check and correct wiring of safety outputs 1
and 2
32
Safety output 1 is shorted to power
Check and correct wiring of safety outputs 1
33
Safety output 2 is shorted to power
Check and correct wiring of safety outputs 2
34
Safety output 1 is shorted to ground
Check and correct wiring of safety outputs 1
35
Safety output 2 is shorted to ground
Check and correct wiring of safety outputs 2
EDM Faults
41
EDM circuit did not open before transition to
MACHINE RUN state
Check and correct EDM wiring
42
EDM circuit did not open after transition to
MACHINE RUN state
Check and correct EDM wiring
43
EDM circuit was in wrong state during
power-up
Check and correct EDM wiring
44
EDM fault at power-up
Check start input wire or EDM function
selection
Controller Fault
50
Control logic fault
Please contact your local Omron distributor
or the European Repair Center
Setup Error
60
Possible crosstalk
Check and correct scan code setting
Muting Faults
70
General muting fault
Check wiring of unused mute sensors
71
Mute module enable and configuration
required:
Check mounting of mute sensors for correct
sequence
74
Mute lamp burned out or not connected
Check status of mute lamp
Receiver Error Codes
Section 17-5
Cascaded Sys-
tem Fault
80
Configuration Error
Please contact your local Omron distributor
or the European Repair Center
81
Second segment or mute module error
Check all cable connections. Please contact
your local Omron distributor or the Euro-
pean Repair Center
82
Third segment or mute module error
Check all cable connections. Please contact
your local Omron distributor or the Euro-
pean Repair Center
83
Fourth segment or mute module error
Check all cable connections. Please contact
your local Omron distributor or the Euro-
pean Repair Center
84
Mute module error
Check all cable connections to mute mod-
ule. Please contact your local Omron dis-
tributor or the European Repair Center
85
Configuration error
Please contact your local Omron distributor
or the European Repair Center
86
Second segment or mute module firmware
not compatible with first segment
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
87
Third segment or mute module firmware not
compatible with first segment
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
88
Fourth segment or mute module firmware
not compatible with first segment
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
89
Mute module firmware not compatible with
first segment
Replace with compatible component or
return system to Omron distributor or Euro-
pean Repair Center
90
Incorrect segment type in position two,
three or four
Confirm that all segments are of the same
type; either all transmitters or receivers
91
Segment 2 type does not match segment 1
type
Confirm that segment 2 is the same type
(transmitter or receiver) as segment 1
92
Segment 3 type does not match segment 1
type
Confirm that segment 3 is the same type
(transmitter or receiver) as segment 1
93
Segment 4 type does not match segment 1
type
Confirm that segment 4 is the same type
(transmitter or receiver) as segment 1
95
Error in flex segment or muting module dur-
ing operation
Check all flex connections, segments and
muting modules
96
Error in segment 2 during operation
Check connections to segment 2. Replace
segment 2 with known good segment 2.
Please contact your local Omron distributor
or the European Repair Center
97
Error in segment 3 during operation
Check connections to segment 3. Replace
segment 3 with known good segment 3.
Please contact your local Omron distributor
or the European Repair Center
98
Error in segment 4 during operation
Check connections to segment 4. Replace
segment 4 with known good segment 4.
Please contact your local Omron distributor
or the European Repair Center
100
Number of segments in system has been
reduced (changed)
Segment count is less than original configu-
ration. Add required segment(s) or program
system for current configuration
101
Too many flex nodes or muting modules in
the flex bus
Make sure of total of 4 segments with only
one muting module.
Code Group
Error Code
Description of Error Code
Corrective Action Needed
18-1 Appendix A
Checkout procedure log
The following checkout procedure must be performed by qualified personnel
during initial MS4800 system installation and at least every three months or
more frequently depending on machine usage and company guidelines.
Machine identification____________________________ Date____________
Technician Signature ___________________________________________
Item
Condition
Comments
Verify that the guarded machine is compatible with
the type of machine which may be used with the
MS4800 system. See the chapter - "Precautions on
Safety" for further information.
@ Pass
@ Fail
Verify that the mounting distance of the MS4800 sys-
tem is equal to or greater than the minimum safe dis-
tance from the danger point. See the chapter "Safe
mounting distance" for further information.
@ Pass
@ Fail
Determine that all access to the danger point not pro-
tected by the MS4800 system is guarded by other
means, such as gates, fencing or other approved
methods. Verify that all additional guarding devices
are installed and operating properly.
@ Pass
@ Fail
Make sure the operator is not able to stand between
the MS4800 system detection zone and the machine
danger point. Verify that the light curtain can only be
reset from a position outside and within view of the
hazardous machine area.
@ Pass
@ Fail
Inspect the electrical connections between the
guarded machine's control system and the MS4800
system. Verify that they are properly connected to
the machine such that a stop signal from the
MS4800 system results in an immediate halt of the
machine's cycle. See the chapter "Connecting to the
machine control circuit" for further information.
@ Pass
@ Fail
If the EDM monitoring feature is not used, proceed to
the next step. To test the EDM feature, verify that the
feature has been enabled. Turn the machine power
on. Cycle the machine. Place a temporary jumper
wire between the EDM connections. The MS4800
should enter an alarm condition. Remove the tempo-
rary jumper. Press and release the start button.
@ Pass
@ Fail
Record the test results in the machine log, then per-
form the test procedure.
@ Pass
@ Fail
18-2 Appendix B
Test procedure log
The following test procedure must be performed by qualified personnel during
initial MS4800 system installation, according to the employer's regular inspec-
tion program and after any maintenance, adjustment or modification to the
MS4800 system or the guarded machine. Testing ensures that the light cur-
tain, safety system, and machine control system work together to properly
stop the machine. Failure to test properly could result in serious injury to per-
sonnel. To test the MS4800 system, use the correct size test object.
Machine identification_____________________________ Date___________
Technician Signature ____________________________________________
Item
Condition
Comments
Disable the guarded machine. Apply power to the
MS4800 system.
@ Pass
@ Fail
Visually inspect the machine to ensure that access to
the danger point is only through the MS4800 detec-
tion zone. If not, additional guarding, including
mechanical barriers ma be required. Verify that all
additional guarding devices and barriers are installed
and operating properly.
@ Pass
@ Fail
Verify that the mounting distance of the MS4800 sys-
tem is equal to or greater than the calculated mini-
mum safety distance from the danger point. See the
chapter "Safe mounting distance" for further informa-
tion. Ensure that the operator is not able to stand
between the MS4800 detection zone and the danger
point.
@ Pass
@ Fail
Check for signs of external damage to the MS4800
system, the machine and the electrical cables and
wiring. If damage is found, lock the machine off and
report to the supervisor.
@ Pass
@ Fail
Interrupt the MS4800 system detection zone with the
proper size test object. Move the test object inside
the perimeter (along the top, sides and bottom) of the
detection zone and up and down through the center.
At least one individual beam indicator must be lit
while the test object is anywhere in the detection
zone. If in automatic start mode, verify that the red
MACHINE STOP light is lit. If in start/restart INTER-
LOCK mode, verify that the red MACHINE STOP and
yellow INTERLOCK lights are on. Press and release
start button before proceeding to next step.
@ Pass
@ Fail
Start the machine. While the machine is in motion,
interrupt the detection zone with the test object. The
machine should stop immediately. Never insert the
test object into the dangerous parts of the machine.
With the machine at rest, interrupt the detection zone
with the test object. Verify that the machine will not
start with the test object in the detection zone.
@ Pass
@ Fail
Verify that the braking system is working properly. If
the machine does not stop fast enough, adjust the
braking system or increase the distance from the
detection zone to the danger point.
@ Pass
@ Fail
If the safety devices or the machine fails any of these
tests, do not fun the machine. Immediately tag or
LOCKOUT the machine to prevent its use and notify
the supervisor.
@ Pass
@ Fail
A manual revision code appears as a suffix to the catalog number on the front cover of the manual.
The following table outlines the changes made to the manual during each revision. Page numbers refer to the
previous version.
Revision code
Date
Revised content
01
January 2008
Original production
Cat. No. F04E-EN-01
Revision code